Plat and Subdivision Committee
Regular MeetingArlington Heights, IL · August 10, 2016
Agenda
Village of Arlington Heights
Plat and Subdivision Committee
Community Room, 3rd Floor
Arlington Heights Village Hall
33 S. Arlington Heights Road
Arlington Heights, IL 60005
August 10, 2016
7:00 PM
I. CALL TO ORDER
II. ROLL CALL
III. APPROVAL OF MINUTES
IV. REPORTS
V. OLD BUSINESS
VI. NEW BUSINESS
A. Thomas Middle School - 1430 N. Belmont Ave. - T1564
Special Use for a School, Multiple Variations
VII. OTHER BUSINESS
VIII.ADJOURNMENT
Persons with disabilities requiring auxiliary aids or services, such as an
American Sign Language interpreter or written materials in accessible
formats, should contact David Robb, Disability Services Coordinator, at 33 S.
Arlington Heights Road, Arlington Heights, Illinois 60005, (847)368-5793
(Voice), (847)368-5980 (Fax) or drobb@vah.com.
Item: Thomas Middle School - 1430 N. Belmont Ave. - T1564
Department: Planning & Community Development
Requested Action
Special Use Permit to allow a Middle School within the R-3 District.
Variations Identified
1. A Variation from Section 5.1-3.9 to increase the maximum allowable height
from 25’ to 32’ for the proposed building addition.
2. A Variation from Section 11.4-4 to reduce the required on-site parking spaces
from 314 spaces to 144 spaces.
RECOMMENDATION
The Staff Development Committee reviewed the proposed request and supports
the proposed Special Use Permit and Variations, subject to the following:
1. A neighborhood meeting shall be held prior to the Plan Commission hearing.
2. These are preliminary comments only and should not be relied upon as
identification of the only major issues. The Staff Development Committee
reserves the right to change its position on issues upon submittal of a formal
application and detailed review.
ATTACHMENTS:
Description Type
Staff Report Board or Commission Report
Aerial Exhibits
Cover Letter Correspondence
Plat of Survey Exhibits
Plans Exhibits
Thomas Middle School SUP, Temporary File 1564
STAFF DEVELOPMENT COMMITTEE REPORT
To: Plat and Subdivision Committee
Prepared By: Sam Hubbard, Development Planner
Meeting Date: August 10, 2016
Date Prepared: August 5, 2016
Project Title: Thomas Middle School SUP
Address: 1430 N. Belmont Ave.
BACKGROUND INFORMATION
Petitioner: Don Hanson
Address: 350 W Ontario St – Suite 200
Chicago, IL 60654
Existing Zoning: R-3, One Family Dwelling District
Requested Action:
Special Use Permit to allow a Middle School within the R-3 District.
Variations Identified:
Variation from Section 5.1-3.9 to increase the maximum allowable height from 25’ to 32’ for the proposed building addition
Variation from Section 11.4-4 to reduce the required on-site parking spaces from 314 spaces to 144 spaces.
Subject Site
NORTH
Surrounding Properties:
Direction Zoning Existing Use Comprehensive Plan
R-1, One Family Dwelling District Single Family Homes Single Family Detached
North
R-3, One Family Dwelling District Single Family Homes Single-Family Detached
South
R-3, One Family Dwelling District Single Family homes, Green Slopes Single Family Detached,
East Park, and Orchard Church Government, and Institutional
Page 1 of 4
Thomas Middle School SUP, Temporary File 1564
R-6, Multiple Family Dwelling District Multi-Family homes, Medical Office Moderate Density Multi-Family
West and I, Institutional District Complex, Daycare, and Florist Shop and Offices Only
Background:
The subject property is 10.82 acres in size and contains the Thomas Middle School and associated recreational areas on the
southern end of the site. Thomas Middle School is one of six middle schools within the boundaries of District 25 and has a current
enrollment of 950 students with 127 staff members. Enrollment is expected to increase in the future, with future capacity estimated
at 1,030 students and 135 teachers. In order to provide adequate space for the anticipated increase in student population, District
25 is proposing an addition to the middle school building, which would include a new gymnasium, classrooms, a relocated front
entry area, and an addition to the existing parking lot on the eastern side of the site. With the exception of morning drop offs for 6th
grade students, who are dropped off in the western parking lot that has ingress/egress onto Thomas Street, all pick-ups and drop-
offs occur on the eastern side of the site along Belmont Street. There is no change proposed to the pick-up and drop-off operations.
The subject site is located within the R-3 District, and all schools within the R-3 District are required to have a Special Use Permit,
Moreover, any substantial expansion of a school facility would require an amendment to the Special Use Permit. No evidence of an
existing Special Use Permit has been located for the Thomas School site, and therefore, due to the proposed expansion of the
school, a special use permit is required. The School District recently went through a similar process for expansions to the Ivy Hill
and Olive-Mary Stitt schools in 2015.
Zoning and Comprehensive Plan
As indicated above, the property is within the R-3, One Family Dwelling District, and all schools are classified as a special uses
within the R-3 District. Therefore, a Special Use Permit is required. The petitioner will be required to demonstrate conformance to
the following criteria necessary for Special Use Permit approval:
1. That said special use is deemed necessary for the public convenience at this location.
2. That such case will not, under the circumstances of the particular case, be detrimental to the health, safety, morals
or general welfare of persons residing or working in the vicinity.
3. That the proposed use will comply with the regulations and conditions specified in this ordinance for such use, and
with the stipulations and conditions made a part of the authorization granted by the Village Board of Trustees.
The Village's Comprehensive Plan designates the future use of the subject property as “Schools”. The proposed Special Use is
therefore consistent with the Comprehensive Plan.
Site Plan, Building and Landscaping
Overall, the school district is proposing a 20,270 sq. ft. addition to the existing building. The total size of the school will increase to
144,270 sq. ft., and the addition therefore represents a 14% increase in floor area. The proposed addition will house a new
gymnasium and locker room area, as well as increased space for the new front entry and reception office areas. The existing gym
will be converted to additional classrooms. Staff notes that this project must proceed to the Design Commission for their review and
approval of the building architecture and landscaping.
Certain variations are required to accommodate this addition. Specifically, the proposed height of the gymnasium addition will be
approximately 32 feet and the R-3 District limits structure heights to a maximum of 25’. The existing building is approximately 33’8”
in height and therefore the proposed addition will not increase this existing non-conformity. Furthermore, the proposed addition will
be centrally located on the subject property and therefore will be substantially away from the immediately abutting residential areas
to the south of the property. For these reasons, staff is supportive of the proposed height variation.
While a height variation for the proposed addition is required, the School District may also wish to include within their request, a
height variation for the existing 33’8” tall building to allow the existing non-conformity. Although no changes are being made to the
height of the existing building, a variation would clarify that the non-conforming height is allowed. Similarly, the existing building is
non-compliant with regards to setbacks along the north and east sides. Even though no changes to building within these setback
areas have been proposed, a setback variation for the existing building would confirm that the non-conforming setbacks have been
approved.
Page 2 of 4
Thomas Middle School SUP, Temporary File 1564
Based on a preliminary analysis, the proposed building addition will conform to all setback and additional bulk restrictions. However,
upon comprehensive review of the detailed plans, additional variations may be identified.
As part of the Plan Commission process, the petitioner will be required to provide justification for the requested Variations per the
approval criteria as summarized below:
The property in question cannot yield a reasonable return if per mitted to be used only under the conditions
allowed by the regulations in that zone.
The plight of the owner is due to unique circumstances.
The variation, if granted, will not alter the essential character of the locality.
Finally, staff recommends that the petitioner hold a neighborhood meeting prior to the Plan Commission hearing to introduce the
project to the surrounding neighbors to understand what concerns they may have.
Traffic & Parking
Exhibit 1 (attached) analyzes the current and proposed parking calculations for the subject property. A parking deficit currently
exists and the proposed addition to the building and parking area will not eliminate this deficit. Therefore, a parking variation to
reduce the number of required parking spaces is necessary. As the existing site operates at a 65% parking deficit, and the
proposed alterations to the site will reduce this deficit to 55%, staff is generally supportive of the proposed variation. However, the
petitioner will be required to submit a traffic and parking analysis that evaluates the existing and proposed parking demands as well
as drop-off and pick-up operations. Staff is not aware of an existing parking problem on the subject property, but will analyze the
parking counts submitted by the petitioner to ensure a parking problem does not currently exist.
RECOMMENDATION
The Staff Development Committee reviewed the proposed request and supports the proposed Special Use Permit and Variations,
subject to the following:
1. A neighborhood meeting shall be held prior to the Plan Commission hearing.
2. These are preliminary comments only and should not be relied upon as identification of the only major issues. The Staff
Development Committee reserves the right to change its position on issues upon submittal of a formal application and detailed
review.
________________________________________ August 5, 2016
Bill Enright, Deputy Director of Planning and Community Development
Cc: Randy Recklaus, Village Manager
All Department Heads
Temp File 1564
Page 3 of 4
Thomas Middle School SUP, Temporary File 1564
Exhibit 1 – Parking Analysis
PARKING CODE NUMBER OF NUMBER OF
SPACE PARKING RATIO PARKING REQUIRED
USE EMPLOYEES CLASSROOMS
Existing 1 space per
Thomas classroom plus two
Elementary School 127 41 295
Middle space per
School employee
Total Parking Required 295
Total Parking Provided 102
193 (65% reduction in
Parking Surplus/(Deficit)
required parking)
Proposed 1 space per
Thomas classroom plus two
Elementary School 135 44 314
Middle space per
School employee
Total Parking Required 314
Total Parking Provided 141
173 (55% reduction in
Parking Surplus/(Deficit)
required parking)
Page 4 of 4
Thomas Middle School - Aerial
August 5, 2016 1:4,514
0 0.0375 0.075 0.15 mi
0 0.05 0.1 0.2 km
Village of Arlington Heights GIS
Copyright 2013