Muyni
← Back to DeKalb

Planning & Zoning Commission

Regular Meeting

DeKalb, IL · January 3, 2018

AgendaMinutes

Minutes

MINUTES CITY OF DEKALB PLANNING AND ZONING COMMISSION January 3, 2018 The Planning and Zoning Commission held a Meeting on January 3, 2018 at the City of DeKalb Municipal Building, 200 S. Fourth St., DeKalb, Illinois. Chair Atherton called the meeting to order at 6:00 PM. A. ROLL CALL Principal Planner, Dan Olson called the roll. Planning and Zoning Commission members present were Chair Christina Atherton, Vicki Buckley, David Castro and Jerry Wright. Members absent were Katharina Barbe, Matthew Crull and Deborah Nier. City staff present were Principal Planner Dan Olson and Recording Secretary Linda Odom. B. APPROVAL OF THE AGENDA (Additions/Deletions) Chair Atherton requested a motion to approve the January 3, 2018 agenda as presented. Ms. Buckley motioned to approve the agenda as presented, Mr. Castro seconded the motion, and the motion was approved by unanimous voice vote. C. APPROVAL OF MINUTES December 6, 2017 – Mr. Castro motioned to approve the minutes as presented, Mr. Wright seconded the motion, and the motion was approved by unanimous voice vote. D. PUBLIC PARTICIPATION (Open Floor to Anyone Wishing to Speak on Record) None E. NEW BUSINESS 1. Public Hearing on the petition by T-Mobile Central, LLC represented by Amanda Wegrzyn, of NTP Wireless for approval of a Special Use Permit for an existing antenna to allow for an upgrade of communication equipment on top of the 16-story building located at 507 E. Taylor Street and zoned “RC-1” Residential Conservation 1 District. Amanda Wegrzyn of NTP Wireless gave a presentation to the Commission for the special use permit to upgrade the T-Mobile equipment at 507 E. Taylor St. She noted the building owner, the Housing Authority of the County of DeKalb, Planning and Zoning Commission January 3, 2018 Page 2 of 3 has approved the proposed upgrades. Ms. Wegrzyn mentioned there are 12 antennas in three sectors and there will be a one to one replacement of the antennas, with no new cabinets added. She added they will be installing concealment tape to camouflage the equipment and antennas, which will help them blend into the existing environment. Ms. Wegrzyn added the tape will go on all existing and proposed equipment. She said the concealment tape is a new technology from 3M and acts as a mirror and reflects the sky. She showed photo simulations indicating existing and proposed views from all directions. Ms. Wegrzyn also showed samples of other screening options if the reflective tape was not used. She noted the existing cabinets and radio units can also be camouflaged with the reflective tape. Principal Planner Olson went through the staff report dated December 29, 2017 provided in the Commission’s packet, which recommended approval of the request. Chair Atherton opened up to public for questions and comments. Dave Lehman, 621 Karen Ave., DeKalb asked Ms. Wegrzyn if the proposed upgrades will improve T-Mobile’s coverage. Ms. Wegrzyn responded yes it will improve coverage. Chair Atherton then asked if any Commissioners had questions. Mr. Castro asked Ms. Wegrzyn if the proposed work will add any more surface space. She responded that the space will remain the same. Mr. Castro clarified with Mr. Olson if this will bring a legal non-conforming use into compliance. Mr. Olson responded that it will. Mr. Wright stated to Ms. Wegrzyn that he appreciates their effort in getting rid of visual pollution. He asked her the difference in the Tower Mounted Amplifiers (TMA) and the radio units. Ms. Wegrzyn answered that it will help with coverage. Chair Atherton stated she thinks the concealment tape is a good concept and wanted to know what the anticipated time it would stay on the equipment and when it would have to be replaced. Ms. Wegrzyn answered that the specifications from 3M indicate the expected performance is 10 years and added that T-Mobile will maintain it properly. She added that on average the equipment is inspected every couple of months by T-Mobile. Mr. Castro asked if there would be any issue using the concealment tape and birds. Ms. Wegrzyn said the material that is used does not draw birds. Mr. Olson suggested to the Commission that part of the motion could include that the applicant and City staff would work together to determine if another type of screening could be used to screen the cabinet. Chair Atherton gave the public one more chance to speak. There were no more public comments. There was no further discussion from the Commission. Planning and Zoning Commission January 3, 2018 Page 3 of 3 Mr. Castro made a motion based on the submitted petition and testimony presented that the Planning and Zoning Commission forward its findings of fact and recommend to the City Council approval of a Special Use Permit for upgrades to existing T-Mobile antenna and associated equipment on top of a 16 story building located at 507 E. Taylor Street subject to the following: 1. The antenna and equipment upgrades and proposed use of concealment tape shall comply with the drawings indicated on Exhibit A. 2. The applicant will be required to submit the necessary application and plans to the City in compliance with applicable Building Codes and the regulations of Article 7.08 of the UDO. Mr. Olson suggested the following amended language to the motion “that applicant will work with staff to use other screening for the cabinet if it reduces visual impact more than the reflective film”. Mr. Castro agreed with the amendment and Mr. Wright seconded the motion. A roll call vote was taken. Ms. Buckley – yes, Mr. Castro – yes, Mr. Wright – yes, Chair Atherton – yes, motion passes 4-0-3. Ms. Barbe, Ms. Nier and Mr. Crull were absent. F. REPORTS Mr. Olson mentioned the next Planning and Zoning Commission meeting will be January 17, 2018. There will be a public hearing regarding text amendments to the UDO regarding self-storage facilities. G. ADJOURNMENT Mr. Wright motioned to adjourn, Ms. Buckley seconded the motion, and the motion was approved by unanimous voice vote. The meeting adjourned at 6:32 PM. Respectfully Submitted, Linda Odom, Recording Secretary Minutes were approved by the Planning and Zoning Commission on January 17, 2018.

Agenda

DeKalb Municipal Building Council Chambers 200 S. Fourth St., 2nd Floor DeKalb, IL 60115 AGENDA Planning and Zoning Commission January 3, 2018 6:00 PM A. ROLL CALL B. APPROVAL OF AGENDA (Additions or Deletions) C. APPROVAL OF MINUTES 1. December 6, 2017 D. PUBLIC PARTICIPATION (Open Floor to Anyone Wishing to Speak on Record) E. NEW BUSINESS 1. Public Hearing on the petition by T-Mobile Central, LLC represented by Amanda Wegrzyn, of NTP Wireless for approval of a Special Use Permit for an existing antenna to allow for an upgrade of communication equipment on top of the 16-story building located at 507 E. Taylor Street and zoned “RC-1” Residential Conservation 1 District. F. REPORTS G. ADJOURNMENT MINUTES CITY OF DEKALB PLANNING AND ZONING COMMISSION December 6, 2017 The Planning and Zoning Commission held a Meeting on December 6, 2017 at the City of DeKalb Municipal Building, 200 S. Fourth St., DeKalb, Illinois. Chair Atherton called the meeting to order at 6:01 PM. A. ROLL CALL Principal Planner, Dan Olson called the roll. Planning and Zoning Commission members present were Chair Christina Atherton, Vicki Buckley, David Castro and Matthew Crull. Members absent were Katharina Barbe, Deborah Nier and Jerry Wright. City staff present were Principal Planner Dan Olson and Recording Secretary Linda Odom. B. APPROVAL OF THE AGENDA (Additions/Deletions) Chair Atherton requested a motion to approve the December 6, 2017 agenda as presented. Mr. Crull motioned to approve the agenda as presented, Mr. Castro seconded the motion, and the motion was approved by unanimous voice vote. C. APPROVAL OF MINUTES November 8, 2017 – Ms. Buckley motioned to approve the minutes as presented, Mr. Castro seconded the motion, and the motion was approved by unanimous voice vote. D. PUBLIC PARTICIPATION (Open Floor to Anyone Wishing to Speak on Record) Dave Lehman, 621 Karen Ave., DeKalb, thanked the Commission for all their work on the recent Verizon cell tower (S. 7th St.) public hearing. He suggested the Unified Development Ordinance needs some revisiting regarding the goals and purposes in relation to cell towers. He added the co-location protocol provisions especially need to be looked at and the responsibilities of applicants need tweaking. E. NEW BUSINESS Public Hearing on City-initiated text amendments to Municipal Code Chapter 23 “Unified Development Ordinance”: Article 13 “Signs,” Section 13.07.07(1) to allow projecting signs in the “CBD” Central Business District to include products sold Planning and Zoning Commission December 6, 2017 Page 2 of 3 with restrictions on text and size and any related amendments deemed necessary pursuant to public hearing and review. Principal Planner, Dan Olson went over the staff report dated December 1, 2017, which recommended approval of the proposed amendments. He summarized the background of the existing projecting sign regulations, the request by Gordon Hardware (514 E. Lincoln Highway) to place a product in their projecting sign and the analysis on why the amendments should be approved. Chair Atherton opened for the public to speak. Trixy O’Flaherty, the owner of Gordon Hardware, indicated she wanted to do something unique with their projecting sign and had proposed a wrench to be part of the bracing of the sign. She said the City should be encouraging businesses to put up creative signs. She mentioned her support for the proposed amendments. Ms. O’Flaherty said there were other non-conforming signs in the downtown area. Mr. Olson noted that wall signs, which comprise the vast majority of signs in the downtown area, do not have restrictions on products sold being part of the sign. Mr. Castro said he supported the amendment, but was unclear as to why this is in place when wall signs are not restricted. Mr. Olson responded that it has been in place a long time and didn’t know a specific reason. Mr. Castro mentioned he doesn’t feel like the City should be in the way of good ideas like this. He commended Ms. O’Flaherty for working with the City and going about this in the correct way and just not putting up an illegal sign. Mr. Castro added he cares about what will come in the future and believes the amendments will have a positive effect on the City. Mr. Crull feels that as long as signs aren’t visually obstructive or offensive he doesn’t see anything wrong with the proposed amendment. Chair Atherton said the remodeling on the building (Gordon Hardware) looks great and commended Ms. O’Flaherty. Chair Atherton asked once more if anyone else would like to speak. There was no one else. The public hearing was closed at 6:19 p.m. Mr. Crull made a motion that the text amendments regarding projecting signs as described in Exhibit A to the Text Amendment application dated 11-17-17 be approved. Seconded by Ms. Buckley. A roll call vote was taken. – Vicki Buckley – yes, David Castro – yes, Matthew Crull – yes, Chair Atherton – yes. Motion passes 4-0-3. Planning and Zoning Commission December 6, 2017 Page 3 of 3 F. REPORTS Mr. Olson reported the City Council denied the Verizon cell tower special use permit application by unanimous vote at their November 27th meeting. He added that January 3, 2018 will be the next Commission meeting date and the December 20th meeting will be cancelled. He wished the Commission Happy Holidays. G. ADJOURNMENT Ms. Buckley motioned to adjourn, Mr. Castro seconded the motion, and the motion was approved by unanimous voice vote. The meeting adjourned at 6:21 PM. Respectfully Submitted, Linda Odom, Recording Secretary Minutes were approved by the Planning and Zoning Commission on . COMMUNITY DEVELOPMENT DEPARTMENT STAFF REPORT December 29, 2017 TO: DeKalb Planning and Zoning Commission FROM: Dan Olson, Principal Planner RE: Special Use Permit for Existing Antenna Equipment (T-Mobile) – 507 E. Taylor St. I. GENERAL INFORMATION A. Purpose To obtain a special use permit to upgrade existing cellular antenna equipment on top of an existing 16-story building B. Location 507 E. Taylor Street (Taylor Street Plaza) C. Size 2.18 acres D. Existing Zoning “RC-1” Residential Conservation 1 District E. Existing Land Use 16-story residential building F. Proposed Land Use No change; upgrade cellular antenna equipment G. Surrounding Zoning and Land Use North: RC-1; Single-family and multi-family residential South: SFR2; Elementary school East: RC-1; Multi-family residential, park West: RC-1; Park, single family residences H. Comprehensive Plan Designation High Density Residential II. APPLICANT'S REQUEST The applicant, T-Mobile Central, LLC represented by Amanda Wegrzyn, of NTP Wireless requests the approval of a special use permit to upgrade existing cellular communications equipment on top of an existing 16-story residential building at 507 E. Taylor Street (Taylor Street Plaza), which is zoned “RC-1” Residential Conservation District 1. Page 2 of 7 III. BACKGROUND AND ANALYSIS The applicant would like to upgrade existing cellular antenna equipment on top of the 16-story Taylor Street Plaza building at 507 E. Taylor Street. The existing equipment is considered a legal non-conforming use as they do not have a special use for property. Per the Unified Development Ordinance (UDO), co-locating or upgrading existing equipment on existing non-tower structures, such as buildings requires a special use. There are a total of three carriers that have equipment on top of the building. T-Mobile’s existing equipment is located in three different areas on the roof. The modifications are necessary to deploy and modernize T-Mobile’s equipment in DeKalb. T-Mobile is proposing to remove and replace three existing panel antennas, upgrade equipment and have concealment tape installed on the antenna and equipment to minimize the visual effect on the surrounding area. Photo simulations provided by the applicant show the existing equipment as viewed from the ground and how they will look once the concealment tape is applied. Article 7.08 of the Unified Development Ordinance (UDO), regulates the placement, design and use of wireless communication equipment. Co-locating or upgrading existing equipment on existing non-tower structures, such as buildings require a special use permit. This section of the UDO also stipulates that compliance with certain criteria needs to be demonstrated by the applicant prior to approval of the special use. The criteria are addressed in the following sections of the staff report, IV. Standards of Special Use Permit for Antenna Facilities and V. Standards of a Special Use. IV. STANDARDS OF SPECIAL USE PERMIT FOR ANTENNA FACILITIES– ARTICLE 7.08.08 1. Points of Visual Interest Shall Be Protected. The only point of visual interest, as defined by the UDO, in the vicinity of the subject property is park property to the east and west of the subject site. The proposed upgrade to the equipment will have no impact on the park areas as the equipment is on top of an existing 16-story building. Additionally, concealment tape will be installed to visually screen the equipment further reducing the visual impact of T-Mobile’s equipment. 2. Methods for Protecting Points of Visual Interest. As noted in standard #1, concealment tape, a non-metallic reflective film technology, is proposed around the existing and new equipment to screen it from ground view and to blend it in with the surrounding environment. 3. Color Reflective screening of the equipment is proposed to reduce the visual impact on the surrounding Page 3 of 7 area. 4. Height The UDO stipulates that antennas may be permitted provided it is no greater than 22 feet taller than the existing structure. The proposed antennas will be 11 feet above the existing building. Setbacks Adjacent to Residential Uses As the proposed antennas are existing and being upgraded, this criterion does not apply to this request. 5. Lighting The UDO stipulates that no lighting is permitted except as required by the Federal Aviation Administration (FAA). There is no lighting present on the rooftop equipment and none will be added as part of the modifications proposed. The FAA does not require lighting at this location. 6. Fencing and Security Since the upgrade is for roof-top equipment, this criterion does not apply. 7. Landscaping and Screening Since the upgrade is for rooftop equipment, no landscaping is required. The applicant is proposing to have concealment tape installed on the antenna and equipment to minimize the visual effect to the surrounding area. 8. Noise No noise generating equipment is present or proposed at this location. 9. Tower Design Since this is an upgrade to existing equipment on the roof-top of the building, this criterion does not apply. V. STANDARDS OF A SPECIAL USE – ARTICLE 14.03.05 (2) 1. The proposed special use complies with all provisions of the applicable district regulations. The proposed special use is for an upgrade to existing equipment that is co-locating on an existing Page 4 of 7 building with other cell carriers. The property is zoned RC-1 Residential Conservation District and the proposed special use meets all the requirements of the District and Article 7.08 (Wireless Communications Ordinance) of the UDO. 2. The proposed special use will not be unreasonably detrimental to the value of other property in the neighborhood in which it is to be located or to the public welfare at large. There has been antenna and associated equipment on top of the building on the subject site since at least 2000 and there is no evidence that the presence of the antennas and equipment has been detrimental to the value of surrounding properties. To further minimize the visual impacts of its site, T-Mobile is proposing to use concealment tape on the antennas and equipment to ensure it further blends into the surrounding neighborhood. 3. The location and size of the special use, the nature and intensity of the operation involved in or conducted in connection with it, and the location of the site with respect to streets giving access to it are such that the special use will not dominate the immediate neighborhood so as to prevent development and use of neighboring property in accordance with the applicable zoning district regulations. The facility is unstaffed and is a low intensity operation. The antenna and associated equipment related to the special use request are located on top of an existing 16-story building and will not dominate the immediate area and will not prevent development on the neighboring properties. 4. Adequate utility, drainage and other such necessary facilities have been or will be provided. The subject site and structure are already served with adequate utilities and the proposed modifications will not impact this. The only utilities that are necessary are telephone and electricity, both of which are already onsite in connection with the existing facilities. 5. The proposed use, where such developments and uses are deemed consistent with good planning practice, or can be operated in a manner that is not detrimental to the permitted developments and uses in the district; can be developed and operated in a manner that is visually compatible with the permitted uses in the surrounding area; shall in all other respects conform to the applicable regulations of the district in which it is located; and is deemed essential or desirable to preserve and promote the public health, safety and general welfare of the City of DeKalb. There has been antenna and associated equipment on top of the building on the subject site since at least 2000 and has operated in a manner that has not been detrimental to other uses in the area. The upgrade in the equipment will provide the residents of the City improved communication capabilities. The applicant is proposing to use concealment tape on the antennas and equipment to minimize the visual effect on the surrounding neighborhood. Page 5 of 7 VI. CITIZEN INPUT To date the City has received a Citizen Response Form from the building owner, Housing Authority of the County of DeKalb, indicating their support for the proposal. VII. CONCLUSIONS AND RECOMMENDATIONS Staff would recommend approval of the special use permit request, which will bring a legal non- conforming use into compliance. The proposed upgrade to the equipment will have no negative impacts on the surrounding area as the equipment is on top of a 16-story building. In addition, the applicant is proposing to have concealment tape installed on the antenna and equipment to minimize the visual effect on the neighborhood. Sample Motion: Based upon the submitted petition and testimony presented, I move that the Planning and Zoning Commission forward its findings of fact and recommend to the City Council approval of a Special Use Permit for upgrades to existing T-Mobile antenna and associated equipment on top of a 16- story building located at 507 E. Taylor Street subject to the following: 1. The antenna and equipment upgrades and proposed use of concealment tape shall comply with the drawings indicated on Exhibit A. 2. The applicant will be required to submit the necessary application and plans to the City in compliance with applicable Building Codes and the regulations of Article 7.08 of the UDO. Page 6 of 7 Exhibit A 1. T-Mobile Drawings dated 12-13-17 prepared by W-T Communication Design Group, LLC. 2. Photo Simulation Depictions submitted in conjunction with the Special Use Permit Application dated 11-17-17 and received 11-20-17 prepared by W-T Communication Design Group, LLC. Page 7 of 7 VICINITY MAP December 11, 2017 Dear Property Owner: The DeKalb Planning and Zoning Commission will consider a request on a petition by T-Mobile Central, LLC represented by Amanda Wegrzyn, of NTP Wireless for approval of a Special Use Permit for an existing antenna on top of a 16-story building to allow for an upgrade of communication equipment. The subject site is located at 507 E. Taylor Street and zoned “RC-1” Residential Conservation 1 District. The DeKalb Planning and Zoning Commission will review these requests and hold a public hearing at its special meeting on Wednesday, January 3, 2018 at 6:00 p.m. The meeting will be at the DeKalb Municipal Building, 200 South Fourth Street, DeKalb, Illinois. As a property owner within 250 feet of the above-mentioned property, you are encouraged to attend this meeting to learn about and comment on the proposal. You are also welcome to submit any written comments you may have on the proposal no later than Wednesday, December 27, 2017. You may submit written comments regarding the request on the enclosed comment sheet by mail to the address listed above, or by e-mail to dan.olson@cityofdekalb.com. All comments will be shared with the Commission and included in the public record. If you have any questions about this request, please feel free to contact the Community Development Department at (815) 748-2060. Sincerely, Dan Olson Interim Principal Planner Enclosures CC: Mayor City Council City Manager Planning and Zoning Commission Applicant 507 E. Taylor St. – Special Use Permit T-Mobile Page 2 of 4 LEGAL NOTICE NOTICE is hereby given that a public hearing will be held before the DeKalb Planning and Zoning Commission at its regular meeting on Wednesday, January 3, 2018, at 6:00 p.m. in the DeKalb Municipal Building, 200 South Fourth Street, DeKalb, Illinois, on the petition by T- Mobile Central, LLC represented by Amanda Wegrzyn, of NTP Wireless for approval of a Special Use Permit for an existing antenna on top of a 16-story building to allow for an upgrade of communication equipment. The subject site is located at 507 E. Taylor Street and zoned “RC- 1” Residential Conservation 1 District. The property is commonly described as 507 E. Taylor Street, DeKalb, IL 60115 and has a Parcel Identification Number (PIN) of 08-23-361-031. All interested persons are invited to appear and be heard at the time and place listed above. Interested persons are also encouraged to submit written comments on these proposals to the City of DeKalb, Community Development Department, 200 South Fourth Street, DeKalb, Illinois, 60115 by 5:00 p.m. on Wednesday, December 27, 2017. Further information is available from the Community Development Department, (815) 748-2060. Christina Atherton, Chairman DeKalb Planning and Zoning Commission Page 4 of 4 8550 BRYN MAWR AVENUE, SUITE 100 CHICAGO, ILLINOIS 60631 PLANS PREPARED BY: 2675 Pratum Avenue Hoffman Estates, Illinois 60192 PH: (224) 293-6333 FAX: (224) 293-6444 www.wtengineering.com IL. License No.: 184.007570-0015 Exp: 04/30/19 C SEAL: SHEET NUMBER: DESCRIPTION: NO NEW WATER OR SEWER IS REQUIRED AS FACILITY IS UNMANNED. T-1 TITLE SHEET T-2 GENERAL NOTES & SPECIFICATIONS 12 ANTENNAS, 6 RRU MODULES, 3 TMA'S, 4 COVP'S, 3 HCS, 6 COAX, 1 SITE SUPPORT CABINET, 1 EXPANSION CABINET, 3 SYSTEM MODULES ON SSC C-1 OVERALL SITE PLAN JEFFERY S. GUTOWSKY, PROFESSIONAL ENGINEER C-1.1 ROOFTOP SITE PLAN 2 STATE OF ILLINOIS LICENSE # 062-047235 C-2 EXISTING & NEW SITE PLANS EXPIRES 11/30/17 SIGNED: 12/13/17 12 ANTENNAS, 9 RRU MODULES, 0 TMA'S, 4 COVP'S, 3 HCS, 1 SITE SUPPORT CABINET, 1 EXPANSION CABINET, 3 SYSTEM MODULES ON SSC A-1 TOWER ELEVATION DATE: DESCRIPTION: BY: REV: A-2 ANTENNA PLANS & SCHEDULE 09/14/16 FOR CLIENT REVIEW WCD A T-MOBILE USA A-3 EQUIPMENT SPECIFICATIONS - INSTALL (3) NEW FRBG'S (1 PER SECTOR) 11/08/16 FINALS RSM 0 - REMOVE (3) EXISTING TMA'S 8550 BRYN MAWR AVE., SUITE 100 A-4 EQUIPMENT SPECIFICATIONS - REPLACE (3) EXISTING ANTENNAS WITH (3) NEW ANTENNAS (1 PER SECTOR) CHICAGO, ILLINOIS 60631 TEL: (773) 444-5400 03/01/17 RFDS REVISION RSM 1 - INSTALL NEW RF JUMPERS FOR NEW AND RELOCATED RRU'S A-5 RF PLUMBING DIAGRAM - UTILIZE EXISTING HCS CONTACT: TBD - INSTALL (1) ADDITIONAL FBBC IN EXISTING LTE FSMF GR-1 GROUNDING DETAILS 12/13/17 REVISION BLW 2 - REPLACE EXISTING UMTS FSME DC BREAKER WITH NEW 63A DC BREAKER (AS NEEDED) GR-2 GROUNDING DETAILS - REPLACE EXISTING LTE FSMF DC BREAKER WITH NEW 63A DC BREAKER (AS NEEDED) - REPLACE EXISTING CSR 7705 SAR-F WITH NEW SAR-M DEKALB HOUSING AUTHORITY 310 N. 6TH ST. DEKALB, IL 60115 815-758-4396 MAP DATA 2017 GOOGLE PENDING APPROVAL OF THE JURISDICTION, THE FOLLOWING PARTIES HAVE LAT: W-T COMMUNICATION DESIGN GROUP, LLC REVIEWED THE DESIGN WITHIN THEIR FUNCTIONAL RESPONSIBILITIES AND HAVE 2675 PRATUM AVENUE APPROVED THIS PROJECT FOR CONSTRUCTION. CONTRACTORS MAY NOT START LONG: CONSTRUCTION WITHOUT A NOTICE TO PROCEED (NTP) FROM T-MOBILE. HOFFMAN ESTATES, ILLINOIS 60192 PH: (224) 293-6333 FAX: (224) 293-6444 PRINT NAME SIGNATURE DATE www.wtengineering.com SITE INFORMATION: LANDLORD 507 E. TAYLOR ST. CONTACT: RYAN MADSEN DEKALB, IL 60115 PH: (224) 293-6433 PRECON. MGR GOLDEN YEARS DEVELOP. MGR PLAZA TAE, INC. 4917 PROFESSIONAL COURT, SUITE 105 RALEIGH, NC 27609 CONST. INSP. CH17481C DATA OBTAINED FROM T-MOBILE RFDS PH: (919) 871-0744 A&E MGR FAX: (919) 871-0345 507 E. TAYLOR ST. RF ENGINEER DEKALB, IL 60115 W-T JOB NUMBER: T1601208 OPERATIONS SHEET TITLE: ZONING REP UTILITIES BUILDING CODE: 2003 INTERNATIONAL BUILDING CODE ELECTRICAL CODE: 2002 NATIONAL ELECTRICAL CODE SHEET NUMBER: A SITE WALK WAS NOT PERFORMED FOR THIS SITE PER SCOPE OF WORK. COMPOUND, ELEVATION, SHELTER/EQUIPMENT LAYOUT AND ANTENNA PLANS SHOWN WITHIN THIS SET WERE TAKEN FROM AVAILABLE DOCUMENTS/DRAWINGS. MAP DATA 2017 GOOGLE PLOT SCALE: 1:1 @ 11"x17" 1.11 ADMINISTRATION 1. BEFORE THE COMMENCEMENT OF ANY WORK, THE CONTRACTOR WILL ASSIGN A PROJECT 1.1 INTENT MANAGER WHO WILL ACT AS A SINGLE POINT OF CONTACT FOR ALL PERSONNEL INVOLVED IN 1. SUBMITTAL OF BID INDICATES CONTRACTOR IS COGNIZANT OF ALL JOB SITE CONDITIONS AND 1. THESE SPECIFICATIONS AND CONSTRUCTION DRAWINGS ACCOMPANYING THEM DESCRIBE THIS PROJECT. THIS PROJECT MANAGER WILL DEVELOP A MASTER SCHEDULE FOR THE WORK TO BE PERFORMED UNDER THIS CONTRACT. THE WORK TO BE DONE AND THE MATERIALS TO BE FURNISHED FOR CONSTRUCTION. PROJECT WHICH WILL BE SUBMITTED TO THE OWNER PRIOR TO THE COMMENCEMENT OF ANY WORK. 2. CONTRACTOR SHALL PERFORM ALL VERIFICATION OBSERVATIONS TEST, AND EXAMINATION 2. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO BE FULLY EXPLANATORY AND WORK PRIOR TO THE ORDERING OF THE ELECTRICAL EQUIPMENT AND THE ACTUAL SUPPLEMENTARY. HOWEVER, SHOULD ANYTHING BE SHOWN, INDICATED OR SPECIFIED ON 8550 BRYN MAWR AVENUE, SUITE 100 2. SUBMIT A BAR TYPE PROGRESS CHART NOT MORE THAN 3 DAYS AFTER THE DATE CONSTRUCTION. CONTRACTOR SHALL ISSUE A WRITTEN NOTICE OF ALL FINDINGS TO THE ONE AND NOT THE OTHER, IT SHALL BE DONE THE SAME AS IF SHOWN, INDICATED OR CHICAGO, ILLINOIS 60631 ESTABLISHED FOR COMMENCEMENT OF THE WORK ON THE SCHEDULE, INDICATING A TIME ARCHITECT LISTING ALL MALFUNCTIONS, FAULTY EQUIPMENT AND DISCREPANCIES. SPECIFIED IN BOTH. BAR FOR EACH MAJOR CATEGORY OR UNIT OF WORK TO BE PERFORMED AT SITE, PROPERLY SEQUENCED AND COORDINATED WITH OTHER ELEMENTS OF WORK AND SHOWING 3. EACH CONDUCTOR OF EVERY SYSTEM SHALL BE PERMANENTLY TAGGED IN EACH PANEL PLANS PREPARED BY: 3. THE INTENTION OF THE DOCUMENTS IS TO INCLUDE ALL LABOR AND MATERIALS REASONABLY COMPLETION OF THE WORK SUFFICIENTLY IN ADVANCE OF THE DATE ESTABLISHED FOR BOARD, PULL BOX, J-BOX, SWITCH BOX, ETC., IN COMPLIANCE WITH OCCUPATIONAL SAFETY NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK AS STIPULATED IN SUBSTANTIAL COMPLETION OF THE WORK. AND HEALTH ACT (O.S.H.A.). THE CONTRACT. 3. PRIOR TO COMMENCING CONSTRUCTION, THE OWNER SHALL SCHEDULE AN ON-SITE MEETING 4. CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, INSURANCE, EQUIPMENT, 4. THE PURPOSE OF THE SPECIFICATIONS IS TO INTERPRET THE INTENT OF THE DRAWINGS AND WITH ALL MAJOR PARTIES. THIS WOULD INCLUDE (THOUGH NOT LIMITED TO) THE OWNER, INSTALLATION, CONSTRUCTION TOOLS, TRANSPORTATION, ETC., FOR A COMPLETE AND TO DESIGNATE THE METHOD OF THE PROCEDURE, TYPE AND QUALITY OF MATERIALS PROJECT MANAGER, CONTRACTOR, LAND OWNER REPRESENTATIVE, LOCAL TELEPHONE PROPERLY OPERATIVE SYSTEM ENERGIZED THROUGHOUT AND AS INDICATED ON DRAWINGS, REQUIRED TO COMPLETE THE WORK. COMPANY, TOWER ERECTION FOREMAN (IF SUBCONTRACTED). AS SPECIFIED HEREIN AND/OR AS OTHERWISE REQUIRED. 5. MINOR DEVIATIONS FROM THE DESIGN LAYOUT ARE ANTICIPATED AND SHALL BE CONSIDERED 4. CONTRACTOR SHALL BE EQUIPPED WITH SOME MEANS OF CONSTANT COMMUNICATIONS, 5. ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND IN PERFECT CONDITION WHEN INSTALLED AS PART OF THE WORK. NO CHANGES THAT ALTER THE CHARACTER OF THE WORK WILL BE SUCH AS A MOBILE PHONE OR A BEEPER. THIS EQUIPMENT WILL NOT BE SUPPLIED BY THE AND SHALL BE OF THE BEST GRADE AND OF THE SAME MANUFACTURER THROUGHOUT FOR MADE OR PERMITTED BY THE OWNER WITHOUT ISSUING A CHANGE ORDER. OWNER, NOR WILL WIRELESS SERVICE BE ARRANGED. EACH CLASS OR GROUP OF EQUIPMENT. MATERIALS SHALL BE LISTED "J" WHERE SUBJECT TO SUCH APPROVAL. MATERIALS SHALL MEET WITH APPROVAL OF THE DIVISION OF INDUSTRIAL 2675 Pratum Avenue 1.2 CONFLICTS 5. DURING CONSTRUCTION, CONTRACTOR MUST ENSURE THAT EMPLOYEES AND SAFETY AND ALL GOVERNING BODIES HAVING JURISDICTION. MATERIALS SHALL BE Hoffman Estates, Illinois 60192 SUBCONTRACTORS WEAR HARD HATS AT ALL TIMES. CONTRACTOR WILL COMPLY WITH ALL PH: (224) 293-6333 FAX: (224) 293-6444 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL MEASUREMENTS AT THE MANUFACTURED IN ACCORDANCE WITH APPLICABLE STANDARDS ESTABLISHED BY ANSI, NEMA www.wtengineering.com SITE BEFORE ORDERING ANY MATERIALS OR DOING ANY WORK. NO EXTRA CHARGE OR SAFETY REQUIREMENTS IN THEIR AGREEMENT. AND NBFU. IL. License No.: 184.007570-0015 Exp: 04/30/19 COMPENSATION SHALL BE ALLOWED DUE TO DIFFERENCE BETWEEN ACTUAL DIMENSIONS AND DIMENSIONS INDICATED ON THE CONSTRUCTION DRAWINGS. ANY SUCH DISCREPANCY IN 6. PROVIDE WRITTEN DAILY UPDATES ON SITE PROGRESS TO THE OWNER. 6. ALL CONDUIT INSTALLED SHALL BE SURFACE MOUNTED OR DIRECT BURIAL UNLESS C DIMENSION WHICH MAY BE FOUND SHALL BE SUBMITTED TO THE OWNER FOR CONSIDERATION OTHERWISE NOTED. 7. COMPLETE INVENTORY OF CONSTRUCTION MATERIALS AND EQUIPMENT IS REQUIRED PRIOR BEFORE THE CONTRACTOR PROCEEDS WITH THE WORK IN THE AFFECTED AREAS. TO START OF CONSTRUCTION. SEAL: 7. CONTRACTOR SHALL CARRY OUT THEIR WORK IN ACCORDANCE WITH ALL GOVERNING STATE, 2. THE BIDDER, IF AWARDED THE CONTRACT, WILL NOT BE ALLOWED ANY EXTRA COMPENSATION COUNTY AND LOCAL CODES AND O.S.H.A. BY REASON OF ANY MATTER OR THING CONCERNING WHICH SUCH BIDDER MIGHT HAVE FULLY 8. NOTIFY THE OWNER / PROJECT MANAGER IN WRITING NO LESS THAN 48 HOURS IN ADVANCE INFORMED THEMSELVES PRIOR TO THE BIDDING. OF CONCRETE POURS, TOWER ERECTIONS, AND EQUIPMENT CABINET PLACEMENTS. 8. CONTRACTOR TO OBTAIN ALL PERMITS, PAY PERMIT FEES, AND BE RESPONSIBLE FOR SCHEDULING INSPECTIONS. 1.12 INSURANCE AND BONDS 3. NO PLEA OF IGNORANCE OF CONDITIONS THAT EXIST, OR OF DIFFICULTIES OR CONDITIONS 1. CONTRACTOR SHALL AT THEIR OWN EXPENSE CARRY AND MAINTAIN FOR THE DURATION OF 9. COMPLETE JOB SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR AFTER THE DATE OF THAT MAY BE ENCOUNTERED OR OF ANY OTHER RELEVANT MATTER CONCERNING THE WORK THE PROJECT ALL INSURANCE AS REQUIRED AND LISTED AND SHALL NOT COMMENCE WITH JOB ACCEPTANCE BY OWNER. ANY WORK, MATERIAL OR EQUIPMENT FOUND TO BE FAULTY TO BE PERFORMED IN THE EXECUTION OF THE WORK WILL BE ACCEPTED AS AN EXCUSE FOR THEIR WORK UNTIL THEY HAVE PRESENTED AN ORIGINAL CERTIFICATE OF INSURANCE DURING THAT PERIOD SHALL BE CORRECTED AT ONCE, UPON WRITTEN NOTIFICATION, AT THE ANY FAILURE OR OMISSION ON THE PART OF THE CONTRACTOR TO FULFILL EVERY DETAIL OF STATING ALL COVERAGES TO THE OWNER. REFER TO THE MASTER AGREEMENT FOR EXPENSE OF THE CONTRACTOR. ALL THE REQUIREMENTS OF THE CONTRACT DOCUMENTS GOVERNING THE WORK. REQUIRED INSURANCE LIMITS. 10. ALL CONDUIT SHALL HAVE A PULL WIRE OR ROPE. 1.3 CONTRACTS AND WARRANTIES 2. THE OWNER SHALL BE NAMED AS AN ADDITIONAL INSURED ON ALL POLICIES. 1. CONTRACTOR IS RESPONSIBLE FOR APPLICATION AND PAYMENT OF CONTRACTOR LICENSES 11. PROVIDE PROJECT MANAGER WITH ONE SET OF COMPLETE ELECTRICAL "AS INSTALLED" AND BONDS. 3. CONTRACTOR MUST PROVIDE PROOF OF INSURANCE. DRAWINGS AT THE COMPLETION OF THE JOB, SHOWING ACTUAL DIMENSIONS, ROUTINGS AND CIRCUITS. JEFFERY S. GUTOWSKY, PROFESSIONAL ENGINEER STATE OF ILLINOIS 1.4 STORAGE 12. ALL BROCHURES, OPERATING MANUALS, CATALOGS, SHOP DRAWINGS, ETC., SHALL BE LICENSE # 062-047235 1. ALL MATERIALS MUST BE STORED IN A LEVEL AND DRY FASHION AND IN A MANNER THAT DOES TURNED OVER TO THE OWNER AT JOB COMPLETION. EXPIRES 11/30/17 SIGNED: 12/13/17 NOT NECESSARILY OBSTRUCT THE FLOW OF OTHER WORK. ANY STORAGE METHOD MUST 1.1 REQUIREMENTS OF REGULATOR AGENCIES MEET ALL RECOMMENDATIONS OF THE ASSOCIATED MANUFACTURER. 1. FURNISH U.L. LISTED EQUIPMENT WHERE SUCH LABEL IS AVAILABLE, INSTALL IN 13. USE T-TAP CONNECTIONS ON ALL MULTI-CIRCUITS WITH COMMON NEUTRAL CONDUCTOR FOR DATE: DESCRIPTION: BY: REV: CONFORMANCE WITH U.L. STANDARDS WHERE APPLICABLE. LIGHTING FIXTURES. 09/14/16 FOR CLIENT REVIEW WCD A 2. THE BTS MUST BE STORED INSIDE UNTIL THERE IS POWER ON SITE. 2. INSTALL ANTENNA, ANTENNA CABLES, GROUNDING SYSTEM IN ACCORDANCE WITH DRAWINGS 14. ALL CONDUCTORS SHALL BE COPPER. 11/08/16 FINALS RSM 0 1.5 CLEAN UP AND SPECIFICATION IN EFFECT AT PROJECT LOCATION AND RECOMMENDATIONS OF STATE 1. THE CONTRACTORS SHALL AT ALL TIMES KEEP THE SITE FREE FROM ACCUMULATION OF AND LOCAL BUILDING CODES, SPECIAL CODES HAVING JURISDICTION OVER SPECIFIC 15. ALL CIRCUIT BREAKERS, FUSES AND ELECTRICAL EQUIPMENT SHALL HAVE AN INTERRUPTING WASTE MATERIALS OR RUBBISH CAUSED BY THEIR EMPLOYEES AT WORK AND AT THE PORTIONS OF WORK. THIS INCLUDES BUT IS NOT LIMITED TO THE FOLLOWING: SHORT CIRCUIT CURRENT TO WHICH THEY MAY BE SUBJECTED, AND A MINIMUM OF 10,000 03/01/17 RFDS REVISION RSM 1 COMPLETION OF THE WORK, THEY SHALL REMOVE ALL RUBBISH FROM AND ABOUT THE A.I.C. BUILDING AREA, INCLUDING ALL THEIR TOOLS, SCAFFOLDING AND SURPLUS MATERIALS AND A. TIA - TELECOMMUNICATIONS INDUSTRY ASSOCIATION TIA-222-G. STRUCTURAL 12/13/17 REVISION BLW 2 SHALL LEAVE THEIR WORK CLEAN AND READY FOR USE. STANDARDS FOR STEEL ANTENNA TOWERS AND ANTENNA SUPPORTING STRUCTURES. 16. THE ENTIRE ELECTRICAL INSTALLATION SHALL BE GROUNDED AS REQUIRED BY ALL APPLICABLE CODES. 2. EXTERIOR: VISUALLY INSPECT EXTERIOR SURFACES AND REMOVE ALL TRACES OF SOIL, B. FAA - FEDERAL AVIATION ADMINISTRATION ADVISORY CIRCULAR AC 70/7460-IH, WASTE MATERIALS, SMUDGES AND OTHER FOREIGN MATTER. OBSTRUCTION MARKING AND LIGHTING. 17. PATCH, REPAIR AND PAINT ANY AREA THAT HAS BEEN DAMAGED IN THE COURSE OF THE ELECTRICAL WORK. A. REMOVE ALL TRACES OF SPLASHED MATERIALS FROM ADJACENT SURFACES. C. FCC - FEDERAL COMMUNICATIONS COMMISSION RULES AND REGULATIONS FORM 715, OBSTRUCTION MARKING AND LIGHTING SPECIFICATIONS FOR ANTENNA STRUCTURES 18. PENETRATIONS IN FIRE RATED WALLS SHALL BE FIRE STOPPED IN ACCORDANCE WITH B. IF NECESSARY TO ACHIEVE A UNIFORM DEGREE OF CLEANLINESS, HOSE DOWN THE AND FORM 715A, HIGH INTENSITY OBSTRUCTION LIGHTING SPECIFICATIONS FOR APPLICABLE LOCAL BUILDING CODES. EXTERIOR OF THE STRUCTURE. ANTENNA STRUCTURES. 19. WIRE AND CABLE CONDUCTORS SHALL BE COPPER #12 AWG MINIMUM UNLESS SPECIFICALLY 3. INTERIOR: VISUALLY INSPECT INTERIOR SURFACE AND REMOVE ALL TRACES OF SOIL, WASTE D. AISC - AMERICAN INSTITUTE OF STEEL CONSTRUCTION SPECIFICATION FOR NOTED OTHERWISE ON DRAWINGS. MATERIALS, SMUDGES AND OTHER FOREIGN MATTER FROM WALLS/FLOOR/CEILING. STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS. 20. GROUNDING CONDUCTORS SHALL BE SOLID TINNED COPPER UNLESS OTHERWISE NOTED. A. REMOVE ALL TRACES OF SPLASHED MATERIAL FROM ADJACENT SURFACES. E. NEC - NATIONAL ELECTRICAL CODE - ON TOWER LIGHTING KITS. 21. ALL MATERIALS SHALL BE U.L. LISTED. B. REMOVE PAINT DROPPINGS, SPOTS, STAINS AND DIRT FROM FINISHED SURFACES. F. UL - UNDERWRITER'S LABORATORIES APPROVED ELECTRICAL PRODUCTS. 22. CONDUIT G. IN ALL CASES, PART 77 OR THE FAA RULES AND PARTS 17 AND 22 OF THE FCC RULES ARE 1.6 CHANGE ORDER PROCEDURE APPLICABLE AND IN THE EVENT OF CONFLICT, SUPERSEDE ANY OTHER STANDARDS OR A. RIGID CONDUIT SHALL BE U.L. LABEL GALVANIZED ZINC COATED WITH ZINC INTERIOR 1. CHANGE ORDERS MAY BE INITIATED BY THE OWNER AND/OR THE CONTRACTOR INVOLVED. THE SPECIFICATIONS. AND SHALL BE USED WHEN INSTALLED IN OR UNDER CONCRETE SLABS IN CONTACT CONTRACTOR, UPON VERBAL REQUEST FROM THE OWNER SHALL PREPARE A WRITTEN WITH THE EARTH, UNDER PUBLIC ROADWAYS, IN MASONRY WALLS OR EXPOSED ON PROPOSAL DESCRIBING THE CHANGE IN WORK OR MATERIALS AND ANY CHANGES IN THE H. 2012 LIFE SAFETY CODE NFPA -101. BUILDING EXTERIOR. RIGID CONDUIT IN CONTACT WITH EARTH SHALL BE 1/2 LAPPED CONTRACT AMOUNT AND PRESENT TO THE OWNER WITHIN 72 HRS FOR APPROVAL. SUBMIT WRAPPED WITH HUNTS WRAP PROCESS NO. 3 REQUESTS FOR SUBSTITUTIONS IN THE FORM AND IN ACCORDANCE WITH PROCEDURES REQUIRED FOR CHANGE ORDER PROPOSALS. ANY CHANGES IN SCOPE OF WORK OR B. ELECTRICAL METALLIC TUBING SHALL HAVE U.L. LABEL, FITTING SHALL BE GLAND RING MATERIALS WHICH ARE PERFORMED BY THE CONTRACTOR WITHOUT A WRITTEN CHANGE COMPRESSION TYPE. EMT SHALL BE USED ONLY FOR INTERIOR RUNS. ORDER AS DESCRIBED AND APPROVED BY THE OWNER SHALL PLACE FULL RESPONSIBILITY OF THESE ACTIONS ON THE CONTRACTOR. C. FLEXIBLE METALLIC CONDUIT SHALL HAVE U.L. LISTED LABEL AND MAY BE USED WHERE 1.7 RELATED DOCUMENTS AND COORDINATION PERMITTED BY CODE. FITTINGS SHALL BE "JAKE" OR "SQUEEZE" TYPE, SEAL TIGHT 1. GENERAL CARPENTRY, ELECTRICAL AND ANTENNA DRAWINGS ARE INTERRELATED. IN FLEXIBLE CONDUIT. ALL CONDUIT SHALL HAVE FULL SIZE EQUIPMENT GROUND WIRE. PERFORMANCE OF THE WORK, THE CONTRACTOR MUST REFER TO ALL DRAWINGS. ALL COORDINATION TO BE THE RESPONSIBILITY OF THE CONTRACTOR. D. CONDUIT RUNS SHALL BE SURFACE MOUNTED UNLESS INDICATED OTHERWISE. CONDUIT SITE INFORMATION: 1.8 SHOP DRAWINGS INDICATED SHALL RUN PARALLEL OR AT RIGHT ANGLES TO CEILING, FLOOR OR BEAMS. VERIFY EXACT ROUTING OF ALL EXPOSED CONDUIT WITH THE OWNER PRIOR TO INSTALLING. NO HORIZONTAL CONDUITS SHALL BE BELOW 7'-6" A.F.F. NO BX OR ROMEX GOLDEN YEARS 1. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AS REQUIRED AND LISTED IN THESE SPECIFICATIONS TO THE OWNER FOR APPROVAL. CABLE IS PERMITTED. PLAZA E. PARALLEL UNDERGROUND CONDUIT SHALL BE PVC SCHEDULE 40 (UNLESS NOTED 2. ALL SHOP DRAWINGS SHALL BE REVIEWED, CHECKED AND CORRECTED BY CONTRACTOR PRIOR TO SUBMITTAL TO THE OWNER. OTHERWISE) AT A MINIMUM DEPTH OF 30" BELOW GRADE - STACKED UNDERGROUND CONDUIT SHALL BE PVC SCHEDULE 40 (UNLESS NOTED OTHERWISE) AT A MINIMUM DEPTH OF 24" BELOW GRADE. CH17481C 1.9 PRODUCTS AND SUBSTITUTIONS 1. SUBMIT 3 COPIES OF EACH REQUEST FOR SUBSTITUTION. IN EACH REQUEST IDENTIFY THE F. ABOVE GROUND CONDUIT SHALL BE P.V.C. SCHEDULE 80 (UNLESS NOTED OTHERWISE). 507 E. TAYLOR ST. PRODUCT OR FABRICATION OR INSTALLATION METHOD TO BE REPLACED BY THE DEKALB, IL 60115 23. ALL ELECTRICAL EQUIPMENT SHALL BE LABELED WITH PERMANENT ENGRAVED PLASTIC SUBSTITUTION. INCLUDE RELATED SPECIFICATION SECTION AND DRAWING NUMBERS AND LABELS. W-T JOB NUMBER: T1601208 COMPLETE DOCUMENTATION SHOWING COMPLIANCE WITH THE REQUIREMENTS FOR SUBSTITUTIONS. SHEET TITLE: 24. UPON COMPLETION OF WORK, CONDUCT CONTINUITY, SHORT CIRCUIT, AND FALL OF POTENTIAL GROUND TESTS FOR APPROVAL. SUBMIT TEST REPORTS TO PROJECT MANAGER. 2. SUBMIT ALL NECESSARY PRODUCT DATA AND CUT SHEETS WHICH PROPERLY INDICATE AND CLEAN PREMISES OF ALL DEBRIS RESULTING FROM WORK AND LEAVE WORK IN A COMPLETE DESCRIBE THE ITEMS, PRODUCTS AND MATERIALS BEING INSTALLED. THE CONTRACTOR AND UNDAMAGED CONDITION. SHALL, IF DEEMED NECESSARY BY THE OWNER SUBMIT ACTUAL SAMPLES TO THE OWNER FOR APPROVAL IN LIEU OF CUT SHEETS. 1.10 QUALITY ASSURANCE 1. ALL WORK SHALL BE IN ACCORDANCE WITH APPLICABLE LOCAL, STATE AND FEDERAL REGULATIONS. SHEET NUMBER: PLOT SCALE: 1:1 @ 11"x17" IMPORTANT SITE NOTES: 1. GENERAL CONTRACTOR WILL NOT START CONSTRUCTION UNTIL AFTER THEY HAVE RECEIVED 8550 BRYN MAWR AVENUE, SUITE 100 THE PRE-CON PACKAGE AND HAVE A PRE-CON CHICAGO, ILLINOIS 60631 WALK WITH THE PROJECT MANAGER. PLANS PREPARED BY: 2. GENERAL CONTRACTOR TO HIRE PUBLIC (811) AND PRIVATE LOCATING SERVICE IN ORDER TO LOCATE AND PROTECT ALL SURFACE UTILITIES. DO NOT SCALE OFF THESE PLANS FOR ANY BELOW GRADE UTILITIES. 3. CONTRACTOR SHALL VERIFY ALL EXISTING BURIED AND OVERHEAD UTILITIES PRIOR TO EXCAVATION. CONTRACTOR SHALL REPAIR ALL DAMAGED UTILITIES AT HIS OWN COST AND COORDINATE ANY 2675 Pratum Avenue Hoffman Estates, Illinois 60192 REPAIRS WITH RESPECTIVE UTILITY COMPANY. PH: (224) 293-6333 FAX: (224) 293-6444 EXISTING www.wtengineering.com BUILDING IL. License No.: 184.007570-0015 Exp: 04/30/19 4. CONTRACTOR TO VERIFY ALL HEIGHTS AND AZIMUTHS IN FIELD PRIOR TO CONSTRUCTION. C CONTRACTOR SHALL NOTIFY T-MOBILE AND ENGINEERING FIRM OF ANY DISCREPANCIES SEAL: BEFORE PROCEEDING. 5. CONTRACTOR SHALL RESTORE AND REPAIR ANY DAMAGED AREAS CAUSED BY CONSTRUCTION. EXISTING TREE (TYP.) JEFFERY S. GUTOWSKY, PROFESSIONAL ENGINEER EXISTING EXISTING ASPHALT STATE OF ILLINOIS LICENSE # 062-047235 GRASS AREA PARKING LOT EXPIRES 11/30/17 SIGNED: 12/13/17 DATE: DESCRIPTION: BY: REV: 09/14/16 FOR CLIENT REVIEW WCD A EXISTING BUILDING 11/08/16 FINALS RSM 0 ROOFTOP. SEE C-1.1 2 03/01/17 RFDS REVISION RSM 1 12/13/17 REVISION BLW 2 EXISTING RESIDENCE EXISTING EXISTING BUILDING BUILDING EXISTING CONCRETE SIDEWALK (TYP.) SITE INFORMATION: GOLDEN YEARS PLAZA CH17481C 507 E. TAYLOR ST. DEKALB, IL 60115 W-T JOB NUMBER: T1601208 EXISTING SHEET TITLE: GRASS AREA SHEET NUMBER: PLOT SCALE: 1:1 @ 11"x17" 8550 BRYN MAWR AVENUE, SUITE 100 CHICAGO, ILLINOIS 60631 PLANS PREPARED BY: 2675 Pratum Avenue Hoffman Estates, Illinois 60192 PH: (224) 293-6333 FAX: (224) 293-6444 www.wtengineering.com IL. License No.: 184.007570-0015 Exp: 04/30/19 EXISTING ALPHA ANTENNA SECTOR. C SEE A-2 EXISTING CARRIER ANTENNA MOUNT SEAL: (TYP.) EXISTING CARRIER PLATFORM JEFFERY S. GUTOWSKY, EXISTING PROFESSIONAL ENGINEER STATE OF ILLINOIS CARRIER LICENSE # 062-047235 EXPIRES 11/30/17 SIGNED: 12/13/17 PLATFORM DATE: DESCRIPTION: BY: REV: 09/14/16 FOR CLIENT REVIEW WCD A 11/08/16 FINALS RSM 0 03/01/17 RFDS REVISION RSM 1 12/13/17 REVISION BLW 2 EXISTING CARRIER EXISTING PLATFORM PENTHOUSE EXISTING ROOFTOP EQUIPMENT PLATFORM. SEE C-2 EXISTING BETA ANTENNA SECTOR. SEE A-2 EXISTING CARRIER SITE INFORMATION: ANTENNA MOUNT (TYP.) GOLDEN YEARS PLAZA CH17481C EXISTING GAMMA ANTENNA SECTOR. 507 E. TAYLOR ST. SEE A-2 DEKALB, IL 60115 W-T JOB NUMBER: T1601208 SHEET TITLE: SHEET NUMBER: PLOT SCALE: 1:1 @ 11"x17" 2 EXISTING EQUIPMENT REMOVED EQUIPMENT 8550 BRYN MAWR AVENUE, SUITE 100 CHICAGO, ILLINOIS 60631 RELOCATED EQUIPMENT PLANS PREPARED BY: NEW EQUIPMENT EXISTING T-MOBILE EQUIPMENT CABINET & PLINTH 2675 Pratum Avenue Hoffman Estates, Illinois 60192 PH: (224) 293-6333 FAX: (224) 293-6444 www.wtengineering.com IL. License No.: 184.007570-0015 Exp: 04/30/19 C SEAL: EXISTING (1) GSM ESMB, (1) UMTS FSME, & (1) LTE FSMF WITH (1) FBBC ON TOP OF SITE SUPPORT CABINET. (1) GSM ESMB, (1) UMTS FSME, (1) INSTALL (1) ADDITIONAL FBBC IN EXISTING LTE FSMF WITH (2) FBBC EXISTING LTE FSMF ON TOP OF SITE SUPPORT CABINET. EXISTING DISCONNECT EXISTING PPC EXISTING SITE SUPPORT CABINET: EXISTING SITE SUPPORT CABINET: REPLACE EXISTING CSR 7705 SAR-F WITH NEW NEW CSR 7705 SAR-M SAR-M EXISTING COVP DC BREAKER JEFFERY S. GUTOWSKY, REPLACE EXISTING UMTS FSME DC BREAKER 63A UMTS FSMF DC BREAKER PROFESSIONAL ENGINEER STATE OF ILLINOIS WITH NEW 63A BREAKER (AS NEEDED) 63A LTE FSMF DC BREAKER LICENSE # 062-047235 EXPIRES 11/30/17 SIGNED: 12/13/17 REPLACE EXISTING LTE FSMF DC BREAKER 10A LTE PCS FSMF DC BREAKER PLAT EXISTING CABLE TRAY WITH NEW 63A DC BREAKER (AS NEEDED) DATE: DESCRIPTION: BY: REV: FORM 09/14/16 FOR CLIENT REVIEW WCD A 11/08/16 FINALS RSM 0 03/01/17 RFDS REVISION RSM 1 12/13/17 REVISION BLW 2 EXISTING COVP UTILIZE EXISTING UTILIZE EXISTING HCS CABLES HCS CABLES EXISTING NODE B MODULES EXISTING T-MOBILE EQUIPMENT PLATFORM FORM PLAT X ISTING EXISTING E ROOFTOP SITE INFORMATION: GOLDEN YEARS PLAZA CH17481C 507 E. TAYLOR ST. DEKALB, IL 60115 W-T JOB NUMBER: T1601208 SHEET TITLE: SHEET NUMBER: PLOT SCALE: 1:1 @ 11"x17" NEW EXISTING ANTENNA T-MOBILE ANTENNA. NEW T-MOBILE SEE A-2 REMOVED ANTENNA 8550 BRYN MAWR AVENUE, SUITE 100 CHICAGO, ILLINOIS 60631 ANTENNA. SEE A-2 RELOCATED ANTENNA PLANS PREPARED BY: NEW ANTENNA IMPORTANT SITE NOTES: 2675 Pratum Avenue 1. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING Hoffman Estates, Illinois 60192 PH: (224) 293-6333 FAX: (224) 293-6444 FINAL RF CONFIGURATION AND NOTIFY T-MOBILE AND www.wtengineering.com ENGINEERING FIRM WITH ANY DISCREPANCIES. IL. License No.: 184.007570-0015 Exp: 04/30/19 C 2. CONTRACTOR SHALL VERIFY ALL FINAL CONNECTION LOCATIONS WITH T-MOBILE ENGINEER, RF ENGINEER, SEAL: AND NET-OPS PRIOR TO INSTALLATION. 3. CONTRACTOR TO USE PROPER TORQUE WRENCH WHEN INSTALLING AND TIGHTENING CONNECTORS TO INSURE PROPER FIT. 4. CONTRACTOR TO ARRANGE NEW MODULES/EQUIPMENT 2 TO AVOID INTERFERING WITH SAFETY CLIMB. NOTE: A STRUCTURAL ANALYSIS OF THE TOWER OR STRUCTURE JEFFERY S. GUTOWSKY, HAS BEEN COMPLETED BY TAE, INC ON 11/08/16. THE PROFESSIONAL ENGINEER STATE OF ILLINOIS LOCATION AND MOUNTING SHOWN IN THE STRUCTURAL LICENSE # 062-047235 TOP OF PENTHOUSE T-MOBILE ANTENNAS, ANALYSIS SHALL SUPERSEDE THESE DRAWINGS. EXPIRES 11/30/17 SIGNED: 12/13/17 COVP, & RRU'S. SEE A-2 DATE: DESCRIPTION: BY: REV: 09/14/16 FOR CLIENT REVIEW WCD A EXISTING/NEW T-MOBILE ANTENNAS 11/08/16 FINALS RSM 0 TOP OF PARAPET 03/01/17 RFDS REVISION RSM 1 12/13/17 REVISION BLW 2 EXISTING BUILDING SITE INFORMATION: GOLDEN YEARS PLAZA CH17481C 507 E. TAYLOR ST. DEKALB, IL 60115 W-T JOB NUMBER: T1601208 SHEET TITLE: GRADE SHEET NUMBER: PLOT SCALE: 1:1 @ 11"x17" 2 EXISTING ANTENNA SECTOR ALPHA BETA GAMMA LOCATION A-4 A-3 A-2 A-1 B-4 B-3 B-2 B-1 C-4 C-3 C-2 C-1 8550 BRYN MAWR AVENUE, SUITE 100 CHICAGO, ILLINOIS 60631 TECHNOLOGY LTE AWS DUMMY LTE 700 GSM-UMTS PCS LTE AWS DUMMY LTE 700 GSM-UMTS PCS LTE AWS DUMMY LTE 700 GSM-UMTS PCS REMOVED ANTENNA PLANS PREPARED BY: AZIMUTH RAD CENTER NEW ANTENNA EX. ANDREW EX. EMS COMMSCOPE EX. ANDREW EX. ANDREW EX. EMS COMMSCOPE EX. ANDREW EX. ANDREW EX. EMS COMMSCOPE EX. ANDREW ANTENNA MODEL # TMBXX-6517-A2M RR65-19-00 SBNH-1D65C TMBXX-6517-A2M TMBXX-6517-A2M RR65-19-00 SBNH-1D65C TMBXX-6517-A2M TMBXX-6517-A2M RR65-19-00 SBNH-1D65C TMBXX-6517-A2M MECHANICAL DOWNTILT EXISTING EXISTING 4 EXISTING EXISTING EXISTING 4 EXISTING EXISTING EXISTING 4 EXISTING REMOVED TMA 2675 Pratum Avenue ELECTRICAL DOWNTILT 5/5 - 7 5/5 4/4 - 3 1/1 1/1 - 7 5/5 Hoffman Estates, Illinois 60192 PH: (224) 293-6333 FAX: (224) 293-6444 RRU TYPE EX. FRIG - FRBG EX. FXFB EX. FRIG - FRBG EX. FXFB EX. FRIG - FRBG EX. FXFB www.wtengineering.com NEW TMA IL. License No.: 184.007570-0015 Exp: 04/30/19 FIBER JUMPER LENGTH EXISTING - EXISTING EXISTING - EXISTING EXISTING - EXISTING C RF JUMPER LENGTH EXISTING - EXISTING EXISTING - EXISTING EXISTING - EXISTING FRIG EXISTING FRIG SEAL: EX. LOW-CAP SHARED ALPHA SHARED ALPHA EX. LOW-CAP SHARED BETA SHARED BETA EX. LOW-CAP SHARED SHARED HCS & COAX - - - HCS CABLE HCS HCS HCS CABLE HCS HCS HCS CABLE GAMMA HCS GAMMA HCS COVP EXISTING COVP HCS LENGTH 125'-0" - - - 25'-0" - - - 75'-0" - - - NOTE: NOTE: NOTE: A STRUCTURAL ANALYSIS OF THE TOWER OR STRUCTURE ANTENNA INFORMATION OBTAINED FROM T-MOBILE RF CONTRACTOR TO REPLACE EXISTING REMOVED FXFB HAS BEEN COMPLETED BY TAE, INC ON 11/08/16. THE DATA CONFIGURATION SHEET DATED 07/21/2016. ANTENNA MAST PIPE WITH NEW 8'-0" MAST LOCATION AND MOUNTING SHOWN IN THE STRUCTURAL CONTRACTOR TO OBTAIN THE MOST CURRENT RFDS PIPE TO ACCOMMODATE NEW 8'-0" QUAD ANALYSIS SHALL SUPERSEDE THESE DRAWINGS. FROM T-MOBILE PRIOR TO CONSTRUCTION ANTENNA (TYP. OF 1 PER SECTOR). JEFFERY S. GUTOWSKY, PROFESSIONAL ENGINEER STATE OF ILLINOIS LICENSE # 062-047235 RELOCATED FXFB EXPIRES 11/30/17 SIGNED: 12/13/17 EXISTING DUMMY DATE: DESCRIPTION: BY: REV: ANTENNA TO REMAIN EXISTING DUMMY 09/14/16 FOR CLIENT REVIEW WCD A ANTENNA TO REMAIN EXISTING ANTENNA EXISTING ANTENNA TO BE NEW ANTENNA TO BE INSTALLED 11/08/16 FINALS RSM 0 NEW FRBG TO REMAIN EXISTING ANTENNA REMOVED & REPLACED ON NEW PIPE MOUNT EXISTING FRIG TO REMAIN 03/01/17 RFDS REVISION RSM 1 EXISTING ANTENNA EXISTING ANTENNA A-4 A-3 A-2 A-1 EXISTING FRIG A-4 A-3 A-2 A-1 12/13/17 REVISION BLW 2 TO REMAIN TO REMAIN EXISTING FXFB EXISTING COVP TO REMAIN EXISTING COVP ALPHA ALPHA EXISTING FXFB SECTOR EXISTING TMA SECTOR TO REMAIN TO BE REMOVED 2 2 NEW FRBG TO BE INSTALLED ON NEW PIPE MOUNT NEW FRBG TO BE EXISTING FRIG INSTALLED ON EXISTING FRIG NEW PIPE MOUNT EXISTING ANTENNA EXISTING ANTENNA EXISTING ANTENNA EXISTING ANTENNA TO REMAIN TO REMAIN TO REMAIN TO REMAIN B-4 B-4 C- GAMMA EXISTING DUMMY C- GAMMA EXISTING DUMMY 1 BETA 1 BETA SECTOR ANTENNA TO REMAIN SECTOR ANTENNA TO REMAIN SECTOR SECTOR SITE INFORMATION: 3 B- B-3 2 2 EXISTING TMA 2 2 NEW FRBG TO BE INSTALLED EXISTING FXFB TO REMAIN C- 2 TO BE REMOVED EXISTING FXFB TO REMAIN C- 2 ON NEW PIPE MOUNT GOLDEN YEARS EXISTING ANTENNA TO BE B- 2 NEW ANTENNA TO B-2 PLAZA REMOVED & REPLACED C- EXISTING TMA C- 3 BE INSTALLED ON 3 TO BE REMOVED EXISTING COVP B- EXISTING ANTENNA TO BE NEW PIPE MOUNT EXISTING COVP B-1 NEW ANTENNA TO BE INSTALLED CH17481C 1 REMOVED & REPLACED ON NEW PIPE MOUNT 4 4 C- EXISTING FXFB TO C- EXISTING FXFB TO EXISTING FRIG EXISTING FRIG 507 E. TAYLOR ST. REMAIN REMAIN DEKALB, IL 60115 EXISTING ANTENNA EXISTING ANTENNA EXISTING ANTENNA EXISTING ANTENNA W-T JOB NUMBER: T1601208 EXISTING DUMMY TO REMAIN EXISTING DUMMY TO REMAIN ANTENNA TO REMAIN TO REMAIN ANTENNA TO REMAIN TO REMAIN SHEET TITLE: SHEET NUMBER: PLOT SCALE: 1:1 @ 11"x17" 8550 BRYN MAWR AVENUE, SUITE 100 CHICAGO, ILLINOIS 60631 PLANS PREPARED BY: 2675 Pratum Avenue Hoffman Estates, Illinois 60192 PH: (224) 293-6333 FAX: (224) 293-6444 www.wtengineering.com IL. License No.: 184.007570-0015 Exp: 04/30/19 C SEAL: JEFFERY S. GUTOWSKY, PROFESSIONAL ENGINEER STATE OF ILLINOIS LICENSE # 062-047235 EXPIRES 11/30/17 SIGNED: 12/13/17 DATE: DESCRIPTION: BY: REV: 09/14/16 FOR CLIENT REVIEW WCD A 11/08/16 FINALS RSM 0 03/01/17 RFDS REVISION RSM 1 12/13/17 REVISION BLW 2 JUMPERS TO BE TORQUED TO 221.27 NEW TOWER STANDOFF IN/LBS KIT. SITE PRO PART # STK3 (2) NEW BARREL CUSHIONS. SITE PRO PART # BC124 CABLE TIE 50MM 20MM NEW COAX BLOCK MOUNTING HARDWARE. SITE PRO PART # CH50 SITE INFORMATION: GOLDEN YEARS (1) WRAP OF INSULATION PLAZA TAPE (OVERLAPPING 50%) (2) STRETCH WRAPPED CH17481C WRAPS OF SELF AMALGAMATING TAPE 507 E. TAYLOR ST. (STRETCH 30%, DEKALB, IL 60115 OVERLAPPING 50%) W-T JOB NUMBER: T1601208 NEW COAX BLOCK. SITE PRO PART # CXB158 SHEET TITLE: (3) WRAPS OF INSULATION EXISTING MOUNTING PIPE TAPE (OVERLAPPING 50%) SHEET NUMBER: PLOT SCALE: 1:1 @ 11"x17" 8550 BRYN MAWR AVENUE, SUITE 100 CHICAGO, ILLINOIS 60631 PLANS PREPARED BY: 2675 Pratum Avenue Hoffman Estates, Illinois 60192 PH: (224) 293-6333 FAX: (224) 293-6444 www.wtengineering.com IL. License No.: 184.007570-0015 Exp: 04/30/19 C SEAL: JEFFERY S. GUTOWSKY, PROFESSIONAL ENGINEER STATE OF ILLINOIS LICENSE # 062-047235 EXPIRES 11/30/17 SIGNED: 12/13/17 DATE: DESCRIPTION: BY: REV: 09/14/16 FOR CLIENT REVIEW WCD A 11/08/16 FINALS RSM 0 03/01/17 RFDS REVISION RSM 1 12/13/17 REVISION BLW 2 7.1" 11.9" DIMENSIONS, HxWxD: 96.5"x11.9"x7.1" ANTENNA WEIGHT: 49.6 lbs 96.5" 96.5" SITE INFORMATION: GOLDEN YEARS PLAZA CH17481C 507 E. TAYLOR ST. DEKALB, IL 60115 W-T JOB NUMBER: T1601208 SHEET TITLE: SHEET NUMBER: PLOT SCALE: 1:1 @ 11"x17" U U U N N N 8550 BRYN MAWR AVENUE, SUITE 100 LTE U GSM-UMTS LTE U GSM-UMTS LTE U GSM-UMTS CHICAGO, ILLINOIS 60631 LTE AWS DUMMY LTE AWS DUMMY LTE AWS DUMMY 700 S PCS 700 S PCS 700 S PCS E E E D D D PLANS PREPARED BY: 10 9 8 7 12 11 6 5 4 3 2 1 10 9 8 7 12 11 6 5 4 3 2 1 10 9 8 7 12 11 6 5 4 3 2 1 2675 Pratum Avenue Hoffman Estates, Illinois 60192 PH: (224) 293-6333 FAX: (224) 293-6444 www.wtengineering.com IL. License No.: 184.007570-0015 Exp: 04/30/19 FRIG FRBG FXFB FRIG FRBG FXFB FRIG FRBG FXFB C SEAL: JEFFERY S. GUTOWSKY, ALPHA BETA GAMMA PROFESSIONAL ENGINEER STATE OF ILLINOIS COVP COVP COVP LICENSE # 062-047235 EXPIRES 11/30/17 SIGNED: 12/13/17 DATE: DESCRIPTION: BY: REV: 09/14/16 FOR CLIENT REVIEW WCD A 11/08/16 FINALS RSM 0 03/01/17 RFDS REVISION RSM 1 12/13/17 REVISION BLW 2 ANTENNA LOCATION EQUIPMENT LOCATION FSEB EQUIPMENT COVP NOTE: CONTRACTOR TO OBTAIN THE MOST CURRENT RFDS FROM T-MOBILE PRIOR TO CONSTRUCTION FYGA FSMF & 2 FBBC (LTE AWS+700) ALPHA CABLES FSME BETA CABLES (UMTS PCS) GAMMA CABLES ESMC SITE INFORMATION: - INSTALL (3) NEW FRBG'S (1 PER SECTOR) RF JUMPER - REMOVE (3) EXISTING TMA'S (GSM PCS) - - REPLACE (3) EXISTING ANTENNAS WITH (3) NEW ANTENNAS (1 PER SECTOR) INSTALL NEW RF JUMPERS FOR NEW AND RELOCATED RRU'S MAIN POWER & FIBER GOLDEN YEARS - - UTILIZE EXISTING HCS INSTALL (1) ADDITIONAL FBBC IN EXISTING LTE FSMF RECTIFIERS POWER & FIBER JUMPER PLAZA - REPLACE EXISTING UMTS FSME DC BREAKER WITH NEW 63A DC BREAKER (AS NEEDED) - REPLACE EXISTING LTE FSMF DC BREAKER WITH NEW 63A DC BREAKER (AS NEEDED) - REPLACE EXISTING CSR 7705 SAR-F WITH NEW SAR-M 7705 (CSR) SAR-M ALARM CABLE CH17481C - SWEEP TEST EXISTING ANTENNA USED FOR FINAL BUILD AISG RET CABLE - RESTORE EXISTING GROUNDS AS NEEDED FOR EXISTING ANTENNAS USED FOR FINAL BUILD 507 E. TAYLOR ST. - OBTAIN CURRENT RFDS WITHIN 48 HOURS PRIOR TO CONSTRUCTION HYBRID CABLE - FOLLOW PORT MATRIX PER RF CONFIGURATION DEKALB, IL 60115 - FOLLOW CURRENT T-MOBILE STANDARD OPERATION PROCEDURE W-T JOB NUMBER: T1601208 - RETURN ALL UNUSED NEW & OLD EQUIPMENT MATERIALS/EQUIPMENT TO CTDI IN THE SAME COAX CABLE SHEET TITLE: CONDITION WHEN IT WAS REMOVED - PROVIDE CLOSEOUT PACKAGE WITHIN 72 HOURS AFTER SITE COMPLETION POWER - CLOSE ANY OPEN PERMITS AFTER SITE COMPLETION RELOCATED EQUIPMENT NEW EQUIPMENT EXISTING EQUIPMENT BATTERIES SHEET NUMBER: SITE SUPPORT CABINET PLOT SCALE: 1:1 @ 11"x17" 3.4 SURGE ARRESTOR GROUND BAR: THE PURPOSE OF THE SURGE ARRESTOR GROUND BAR IS FOR LIGHTING PROTECTION. THE SURGE ARRESTOR GROUND BAR IS A BENT (3" X 3" ) X 1/4" X 24" COPPER BAR. IT IS LOCATED ON THE WAVEGUIDE BRIDGE SUPPORT CLOSEST TO THE 1.0 DEFINITIONS EQUIPMENT. ONE FACE OF THE BAR SHALL HAVE A MINIMUM OF (28) 3/8" DIA. HOLES. HOLES NEW GROUNDING WIRE AGB: ANTENNA GROUND BAR SHALL BE IN PAIRS THAT ARE 1" CENTER TO CENTER. THE OTHER FACE SHALL HAVE 3/8" DIA. TYPICAL ANTENNA SECTOR HOLES AS REQUIRED TO ATTACH AND GROUND COAXIAL SURGE ARRESTORS. THE GROUND AWG: AMERICAN WIRE GAUGE BAR SHALL BE SUPPORTED BY MOUNTING BRACKETS WITH INSULATOR STANDOFFS. EXISTING GROUNDING WIRE EXISTING GROUND WIRE 8550 BRYN MAWR AVENUE, SUITE 100 CADWELDING: AN EXOTHERMIC WELDING PROCESS WHICH CREATES POSITIVE CONTACT OF 3.5 ANTENNA GROUNDING: EACH ANTENNA COAXIAL CABLE SHALL TYPICALLY BE GROUNDED EXOTHERMIC WELD CHICAGO, ILLINOIS 60631 POSITIVE CONTACT OF GROUNDING CONDUCTORS AT THREE POINTS USING A HARD-SHELL COAXIAL CABLE KIT FROM THE MANUFACTURER OF (TYP. OF 1 PER ANTENNA PIPE MOUNT) EMT: ELECTRICAL METAL TUBING (LIGHT GAUGE METALLIC CONDUIT) THE ANTENNA CABLE. A TYPICAL INSTALLATION SHALL BE AS FOLLOWS: NEW #2 AWG SOLID TINNED GROUND WIRE MECHANICAL CONNECTION/DOUBLE HOLE PLANS PREPARED BY: A. THE FIRST GROUND CONNECTION SHALL OCCUR AS CLOSE TO THE ANTENNA AS FROM NEW ANTENNA MAST PIPE TO LUG TYPE CONNECTION MGB: MASTER GROUND BAR POSSIBLE, BELOW THE FIRST POINT THE COAX CABLE BEGINS TO RUN VERTICAL ANTENNA SECTOR GROUND BAR (TYP.) PVC: POLYVINYL CHLORIDE CONDUIT DOWN THE TOWER. THIS GROUND SHALL TERMINATE DIRECT TO THE TOP AGB. ON A EXISTING ANTENNA/EQUIPMENT T/I, GROUND TO THE AGB AT THE ANTENNA MOUNTS. NEW #6 AWG STRANDED GREEN JACKETED RFI: RADIO FREQUENCY INTERFERENCE GROUND WIRE TO NEW FRBG FROM B. THE SECOND GROUND SHALL BE MADE AT THE BOTTOM OF THE VERTICAL RUN OF TGB: TOWER GROUND BAR ANTENNA SECTOR GROUND BAR (TYP.) RELOCATED ANTENNA/EQUIPMENT THE COAXIAL CABLE AS IT TURNS OUT AWAY FROM THE TOWER TOWARDS THE BTS. THIS GROUND SHALL BE TERMINATED AT THE TGB. THE TGB SHALL HAVE TWO (2) FRBG THWN: LETTER TYPE DESIGNATION FOR CONDUCTOR INSULATION THAT IS A MOISTURE AND HEAT LEADS OF #2 AWG BARE TINNED SOLID COPPER WIRE, AND SHALL TERMINATE AT THE RESISTANT THERMOPLASTIC WITH A MAXIMUM OPERATING TEMPERATURE OF 75 DEGREES TOWER GROUND RING. THESE SHALL BE ENCASED IN PVC PIPE. NEW ANTENNA/EQUIPMENT CELSIUS OR 167 DEGREES FAHRENHEIT T/I: TENANT IMPROVEMENT C. THE THIRD GROUND SHALL BE ON THE SURGE ARRESTOR. GROUND TO BE ATTACHED 2675 Pratum Avenue TO THE CABLE ON STRAIGHT RUNS (NOT WITHIN BENDS) AND BE WEATHERPROOFED Hoffman Estates, Illinois 60192 PH: (224) 293-6333 FAX: (224) 293-6444 2.0 BACKGROUND PER THE MANUFACTURER'S SPECIFICATIONS. THE SURGE ARRESTORS SHALL BE www.wtengineering.com GROUNDED TO THE GROUND BAR. THE SAGB SHALL HAVE TWO (2) LEADS OF #2 AWG EXISTING ANTENNA GROUND BAR IL. License No.: 184.007570-0015 Exp: 04/30/19 2.1 AREAS OF CONCERN: WHEN DESIGNING A GROUNDING SYSTEM FOR A MOBILE RADIO BARE TINNED SOLID COPPER WIRE, AND SHALL TERMINATE AT THE TOWER GROUND (TYP. 1 PER SECTOR) NOTES: FACILITY THERE ARE FOUR INTERRELATED AREAS OF CONCERN. THE BASIC OBJECTIVE RING. THESE SHALL BE ENCASED IN PVC PIPE. SYSTEM MODULES TO SYSTEM MODULE PLINTH: C FOR EACH IS: #6 AWG STRANDED GREEN JACKETED GROUND WIRE 3.6 EXOTHERMIC WELD & BURNDY CONNECTIONS SEAL: 1. LIGHTNING PROTECTION -TO MAINTAIN ALL EQUIPMENT AT THE SAME POTENTIAL EXOTHERMIC WELDS AND BURNDY CONNECTIONS SHALL BOND ALL UNDERGROUND AND DURING A LIGHTNING IMPULSE. DAMP LOCATION CONNECTIONS, SHELTER SKID GROUNDS, TOWER OR MONOPOLE EXISTING GROUND WIRES DELTA SSC TO SSC PLINTH: GROUNDS, FENCING CORNER AND GATE POSTS, ANTENNA GROUND BARS, (AGB) SURGE #2 AWG STRANDED GREEN JACKETED GROUND WIRE 2. RFI FOR NOISE INDUCTION CONTROL -TO ESTABLISH THE LOWEST POSSIBLE ARRESTER GROUND BAR, AND THE MASTER GROUND BAR (MGB). MECHANICAL IMPEDANCE AMONG ALL EQUIPMENT. CONNECTIONS SHALL BE TYPICALLY USED TO BOND ALL INTERIOR EQUIPMENT, COAX EXISTING GROUND WIRE TO MASTER CABLE BRIDGES AND COAXIAL CABLE GROUND KITS. ALL LUG TYPE MECHANICAL GROUND BAR SSC PLINTH TO MASTER GROUND BAR: 3. ELECTROSTATIC CONTROL -TO REDUCE ELECTROSTATIC DISCHARGE PROBLEMS. CONNECTORS TO THE MGB OR AGB SHALL BE TWO HOLE TYPE CONNECTED WITH #2 AWG STRANDED GREEN JACKETED GROUND WIRE STAINLESS STEEL BOLTS AND NUTS WITH STAINLESS STEEL LOCK WASHERS AND NOALOX 4. PERSONNEL SAFETY -TO MAINTAIN A MINIMUM VOLTAGE DIFFERENCE BETWEEN ANY ON EITHER SIDE OF THE BUSS BAR. TWO METALLIC OBJECTS WHICH PERSONNEL MIGHT CONTACT SIMULTANEOUSLY. FSEB TO MASTER GROUND BAR: 3.7 LIMITS OF BEND RADIUS: IT IS IMPORTANT THAT THE GROUNDING CONDUCTOR #6 AWG STRANDED GREEN JACKETED GROUND WIRE 2.2 A/C GROUNDING: IN THIS GROUNDING SYSTEM THE A/C SERVICE GROUND SHALL BE KEPT CONNECTING THE INSIDE AND OUTSIDE GROUND SYSTEMS BE AS STRAIGHT AS POSSIBLE, ISOLATED FROM THE EQUIPMENT FRAME WORK AND LIGHTNING PROTECTION GROUND WITH NO TURN OR BEND SHORTER THAN ONE FOOT RADIUS WITH A THREE FOOT RADIUS COVP TO MASTER GROUND BAR: SYSTEMS EXCEPT FOR ONE SPECIFIC POINT. THIS POINT IS THE MAIN GROUNDING POINT OF PREFERRED. NO RIGHT ANGLE OR SHARP BENDS SHALL BE ALLOWED. THE SYSTEM. THIS WOULD TYPICALLY BE CONNECTING THE A/C SERVICE GROUND AT THE #2 AWG STRANDED GREEN JACKETED GROUND WIRE COMMERCIAL POWER RISER POLE DISCONNECT/METER BASE TO THE EXTERNAL GROUND JEFFERY S. GUTOWSKY, 3.8 BONDING PREPARATION & FINISH: ALL SURFACES REQUIRE PREPARATION PRIOR TO RING. ALL GROUNDING CONNECTIONS INSIDE OF CABINETS SHALL BE SCRAPED TO BARE PROFESSIONAL ENGINEER METAL AND COATED WITH NOALOX. BONDING OF EITHER EXOTHERMIC WELD OR BURNDY FASTENERS. GALVANIZED SURFACES UNISTRUT COVP/FSEB FRAME TO MASTER GROUND BAR: STATE OF ILLINOIS SHALL BE GROUND OR SANDED TO THE POINT OF EXPOSING THE STEEL SURFACE BELOW, #2 AWG STRANDED GREEN JACKETED GROUND WIRE LICENSE # 062-047235 EXPIRES 11/30/17 SIGNED: 12/13/17 PRIOR TO BONDING THE GROUND CONDUCTOR. FOR OTHER SURFACES INCLUDING COPPER 2.3 LIGHTNING CONSIDERATIONS: LIGHTNING DAMAGE OCCURS FROM EITHER INDUCTION OR BUSS BARS ALL PAINT, RUST TARNISH AND GREASE SHALL BE REMOVED PRIOR TO FROM AN ACTUAL DIRECT STRIKE TO THE BUILDING, USUALLY TAKEN THROUGH THE BONDING THE GROUND CONDUCTOR. EXOTHERMIC WELD TYPE BONDS SHALL BE FINISHED DATE: DESCRIPTION: BY: REV: TOWER AND/OR ANTENNAS. STRIKES TO OTHER NEARBY OBJECTS INDUCE HIGH ENERGY WITH THE APPLICATION OF COLD GALVANIZATION AND WHEN APPLICABLE, FINISH PAINTED 09/14/16 FOR CLIENT REVIEW WCD A INTO POWER OR TELEPHONE CABLES ENTERING THE BUILDING. THIS TYPE OF EFFECT WITH AN APPROPRIATE COLOR AS REQUIRED. MECHANICAL TYPE BONDS ON BUSS BARS HISTORICALLY CAUSES MOST OF THE DAMAGE TO THE BUILDING AND ITS CONTENTS. SHALL BE FINISHED WITH THE APPLICATION OF NOALOX OR OTHER APPROVED CONDUCTIVE 11/08/16 FINALS RSM 0 3.0 STATION GROUNDING SYSTEM MEDIUM MATERIAL BETWEEN CONNECTOR AND BUSS BAR. MECHANICAL TYPE BONDS ON NOTE: ALL OTHER SURFACES SHALL BE FINISHED WITH THE APPLICATION OF COLD GALVANIZATION AND/OR THE APPROPRIATE PAINT TO MATCH AS REQUIRED. RESTORE EXISTING GROUNDS AS NEEDED FOR EXISTING 03/01/17 RFDS REVISION RSM 1 3.1 MATERIALS: 1. #2 AWG, BARE SOLID TINNED COPPER WIRE, FOR ALL EXTERIOR CONDUCTORS AND COAX LINES AND ANTENNAS USED FOR FINAL BUILD. TOWER GROUND BAR CONDUCTORS OR AS OTHERWISE SPECIFIED. GROUNDS TO THE 3.9 TESTING: THE OUTSIDE GROUND RING SHALL BE TESTED AFTER INSTALLATION BUT PRIOR 12/13/17 REVISION BLW 2 RF MODULES SHALL BE NO. 6 STANDARD GREEN INSULATED JUMPERS. THE GROUND TO BACKFILLING THE GROUND RING TRENCH. THE GROUND FIELD RESISTANCE SHALL WIRE TO THE MGB SHALL BE GREEN JACKETED STRANDED #2 TINNED WIRE BURNDY MEASURE 5 OHMS OR LESS TO GROUND. ANY DIFFICULTY IN ACHIEVING THIS LEVEL OF CONNECTED TO THE BUSS BAR AND CONNECTED TO THE GROUND RING ON A RESISTANCE MUST BE BROUGHT TO THE ATTENTION OF THE PROJECT MANAGER. THE GROUND ROD. RESISTANCE TO GROUND SHALL BE MEASURED USING THE FALL OF POTENTIAL METHOD. NOTE: TESTING SHALL BE PERFORMED BY AN OWNER PROVIDED INDEPENDENT TESTING CONTRACTOR TO INSTALL/REPLACE NEW 2. #2 AWG, INSULATED STRANDED COPPER CABLE IS ACCEPTABLE FOR INTERIOR LABORATORY FROM WHICH A WRITTEN REPORT SHALL BE PRODUCED FOR REVIEW BY THE OR MISSING GROUND BARS AS REQUIRED. GROUND BAR CONDUCTORS ON TENANT IMPROVEMENT SITES. PROJECT MANAGER. 3.10 GENERAL NOTES: 3. 5/8" X 10" GROUND RODS OF SOLID COPPER, STAINLESS STEEL OR COPPER CLAD HIGH 1. ALL ELECTRICAL WORK SHALL CONFORM TO THE NATIONAL ELECTRICAL CODE. STRENGTH STEEL. 2. GROUNDING SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE. 4. ABOVE GRADE CONNECTIONS SHALL BE BURNDY HYGROUND COMPRESSION. BELOW GRADE CONNECTIONS SHALL BE EXOTHERMIC WELD OR OTHER APPROVED 3. ALL ELECTRICAL ITEMS SHALL BE U.L. APPROVED OR LISTED. EXOTHERMIC WELDING SYSTEM FOR BONDING AS SPECIFIED. 4. CONTRACTOR TO OBTAIN ALL PERMITS, PAY PERMIT FEES, AND BE RESPONSIBLE FOR 5. XIT OR ADVANCED GROUNDING ELECTRODE (AGE), ALL CHEMICAL GROUND RODS SCHEDULING INSPECTIONS. SHALL BE UL APPROVED. LTE FSMF 5. PROVIDE ALL LABOR AND MATERIAL DESCRIBED ON THIS DRAWING, AND ALL ITEMS 6. SOLID COPPER PLATES OF MINIMUM 3'X3'X1/4" SIZE AS SPECIFIED. INCIDENTAL TO COMPLETING AND PRESENTING THIS PROJECT AS FULLY OPERATIONAL. UMTS FSME 7. NOALOX OR APPROVED EQUAL CONDUCTIVE MEDIUM MATERIAL SHALL BE USED IN 6. GROUNDING CONNECTIONS SHALL BE EXOTHERMIC TYPE ("EXOTHERMIC WELD") TO ALL MECHANICAL CONNECTIONS. ANTENNA MASTS, AND THE GROUND BARS. REMAINING GROUNDING CONNECTIONS GSM ESMC SHALL BE COMPRESSION FITTINGS. 8. #2 AWG STRANDED INSULATED (GREEN) FOR ALL INTERNAL EQUIPMENT GROUNDING. SM PLINTH 7. GROUND COAXIAL CABLE SHIELDS AT BOTH ENDS WITH COAX CABLE GROUNDING KITS & 9. MECHANICAL FASTENERS (I.E., DOUBLE LUGS, SPLIT BOLTS PARALLEL CONNECTORS) INSTALL WEATHER PROOFING KIT AT EACH CONNECTION. FSEB SHALL BE BRONZE, BRASS, COPPER OR STAINLESS STEEL AND HAVE NOALOX BETWEEN CONDUCTOR AND CONNECTION. 8. ALL EQUIPMENT FURNISHED BY OTHERS SHALL BE PROVIDED WITH PROPER MOTOR STARTERS, DISCONNECTS, CONTROLS, ETC. BY THE ELECTRICAL CONTRACTOR UNLESS 10. BOLTS, NUTS AND SCREWS USED TO FASTEN MECHANICAL CONNECTORS SHALL BE SPECIFICALLY NOTED OTHERWISE. THE ELECTRICAL CONTRACTOR SHALL INSTALL AND STAINLESS STEEL WITH STAR TYPE STAINLESS STEEL LOCK WASHERS. COVP COMPLETELY WIRE ALL ASSOCIATED EQUIPMENT IN ACCORDANCE WITH SITE INFORMATION: MANUFACTURER'S WIRE DIAGRAMS AND AS REQUIRED FOR A COMPLETE OPERATING 11. ALL LUG TUBE FASTENERS SHALL PROVIDE TWO HOLES TO ALLOW A DOUBLE BOLT CONNECTION. INSTALLATION. ELECTRICAL CONTRACTOR SHALL VERIFY AND COORDINATE ELECTRICAL CHARACTERISTICS AND REQUIREMENTS OF EQUIPMENT PRIOR TO ROUGH-IN OF SITE GOLDEN YEARS 3.2 MASTER GROUND BAR (MGB): THE PURPOSE OF THE MASTER GROUND BAR IS TO GROUND THE BTS AND ANY OTHER METALLIC OBJECTS AROUND THE BTS. IF AN MGB IS NOT 9. CONDUIT AND WIRING TO AVOID CONFLICTS WHERE APPLICABLE. GROUNDING CONDUCTORS SHALL BE COPPER OR SOLID TINNED COPPER. ALL SUPPORT CABINET PLAZA PROVIDED WITH THE BTS, THE MGB SHALL BE AS FOLLOWS: THE MGB IS A COPPER BAR CONNECTIONS MADE BELOW GRADE SHALL BE SOLID TINNED COPPER. ALL MEASURING 4"W X 24"L X 1/4" LOCATED AS CLOSE TO THE BTS AS POSSIBLE. THE MGB SHALL HAVE A MINIMUM NUMBER OF (28) 3/8" HOLES. GROUND BAR SHALL BE SUPPORTED CONNECTIONS ABOVE GRADE STRANDED IS PERMITTED. CH17481C BY MOUNTING BRACKETS WITH INSULATOR STANDOFFS. (2) #2 TINNED SHALL BE 10. ALL EXOTHERMIC WELDS ABOVE FINISHED GRADE SHALL BE PAINTED WITH MGB MECHANICALLY ATTACHED (2-HOLE COMPRESSION LUG 3/8" HOLES, 1" CENTER TO CENTER CO-GALVANIZED ZINC ENRICHED PAINT TO MATCH COLOR OBJECT BONDED TO. SPACING) TO THE MGB AND DOWN LEADS THEN TAKEN THROUGH CONDUIT TO THE GROUND 507 E. TAYLOR ST. RING. THIS CONDUCTOR SHALL BE KEPT SEPARATE AND ISOLATED UNTIL TERMINATING AT 11 CONNECT COAX GROUND KITS TO MASTER GROUND BAR AT BASE OF TOWER. DEKALB, IL 60115 THE MAIN GROUNDING POINT, (I.E. EXTERIOR GROUND RING OR BUILDING STEEL). W-T JOB NUMBER: T1601208 12. CONNECT COAX GROUND KITS TO GROUND BUS AT TOP OF TOWER. SSC PLINTH 3.3 ANTENNA GROUND BAR (AGB): THE PURPOSE OF THE ANTENNA GROUND BAR IS PRIMARILY SHEET TITLE: FOR LIGHTNING PROTECTION. COAXIAL CABLE IS USUALLY THE ONLY ITEM GROUNDED TO 13. CONNECT RF MODULE GROUND TO GROUND BUS AT TOP OF TOWER. ROOFTOP THIS BAR. HOWEVER IT IS ACCEPTABLE TO BOND EXTERIOR; CABLE TRAY, WAVE GUIDE PORTS AND CANTILEVERED WAVE GUIDE BRIDGES TO THE AGB. THE AGB IS A COPPER BAR 14. PLAN DRAWINGS SHOWN HEREIN DO NOT NECESSARILY DEPICT ELECTRICAL MEASURING 4"W X 24"L X 1/4". THERE SHALL BE TWO AGBS, ONE LOCATED AT THE TOP OF REQUIREMENTS OF INDIVIDUAL EQUIPMENT AND DEVICES SUCH AS THE EQUIPMENT THE TOWER AT THE START OF THE VERTICAL RUN OF COAX, THE OTHER AT THE BOTTOM OF GROUNDING REQUIREMENTS, POWER REQUIREMENTS AND TELCO RACEWAY THE VERTICAL RUN OF COAX BEFORE IT MAKES ITS BEND. (IF THE TOWER IS OVER 200' REQUIREMENTS. THERE SHALL BE A THIRD AGB LOCATED AT HE MIDDLE OF THE TOWER).THE AGB SHALL HAVE A MINIMUM OF (28) 3/8" HOLES. GROUND BARS SHALL BE SUPPORTED BY MOUNTING 15. PLAN DRAWINGS SHOWN HEREIN ARE DIAGRAMMATIC AND DO NOT NECESSARILY BRACKETS WITH INSULATOR STANDOFFS. USE #2 AWG SOLID TINNED WIRE W/ 2-HOLE DEPICT THE EXACT EQUIPMENT QUANTITIES, LOCATION, LAYOUT AND CONFIGURATION. SHORT BARREL COMPRESSION LUGS 3/8" HOLES, 1" CENTER TO CENTER SPACING). THIS REFER TO ARCHITECTURAL PLANS FOR EXACT EQUIPMENT LOCATION, LAYOUT AND CONDUCTOR SHALL BE KEPT SEPARATE AND ISOLATED UNTIL TERMINATING AT THE MAIN CONFIGURATION. SHEET NUMBER: GROUNDING POINT (I.E. EXTERIOR GROUND RING, OR BUILDING STEEL.) 16. NUMBER OF ANTENNAS REPRESENTED IN THIS DETAIL ARE FOR SHOWING CLARITY OF GROUND SYSTEM REQUIREMENTS ONLY. SEE RF INFO FOR ANTENNA QUANTITY. 17. CONTRACTOR TO 'NOALOX' ALL CONNECTIONS TO GROUND BARS. PLOT SCALE: 1:1 @ 11"x17" NOTES: -EXTERIOR GROUND BARS TO BE TIN PLATED KEY NOTES: -HARDWARE SHALL BE STAINLESS STEEL STAINLESS STEEL -CONTRACTOR SHALL GROUP INCOMING WIRES HARDWARE 1/4" THK ELECTRICAL TINNED GROUND BAR HARGER -CONTRACTOR TO APPLY 'KOPR-SHIELD' TO ALL 8550 BRYN MAWR AVENUE, SUITE 100 1. OR APPROVED EQUAL. HOLE CENTERS TO MATCH CHICAGO, ILLINOIS 60631 CONNECTIONS STAINLESS STEEL 3/4"x3/8" O.D. NEMA DOUBLE LUG CONFIGURATION FLAT WASHER (TYP) INSULATORS (UNLESS NOTED OTHERWISE) PLANS PREPARED BY: 2. STAINLESS STEEL LOCKWASHER (TYP) 3. 3/8" STAINLESS STEEL LOCKWASHERS NOTE: WALL MOUNTING BRACKET CONTRACTOR TO INSTALL/REPLACE NEW 4. OR MISSING GROUND BARS AS REQUIRED. STAINLESS STEEL 5. 3/8" STAINLESS STEEL BNLF BOLTS STAINLESS STEEL FLAT WASHER (TYP) CONTRACTOR SHALL USE PERMANENT MARKER TO DRAW THE NUTS (TYP) LINES BETWEEN EACH SECTION AND LABEL EACH SECTION 6. ("P", "A", "N", "I") WITH 1" HIGH LETTERS 2675 Pratum Avenue Hoffman Estates, Illinois 60192 3/8" X 1-1/4" PH: (224) 293-6333 FAX: (224) 293-6444 www.wtengineering.com STAINLESS IL. License No.: 184.007570-0015 Exp: 04/30/19 STEEL HEX BOLT C EXPOSED BARE COPPER TO BE SEAL: TWO HOLE COPPER KEPT TO ABSOLUTE MINIMUM, NO COMPRESSION INSULATION ALLOWED WITHIN THE GROUNDING TERMINAL COMPRESSION TERMINAL (TYP) CABLE GROUND BAR GROUNDING CABLE A ELEVATION A SECTION "A-A" 1 JEFFERY S. GUTOWSKY, 1. OXIDE INHIBITING COMPOUND TO BE USED AT ALL LOCATIONS 5 PROFESSIONAL ENGINEER 2. NO CRIMPING OF SOLID #2. USE EXOTHERMIC WELD ONLY 4 USE THEFT PROOF STATE OF ILLINOIS LICENSE # 062-047235 FASTENERS ON ALL EXPIRES 11/30/17 SIGNED: 12/13/17 GROUND BARS COMMSCOPE PART# DATE: DESCRIPTION: BY: REV: MTC9674KEY 09/14/16 FOR CLIENT REVIEW WCD A 6 6 11/08/16 FINALS RSM 0 I N 03/01/17 RFDS REVISION RSM 1 A 12/13/17 REVISION BLW 2 P NOTE: 3 THE FOLLOWING SYMBOLS SHOWN ARE HARGER ULTRAWELD EXOTHERMIC CONNECTIONS WITH PART 2 #2 AWG STRANDED NUMBERS BELOW. THESE CONNECTIONS MAY BE GREEN JACKETED TO CROSS-REFERENCED WITH CADWELD CONNECTIONS GROUND SOURCE WHICH ARE SHOWN IN PARENTHESIS. TO GROUND EACH GROUND CONDUCTOR TERMINATING ON ANY GROUND BAR SHALL HAVE AN IDENTIFICATION TAG ATTACHED AT EACH END THAT WILL IDENTIFY ITS ORIGIN AND DESTINATION SECTION "P" - SURGE PRODUCERS COLLECTOR GROUND BAR GENERATOR FRAMEWORK (IF AVAILABLE) TELCO GROUND BAR GT GO HB HD BS XX COMMERCIAL POWER COMMON NEUTRAL/GROUND BOND (GR) FIBER GROUND BAR SITE INFORMATION: (GT) (HS) (HA) (SS) (XA) EQUIPMENT ROOM COLLECTOR GROUND BAR HVAC GOLDEN YEARS RECTIFIER FRAMES PLAZA SECTION "A" - SURGE ABSORBERS INTERIOR GROUND RING CH17481C EXTERNAL EARTH GROUND FIELD (BURIED GROUND RING) METALLIC COLD WATER PIPE (IF AVAILABLE) 507 E. TAYLOR ST. BUILDING STEEL (IF AVAILABLE) AC POWER DEKALB, IL 60115 W-T JOB NUMBER: T1601208 SHEET TITLE: VA LE VA BD, BE, BU PT RT SECTION "N" - NON-ISOLATED GROUND ZONE EQUIPMENT (PT) MISCELLANEOUS NON-ISOLATED GROUND ZONE EQUIPMENT (VH) (GL) (VS) (LJ) (TA) CABLE TRAY SYSTEM EQUIPMENT FRAMES BATTERY RACKS DC POWER SECTION "I" - ISOLATED GROUND ZONE ISOLATED EQUIPMENT FRAMES SHEET NUMBER: ISOLATED GROUND BAR - IGB PLOT SCALE: 1:1 @ 11"x17"