Appearance Commission
Regular MeetingSkokie, IL · April 10, 2024
Minutes
Appearance Commission Meeting Minutes
Date: April 10, 2024
Appearance Members Present:
Chairman Lynk
Maryjane Klein
Joe Maschek
Jay Pathak
Thomas DaMario
Julie Naumiak
Archana Shah
Appearance Members Absent:
Staff Present: Brian Augustine, Zoning Administrator
Nasko Pelinkaj, Building & Zoning Coordinator
(I) CALL TO ORDER
A quorum being present, Chairman Lynk called the meeting to order.
(II) APPROVAL OF MINUTES
A motion was made by Commissioner Mascheck to approve the minutes of the
previous meeting. The motion was seconded by Commissioner Klein. All
members voted aye
(III) CASE DESCRIPTIONS
Case 2024-009A – 8447 Gross Point Rd
Applicant: & Owner: Syed Qasim
Request: 1st Floor Addition
Discussion and Interested Parties
The architect stated a 10x7 sunroom has been built.
Staff showed renderings that depict home prior to rehab and showed new addition.
Chair asked if that is the extent of the entire project.
Staff said the façade and color change as well.
1
Commissioner Maschek asked about materials to be used.
The architect said hardy board.
Commissioner DaMario asked if addition is visible from the street.
The architect said it is set back.
Recommendation and Voting
A motion was made to grant a Certificate of Appropriateness to approve as
Presented. The vote was unanimous.
Motion: Naumiak Second: Pathak Absent: None
Ayes: 7
Nays: 0
Case 2024-011A – 4999 Old Orchard Center A26
Applicant Laszlo Simovic
Owner: Alexios Georges
Request: Non-Residential- Façade and Signage
Discussion and Interested Parties
Commissioner DaMario read Staff comments into the record.
Chairman Lynk asked if the proposed was a separate tenant and whether it was different
from Maggiano’s.
The petitioner replied, yes.
Commissioner Maschek asked if the changes include those requested by Old Orchard
review.
The petitioner replied, yes.
Chairman Lynk said that it looked great but questioned whether patrons would mistake
the space as being part of Maggiano’s.
The petitioner added that the concept currently exists in Evanston on Grove St.
Commissioner DaMario asked for the material of the façade.
The petitioner replied, black tile.
Recommendation and Voting
A motion was made to grant a Certificate of Appropriateness.
The vote is unanimous.
2
Motion: Maschek Second: Naumiak Absent: None
Ayes: 7
Nays: 0
Case 2024-010A – 9023 Niles Center Rd
Applicant & Owner: Saleem Ghaffar
Request: Residential- 2nd Floor Addition
Discussion and Interested Parties
Commissioner DaMario read Staff comments into the record.
Chairman Lynk asked the petitioner if he was the homeowner.
He replied that he is the son of the homeowner.
The petitioner added that they are planning an addition to accommodate a growing
family.
Chairman Lynk asked if it will be all new brick.
The petitioner replied that the 1st floor brick would stay and try to match existing.
Commissioner Maschek mentioned that there are two different kinds of brick.
Chairman Lynk said that the brick cannot be matched. He added that there should be a
way to separate the two brick colors.
Commissioner Maschek said that stained brick has been approved in the past with
common bricks on the side. He asked if the 2nd floor would be bricked or siding. The
notes and rendering contradict material usage.
The petitioner said that he would need to verify the proposed material for the 2nd floor.
Chairman Lynk said that the canopy at the front is too small.
Staff added that if a canopy comes into the required front yard by 3’, a Zoning Board of
Appeals case would be required.
Chairman Lynk said that the canopy should be about 25% wider.
Commissioner DaMario said the petitioner must consider whether to match the existing
brick or use siding.
Chairman Lynk goes to the screen to verify where the new brick meets the existing on
the rendering.
Commissioner Machek said he preferred hardy board or different cementitious material.
Commissioner Macheck said that horizonal siding on the front elevation may look better
than brick.
Commissioner Shah suggested a band of stone to separate the new and the old.
Commissioner Maschek brought up brick spraying as another potential solution.
3
Chairman Lynk stated that brick is ok on the front elevation if it matches and added that
it could be stained to match. He added that siding is ok on the side elevations but it
should be taken down to the existing brick and that it must be hardy board, not siding.
Commissioner Maschek said that there should be a return added to the sides.
Commissioner Naumiak does not like the notch on the side.
Commissioner DaMario asked the petitioner if he would like to go with the
recommendations or come back with a new plan in a month.
The petitioner would like to consider the recommendations.
Recommendation and Voting
A motion was made to grant a Certificate of Appropriateness with the following
provisions: the canopy at the front door be widened at least a foot on either side of
center; the front elevation be constructed of face brick to match existing brick or stain
existing and new brick to match; the side elevations permit the use of a cementitious
siding, not vinyl siding; and that the siding match come down to meet the existing brick
with no additional brick on side elevations; and a 12’’ return to be incorporated on the
front elevation with face brick to the sides.
Motion: DaMario Second: Naumiak Absent:
Ayes: 7
Nays: 0
(V) ADJOURNMENT
Chairman Lynk adjourned the meeting a 7:59PM.
4
Agenda
Meeting Agenda
Skokie Appearance Commission
Wednesday, April 10, 2024 at 7:30 P.M.
Village of Skokie
5127 Oakton Street
Skokie, IL 60077
I. Call to Order
II. Roll Call
III. Approval of Minutes from March 27, 2024 Meeting
IV. New Business
a. Consideration of a Certificate of Appropriateness for Residential Properties:
2024-009A – 8447 Gross Point Rd.
Applicant & Owner: Syed Qasim
Request: 1st Floor Addition
2024-010A – 9023 Niles Center Rd.
Applicant & Owner: Saleem Ghaffar
Request: 2nd Floor Addition
b. Consideration of a Certificate of Appropriateness for Non-Residential Properties:
2024-011A – 4999 Old Orchard Center A26.
Applicant: Laszlo Simovic
Owner: Alexios Georges
Request: Non-Residential – Façade & Signage
V. Old Business
VI. Public Comment (for non-agenda items)
VII. Adjourn
618508- Appearance Commission Agenda for April 10, 2024
Appearance Commission Meeting Minutes
Date: March 27, 2024
Appearance Members Present:
Chairman Lynk
Maryjane Klein
Joe Maschek
Jay Pathak
Thomas DaMario
Appearance Members Absent: Julie Naumiak
Staff Present: Brian Augustine, Zoning Administrator
Nasko Pelinkaj, Building & Zoning Coordinator
(I) CALL TO ORDER
A quorum being present, Chairman Lynk called the meeting to order.
(II) APPROVAL OF MINUTES
A motion was made by Commissioner DaMario to approve the minutes of the
February 28, 2024 meeting. The motion was seconded by Commissioner Pathak.
All members voted aye
(III) CASE DESCRIPTION
Case 2024-005A – 4300 Keeney Ave
Applicant: & Owner: Mark & Margaret Lindsay
Request: 1st Floor Attached Garage Addition
Discussion and Interested Parties
DaMario read Staff comments into the record.
Chariman Lynk asked if colors would match would existing.
The Petitioner responded, yes.
Commissioner Maschek admired the midcentury design.
Recommendation and Voting
1
A motion was made to grant a Certificate of Appropriateness to approve as
Presented. The vote was unanimous.
Motion: Maschek Second: Pathak Absent: Naumiak
Ayes: 6
Nays: 0
Case 2024-006A – 9543 Lincolnwood Dr
Applicant & Owner: Ryan Lezcano
Request: 1st and 2nd Floor Addition
Discussion and Interested Parties
DaMario read Staff comments into the record.
Staff asked for verification on where addition will be placed.
The architect points out the area near the grill on renderings.
Chairman Lynk also asked for clarification on proposed addition location.
Commissioner Maschek asked if the gable will peak out.
The architect added that that the gable will align with the front and will not be visible from
street.
Chairman Lynk asked what the material used will be.
The architect responded that it will be hardy board or a different type of siding and will
match existing in color.
Chairman Lynk asked if a calculation on the siding/brick proportions would be required.
Staff replied, no.
Commissioner Maschek asked if the existing sunroom would be sided with the same
cementitious material.
The architect said this will be discussed with the homeowner.
Commissioner Maschek advised to replace the siding because it is melted.
Recommendation and Voting
A motion was made to grant a Certificate of Appropriateness.
The vote is unanimous.
Motion: Pathak Second: Shah Absent: Naumiak
Ayes: 6
Nays: 0
2
Case 2024-007A – 9340 Avers Ave
Applicant & Owner: Michael Arfa
Request: Residential- 1st and 2nd Floor Addition
Discussion and Interested Parties
Chairman Lynk asked if new materials will blend and if residing.
The Petitioner responded, yes.
Commissioner Maschek asked for clarification about whether or not the shutters would
remain while siding is replaced. He said a wider shutter would look nice.
Chairman Lynk reminded the Petitioner to take note of comment regarding fire sprinkler
requirements.
Recommendation and Voting
A motion was made to grant a Certificate of Appropriateness to approve as
Presented. The vote is unanimous.
Motion: Shah Second: Pathak Absent: Naumiak
Ayes: 6
Nays: 0
Case 2024-008A – 8452 Harding Ave
Applicant: Walsh Custom Homes
Owner: Mark & Terri Bernstein
Request: Residential 2nd Floor Addition
Discussion and Interested Parties
Commissioner DaMario read Staff comments into the record.
Staff stated that a slight revision was made and hard copy renderings were brought to
the meeting.
Chairman Lynk asked if the cantilever is on the back.
Chairman DaMario asked if will be less than 2’ in length.
The cantilever component is briefly discussed.
Chairman Lynk asked Commissioner DaMario if he was ok with the cantilever.
Both were ok with the cantilever component.
Recommendation and Voting
3
A motion was made to grant a Certificate of Appropriateness to approve as
Presented. The vote is unanimous.
Motion: Klein Second: Pathak Absent: Naumiak
Ayes: 6
Nays: 0
Case 2023-043A – 5425 Touhy Ave
Applicant: MJM Architects/Amanda Clark
Request: Non Residential- Façade & Signage
Discussion and Interested Parties
Commissioner DaMario read Staff comments into the record.
Chairman Lynk asked whether the changes were part of a nationwide rebranding.
Commissioner Maschek said he liked the proposed design better than the current.
Chairman Lynk asked for photos of the rest of the mall. He added that the original design
of the mall has changed over time, and that he would be ok with the changes if there is
precedent for such design.
Commissioner DaMario said the lettering on the blue looked smaller than the current.
The architect said the lettering will be smaller.
Recommendation and Voting
A motion was made to grant a Certificate of Appropriateness to approve as
Presented. The vote is unanimous.
Motion: DaMario Second: Pathak Absent: Naumiak
Ayes: 6
Nays: 0
(V) ADJOURNMENT
Chairman Lynk adjourned the meeting a 7:49PM.
4
MEMORANDUM
Community Development Department
To: Michael Lynk, Appearance Commission Chair
Appearance Commission Members
From: Brian J Augustine, Zoning Administrator/Permit Supervisor
Nasko Pelinkaj, Building & Zoning Division Coordinator
Jose Acosta, Planning Coordinator
Justin Malone, Neighborhood Services Coordinator
Date: April 10, 2024
SUBJECT: APPEARANCE COMMISSION STAFF REPORT
Staff offers the following comments on the cases scheduled for the April 10, 2024, Appearance
Commission meeting:
NEW BUSINESS:
RESIDENTIAL REQUESTS
2024-009A 8447 Gross Point Rd – Staff has no objections to the proposed addition and façade
changes that have already taken place. The proposed addition will need to meet all
building code requirements and it need be, will be required to be re-built. The color
changes to the siding updated a building that needed some refreshing.
2024-010A 9023 Niles Center Rd – Staff has no objections to the proposed second story
addition. The addition is similar in terms of size to an addition at 9031 Niles Center
Rd. Staff will verify if all zoning requirements are met, during permit review. If the
existing 1st floor brick is not changing, staff would like to see the 2nd floor brick
match the existing. If the existing brick is changing, all of the brick should be of a
uniform color.
NON-RESIDENTIAL REQUESTS
2024-011A 4999 Old Orchard Center A26 – In August, 2022, Maggiano’s received a certificate
of appropriateness for their proposed façade and signage changes. The changes
included the former Corner Bakery. The approved elevations are in the packet.
Staff has no objections to the proposed signage and façade changes. The proposed
wall color compliments the approved colors of the Maggiano’s portion of the façade.
The signage looks similar to Maggiano’s, but has its own font to stand out on its own.
Staff appreciates the landscape planters and lighting on the east elevation to help
soften up the façade.
Doc 618214 March 27, 2024 Appearance Staff Report
1
8447 GROSS POINT RD, SKOKIE IL
LOCATION MAP PROJECT SCOPE
MINOR INTERIOR RENOVATION TO EXISTING SINGLE FAMILY RESIDENCE
WORK AREA SCHEDULE PROJECT CERTIFICATION
FLOOR AREA
FIRST FLOOR 1183 SQFT
I HEREBY CERTIFY THAT THESE DRAWINGS WERE PREPARED UNDER MY PERSONAL
BASEMENT 1101 SQFT SUPERVISION AND TO THE BEST OF MY KNOWLEDGE COMPLY WITH THE LOCAL CODES OF
SKOKIE ILLINOIS.
TOTAL 2284.00 SQFT ARCHITECT IS NOT RESPONSIBLE FOR MEANS AND METHODS OF CONSTRUCTION.
INDEX OF DRAWINGS
GENERAL :
T100 COVER SHEET ILLINOIS LICENSE NUMBER: 001.020008
LIC. EXP.: APR. 2025
ARCHITECTURAL : PRASHANTH MAHAKALI P.C.
ILLINOIS DESIGN FIRM REG. NUMBER: 184.005230
A100 DEMOLITION PLANS
A300 PROPOSED PLANS
P
A400 PROPOSED ELEVATIONS
ENERGY CERTIFICATION
ELECTRICAL :
(50 OIN
E100 ELECTRICAL PLANS AND NOTES
PLUMBING :
I CERTIFY THAT I AM A REGISTERED ENERGY PROFESSIONAL (REP). I ALSO CERTIFY THAT TO
P100 PLUMBING DIAGRAMS AND NOTES THE BEST OF MY PROFESSIONAL KNOWLEDGE AND BELIEF THAT THE ATTACHED PLANS FOR
8447 GROSS POINT SKOKIE IL
VILLAGE OF OAK PARK, IL / ADOPTED NEED TO COMPLY WITH THE REQUIREMENTS OF THE MUNICIPAL CODE OF SKOKIE
.00 T
BUILDING CODES
2021 INTERNATIONAL RESIDENTIAL CODE SIGNED:
(ARCH.,)
DATE:2-8-24
2014 STATE OF ILLINOIS PLUMBING CODE
2020 NATIONAL ELECTRIC CODE
') RD
2021 INTERNATIONAL MECHANICAL CODE
2018 INTERNATIONAL ENERGY CONSERVATION CODE
2021 INTERNATIONAL FIRE CODE
OS . (12
S 5.0
GR 0')
REVISIONS
(12 NO. DATE
1 3-25-24
DESCRIPTION
REVISIONS
5.0 8'- 1
5
2"
0')
3'- 1
4 DRAWN BY: ----- -----@pmpcarch.com
4" CHECKED BY: JON jon@pmpcarch.com
') DATE ISSUED:
.00
0" PROJECT ADDRESS:
2'-
3'- 1 8447 GROSS POINT
9
4" SKOKIE IL
7'- 1
6
(50
2"
PERMIT #:
N
SITE PLAN
SCALE: 1/8" = 1'-0" COVER SHEET
COPYRIGHT 2025 PRASHANTH MAHAKALI P.C.
T100
DEMOLITION NOTES
1. COMPLY WITH APPLICABLE LOCAL, STATE AND FEDERAL
CODES AND REGULATIONS PERTAINING TO SAFETY OF
PERSONS, PROPERTY AND ENVIRONMENTAL PROTECTION
2.PROVIDE AND MAINTAIN BARRICADES, LIGHTING, AND
GUARDRAILS AS REQUIRED BY APPLICABLE CODES AND
REGULATIONS TO PROTECT OCCUPANTS OF BUILDING AND
WORKERS.
3.ERECT AND MAINTAIN DUSTPROOF PARTITIONS AS REQUIRED
TO PREVENT SPREAD OF DUST, AND SMOKE, ETC. TO OTHER
PARTS OF THE BUILDING. ON COMPLETION, REMOVE
18'-2" 5'-0" 11'-6"
PARTITIONS AND REPAIR DAMAGED SURFACES TO MATCH 18'-0"
ADJACENT SURFACES.
4.IF DEMOLITION IS PERFORMED IN EXCESS OF THAT REQUIRED,
RESTORE AFFECTED AREAS AT NO COST TO THE OWNER. FP
5.REMOVE EXISTING FLOOR FINISHES AS INDICATED PER PLANS.
6.REMOVE EXISTING DRYWALL AS INDICATED PER PLANS DN
7.REMOVE EXISTING PARTITION WALLS. PROVIDE ANY BATH RM
NECESSARY SHORING & BRACING DURING DEMO WORK.
8.REMOVE EXISTING DOORS, FRAMES, AND HARDWARE.
9.REMOVE EXISTING LIGHT FIXTURES AND CEILING FINISHES BEDROOM
DOWN TO GYPSUM BOARD AND/OR PLASTER AND LATH
CEILING. AS INDICATED PER PLANS REMOVE AND REPLACE
EXISTING FLOORING
12'-1"
10.REMOVE ALL BUILT-IN/FREE STANDING
EXISTING ROOF OVER
DISPLAYUNITS/EQUIPMENT CABINETS, COUNTER TOPS,
16'-0" 14'-4"
CARPORT TO REMAIN
SHELVING/ ETC. STORE FOR RE-INSTALLATION. COORDINATE
WITH OWNER AS INDICATED PER PLANS. LIVING RM
10'-103 4"
11. REMOVE EXISTING PLUMBING FIXTURES AND CAP OFF REMOVE AND REPLACE
EXISTING WASTE, WATER PIPING ETC. STORE FOR RE- KITCHEN EXISTING FLOORING
INSTALLATION AS INDICATED PER PLANS
DW REF
CUTTING, PATCHING 10'-9"
& REFINISHING 7'-0"
SUNROOM
1. WHERE REQUIRED TO CUT INTO EXISTING CONSTRUCTION, REMOVE AND REPLACE
RESTORE SURFACES TO THEIR ORIGINAL CONDITION OR TO EXISTING FLOORING
THE ADJOINING NEW SURFACE. USE MATERIALS THAT ARE
9'-1112"
IDENTICAL TO EXISTING MATERIALS UNLESS OTHERWISE
NOTED. IF IDENTICAL MATERIALS ARE NOT AVAILABLE, BEDROOM
MATCH WITH REGARD TO VISUAL EFFECT. RESTORE IN A BEDROOM
MANNER WHICH WILL ELIMINATE EVIDENCE OF PATCHING
10'-6"
AND REFINISHING.
2.DO NOT CUT AND PATCH STRUCTURAL WORK, OR
OPERATIONAL- OR SAFETY-RELATED COMPONENTS, THAT
WOULD RESULT IN A REDUCTION OF LOAD-CARRYING
CAPACITY, LOAD-DEFLECTION RATIO, OR CAPACITY TO
PERFORM.
3. TEMPORARILY SEAL DUCT REGISTER BOXES, SUPPLY PLENUMS, FIRST FLOOR PLAN: DEMOLITION 10'-3" 13'-2"
RANGE HOOD, BATH EXHAUST FANS, AND LINER BOXES SCALE : 1/4" = 1'-0"
DIRECTLY FOLLOWING MECHANICAL ROUGH-IN TO PREVENT O 2' 4' 8'
ENTRY OF CONSTRUCTION DUST AND POLLUTANTS INTO
DUCT SYSTEM. REMOVE AND REPLACE
4.LEAD BASED PAINT TESTING: THIS HOME WAS CONSTRUCTED EXISTING WALLS AND ROOF
IN 1967, AND IS REQUIRED BY FEDERAL LAW TO BE TESTED FOR OVER BASEMENT ENTRY
LEAD BASED PAINT.
A.TEST ALL INTERIOR AND EXTERIOR PAINTED SURFACES FOR
THEPRESENCE OF LEAD. THIS TESTING SHALL BE PERFORMED
PRIOR TO ANY REPAIR WORK. TEST RESULTS SHALL BE
FURNISHED TO THE OWNER WITHIN 10 CALENDAR DAYS OF
THE NOTICE TO PROCEED.
4'-6" 10'-9"
B. CERTIFIED TESTER: THE TESTING SHALL BE ACCOMPLISHED
AND A REPORT FURNISHED BY A CERTIFIED AND LICENSED
INDIVIDUAL. ALL PROCEDURES AND TESTING METHODS
SHALL COMPLY WITH FEDERAL, STATE, AND LOCAL LAWS
AND REGULATIONS.
C.LEAD BASED PAINT ABATEMENT, REMOVAL, OR UP
ENCAPSULATION: IF ANY SURFACES TEST POSITIVE FOR THE
PRESENCE OF LEAD BASED PAINT, THE CONTRACTOR SHALL
RECOMMEND THE MOST COST EFFECTIVE METHOD OF
ABATING, REMOVING, OR ENCAPSULATING THE HAZARD BATH RM
AND A BID FOR THE ACCOMPLISHMENT OF THE REQUIRED 18'-5" REMOVE AND REPLACE
WORK. EXISTING FLOORING
12'-0"
D.COMPLIANCE RECORDS: SHARE A COPY OF THE STORAGE
COMPLIANCE RECORDS REQUIRED FOR REMODELERS UNDER
13'-6"
WASHER DRYER
THE REGULATION (SUCH AS THE CHECKLIST OF FOLLOWED
PRACTICES) WITH HOME OWNERS WITHIN 30 DAYS OF LDRY RM
COMPLETION OF THE WORK.
9'-7" F-1
5. ASBESTOS ABATEMENT: IF ASBESTOS-CONTAINING MATERIAL
IS DISTURBED, THEN MOVE, REMOVE, ENCAPSULATE OR EXISTING
REMOVE AND REPLACE REVISIONS
EXISTING FLOORING
DISPOSE OF ACCORDING TO ALL LOCAL, STATE AND FEDERAL FURNACE
NO. DATE DESCRIPTION
LAWS AND REGULATIONS. TO REMAIN
HWH MECH. RM. 1 3-25-24 REVISIONS
ELEC. PANEL
UTILITIES
1.EXISTING UNDERGROUND UTILITIES SHOULD BE
LOCATED BY THE CONTRACTOR PRIOR TO BEGINNING 6'-4" 8'-10"
DEMOLITION OR CONSTRUCTION. 18'-314" REMOVE AND REPLACE
EXISTING DAMAGED DRYWALL DRAWN BY: ----- -----@pmpcarch.com
7'-5" 6" CONC. SLAB JON jon@pmpcarch.com
CHECKED BY:
SITE WORK FAMILY RM 11'-9"
DATE ISSUED:
PROJECT ADDRESS:
1.GENERAL CONTRACTOR SHOULD FIELD VERIFY ALL
DIMENSIONS AND GRADING CONDITIONS AND SHOULD
INFORM ARCHITECT OF FIELD CONDITIONS WHICH REQUIRE
MODIFICATIONS TO THE DRAWINGS. 10'-11" 23'-0"
G OSS POINT
S O IE IL
PHASE LEGEND
PERMIT #:
INDICATES EXISTING CONDITION TO REMAIN UP
BASEMENT PLAN: DEMOLITION FD
SCALE : 1/4" = 1'-0"
O 2' 4' 8'
INDICATES EXISTING CONDITION TO BE REMOVED
REMOVE AND REPLACE EXISTING/ DEMO PLANS
EXISTING WALLS AND ROOF
OVER BASEMENT ENTRY
GRAPHIC SCALE
0' 2'
COPYRIGHT 2025 PRASHANTH MAHAKALI P.C.
4' 8' A100
SECOND FLOOR PLAN: EXISTING
1 WINDOW SCHEDULE CEILING
NEW 24" X 24" X 12" NEW PLUMBING
TYPE NO. WIDTH HEIGHT SILL HEIGHT LIGHT VENT QTY. CONC. FOOTING UNDER FIXTURES, TILE WALLS
NEW POST AND FLOORING
FIRST FLOOR
DOUBLE HUNG 1 2'-6" 4'-0" 2'-0" 10.00 5.00 1 18'-2" 5'-0" 11'-6"
2'-6" 7'-9" 7'-9"
CASEMENT 2 2'-6" 3'-6" 2'-0" 8.75 4.38 12
NOTES :
- CONFIRM ALL DOOR AND WINDOW SELECTIONS WITH OWNER PRIOR TO ORDER FP
- VERIFY ALL WINDOW AND DOOR SIZES ON SITE BEFORE ORDERING
- ALL REPLACEMENT WINDOWS TO HAVE MIN 'U' RATING OF .034 AND CONFORM TO ENERGY CONSERVATION DN
CODE OF CITY OF CHICAGO
NEW 6 X 6 POST
PRESSURE TREATED
BATH RM
18'-0"
1. ALL WINDOWS USED FOR LIGHT AND VENT CALCULATIONS IN THIS SCHEDULE ARE SET IN WALLS WHICH VENT
ARE A MINIMUM OF 3'-0" FROM THE LOTLINE. (UNLESS PRE-EXISTING)
2. DOORS REQUIRED AS EXITS ARE SIZED AS SHOWN ON THE FLOOR PLAN AS PER 10(13.160.220) ARE SOLID FLOOR
EXISTING 2 X 10
CORE DOORS IN 1 HR. WALLS. EXIST DOORS ARE KEYLESS.
BEDROOM
12'-1"
RAFTERS @ 16" 0.C.
NEW FLOORING
COMBUSTION AIR OPENING DETAIL
16'-0" 14'-4"
EXISTING ROOF OVER NEW APPLIANCES,
CABINETS, AND FLOORING SMOKE / CO
CARPORT TO REMAIN LIVING RM DETECTOR
TO REMAIN
SMOKE / CO
WALL LEGEND TYP. 1 HR ASSEMBLY NOTE:
DETECTOR
EACH OPENING SHALL HAVE A MINIMUM KITCHEN NEW FLOORING SMOKE / CO
NEW SIDING OVER BUILDING PAPER 34"
OVEREXT. PLYWOOD NEW FASCIA AND GUTTERS DETECTOR
3 FREE AREA OF NOT LESS THAN ²1 IN
/1000 SMOKE / CO
OVER 2 X 4 WD STUDS @ 16" OVER
4" EXT. PLYWOOD OVER VINYL BTU/HR OF THE TOTAL INPUT RATING OF DETECTOR
SIDING TOP PLATE ALL FUEL BURNING EQUIPMENT IN THE
CONFINED SPACE, BUT NOT LESS THAN 100 EXISTING (3) 2 X 12 TO REMAIN
NEW SIDING OVER BUILDING PAPER 34"
OVER
EX.T PLYWOOD
IN². THE MINIMUM DIMENSION OF AIR
OVER 2 X 4 WD STUDS @ 16" O.C AND R-19 INSULATION IN
OPENINGS SHALL BE NOT LESS THAN 3 IN NEW 6 X 6 POST REF
BETWEEN STUDS AND VAPOR BARRIER OVER58"AND GYP. (8CM) DW
PRESSURE TREATED
DRYWALL FINISH. TAPE & PAINT
VINYL SIDING AT EACH
SIDE
2'-6" 7'-9" 7'-9" SMOKE / CO
DETECTOR
(CLASS 1 FINISH) 10'-9" SMOKE / CO SMOKE / CO
3 DETECTOR
4" PLYWOOD 1 LAYER ON EACH DETECTOR
SIDE SCREW ATTACH
NEW 24" X 24" X 12" 2 SUNROOM
CONC. FOOTING UNDER 7'-0"
NEW POST
2 X 4 WOOD STUDS
KITCHEN HOOD
TO BE 100CFM
2 NEW FLOORING
NEW 5' SLIDING NEW FLOORING
1 PATIO DOOR NEW FLOORING
9'-1112"
A300
SIMPSON BEDROOM BEDROOM
STRONG TIE 6x6 TRTD. NEW FOOTINGS
POST BASE COLUMN UNDER EXISTING
CBSQ66 HDG SUNROOM 10'-6"
PRESSURE TREATED FOR 6X6 POST
BOTTOM PLATE OR EQUAL
1 1/4"X6
1
FINISH GROUND DECKING 2X6 @
SIMPSON LEVEL
STRONG TIE 16"O.C.
POST BASE
UNDISTURBED NOTE: USE A NEW 2 X 6
CBSQ66 HDG
FOR 6X6 POST
SOIL SONOTUBE 10'-3" ROOF 13'-2"
TO FORM PEDESTAL
RAFTERS
OR EQUAL
4 - #5 REBAR MIN. CAST -IN-PLACE NEW WOOD DECK
12" DIAMETER
VERTICAL CONCRETE PEDESTAL
#3 - REBAR
4 - #5 REBAR
TIES 18" O.C. NEW RUBBER ROOF MEMBRANE OVER NEW EXTERIOR WALL
VERTICAL
2'-0"
3
BUILDING PAPER OVER NEW
4" CDX PLYWOOD WITH NEW ROOF
CAST-IN-PLACE SHEATHING OVER 2 X 6 RAFTERS @ 16" O.C
CONCRETE 2
3'-33 4"
#3 - REBAR
FOOTING
3 - #5 REBAR FIRST FLOOR PLAN: PROPOSED A300
TIES 18" O.C. 1'-0" @ 8" O.C. SCALE : 1/4" = 1'-0"
EACH DIRECTION
O 2' 4' 8'
3" CLEAR
2'-0" 6" 1'-0" 6"
CAST -IN-PLACE 2'-0"
12" DIAMETER
CONCRETE PEDESTAL
NEW PLUMBING
1 FOUNDATION/FOOTING DETAIL FIXTURES, TILE WALLS
A-300 SCALE: NTS AND FLOORING
4'-6" 10'-9"
NEW RUBBER ROOF MEMBRANE OVER
3
BUILDING PAPER OVER NEW
4" CDX
SIMPSON TIES
PLYWOOD SHEATHING OVER 2 X 8 JOIST HANGERS
OR EQUAL UP
RAFTERS @ 16" O.C
NEW R-38 INSULATION
SMOKE / CO
DETECTOR
BATH RM STORAGE
18'-5" NOT TO BE USED
SIMPSON TIES AS BEDROOM
EXISTING FURNACE
12'-0"
NEW RUBBER ROOF MEMBRANE OVER JOIST HANGERS
3 OR EQUAL TO REMAIN
REVISIONS
13'-6"
BUILDING PAPER OVER NEW
4" CDX
NEW 2 X 6 LOUVER
WASHER DRYER
PLYWOOD SHEATHING OVER 2 X 6
NEW GUTTER LEDGER BEAM RAFTERS @ 16" O.C DOOR FOR
NO. DATE DESCRIPTION
AND FASCIA TO MATCH WITH21"Ø LAG LDRY RM SMOKE / CO
COMBUSTION AIR
FOR HWH AND FURNACE NEW FLOORING
9'-7"
DETECTOR 1 3-25-24
BOLTS F-1 REVISIONS
FD FD SMOKE / CO
6'-4" 8'-10" NEW FLOORING DETECTOR
NEW 2 X 6 LEDGER BEAM
MECH. RM.
HWH
WITH21"Ø LAG BOLTS
NEW GUTTER ELEC. PANEL
NEW SIDING OVER BUILDING PAPER 34" OVER AND FASCIA TO MATCH ALL DAMAGED DRYWALL
TO BE REMOVED AND REPLACED
EX.T PLYWOOD OVER 2 X 4 WD STUDS @ 16"
O.C AND R-19 INSULATION IN BETWEEN STUDS NEW VINYL FLOORING DRAWN BY: ----- -----@pmpcarch.com
AND VAPOR BARRIER OVER 58 AND
" GYP. OVER CONC. SLAB CHECKED BY: JON jon@pmpcarch.com
DRYWALL FINISH. TAPE & PAINT EXISTING FURNACE AND HOT WATER EXISTING DATE ISSUED:
18'-314"
EXISTING 6" SLAB CONNECTED TO EXISTING CHIMNEY #5 (T&B) DOWELED 6" INTO 6" CONC. SLAB
THE EXISTING FOUNDATION NEW FLOORING PROJECT ADDRESS:
ON GRADE W/EPOXY GROUT AND EXTENDED
2'-0" INTO NEW GRADE BEAM STEP GRADE BEAM SMOKE / CO
DOWN TO BOTTOM DETECTOR
+0'-0" GRADE LEVEL
VINYL SIDING OVER BUILDING PAPER OVER
3
4" EXT. PLYWOOD OVER 2 X 4 WD STUDS @
OF EXISTING FOOTING ROSS PO N
16" OVER34" EXT. PLYWOOD OVER VINYL 1 FAMILY RM 11'-9"
SIDING A300 S O E L
NEW21" Ø X 6" EXPANSION NEW 1'-0" X 3'-6" GRADE BEAM
3'-6" MIN.
ANCHOR @ 3'-0" O.C. PRESSURE TREATED
W/2-#5 CONT. T&B 23'-0"
EMBEDDED 6" INTO NEW BOTTOM PLATE (BOTTOM OF GRADE BEAM
TO BE MIN. 3'-6" BELOW GRADE #5 (T&B) DOWELED 6" INTO
GRADE BEAM
THE EXISTING FOUNDATION
W/EPOXY GROUT AND EXTENDED
PERMIT #:
+0'-0" GRADE LEVEL 2'-0" INTO NEW GRADE BEAM
8" CONC. PIER
NEW21" Ø X 6" EXPANSION
2-#5 ANCHOR @ 3'-0" O.C. 42" BELOW GRADE
EMBEDDED 6" INTO EXISTING
T&B FOUNDATION WALL
PROPOSED PLANS
UP
AND SCHEDULES
1'-0" 6X6 COLUMN FD
EXISTING FOUNDATION
WALL TO REMAIN BASEMENT PLAN: PROPOSED
SCALE : 1/4" = 1'-0" COVERED BASEMENT
A300
O 2' 4' 8' STAIRS
TYP. WALL SECTION @ SUNROOM
1 NTS
2 TYP. WALL SECTION
NTS
COPYRIGHT 2025 PRASHANTH MAHAKALI P.C.
NEW RUBBER ROOF MEMBRANE OVER
3
BUILDING PAPER OVER NEW
4" CDX
EXISTING ROOF OVER PLYWOOD SHEATHING OVER 2 X 6
CARPORT TO REMAIN RAFTERS @ 16" O.C
NEW FASCIA AND GUTTERS
EXISTING 2 X 10
RAFTERS @ 16" 0.C.
TO REMAIN EXISTING 2 1 NEW SIDING OVER BUILDING
BLG. PAPER OVER34" EXT.
PLYWOOD OVER 2 X 4 WD
NEW 6 X 6 POST STUDS @ 16" OVER 3
4" EXT.
PRESSURE TREATED PLYWOOD OVER VINYL
SIDING
NEW 24" X 24" X 12" 3'-6" NEW 24" X 24" X 12" 3'-6" NEW SIDING OVER BUILDING
3
CONC. FOOTING UNDER CONC. FOOTING UNDER PAPER OVER 4" EX.T PLYWOOD
NEW POST NEW POST OVER 2 X 4 WD STUDS @ 16" O.C
SEE DETAIL 1 SHEETA300 SEE DETAIL 1 SHEETA300 AND R-19 INSULATION IN BETWEEN
STUDS AND VAPOR BARRIER OVER
AND58" GYP. DRYWALL FINISH. TAPE
& PAINT
EAST ELEVATION: PROPOSED
SCALE : 1/4" = 1'-0"
O 2' 4' 8'
NEW RUBBER ROOF
MEMBRANE OVER
BUILDING PAPER OVER NEW3 NEW RUBBER ROOF MEMBRANE OVER
4" 3
EXISTING ROOF OVER CDX PLYWOOD SHEATHING BUILDING PAPER OVER NEW
4" CDX
CARPORT TO REMAIN OVER 2 X 8 RAFTERS @ 16" O.C PLYWOOD SHEATHING OVER 2 X 6
NEW R-38 INSULATION RAFTERS @ 16" O.C
T/O BUILDING
14' - 0"
MEAN HEIGHT
11' - 6"
NEW FASCIA AND GUTTERS
ATTIC
8' - 10"
EXISTING 2 X 10
RAFTERS @ 16" 0.C.
TO REMAIN
NEW SIDING OVER BUILDING EXISTING
BLDG. TO REMAIN 8'-0"
FIRST FLOOR
0' - 10"
10" GRADE
0' - 0"
NEW SIDING OVER BUILDING
3'-6"
NEW 6 X 6 POST NEW SIDING OVER BUILDING PAPER OVER34" EXT.
NEW 24" X 24" X 12" PRESSURE TREATED 3 PLYWOOD OVER 2 X 4 WD
CONC. FOOTING UNDER PAPER OVER 4" EX.T PLYWOOD NEW SLIDING DOOR
3
OVER 2 X 4 WD STUDS @ 16" O.C STUDS @ 16" OVER 4" EXT.
NEW POST
AND R-19 INSULATION IN BETWEEN PLYWOOD OVER VINYL
SEE DETAIL 1 SHEETA300
STUDS AND VAPOR BARRIER OVER SIDING
AND58" GYP. DRYWALL FINISH. TAPE
SOUTH ELEVATION: PROPOSED & PAINT
SCALE : 1/4" = 1'-0" REVISIONS
O 2' 4' 8'
NO. DATE DESCRIPTION
1 3-25-24 REVISIONS
DRAWN BY: ----- -----@pmpcarch.com
CHECKED BY: JON jon@pmpcarch.com
EXISTING 2 X 10
RAFTERS @ 16" 0.C. EXISTING ROOF OVER DATE ISSUED:
TO REMAIN CARPORT TO REMAIN
PROJECT ADDRESS:
T/O BUILDING
14' - 0"
44 OSS OINT
MEAN HEIGHT S O IE IL
11' - 6"
ATTIC
8' - 10"
NEW FASCIA AND GUTTERS PERMIT #:
NEW 6 X 6 POST
PRESSURE TREATED
EXISTING
EXISTING BLG.
BLG.
ELEVATIONS
FIRST FLOOR
0' - 10"
GRADE
0' - 0"
COPYRIGHT 2025 PRASHANTH MAHAKALI P.C.
NORTH ELEVATION: PROPOSED
SCALE : 1/4" = 1'-0"
O 2' 4' 8'
NEW 24" X 24" X 12"
CONC. FOOTING UNDER
NEW POST
SEE DETAIL 1 SHEETA300
3'-6"
A400
with new detached garage
ROOF RIDGE
EL 24'-9"
9023 NILES CENTER RD
2ND FLOOR ADDITION
9023 NILES CENTER RD
SKOKIE, IL 60076
2TH FLOOR
EL 10'-8"
ARCHITECT OF RECORD
VARIATION DESIGN LLC
CONTACT KLARKE ZHAOCHEN WANG, AIA
TEL (626)675-0052
EMAIL VARIATIONDESIGNLLC@GMAIL.COM
1ST FLOOR PROFESSIONAL DESIGN FIRM # 184.007945-0001
EL 0'-0"
BASEMENT
EL -8'-4" V.I.F.
3 4
ROOF RIDGE
EL 24'-9"
DATE NO. REMARKS
2ND FLOOR
EL 10'-8"
1ST FLOOR
EL 0'-0"
REVISIONS
SHEET TITLE
PROPOSED
ELEVATIONS
BASEMENT
EL -8'-11" V.I.F.
PHASE:
SCALE:
3 4
DATE:
SHEET NUMBER
A3
9023 NILES CENTER RD
2ND FLOOR ADDITION
9023 NILES CENTER RD
SKOKIE, IL 60076
ARCHITECT OF RECORD
VARIATION DESIGN LLC
CONTACT KLARKE ZHAOCHEN WANG, AIA
TEL (626)675-0052
EMAIL VARIATIONDESIGNLLC@GMAIL.COM
PROFESSIONAL DESIGN FIRM # 184.007945-0001
DATE NO. REMARKS
REVISIONS
SHEET TITLE
PROPOSED FLOOR
PLANS AND NOTES
2 PHASE:
A3 SCALE:
DATE:
N -1 N 1 N 2 SHEET NUMBER
A1
9023 NILES CENTER RD
2ND FLOOR ADDITION
9023 NILES CENTER RD
SKOKIE, IL 60076
ARCHITECT OF RECORD
VARIATION DESIGN LLC
CONTACT KLARKE ZHAOCHEN WANG, AIA
TEL (626)675-0052
EMAIL VARIATIONDESIGNLLC@GMAIL.COM
PROFESSIONAL DESIGN FIRM # 184.007945-0001
DATE NO. REMARKS
REVISIONS
SHEET TITLE
PROPOSED ROOF
PLAN, SCHEDULES
AND NOTES
PHASE:
N 1 SCALE:
DATE:
SHEET NUMBER
A2
9023 NILES CENTER RD
2ND FLOOR ADDITION
9023 NILES CENTER RD
SKOKIE, IL 60076
ARCHITECT OF RECORD
VARIATION DESIGN LLC
CONTACT KLARKE ZHAOCHEN WANG, AIA
TEL (626)675-0052
EMAIL VARIATIONDESIGNLLC@GMAIL.COM
PROFESSIONAL DESIGN FIRM # 184.007945-0001
DATE NO. REMARKS
REVISIONS
SHEET TITLE
GARAGE
PHASE:
SCALE:
DATE:
SHEET NUMBER
A6
NEW ADDITION OF 2ND FLOOR AND GARAGE TO EXISTING DETACHED HOUSE
NEW CONSTRUCTION - SINGLE FAMILY RESIDENCE
SINGLE FAMILY RESIDENCE
9023 NILES CENTER RD, SKOKIE, IL 60076
9023 NILES CENTER RD
2ND FLOOR ADDITION
9023 NILES CENTER RD
SKOKIE, IL 60076
ARCHITECT OF RECORD
VARIATION DESIGN LLC
CONTACT KLARKE ZHAOCHEN WANG, AIA
TEL (626)675-0052
EMAIL VARIATIONDESIGNLLC@GMAIL.COM
PROFESSIONAL DESIGN FIRM # 184.007945-0001
COVER SHEET, GENERAL NOTES, CODE MATRIX AND SITE PLAN MECHANICAL FLOOR PLANS AND SCHEDULES
MECHANICAL DIAGRAMS AND NOTES
DEMOLITION PLANS AND NOTES
ELECTRICAL PLANS, DIAGRAMS AND NOTES
PROPOSED FLOOR PLAN AND NOTES
PROPOSED ROOF PLAN, ROOM, SCHEDULES AND NOTES PLUMBING DIAGRAMS, SCHEDULES AND NOTES DATE NO. REMARKS
PROPOSED ELEVATIONS
BUILDING SECTION AND FRAMING PLAN
JOIST DETAILS
CERTIFICATION STATEMENT SCOPE OF WORK NILES CENTER RD
I HEREBY CERTIFY THAT THESE DRAWINGS
ARE PREPARED BY ME OR UNDER MY
SUPERVISION AND TO THE BEST OF MY
REVISIONS
PROFESSIONAL KNOWLEDGE CONFORM TO
SKOKIE IL BUILDING CODES. SHEET TITLE
APPLICABLE CODES COVER SHEET,
N
1 GENERAL NOTES,
CODE MATRIX AND
SITE PLAN
PHASE:
SCALE:
DATE:
SHEET NUMBER
SIGNED
EXPIRED 11/30/2024
T1
9023 NILES CENTER RD
2ND FLOOR ADDITION
9023 NILES CENTER RD
SKOKIE, IL 60076
ARCHITECT OF RECORD
VARIATION DESIGN LLC
CONTACT KLARKE ZHAOCHEN WANG, AIA
TEL (626)675-0052
EMAIL VARIATIONDESIGNLLC@GMAIL.COM
PROFESSIONAL DESIGN FIRM # 184.007945-0001
DATE NO. REMARKS
REVISIONS
SHEET TITLE
FRONT FACADE
RENDERING
The image is a rendering only. The color as shown may vary from existing condition.
The entire 2nd floor addition is intended to be applied with the same brick veneer matching texture and color of the existing 1st floor. PHASE:
SCALE:
DATE:
SHEET NUMBER
T2
FRONT
REAR
SIDE
SIDE
NEIGHBORS
F
RONTE
NTRYE
LEVA
TION
FI
NISH LEGEND
SHERWI
NWI
LLI
AMS“
REPOSEGRAY”
SHERWI
NWI
LLI
AMS“
IRONORE”
SHERWI
NWI
LLI
AMS“
PAVESTONE”
SHERWI
NWI
LLI
AMS“
ORI
GAMIWHI
TE”
SHERWI
NWI
LLI
AMS“
ROOKWOODRED”
SHERWI
NWI
LLI
AMS“
PEPPERCORN”
SHERWI
NWI
LLI
AMS“
BLACKMAGI
C”
SUNBRELLA“
BEAUFORTCLASSI
C”
SUNBRELLA“
DUBONNETTWEED”
SUNBRELLA“
BLACK”
SI
DEE
LEVA
TION WOOD-
LOOKPLAN“
DARKWALNUT”
DATE:06-
07-
2022
Col
oredEl
evat
ions SCALE:1/
8”=1’
-0” GHAAr
chi
tect
ure/Devel
opment
MAGGIANO’SLI
TTLEITAL
Y 14901Quor um Dr
ive,Suit
e300
0 8
Ol
dOrchar
d-Skoki
e,I
L Dal
las,Texas75254972.239.8884
Village of Skokie
APPEARANCE COMMISSION APPLICATION
Community Development Department - Building & Inspection Services Division
5127 Oakton St. Skokie, IL 60077
Phone 847/933-8223
The Appearance Commission meets the 2nd Wednesday* of each month at 7:30 p.m.
*Unless otherwise noted
Applications will only be accepted in a PDF format.
APPLICATION DATE: 3/27/2024
_____________________________________
APPLICATION TYPE (Please check all that apply): (TENANT BUILD-OUT)
New Construction 1st Floor Addition 2nd Floor Addition Façade Signage X Other
LAND USE:
Single Family Residential Multifamily Residential Mixed Use X Commercial Industrial Other
4999 OLD ORCHARD SHOPPING CENTER, SUITE A28A, SKOKIE, IL 60077
SUBJECT ADDRESS: ___________________________________________________________________________
OWNER INFORMATION: Please print legibly.
NAME(S): ALEXIOS GEORGES
ADDRESS: 4999 OLD ORCHARD SHOPPING CTR, STE A28A CITY, STATE ZIP: SKOKIE, IL 60077
PHONE#: 312-502-8994 EMAIL: ALEX@CUPITOL.COM
AGENT/PETITIONER INFORMATION (if other than owner):
NAME(S): LASZLO SIMOVIC DAYTIME PHONE #: 773-338-2225
____________________________
ADDRESS: 6512 N. ARTESIAN AVE. CITY, STATE ZIP: CHICAGO, IL 60645
______________________________
EMAIL: LSAOFFICE@LASZLOARCH.COM SIGNATURE: __________________________________
Please submit the following PDFs to appearance@skokie.org to complete your digital-only application:
1. Elevations, floor plans, and site plans. Scale ¼” = 1’-0” is preferred, but not required. If the file size is greater
than 5MB, multiple emails are allowed. Ensure “Appearance Commission PDF” and the project’s property
address are in the subject line of the email. Color elevations or one color rendering is required.
2. Completed Zoning Information Worksheet (residential projects only) N/A, NON-RESIDENTIAL
3. Photographs (all sides of the subject building and the fronts of neighboring buildings)
4. Excerpts of brochures and/or cut sheets of new materials and colors proposed for the project. Matching
existing materials and colors can be confirmed with the submitted photographs.
5. Plat of Survey
Does your project include a green roof? Yes No X
* If your project includes a green roof you will placed at or near the top of the agenda.
Fee Schedule
Residential Site (new) … $100 plus $50.00 per unit
Non-Residential Site* (new) … $100 plus $50.00 per 1,000 square feet (based on square footage of building)
* Any non-residentially zoned site (Business, Industrial, Mixed-Use districts)
Any Other Appearance Review (Additions, Façade, Sign Package, etc.) … $50.00
If you have already paid for a preliminary plan review there is no charge.
For Office Use Only:
Case Number ____________________________ Meeting Date ________________________________________________
Acct # NR Amt $ _________________________ Cash / Credit Card/ Check # ____________________________________
Any required fees or monies owed by the applicant to the Village must be paid as a condition of approval .
VOSDOCS-#149808-v15-Appearance_Commission_Application_form Revised 12/4/23
INDEX OF DRAWINGS:
T-0: COVER SHEET
"CUPITOL"
T-1: RENDERINGS
LASZLO SIMOVIC, ARCHITECTS, L.L.C.
T-3: EXTERIOR SAMPLE BOARD
ARCHITECTURAL:
TEL: 773-338-2225
A-0.1: BARRICADE PLAN
A-0.2: BARRICADE ELEVATIONS
A-1: NOTES AND LEGENDS
NEW RESTUARANT SUITE A28A A-2: EXISTING BASEMENT PLAN
A-3: DEMO 1ST FLOOR PLAN
6512 N. ARTESIAN AVE.
CHICAGO, IL. 60645-5328
A-4: DEMO ELEVATIONS
A-5: NEW 1ST FLOOR PLAN
A-6: NEW ROOF PLAN
A-7: NEW ELEVATIONS
A-8: BUILDING SECTIONS
4999 OLD ORCHARD SHOPPING CENTER SALES AREA CEILING GENERAL NOTES:
1. ACT OR LAY-IN TILE CEILING IS PROHIBITED AT FRONT-OF-HOUSE / A-9: WALL SECTIONS
SUITE A28A
SALES AREA AND WHERE OPENLY VISIBLE AT ANY BOH AREAS BY
MEANS OF PASS-THROUGH WINDOWS.
EMAIL: LASZLO@LASZLOARCH.COM
2. SECURITY CAMERAS WITHIN SALES AREA MUST BE DOME-TYPE AND
LIFE SAFETY:
SKOKIE, IL 60077 RECESSED WITHIN CEILING. ANY EXPOSED HOUSING MUST BE
PAINTED TO MATCH CEILING FINISH COLOR, NO EXCEPTIONS. SUBMIT LS-1 LIFE SAFETY PLANS
FAX: 773-338-2226
CUT SHEET FOR REVIEW AND APPROVAL. NO CLG MOUNTED
SECURITY FIXTURES, MUST BE FULLY CONCEALED. NO CLG MOUNTED
MONITORS.
STRUCTURAL:
3. SPRINKLERS WITHIN SALES AREA MUST BE RECESSED AND S-1:
CAPPED. S-2:
SPRINKLER CAPS MUST MATCH COLOR OF ADJACENT CEILING FINISH, S-3:
OWNER / DEVELOPER
NO EXCEPTIONS. *CAPS ARE NOT ALLOWED TO BE PAINTED IN-FIELD S-4:
AND MUST BE SUPPLIED COLORED BY MANUFACTURER, PER CODE.
MECHANICAL:
4. HVAC DIFFISUSERS AND RETURNS WITHIN SALES AREA MUST BE
ARCHITECTURAL LINEAR OR SINGLE PLATE (SEE OMNI BY TITUS HVAC
MR. CHRIS GEORGES OR SIMILAR). DIFFUSERS AND RETURN AIR GRILLES MUST MATCH
COLOR OF ADJACENT CEILING FINISH, NO EXCEPTIONS. SUBMIT CUT
M-1:
M-2:
CUPITOL
SHEETS AND SPECIFY WITHIN MECHANICAL DRAWINGS FOR REVIEW
AND APPROVAL. M-3:
5. EMERGENCY LIGHTS MUST BE THROUGH SPECIFIED M-4:
ARCHITECTURAL LIGHTING BY USING E-INVERTER (OR SIMILAR). NO
BUG-EYES ALLOWED. EMERGENCY EXIT SIGNS SHALL BE EDGE-LIT
ELECTRICAL:
ARCHITECT
BLADE TYPE WITH RECESSED BALLAST (WALL OR CEILING MOUNT).
SUBMIT CUT SHEET FOR REVIEW AND APPROVAL.
6. ALL ACCESS PANELS AND HARDWARE MUST BE FINISHED TO MATCH E-1:
ADJACENT CEILING COLOR FINISHES, NO EXCEPTIONS. DRYWALL E-2:
LASZLO SIMOVIC E-3:
ACCESS PANELS (SUCH AS MOONLIGHT MOLDS) ARE STRONGLY
PREFERRED OVER METAL HINGED DOORS. CONSULT GC WHERE BEST
APPLICABLE. ACCESS PANELS SHOULD BE LOCATED AWAY FROM
E-4:
01/30/2024
LASZLO SIMOVIC ARCHITECTS, LLC FOCAL POINT AREAS.
7. IF OPEN CLG THEN FIRST 10'+/- MUST BE GYP BOARD WITH
PLUMBING: 02/16/2024 01/19/2024 01/19/2024 DATE:
RECESSED FIXTURES.
6512 N. ARTESIAN AVE 8. TRACK LIGHTS MAY NOT BE SURFACE MOUNTED ON SHEET ROCK.
CLGS TRACK LIGHTS NEED TO BE FULLY RECESSED EITHER 1.IN
P-1:
P-2:
CHICAGO, IL 60645
RECESSED NICHE OR 2. A SPEC WITH FULLY RECESSED TRACK
(TAPED INTO CLG) IS SUBMITTED TO & APPROVED BY URW. P-3:
9. TRANSFER GRILLS ARE REQUIRED FOR SMOKE EVAC IN CERTAIN P-4:
Design Review Added Supply/Waste
AREAS OF THE CENTER (SEE CRITERIA). GRILLS SHOULD BE LINEAR
Design Review Reflected Clg Plan
AND PAINTED TO MATCH THE WALLS.
STRUCTURAL ENGINEER
PROGRESS PRINTING
______________________
DESCRIPTION:
______________________
Design Review Design Review
OLD ORCHARD ROAD
______________________
MEP ENGINEER
NO.
______________________
______________________ FOREVER XXI
______________________ BLOOMINGDALES
LANDLORD
WESTFIELD OLD ORCHARD
CONTACT: JINYOUNG JANG LEASE OUTLINE DRAWING
PHONE: 872-227-4067
1.THIS LOD IS DIAGRAMMATIC ONLY. ACTUAL
EMAIL: JINYOUNG.JANG@URW.COM CONDITIONS MAY VARY.
2.INDICATE LEASE LINE ON ALL PLANS.
3.FIELD VERIFY ALL CONDITIONS PRIOR TO START
OF WORK.
4.TENANT MUST VERIFY ALL CONDITIONS PRIOR
TO START OF WORK AND ADHERE TO ALL
4999 OLD ORCHARD
DPT3 DIMENSIONS INDICATED ON THE LEASE OUTLINE
DOCUMENT.
PROJECT:
5.NO TENANT BUILD-OUT (STOREFRONT,
PARKING PARKING
FINISHES, FRONT COUNTER, EQUIPMENT, DOORS
SHOPPING CENTER
DECK DECK
SWING, ETC.) IS PERMITTED BEYOND TENANT
LEASE LINE UNLESS APPROVED BY LANDLORD.
LAWLER AVE
PRELIMINARY DRAWING REVIEW
STE A28A
APPROVED ✔ APPROVED AS NOTED RESUBMIT
NEW RESTAURANT
SKOKIE BOULEVARD
Landlord review is for design intent and compliance with Landlord’s criteria ONLY. DPT 2
SKOKIE, IL 60077
It is the responsibility of the Tenant, Tenant’s Consultants, and Tenant’s General MACY'S
Contractor to field verify all site conditions to ensure the work represented herein,
satisfactorily meets Landlord’s design criteria and the requirements of all local,
state, and Federal building codes, laws, acts, rules, regulations, ordinances,
permitting requirements, inspections, and reviews, including but not limited to the
Americans with Disabilities Act, and Fire Life Safety. Approval of Tenant’s plans
by Landlord does not constitute an assumption of responsibility by Landlord for
their accuracy or sufficiency as intended for construction or permitting, and in no
way supersedes any provision of Tenant’s Lease.
tricia.zeitler 3/4/2024
URW REPRESENTATIVE DATE
RETAIL DESIGN MANAGER GENERAL NOTES (if applicable):
"CUPITOL"
1. TENANT DESIGN REPRESENTATIVES AND GC. TO VERIFY ALL FIELD DIMENSIONS AND CONTACT TC WITH ANY SITE
DISCREPENCIES THAT MAY AFFECT THE DESIGN.
AREA OF WORK
2. DURING CONSTRUCTION, TENANT DESIGN PROFESSIONALS OF RECORD ARE RESPONSIBLE TO BE ON SITE TO
FIELD VERIFY CONSTRUCTION PROGRESS AND EVALUATE POSSIBLE ISSUES CAUSED BY SITE CONDITIONS. ALL
CHANGES MUST BE REVIEWED AND DISCUSSED WITH THE TC.
AREA OF WORK 3. TENANT IS TO BUILD WHAT IS REPRESENTED IN THESE DRAWINGS ALONG WITH LANDLORD COMMENTS. IF THERE
ARE CHANGES DUE TO TENANT’S INTERNAL OPERATIONS/DECISIONS, EXISTING CONDITIONS, OR BUILDING
DEPARTMENT COMMENTS THEN THE TENANT ARCHITECT MUST PROMPLY ISSUE A SKETCH DRAWING (SK) TO
LANDLORD FOR FURTHER APPROVAL. TENANT IS RESPONSIBLE TO RETAIN ARCHITECT FOR SUCH DRAWINGS AS
ARE NECESSARY. NON-CONFORMING WORK WILL BE REJECTED AND THE TENANT WILL BE RESPONSIBLE FOR THE
COST ASSOCIATED WITH RECTIFYING THE WORK AS REQUESTED BY URW.
4.TENANT GC TO HAVE LANDLORD REVIEWED DRAWINGS ONSITE AT ALL TIMES.
5.TENANT ARCHITECT IS RESPONSIBLE FOR CHECKING ALL LOCAL & ADA CODE COMPLIANCE. FOR RENOVATIONS
TENANT'S ARCHITECT IS RESPONSBILE TO REVIEW CODE & BRING STORE UP TO CURRENT CODES AS NEC.
6. TENANT’S GENERAL CONTRACTOR SHALL BE RESPONSIBLE TO PROPERLY PROTECT ANY COMMON AREAS
SURROUNDING THE LEASE PREMISE OR COMMON AREAS BEING UTILIZED AS PATH OF TRAVEL.
7. ANY COMMON AREAS DETERMINED TO BE DAMAGED BY THE TENANT’S GENERAL CONTRACTOR, REPAIRS AND ANY
COSTS INCURRED IS THE RESPONSIBILITY OF THE TENANT’S GC. OWNER:
8. NO TENANT FINISH MAY PROJECT BEYOND LEASE LINE.
9. STOREFRONT MUST BE SELF SUPPORTING. TENANT CAN ONLY USE LANDLORD BULKHEAD FOR LATERAL
____________
SUPPORT.
10. ANY STRUCTURAL STEEL REQUIRED FOR STOREFRONT MUST BE FURNISHED AND INSTALLED BY TENANT.
11.TENANT MUST MAINTAIN 10’-0” CLEAR FIRE COORIDOR IN FRONT OF LEASE LINE. NO EXCEPTIONS.
____________
12.TENANT TO RELOCATE ANY LIFE SAFETY KNOX BOX/HORN/STROBE/SPEAKER DEVICES THAT ARE CURRENTLY
LOCATED ON THEIR STOREFRONT TO THEIR NEW STOREFRONT.
13.STOREFRONT METAL TO BE MIN OF .063 THINKNESS TO AVOID OIL CANNING/CRIMPING AT FASTENERS. PARKING
14.TENANT TO SUBMIT MATERIAL SAMPLE BOARD FOR LANDLORD APPROVAL PRIOR TO START OF CONSTRUCTION. DECK
NO MATERIAL CONSIDERED APPROVED UNTIL MATERIAL SAMPLES ARE RECEIVED AND REVIEWED BY LANDLORD. SHEET NAME:
RETENTION
15.TENANT TO SUBMIT SIGN SHOP DRAWINGS UNDER SEPARATE COVER FOR LANDLORD APPROVAL. NO SIGNS
CONSIDERED APPROVED UNTIL ALL SHOP DRAWINGS ARE RECEIVED AND REVIEWED BY LANDLORD. DPT 1 Cover Sheet
16. NO COLOR CHANGING LIGHTS OR SIGNS ON STOREFRONT. NORDSTROM
POND
17. OPEN CLGS ONLY PERMITTED WITH SPECIAL APPROVAL AND NOT WITHIN 5' OF LEASE LINE.
18. OPEN CEILING ON SALES FLOOR MUST UTILIZE CABLE TRAYS IF RIGID CONDUIT IS NOT USED. NO LOOSE MC
CABLE OR LOOSE WIRING.
19. OPEN CEILING ON SALES FLOOR MUST HAVE RIGID DUCTWORK (NO FLEX DUCTS).
20. DIGITAL MONITORS TO BE SET BACK AT LEAST 5' FROM LEASE LINE.
PROJECT: 7438
21. ALL TVS /MONITORS /LIGHT BOXES MUST BE RECESSED INTO WALL OR BE FRAMED OUT WITH ONLY SCREEN
VISIBLE - NO VISIBLE CORDS - SCALE: AS NOTED
22.ALL SPRINKLER HEADS MUST BE RECESSED WITH COVER TO MATCH CEILING.
23.ALL EMERGENCY AND EXIT LIGHTING IN SALES AREA MUST HAVE RECESSED BASE AND BE FLUSH / EDGE-LIT LED DATE: 08/20/2023
(GREEN LETTERS)- NOT SURFACE MOUNTED. NO "BUG-EYES" PERMITTED IN SALES AREA.
24.MINIMUM PASSAGE WIDTH 36" CLEAR AISLES. TYPICAL THRU-OUT
25. NO ADDITIONAL DISPLAYS, FURNITURE, SIGNS AND ACCESSORIES ARE ALLOWED OTHER THAN THE ITEMS
PRESENTED ON THE DESIGN PACKAGE. CHANGES TO THE CONCEPT’S LAYOUT AND DESIGN MUST BE SUBMITTED
FOR REVIEW AND APPROVAL BY THE TCM.
26. VISUAL COMMUNICATION: ALL DESCRIPTIONS AND PRICING SHOULD BE PROFESSIONALLY DESIGNED AND
GOLF ROAD
T-0
PRINTED. ENSURE TICKETING IS LAMINATED AND CONSISTENT IN APPEARANCE. PROFESSIONAL TICKET HOLDERS
ARE TO BE USED AND PLACED IN A CONSISTENT FORMAT. REFER TO VISUAL COMMUNICATION GUIDE SUMMARY FOR
ADDITIONAL INFORMATION.
27. TRASH CANS MUST BE FULLY CONCEALED FROM CUSTOMER LINE OF SIGHT, BEHIND COUNTER OR BUILT INTO
THE MILLWORK.
N N
SITE PLAN KEY PLAN
28. ALL STAFF’S PERSONAL ITEMS MUST BE HIDDEN AT ALL TIMES. PERSONAL ELECTRONICS MAY NOT BE PLACED ON
THE DISPLAYS AND COUNTERTOPS.
29. ALL COUNTER TASK LIGHTING LIKE DESK LAMPS ETC. MUST BE OUT OF CUSTOMER VISIBITY AND WIRING TO BE
CONCEALED WITHIN MILLWORK. FIXTURE FINISH TO BE COHERENT WITH OVERAL PALETTE OF CONCEPT.
SCALE: N.T.S. 30. NO EXPOSED SECURITY PEDS OR DOOR MAX, SECURITY SYSTEMS MUST BE FULLY CONSEALED. SCALE: 1" = 200'
Tenant to submit sign shop drawings for landlord
approval prior to start of construction. No sign
considered approved until sign shop drawings
LASZLO SIMOVIC, ARCHITECTS, L.L.C.
are received and reviewed by Landlord.
TEL: 773-338-2225
6512 N. ARTESIAN AVE.
CHICAGO, IL. 60645-5328
EMAIL: LASZLO@LASZLOARCH.COM
FAX: 773-338-2226
02/16/2024 01/30/2024 01/19/2024 01/19/2024 DATE:
Design Review Reflected Clg Plan Design Review Added Supply/Waste
PROGRESS PRINTING
Design Review Design Review DESCRIPTION:
NO.
EAST ELEVATION RENDERING
SCALE: N.T.S.
Cupitol is responsible for
re-building this pier
examples or modern planters
LANDLORD COMMENTS
Tenant must return side
back at least 5' and
preferrably to die into
bulkhead beyond. False
4999 OLD ORCHARD
BLADE SIGN - SEE
fronts are no longer
PROJECT:
LOCATION AND SIZE IN
CRITERIA.
permitted. No exceptions.
SHOPPING CENTER
WE WILL ALLOW ROUND
BUT MUST BE MOUNTED
AT CORRECT HEIGHT
STE A28A
ADN NO MORE THAN 18"
NEW RESTAURANT SKOKIE, IL 60077
storefront needs lighting
element such as sconces.
otherwise propose
alternative lighting
element.
OWNER:
____________
____________
SHEET NAME:
Renderings
PROJECT: 7438
SCALE: AS NOTED
DATE: 08/20/2023
Storefront needs green
element to soften it. Add
planters.
T-1
EXTERIOR SAMPLE BOARD ONLY
LASZLO SIMOVIC, ARCHITECTS, L.L.C.
TEL: 773-338-2225
6512 N. ARTESIAN AVE.
CHICAGO, IL. 60645-5328
EMAIL: LASZLO@LASZLOARCH.COM
FAX: 773-338-2226
where is this lighting?
hanging off canopy?
please show in next round.
02/16/2024 01/30/2024 01/19/2024 01/19/2024 DATE:
Design Review Reflected Clg Plan Design Review Added Supply/Waste
PROGRESS PRINTING
Design Review Design Review DESCRIPTION:
NO.
VUSUAL COMFORT & CO.
COTSWOLD LANE SMALL PENDANT. OL 5431
WINDOWS & DOOR COMBINATIONS WINDOWS & DOOR COMBINATIONS 4999 OLD ORCHARD
PROJECT:
SHOPPING CENTER
ALUMI SMARTIA 567 URBAN ALUMI SMARTIA 567 URBAN
CUPITOL - OLD ORCHARD STE A28A
PRELIMINARY DESIGN NEW RESTAURANT SKOKIE, IL 60077
SUITE 828A
FEB 23, 2024
NOTE: METAL CLADDING AT CANOPY TO MACH
ALUMNI SMARTIA 567 URBAN
OWNER:
____________
____________
SHEET NAME:
Sample Board
PROJECT: 7438
SCALE: AS NOTED
DATE: 08/20/2023
SAMPLE CLADDING EXTERIOR CLADDING
BOOST STONE - TARMAC 120X 278
T-2
LASZLO SIMOVIC, ARCHITECTS, L.L.C.
TEL: 773-338-2225
6512 N. ARTESIAN AVE.
CHICAGO, IL. 60645-5328
EMAIL: LASZLO@LASZLOARCH.COM
ROOF LEVEL BUILDING ABOVE MAGGIANO'S BSMT SLAB ON GRADE
FAX: 773-338-2226
• Barricade to be framed with 1”x4” wood, painted either black or white depending upon graphic. Barricade graphics must be full wrap, printed scrim graphic and must include the following:
Color to be approved by Westfield Tenant Coordination.
15. No Smoking Policy • Store name and opening date on graphic returns
• All exterior wood surfaces must be fully primed and painted on all exposed surfaces including the
• Website or email address for employment opportunities
Smoking is prohibited on the premises, common areas or base building construction site. edges and backs with good quality primer/paint designed for wood surfaces to ensure good
adhesion under exterior weather conditions. Paint Specifications: Glidden, exterior latex, semi- • Language related to open location in mall during construction if applicable, i.e. “Visit our Existing
gloss finish, Fauna. ID 10YY 18/074. Store near Nordstrom.”
• All plywood joints need to be screwed down to framing to eliminate bowing and warping.
16. Storefront Barricade Policy
• Install wind bracing as necessary to stabilize the barricade.
At Westfield’s option, barricades will be constructed by Westfield at General Contractor’s expense. All • Barricade must be full height. In order to accommodate installation of Tenant canopy, barricade 17. Door Name & Address
questions regarding barricade graphics requirements must be submitted to Tenant Coordinator before should be constructed in 2 sections, height of each section to be determined by height of Tenant General Contractor needs to have store name and address painted on back door. The address on the
installing the barricade. front door area should be applied with the proper address sticker. Exact location must be approved by the
canopy.
Facilities Director.
1'-6"
Barricades requirements are as follows: o Example: Barricade is 20’ high. If Tenant canopy is at 12’, lower section of barricade
16.1
•
If underneath Landlord canopy:
Barricade must be constructed of exterior-rated plywood that will not warp or delaminate with a
would be up to 12’ high (bottom of Tenant canopy AFF), upper section to be 8’. Full
wrap graphic required on lower section; upper would eventually be removed so graphic
should be different than that of lower section. Refer to illustration below.
•
•
1 inch letters for metal rear doors
4 inch height white block letters, Arial font, installed on the inside lower right side of the storefront,
2½” from bottom of glazing to bottom of letters. Furthest glazing panel on the right, right justified.
Not on doors, glazing panel only
6'-1"
smooth grade and not textured.
•
•
Barricade to be framed with 1”x4” wood, painted either black or white depending upon graphic.
Color to be approved by Westfield Tenant Coordination.
All exterior wood surfaces must be fully primed and painted on all exposed surfaces including the
edges and backs with good quality primer/paint designed for wood surfaces to ensure good
18. Quality of Workmanship
General Contractor’s work shall be performed in a through, first class and workmanlike manner and shall
3'-4"
adhesion under exterior weather conditions. Paint Specifications: Glidden, exterior latex, semi- be in good usable condition at the date of completion thereof. If in Westfield’s judgment, the General
gloss finish, Fauna. ID 10YY 18/074. Contractor’s work is not completed in a first class and workmanlike manner, Tenant will not be allowed to
• All plywood joints need to be screwed down to framing to eliminate bowing and warping. open until said discrepancies are corrected.
• Install wind bracing as necessary to stabilize the barricade.
• Barricade must be full height, to bottom of canopy or top of parapet wall.=
• Barricade to be 5’ from storefront. 19. Supervision
• Top of the barricade should have a solid lid to contain noise, conditioned air, and weather. If the General Contractor shall provide a full-time supervisor on site at all times when construction is being
barricade is open to the atmosphere, top edge shall be level and secured structurally to the performed in retailer’s space. Failure to comply will result in immediate work stoppage until such time as
building. At no time whatsoever will sandbags or water barrels be allowed. said supervisor is present.
• Paver flooring inside the barricade must be protected.
• Doors are allowed on the barricade if the premises does not have a back door. Door must be pre-
10'-3"
hung, finished, & trimmed. 20. Approved Design
• General Contractor must provide Facilities Director with a key to the premises. • Barricade to be 5’ from storefront. Retailer’s store shall be constructed in accordance with the plans, which have been approved by the
• Barricade graphics are required and must be approved by Westfield. Graphics must be • Top of the barricade should have a solid lid to contain noise, conditioned air, and weather. If the Tenant Coordinator. These plans will comply with all city, county, and state rules, ordinances and
installed within 72 hours of barricade installation. Fines of $500/day will be levied after 72 regulations relating thereto. If the store has not been constructed in accordance with said plans, the
barricade is open to the atmosphere, top edge shall be level and secured structurally to the
hours. retailer shall not be permitted to open the store for business based on the obligations under the retailer’s
building. At no time whatsoever will sandbags or water barrels be allowed.
lease. A copy of said plans must be kept on the job-site at all times during construction.
Barricade graphics must be framed with 1 x 4 painted wood, either white or black. Frames may be in • Paver flooring inside the barricade must be protected.
sections depending upon total length of barricade. Contractor to coordinate with Tenant to provide a • Doors are allowed on the barricade if the premises does not have a back door. Door must be pre-
layout submittal to Facilities Director for approval prior to installation. hung, finished, & trimmed.
• General Contractor must provide Facilities Director with a key to the premises.
02/16/2024 01/30/2024
• Barricade graphics are required and must be approved by Westfield. Graphics must be 21. Building Permit
01/19/2024 01/19/2024
Barricade graphics must be full wrap, printed scrim graphic and must include the following: installed within 72 hours of barricade installation. Fines of $500/day will be levied after 72
hours. Retailer shall apply for all permits, coordinate building department submittal and pay all associated fees.
14'-2"
• Store name and opening date on graphic returns Retailer shall apply for and obtain all approvals and permits from the local health department if required.
• Website or email address for employment opportunities Barricade graphics must be framed with 1 x 4 painted wood, either white or black. Frames may be in Building permit shall be posted in retailer’s space before any work begins (i.e., demolition, rough framing,
• Language related to open location in mall during construction if applicable, i.e. “Visit our Existing rough plumbing or electrical). A copy of the permits must be on file with the mall management office
DATE:
sections depending upon total length of barricade. Bottom and top sections of barricade to be framed.
Store near Nordstrom.” Contractor to coordinate with Tenant to provide a layout submittal to Facilities Director for approval before work starts, and a copy must be placed in clear sight within the job space.
prior to installation. 22. Security
7'-11"
16.2
•
If Tenant building Tenant canopy:
Barricade must be constructed of exterior-rated plywood that will not warp or delaminate with a
smooth grade and not textured.
Scrim description 10oz. Ultramesh, allow for a 3” bleed included outside the perimeter for mounting
purposes underneath the frame.
General Contractor shall ensure the security of premises by whatever measures it deems necessary
including the re-keying of all locksets. 10'-10"
BARRICADE SPECIFICATIONS
Revision date 07.19.2021 Revision date 07.19.2021 Revision date 07.19.2021
4'-0" 3'-11"
1'-10"
LL Initials_______________ Contractor Initials_______________ Date______________ LL Initials_______________ Contractor Initials_______________ Date______________ LL Initials_______________ Contractor Initials_______________ Date______________
18'-4"
Design Review Added Supply/Waste
DISHWASHING
4 1/4" 3'-7 3/4" 3'-0" SCALE: 1/4" = 1'-0"
Design Review Reflected Clg Plan
16'-0" x 2'-6"
4 1/4"
PROGRESS PRINTING
ALINE W/ MULLION
1'-11"
73'-6"
BAR KITCHEN Design Review Design Review DESCRIPTION:
9'-0" x 3'-0" 17'-0" x 2'-8"
COOLER
8'-2" x 8'-0" NO.
DISPLAY
4 1/4" THK BARRICADE WALL- 2 X 4 18 GA. MTL STUDS
BAR
9'-10" x 3'-0" KITCHEN HELP
17'-0" x 4'-4"
@ 16" O.C. w/ 5/8" T & G SMOOTH GRADE EXTERIOR
WATER
ROOM WASTE
WATER LINE
SUPPLY
RATED PLYWD SHTS EXTERIOR SIDE ONLY TYP. -
TOILET
33'-0"
RM #4
TOILET
RM #3
EMER. EXIT ONLY
SEE SECTIONS ABOVE. 36'-5 3/8"
TYP. 4'-0" SECTIONS
DINING ROOM
DINING ROOM #1
#2
43'-11 1/4" (V.I.F.)
43'-2 3/4"
4999 OLD ORCHARD
TOILET
PROJECT:
POINT OF RM #2
SALES TOILET
SHOPPING CENTER
DINING ACCESS
2'-8" x 14'-0" CORR.
TOILET
1 RM #1
STE A28A
ENTRY/ WAITING
A-0.2 28'-6" x 19'-3"
NEW RESTAURANT SKOKIE, IL 60077
3'-0"
7 3/4"
112'-1" 3'-0"
PROTECTIVE COVERNING OVER LINE OF CANOPY
PAVER FLOORING WITHIN
BARRICADE
9'-0" 8'-0" 9'-0"
6'-0"
3'-0" x 7'-0"
DOOR TYP. 4'-0" SECTIONS
OWNER:
4 1/4" 4 1/4"
4 1/4" 2'-0" 4 1/4" ____________
____________
82'-1 3/4" 40'-0 1/4"
ER 3
1 E BY OW N 2
SEWER LIN 122'-6 1/4" (V.I.F.) A-0.1
A-0.1 A-0.1 4 1/4" THK BARRICADE WALL- 2 X 4 18 GA. MTL STUDS SHEET NAME:
WATER
2 PROJECT TRUE @ 16" O.C. w/ 5/8" T & G SMOOTH GRADE EXTERIOR
2 SUPPLY Barricade Plan
NORTH NORTH RATED PLYWD SHTS EXTERIOR SIDE ONLY TYP. -
SEE SECTIONS ABOVE.
A-0.2
BARRICADE PLAN
SCALE: 1/4" = 1'-0"
A-0.2
PROJECT: 7438
SCALE: AS NOTED
DATE: 08/20/2023
A-0.1
20'-0"
14'-6" 1'-9" 3'-7 1/2"
13'-3 3/4" 6'-8 1/4"
4'-0"
TYP. 4 X 8
PLYWD SHTS
20'-0"
4'-0" 4'-0" 4'-0" 4'-0" 4'-0"
SCALE: 1/4" = 1'-0" 3068
SCALE: 1/4" = 1'-0"
TYP. 4 X 8
PLYWD SHTS
TYP. 4 X 8
PLYWD SHTS
EAST BARRICADE ELEVATION
NORTH BARRICADE ELEVATION
12'-0"
9'-10" 1'-5"
11'-3"
EL. + 11'-3"
EL. +/- 0'-0" BOT MTL DECK
EL. + 9'-10"
FINISHED FLOOR
FINISHED CEILING
17'-11" 2'-4"
EL. +/- 0'-0" EL. + 20'-3"
EL. + 13'-0"
TOP PARAPET
FINISHED FLOOR FINISHED CEILING
PROGRESS PRINTING
OWNER: PROJECT:
____________ NEW RESTAURANT Design Review 02/16/2024
LASZLO SIMOVIC, ARCHITECTS, L.L.C.
PROJECT: 7438
____________ Design Review Reflected Clg Plan 01/30/2024
6512 N. ARTESIAN AVE.
CHICAGO, IL. 60645-5328
SCALE: AS NOTED
01/19/2024
DATE: 08/20/2023
4999 OLD ORCHARD Design Review Added Supply/Waste EMAIL: LASZLO@LASZLOARCH.COM
Barricade Elevations SHEET NAME:
SHOPPING CENTER Design Review 01/19/2024 FAX: 773-338-2226 TEL: 773-338-2225
STE A28A NO. DESCRIPTION: DATE:
A-0.2
SKOKIE, IL 60077
14'-6" 1'-9"
13'-3 3/4"
19'-10 1/2"
13'-2"
13'-10 1/4"
SCALE: 1/4" = 1'-0" 3068
SCALE: 1/4" = 1'-0"
EXIST'G PARTIAL SOUTH ELEVATION
EXIST'G PARTIAL EAST ELEVATION
9'-10" 1'-5"
11'-3"
EL. + 11'-3"
EL. +/- 0'-0" BOT MTL DECK
EL. + 9'-10"
FINISHED FLOOR
FINISHED CEILING
0
SCALE 1/4" = 1'-0"
5
10
17'-11" 2'-4"
PARTITION CONSTR. TYPE
15
EL. +/- 0'-0" EL. + 20'-3"
EL. + 13'-0"
INCLUD'G UL # - SEE SHEET A-__
TOP PARAPET
FINISHED FLOOR FINISHED CEILING
20 FT
PROGRESS PRINTING
OWNER: PROJECT:
____________ NEW RESTAURANT Design Review 02/16/2024
LASZLO SIMOVIC, ARCHITECTS, L.L.C.
PROJECT: 7438
____________ Design Review Reflected Clg Plan 01/30/2024
6512 N. ARTESIAN AVE.
CHICAGO, IL. 60645-5328
SCALE: AS NOTED
01/19/2024
DATE: 08/20/2023
4999 OLD ORCHARD Design Review Added Supply/Waste EMAIL: LASZLO@LASZLOARCH.COM
Existing Elevations SHEET NAME:
FAX: 773-338-2226 TEL: 773-338-2225
A-4 SHOPPING CENTER Design Review 01/19/2024
STE A28A NO. DESCRIPTION: DATE:
SKOKIE, IL 60077
SPEAKERS/SECURITY CAMERAS SHOULD BE RECESSED, NOT
SURFACE MOUNTED LAWLER AVE
LASZLO SIMOVIC, ARCHITECTS, L.L.C.
RETENTION
POND
NO DIGITAL SCREENS WITHIN 5' OF WINDOW.
PARKING PARKING
BLOOMINGDALES
DECK DECK
TEL: 773-338-2225
FOREVER XXI
K10 LANDLORD MILLWORK GENERAL NOTES:
SALES AREA CEILING GENERAL NOTES:
1. ACT OR LAY-IN TILE CEILING IS PROHIBITED AT FRONT-OF-HOUSE / GOLF ROAD
DPT 1
NORDSTROM
DPT 2
MACY'S
OLD ORCHARD ROAD
1. MILLWORK AND FLOOR FIXTURES GENERAL NOTES: ALL TCM COMMENTS AND DESIGN DIRECTION REGARDING GENERAL SALES AREA AND WHERE OPENLY VISIBLE AT ANY BOH AREAS BY
6512 N. ARTESIAN AVE.
CHICAGO, IL. 60645-5328
MILLWORK (IE CASHWRAPS, SERVICE COUNTERS, WALL SHELVING SYSTEMS, PRODUCT DISPLAYS, ETC) MUST BE FULLY MEANS OF PASS-THROUGH WINDOWS. DPT3
INCORPORATED INTO SHOP DWGS AND SUBMITTED TO TCM FOR REVIEW AND APPROVAL, PRIOR TO FABRICATION.
2. CUT SHEETS FOR MERCHANDISE APPARATUS SUCH AS MANNEQUINS AND COUNTERTOP DISPLAYS MUST BE SUBMITTED FOR 2. SECURITY CAMERAS WITHIN SALES AREA MUST BE DOME-TYPE AND
REVIEW AND APPROVAL. RECESSED WITHIN CEILING. ANY EXPOSED HOUSING MUST BE
3. ALL FIXTURES TO BE UL-RATED AS AN ASSEMBLY. FLOOR FIXTURES TO BE A MAXIMUM OF 4'-0" HIGH. ALL MILLWORK & WOODS PAINTED TO MATCH CEILING FINISH COLOR, NO EXCEPTIONS. SUBMIT PARKING
DECK
TO MEET LOCAL CODE FLAMMABILITY REQUIREMENTS.
4. ALL UPHOLSTERY / FABRICS MUST MEET LOCAL CODE FLAMMABILITY REQUIREMENTS AND HAVE A COMMERCIAL-GRADE CUT SHEET FOR REVIEW AND APPROVAL. NO CLG MOUNTED
SKOKIE BOULEVARD
RATING OF 100,000 DOUBLE-RUBS OR GREATER. ALL FIXTURES & MILLWORK MUST BE PROPERLY PROTECTED AT EXPOSED SECURITY FIXTURES, MUST BE FULLY CONCEALED. NO CLG MOUNTED
EDGES AND POINTS OF IMPACT BY USE OF NECESSARY CORNER GUARDS OR SPLINES. CORNER GUARDS MUST BE OF SLIM MONITORS. NORTH
KEY PLAN
DESIGN, RECESSED FLUSH AND POWDER COATED TO MATCH ADJACENT MATERIAL FINISHES FOR A CONSISTENT LOOK.
5. ALL MILLWORK AND DISPLAY FIXTURES ALONG WALLS MUST HAVE A BUILT-IN LOOK. ANY VOID CORNERS AND BULKHEAD 3. SPRINKLERS WITHIN SALES AREA MUST BE RECESSED AND
SHALL BE FURRED OUT TO AVOID DEAD / HOLLOW AREAS AND CEILINGS DROPPED TO CREATE SOFFITS ABOVE FIXTURE CAPPED.
FINISHES IN ORDER TO RECESS MILLWORK AND ACHIEVE A BUILT-IN LOOK. ABUNDANT USE OF SLAT WALL IS NOT PERMITTED, AS SPRINKLER CAPS MUST MATCH COLOR OF ADJACENT CEILING FINISH,
EMAIL: LASZLO@LASZLOARCH.COM
THIS CREATES VISUAL CLUTTER AND OVERPOPULATION OF MERCHANDISE.
NO EXCEPTIONS. *CAPS ARE NOT ALLOWED TO BE PAINTED IN-FIELD ROOF LEVEL SCALE: N.T.S.
6. CLUTTER AND OVER-MERCHANDISING IS NOT PERMITTED WITHIN SALES AREA AND IS AT TCM DISCRETION, PER DESIGN BUILDING ABOVE MAGGIANO'S BSMT SLAB ON GRADE
CRITERIA. AND MUST BE SUPPLIED COLORED BY MANUFACTURER, PER CODE.
7. ALL POWER SOURCES & ELECTRICAL WIRING MUST BE FULLY CONCEALED FROM CUSTOMER SIGHTLINES; NO EXPOSED 4. HVAC DIFFISUSERS AND RETURNS WITHIN SALES AREA MUST BE
FAX: 773-338-2226
POWER CORDS WILL BE PERMITTED TO RUN BETWEEN CASHIER STAND TO MILLWORK DIRECTLY BEHIND TO CAUSE TRIP
HAZARD; NO MATS WILL BE PERMITTED TO CONCEAL SUCH CONDITIONS - TYP NO OPEN, UNDER-COUNTER STORAGE ALLOWED ARCHITECTURAL LINEAR OR SINGLE PLATE (SEE OMNI BY TITUS HVAC
WITHIN SALES AREA, INCLUDING CASHWRAP. OR SIMILAR). DIFFUSERS AND RETURN AIR GRILLES MUST MATCH
8. ALL STORAGE SHELVING MUST HAVE HINGED DOORS, WITH RECESSED / FLUSH LOCKS AND PULL HANDLES. COLOR OF ADJACENT CEILING FINISH, NO EXCEPTIONS. SUBMIT CUT
9. CONTINUOUS LED LIGHTING WITHIN FIXTURES MUST BE INSTALLED IN A RECESSED MANNER, WITHIN COVE OR OTHERWISE
19'-10"
NOTED - AND A DIFFUSER MUST BE PROVIDED IN ORDER TO AVOID "HOT" OR "SHADOW" SPOTS REFLECTED ONTO MERCHANDISE. SHEETS AND SPECIFY WITHIN MECHANICAL DRAWINGS FOR REVIEW
LED STRIP LIGHTING MUST BE INSTALLED IN A MANNER AS TO AVOID DIRECT SIGHTLINES OF THE "DOT PATTERN", WHICH AND APPROVAL. 3'-4" 5'-8"
TYPICALLY SHOWS BY REFLECTION WITH USE OF GLASS AND MIRRORS. CONFIRM MILLWORK COMPONENTS AND BASE ARE 5. EMERGENCY LIGHTS MUST BE THROUGH SPECIFIED
HIGHLY DURABLE AND IMPACT-RESISTANT TO ASSURE MINIMAL DAMAGE.
10. BASE OF FIXTURES TO BE METAL SUCH AS STAINLESS STEEL OR HEAVY GAUGE ALUMINUM AND MUST BE CONTINUOUS AND ARCHITECTURAL LIGHTING BY USING E-INVERTER (OR SIMILAR). NO
BENT TO WRAP AT ALL EXPOSED EDGES, WITH MINIMAL SEAMS THAT ARE OUT OF CUSTOMER SIGHTLINES. RECESSED BASE BUG-EYES ALLOWED. EMERGENCY EXIT SIGNS SHALL BE EDGE-LIT
DETAIL IS PREFERRED.
11. COUNTERTOPS TO BE SOLID SURFACE OR OTHER DURABLE MATERIAL AND MUST HAVE EASED, BEVELED OR RADIUS EDGES.
12. PLASTIC LAMINATES AND UNPROTECTED WOOD VENEERS USED FOR FIXTURE FINISHES ARE NOT ALLOWED.
BLADE TYPE WITH RECESSED BALLAST (WALL OR CEILING MOUNT).
SUBMIT CUT SHEET FOR REVIEW AND APPROVAL.
1'-6" 6'-1"
6. ALL ACCESS PANELS AND HARDWARE MUST BE FINISHED TO MATCH
3'-4"
13. ANY VISIBLE PRE-DRILLED HOLES IN MILLWORK, NOT USED FOR SHELVING OR MERCHANDISING APPARATUS IS NOT ALLOWED,
TYP. STANDARDS AND MERCHANDISING HARDWARE MUST BE CONSISTENT TO MATCH WITH OVERALL MILLWORK FINISHES FOR ADJACENT CEILING COLOR FINISHES, NO EXCEPTIONS. DRYWALL
A CONSISTENT LOOK. ALL HARDWARE, FASTENERS, UTINSIL HOLDERS AND COUNTERTOP MERCHANDISE APPARATUS THAT IS
ACCESS PANELS (SUCH AS MOONLIGHT MOLDS) ARE STRONGLY 1'-6"
EXPOSED AND WITHIN CUSTOMER SIGHTLINES MUST BE COUNTERSUNK, FLUSH AND PAINTED TO MATCH ADJACENT SURFACE
FINISHES FOR AN OVERALL CLEAN APPEARANCE. PREFERRED OVER METAL HINGED DOORS. CONSULT GC WHERE BEST
14. FLOOR FIXTURES ON ROLLING CASTERS MUST BE ABLE TO LOCK-IN-PLACE DURING OPERATIONAL HOURS. CASTERS AND APPLICABLE. ACCESS PANELS SHOULD BE LOCATED AWAY FROM
ATTACHMENT HARDWARE MUST BE RECESSED FROM MILLWORK FACE AND A "SKIRT" BASE MUST BE INCORPORATED INTO
MILLWORK DESIGN TO CONCEAL CASTERS. FOCAL POINT AREAS.
15. SNEEZGUARDS AND/OR CLEAR GLASS SHROUDS MUST BE OF LOW-IRON [PPG STARPHIRE OR EQUIV.] AND MUST BE 7. IF OPEN CLG THEN FIRST 10'+/- MUST BE GYP BOARD WITH
UV-BONDED / FUSED AT JOINTS. RECESSED FIXTURES.
16. SILICONE JOINTS ARE STRICTLY PROHIBITED, NO EXCEPTIONS. TEMPORARY & PROMOTIONAL DISPLAY FIXTURES AND NEW
8. TRACK LIGHTS MAY NOT BE SURFACE MOUNTED ON SHEET ROCK.
10'-3"
MILLWORK OR MERCHANDISE DISPLAY SYSTEMS NOT PRESENTED WILL NOT BE PERMITTED WITHOUT FORMAL REVIEW AND
APPROVAL. CLGS TRACK LIGHTS NEED TO BE FULLY RECESSED EITHER 1.IN 38'-2"
10'-3"
17. P.O.S. EQUIPMENT MUST BE FULLY INTEGRATED AND CONCEALED WITHIN CASHWRAP MILLWORK AND ANY SHROUDS MUST RECESSED NICHE OR 2. A SPEC WITH FULLY RECESSED TRACK
BE PROVIDED FOR COUNTERTROP MONITORS.
18. ALL WIRES AND DOCK STATION MUST NOT BE VISIBLE TO CUSTOMERS WITHIN SALES AREA. P.O.S. AREA MUST BE CLEAN AND (TAPED INTO CLG) IS SUBMITTED TO & APPROVED BY URW.
CLUTTER-FREE AND CONFIGURATION MUST BE INCORPORATED INTO OVERALL STORE'S DESIGN. P.O.S. MUST COMPLY WITH ALL 9. TRANSFER GRILLS ARE REQUIRED FOR SMOKE EVAC IN CERTAIN
K10.7 ACCESSBILITY REQUIREMENTS. AREAS OF THE CENTER (SEE CRITERIA). GRILLS SHOULD BE LINEAR
02/16/2024 01/30/2024
19. ALL IMPLUSE FIXTURES AT POS MUST BE INTEGRATED WITH THE OVERAL CONCEPT.
01/19/2024 01/19/2024
14'-3 7/8"
20. ENSURE FIXTURES AND CASHWRAP ARE ADA COMPLIANT AND CODE COMPLIANT AS REQ'D BY ALL LOCAL CODES AND AND PAINTED TO MATCH THE WALLS. 9'-0" 10'-10 1/8" 10'-8 7/8" 5" 7'-2"
Tenant must show
14'-2"
JURISDICTIONS
elevation at parapet above
DATE:
maggiano's
10'-10"
DISHWASHING 1'-10"
1'-10" 18'-4"
Design Review Added Supply/Waste
3'-0"
Tenant must show 2'-0" 11'-0" 2'-6" 18'-3" 1'-0" 6'-0" 1'-0" 19'-0" 4'-0" 8'-6 1/2" 5"
Design Review Reflected Clg Plan
16'-0" x 2'-6"
demolition and construction
2'-5 3/4"
plans including existing pier,
3'-10 1/2"
3'-0"
PROGRESS PRINTING
storefront, awning
16'-0" 4'-0" 1'-1"
2'-6"
73'-6" 5'-7"
8 7/8"
DESCRIPTION:
5"
Design Review Design Review
5"
K11 20'-0" 2'-0" 2'-0" 3'-0" 2'-6" 5" 3'-0" 8'-2"
3'-0"
4'-6 1/8"
BAR KITCHEN 2'-8"
9'-0" x 3'-0" 17'-0" x 2'-8"
8'-11 1/2" 3'-0" 18'-1" 17'-1" COOLER 8'-0"
8'-2" x 8'-0" NO.
3'-0" 3'-0"
DISPLAY
4'-6 1/4"
8'-6 1/4"
5" 11'-2"
5'-0" BAR
KITCHEN HELP
11'-1 1/2"
9'-10" x 3'-0"
11'-0" 2'-1" 5" 45'-3" 4'-0" 3'-0" 17'-0" x 4'-4" 3'-0"
WATER
3'-0" ROOM WASTE 2'-6"
WATER LINE
SUPPLY
3'-0"
K11.4
5"
3'-6"
1'-6"
TOILET MIN. 5'-0"
33'-0"
6" 3'-0" 6" 2'-6" 9'-10" 17'-8 1/2" 3'-0"
RM #4
TOILET
RM #3 5'-0"
EMER. EXIT ONLY
36'-5 3/8"
27'-0 1/2" 3'-0" 3'-0" 2'-6"
2'-6"
5'-0" 30'-1 1/2" 6'-0 1/4"
28'-1 1/2"
DINING ROOM
33'-0"
18'-0 3/4"
5"
#1 1'-6"
DINING ROOM
#2
13'-4 1/2"
4'-9"
1'-6"
3'-10 5/8"
4999 OLD ORCHARD
TOILET
21'-1 1/2"
PROJECT:
POINT OF RM #2
SALES TOILET
20'-0"
SHOPPING CENTER
DINING ACCESS
2'-8" x 14'-0"
5" CORR.
TOILET
RM #1
STE A28A
ENTRY/ WAITING
8'-7 1/8"
13'-0" 4'-9"
16'-7 1/2"
5'-0"
28'-6" x 19'-3"
NEW RESTAURANT SKOKIE, IL 60077
9" 5"
2'-6" 5" 5'-9" 5" 5'-0"
4'-9"
3'-9 1/2"
2'-0"
6'-1 1/4"
K12
2'-6"
1'-9"
112'-1"
2'-0" 11'-0" 2'-6" 45'-3" 4'-0" 47'-1 1/2" 5"
3'-0"
5'-0" 5'-0" 7'-8" 5'-0" 3'-6" 5'-0" 3'-6" 5'-0" 3'-6" 5'-0" 3'-6" 5'-0" 12'-0" 5'-0" 3'-6" 5'-0" 3'-4" 6'-4" 3'-4" 5'-0" 3'-6" 5'-0" 3'-2 1/2"
If tenant uses patio at all then it
must comply with guidelines.
Tenant must show it on Final LOCATION OF TEMPOARARY
2'-6" VESTIBULE (COLD MONTHS ONLY)
Drawing Submittal. It must 2'-6"
seating & include railings,
planters, lighting and optional
heating.
See attached guidelines that OWNER:
9'-6 7/8"
are an addendum to the criteria.
____________
1'-9" 12'-6" 20'-0" 20'-0" 10'-0" 16'-10" 13'-2" 30'-0"
111'-10 1/2" 30'-0" to KF
ER
____________
XX KA SEWER LIN
E BY OW N KB KB.7 KC KC.6 KD We cannot approve a full
height structure outside SHEET NAME:
lease line including a WATER
temporary vestibule. If it's SUPPLY New Floor Plan
PROJECT TRUE needed then it must be
NORTH NORTH
NEW 1ST FLOOR PLAN
inside space.
We recommend a curtain PROJECT: 7438
SCALE: 1/4" = 1'-0"
3,855 SF LEASED SPACE 2/1/24
situation inside door.
PARTITION LEGEND SCALE: AS NOTED
WALL TO REMAIN DATE: 08/20/2023
WALL TO BE REMOVED
WALL FINISH TO BE REMOVED
STUDS TO REMAIN
A-5
WALL TO BE CONSTRUCTED
PARTITION CONSTR. TYPE
INCLUD'G UL # - SEE SHEET A-__
0 5 10 15 20 FT
SCALE 1/4" = 1'-0"
LAWLER AVE
LASZLO SIMOVIC, ARCHITECTS, L.L.C.
RETENTION
POND
PARKING PARKING
BLOOMINGDALES
DECK DECK
TEL: 773-338-2225
FOREVER XXI
K10 OLD ORCHARD ROAD
DPT 1
NORDSTROM
DPT 2
GOLF ROAD
MACY'S
6512 N. ARTESIAN AVE.
CHICAGO, IL. 60645-5328
DPT3
PARKING
DECK
SKOKIE BOULEVARD
NORTH
KEY PLAN
EMAIL: LASZLO@LASZLOARCH.COM
SCALE: N.T.S.
FAX: 773-338-2226
EXIST'G RUBBER
ROOF
K10.7
02/16/2024 01/30/2024 01/19/2024 01/19/2024 DATE:
Tenant must show elevation at parapet above
maggiano's
Design Review Reflected Clg Plan Design Review Added Supply/Waste
PROGRESS PRINTING
Design Review Design Review DESCRIPTION:
K11
NEW EXTRUDED ALUMINUM
COPING, COLOR TO MATCH
EXTERIOR FINISH, TYP.
NO.
EXIST'G 2ND FLOOR
(N.I.C.)
K11.4
EXIST'G RUBBER
ROOF
NEW RUBBER
ROOF TO
MATCH EXIST'G
4999 OLD ORCHARD
PROJECT:
SHOPPING CENTER
STE A28A
NEW RESTAURANT SKOKIE, IL 60077
NEW EXTRUDED ALUMINUM
COPING, COLOR TO MATCH
EXTERIOR FINISH, TYP.
K12
OWNER:
____________
____________
XX KA KB KB.7 KC KC.6 KD SHEET NAME:
New Roof Plan
PROJECT TRUE
NORTH NORTH
NEW ROOF PLAN PROJECT: 7438
SCALE: 1/4" = 1'-0"
3,855 SF LEASED SPACE PARTITION LEGEND SCALE: AS NOTED
WALL TO REMAIN DATE: 08/20/2023
WALL TO BE REMOVED
WALL FINISH TO BE REMOVED
STUDS TO REMAIN
A-6
WALL TO BE CONSTRUCTED
PARTITION CONSTR. TYPE
INCLUD'G UL # - SEE SHEET A-__
0 5 10 15 20 FT
SCALE 1/4" = 1'-0"
CUPITOL
TENANT BUILD OUT
NEW RESTAURANT TO REPLACE
EXISTING RESTAURANT
4999 OLD ORCHARD SHOPPING
CENTER,SUITE A28
SKOKIE, IL 60077 PROJECT TO COMPLY WITH:
INDEX OF DRAWINGS:
T-1: COVER SHEET
2021 INTERNATIONAL BUILDING CODE WITH LOCAL AMENDMENTS
TENANT 2014 STATE OF ILLINOIS PLUMBING CODE WITH LOCAL AMENDMENTS
2020 NATIONAL ELECRIC CODE WITH LOCAL AMENDMENTS
2021 INTERNATIONAL MECHANICAL CODE WITH LOCAL AMENDMENTS ARCHITECTURAL:
A-0: BARRICADE PLAN
ALEXIOS GEORGES 2021 INTERNATIONAL FUEL GAS CODE WITH LOCAL AMENDMENTS
2018 INTERNATIONAL ENERGY CONSERVATION CODE WITH ILLINOIS AMENDMENTS
2010 ADA DESIGN GUIDELINES
A-0.1
A-6:
BARRICADE ELEVATIONS
NEW 1ST FLOOR PLAN
4999 OLD ORCHARD SHOPPING CENTER 2018 ILLINOIS ACCESSIBILITY CODE
2021 INTERNATIONAL FIRE CODE WITH LOCAL AMENDMENTS
A-7:
A-8:
NEW ROOF PLAN
NEW ELEVATIONS
SUITE A28 2021 LIFE SAFETY CODE A-13: ENLARGED FRONT ELEVATION
SKOKIE, IL 60077
LANDLORD
WESTFIELD OLD ORCHARD OLD ORCHARD ROAD
CONTACT: JINYOUNG JANG
PH: (872)227-4067
EMAIL: JINYOUNF.JANG@URW.COM
ARCHITECT FOREVER XXI
LASZLO SIMOVIC
LASZLO SIMOVIC ARCHITECTS, LLC BLOOMINGDALES
6512 N ARTESIAN AVE
CHICAGO, IL 60645
DPT3
PARKING PARKING
DECK DECK
LAWLER AVE
SKOKIE BOULEVARD
DPT 2
MACY'S
"CUPITOL"
AREA OF WORK
AREA OF WORK
PARKING
DECK
RETENTION
I CERTIFY THAT I AM THE REGISTERED ENERGY PROFESSIONAL FOR THIS PROJECT. I ALSO CERTIFY THAT TO THE BEST OF DPT 1
MY PROFESSIONAL KNOWLEDGE AND BELIEF THE ATTACHED PLANS FOR: 4999 OLD ORCHARD SHOPPING CENTER, SUITE NORDSTROM
POND
A28A., SKOKIE, IL. 60077 DOES COMPLY WITH THE REQUIREMENTS OF CHAPTER 18-13, ENERGY CONSERVATION, OF THE
MUNICIPAL CODE OF SKOKIE AS OF APRIL 22, 2009.
SIGNED_____________________________________________DATE: MARCH 27, 2024
(ARCHITECT)
ILLINOIS LICENSE NUMBER: 001-012275
THESE DRAWINGS ARE PREPARED UNDER MY SUPERVISION AND TO THE
BEST OF MY KNOWLEDGE & BELIEF, ARE IN COMPLIANCE WITH THE VILLAGE
OF SKOKIE BUILDING CODE.
GOLF ROAD
EXPIRES 11/30/24
N PROFESSIONAL DESIGN FIRM LICENSE NO. 184.006791 EXPIRES 4/30/2025
SITE PLAN N
SCALE: N.T.S.
C LASZLO SIMOVIC, ARCHITECTS 2024
KEY PLAN
SCALE: 1" = 200'
CUPITOL - OLD ORCHARD
PRELIMINARY DESIGN
SUITE 828A
FEB 23, 2024
MARCH 23, 2024
C LASZLO SIMOVIC ARCHITECTS, LLC
EXTERIOR SAMPLE BOARD ONLY
CANOPY PENDANT LIGHTING EXTERIOR WALL LIGHTING
MODEL # MODEL #
WINDOWS & DOOR COMBINATIONS WINDOWS & DOOR COMBINATIONS
ALUMI SMARTIA 567 URBAN ALUMI SMARTIA 567 URBAN
SAMPLE POT W/ PLANT EXTERIOR CHAIRS & TABLES
MODEL # MODEL #
CUPITOL - OLD ORCHARD
PRELIMINARY DESIGN
SUITE 828A
FEB 23, 2024
MARCH 23, 2024
SAMPLE CLADDING EXTERIOR CLADDING NOTE: METAL CLADDING AT CANOPY TOC MACH
ALUMNI SMARTIA 567 URBAN LASZLO SIMOVIC ARCHITECTS, LLC
BOOST STONE - TARMAC 120X 278
LASZLO SIMOVIC, ARCHITECTS, L.L.C.
TEL: 773-338-2225
6512 N. ARTESIAN AVE.
CHICAGO, IL. 60645-5328
MAGGIANO'S BSMT SLAB ON GRADE EXIST'G EXT.
ROOF LEVEL BUILDING ABOVE WALL
1/4"/ FT PITCH
1/4"/ FT PITCH 1/4"/ FT PITCH
EMAIL: LASZLO@LASZLOARCH.COM
• Barricade to be framed with 1”x4” wood, painted either black or white depending upon graphic. Barricade graphics must be full wrap, printed scrim graphic and must include the following:
Color to be approved by Westfield Tenant Coordination.
2'-0" 2'-0"
15. No Smoking Policy • Store name and opening date on graphic returns
• All exterior wood surfaces must be fully primed and painted on all exposed surfaces including the
• Website or email address for employment opportunities
Smoking is prohibited on the premises, common areas or base building construction site. edges and backs with good quality primer/paint designed for wood surfaces to ensure good
• Language related to open location in mall during construction if applicable, i.e. “Visit our Existing
adhesion under exterior weather conditions. Paint Specifications: Glidden, exterior latex, semi-
18 GA. MTL
7'-7" (V.I.F.)
FAX: 773-338-2226
Store near Nordstrom.”
16. Storefront Barricade Policy •
gloss finish, Fauna. ID 10YY 18/074.
All plywood joints need to be screwed down to framing to eliminate bowing and warping. EXIST'G 18 GA. MTL EXIST'G 18 GA. MTL FRAM'G 16" O.C.
At Westfield’s option, barricades will be constructed by Westfield at General Contractor’s expense. All
•
•
Install wind bracing as necessary to stabilize the barricade.
17. Door Name & Address PARAPET FRAM'G 16" O.C. PARAPET FRAM'G 16" O.C.
Barricade must be full height. In order to accommodate installation of Tenant canopy, barricade
WALL WALL
V.I.F. V.I.F.
questions regarding barricade graphics requirements must be submitted to Tenant Coordinator before should be constructed in 2 sections, height of each section to be determined by height of Tenant General Contractor needs to have store name and address painted on back door. The address on the
installing the barricade. front door area should be applied with the proper address sticker. Exact location must be approved by the
canopy.
22'-0". (V.I.F.)
Barricades requirements are as follows: o Example: Barricade is 20’ high. If Tenant canopy is at 12’, lower section of barricade Facilities Director.
ROOF
22'-0". (V.I.F.) 22'-0". (V.I.F.)
16.1 If underneath Landlord canopy: would be up to 12’ high (bottom of Tenant canopy AFF), upper section to be 8’. Full • 1 inch letters for metal rear doors
wrap graphic required on lower section; upper would eventually be removed so graphic • 4 inch height white block letters, Arial font, installed on the inside lower right side of the storefront,
should be different than that of lower section. Refer to illustration below. 2½” from bottom of glazing to bottom of letters. Furthest glazing panel on the right, right justified.
• Barricade must be constructed of exterior-rated plywood that will not warp or delaminate with a
smooth grade and not textured.
Not on doors, glazing panel only
BLOCK'G
• BLOCK'G BLOCK'G AS REQ'D
Barricade to be framed with 1”x4” wood, painted either black or white depending upon graphic.
Color to be approved by Westfield Tenant Coordination. 18. Quality of Workmanship AS REQ'D 3'-0" AS REQ'D
• All exterior wood surfaces must be fully primed and painted on all exposed surfaces including the
ROOF
1'-6" 6'-1"
edges and backs with good quality primer/paint designed for wood surfaces to ensure good General Contractor’s work shall be performed in a through, first class and workmanlike manner and shall
adhesion under exterior weather conditions. Paint Specifications: Glidden, exterior latex, semi- be in good usable condition at the date of completion thereof. If in Westfield’s judgment, the General
gloss finish, Fauna. ID 10YY 18/074. Contractor’s work is not completed in a first class and workmanlike manner, Tenant will not be allowed to
• All plywood joints need to be screwed down to framing to eliminate bowing and warping. open until said discrepancies are corrected.
• Install wind bracing as necessary to stabilize the barricade.
3'-0"
3'-4"
• Barricade must be full height, to bottom of canopy or top of parapet wall.=
19. Supervision
•
•
Barricade to be 5’ from storefront.
EXIST'G BLDG
Top of the barricade should have a solid lid to contain noise, conditioned air, and weather. If the
barricade is open to the atmosphere, top edge shall be level and secured structurally to the
General Contractor shall provide a full-time supervisor on site at all times when construction is being
performed in retailer’s space. Failure to comply will result in immediate work stoppage until such time as EXIST'G BLDG EXIST'G EXT. EXIST'G BLDG
building. At no time whatsoever will sandbags or water barrels be allowed. said supervisor is present.
WALL
•
•
Paver flooring inside the barricade must be protected.
Doors are allowed on the barricade if the premises does not have a back door. Door must be pre- EXIST'G EXT. PAVER
•
hung, finished, & trimmed.
General Contractor must provide Facilities Director with a key to the premises. • Barricade to be 5’ from storefront.
20. Approved Design
WALL PAVER PAVER PROTECTION
Retailer’s store shall be constructed in accordance with the plans, which have been approved by the
• Barricade graphics are required and must be approved by Westfield. Graphics must be
installed within 72 hours of barricade installation. Fines of $500/day will be levied after 72
• Top of the barricade should have a solid lid to contain noise, conditioned air, and weather. If the Tenant Coordinator. These plans will comply with all city, county, and state rules, ordinances and
regulations relating thereto. If the store has not been constructed in accordance with said plans, the
PROTECTION PROTECTION
barricade is open to the atmosphere, top edge shall be level and secured structurally to the
hours. retailer shall not be permitted to open the store for business based on the obligations under the retailer’s
building. At no time whatsoever will sandbags or water barrels be allowed.
lease. A copy of said plans must be kept on the job-site at all times during construction.
Barricade graphics must be framed with 1 x 4 painted wood, either white or black. Frames may be in • Paver flooring inside the barricade must be protected.
sections depending upon total length of barricade. Contractor to coordinate with Tenant to provide a • Doors are allowed on the barricade if the premises does not have a back door. Door must be pre-
10'-3"
layout submittal to Facilities Director for approval prior to installation. hung, finished, & trimmed.
3 TYP. SECT.
• General Contractor must provide Facilities Director with a key to the premises.
1 TYP. SECT. 2 TYP. SECT.
• Barricade graphics are required and must be approved by Westfield. Graphics must be 21. Building Permit
Barricade graphics must be full wrap, printed scrim graphic and must include the following: installed within 72 hours of barricade installation. Fines of $500/day will be levied after 72
hours. Retailer shall apply for all permits, coordinate building department submittal and pay all associated fees.
• Store name and opening date on graphic returns Retailer shall apply for and obtain all approvals and permits from the local health department if required.
• Website or email address for employment opportunities Barricade graphics must be framed with 1 x 4 painted wood, either white or black. Frames may be in Building permit shall be posted in retailer’s space before any work begins (i.e., demolition, rough framing,
• rough plumbing or electrical). A copy of the permits must be on file with the mall management office
Language related to open location in mall during construction if applicable, i.e. “Visit our Existing
Store near Nordstrom.”
sections depending upon total length of barricade. Bottom and top sections of barricade to be framed.
Contractor to coordinate with Tenant to provide a layout submittal to Facilities Director for approval before work starts, and a copy must be placed in clear sight within the job space. SCALE: 1" = 1'-0"
prior to installation. 22. Security SCALE: 1" = 1'-0" SCALE: 1" = 1'-0"
16.2 If Tenant building Tenant canopy:
03/21/2024
Scrim description 10oz. Ultramesh, allow for a 3” bleed included outside the perimeter for mounting General Contractor shall ensure the security of premises by whatever measures it deems necessary
• Barricade must be constructed of exterior-rated plywood that will not warp or delaminate with a purposes underneath the frame. including the re-keying of all locksets.
7'-11"
14'-2"
smooth grade and not textured.
Revision date 07.19.2021 Revision date 07.19.2021 Revision date 07.19.2021
4'-0" 3'-11"
DATE:
LL Initials_______________ Contractor Initials_______________ Date______________ LL Initials_______________ Contractor Initials_______________ Date______________ LL Initials_______________ Contractor Initials_______________ Date______________
4 1/4" 3'-7 3/4" 3'-0" 10'-10"
4 1/4" BARRICADE SPECIFICATIONS
SCALE: 1/4" = 1'-0"
DISHWASHING 1'-10" 18'-4"
GREASE
1 TYP. SECT.
INTERCEPTOR
PROGRESS PRINTING
HWH
ALIGN W/ MULLION EXISTING
73'-6" EXISTING ROOF DRAIN BLACK IRON
EXHAUST
SCALE: 1" = 1'-0"
OPEN OFFICE
Design Review DESCRIPTION:
BAR
KITCHEN
DISPLAY
COOLER
8'-2" x 8'-0"
NO.
4 1/4" THK BARRICADE WALL- 2 X 4 18 GA. MTL STUDS
BAR
KITCHEN HELP
@ 16" O.C. w/ 5/8" T & G SMOOTH GRADE EXTERIOR
DINING ROOM TOILET
#2 RM #4
HC TOILET
RATED PLYWD SHTS EXTERIOR SIDE ONLY TYP. -
RM #3
33'-0"
DISPLAY
CASE
EMER. EXIT ONLY
C
L
SEE SECTIONS ABOVE.
POINT OF
TYP. 4'-0" SECTIONS
C
L SALES
DINING ROOM
36'-5 3/8"
#1
46'-3 3/4" (V.I.F.)
TOILET
45'-7 1/4"
RM #2
OLD ORCHARD MALL
TOILET
RM #1
PROJECT:
TOILET
CORR.
SKOKIE, IL
1
A-0.2 DINING 2" WATER
NEW RESTAURANT
WATER
ACCESS
MAIN
RM
ENTRY/ WAITING
WASTE LINE
3'-0"
7 3/4"
112'-1" 3'-0"
OUTDOOR PATIO
PROTECTIVE COVERNING OVER LINE OF CANOPY
PAVER FLOORING WITHIN ENTRY
9'-0" 9'-0"
BARRICADE
8'-0"
6'-0"
3'-0" x 7'-0"
DOOR TYP. 4'-0" SECTIONS
OWNER:
4 1/4" 4 1/4"
4 1/4" 2'-0" 4 1/4" ____________
____________
82'-1 3/4" 40'-0 1/4"
3
1 2 122'-6 1/4" (V.I.F.) A-0.1 SHEET NAME:
A-0.1 A-0.1 4 1/4" THK BARRICADE WALL- 2 X 4 18 GA. MTL STUDS WATER
2 PROJECT TRUE @ 16" O.C. w/ 5/8" T & G SMOOTH GRADE EXTERIOR
2 SUPPLY Barricade Plan
NORTH NORTH RATED PLYWD SHTS EXTERIOR SIDE ONLY TYP. -
SEE SECTIONS ABOVE.
A-0.2
BARRICADE PLAN
SCALE: 1/4" = 1'-0"
A-0.2
PROJECT: 7438
SCALE: AS NOTED
DATE: 08/20/2023
A-0.1
20'-0"
14'-6" 1'-9" 3'-7 1/2"
13'-3 3/4" 6'-8 1/4"
4'-0"
TYP. 4 X 8
PLYWD SHTS
20'-0"
4'-0" 4'-0" 4'-0" 4'-0" 4'-0"
SCALE: 1/4" = 1'-0" 3068
SCALE: 1/4" = 1'-0"
TYP. 4 X 8
PLYWD SHTS
TYP. 4 X 8
PLYWD SHTS
EAST BARRICADE ELEVATION
NORTH BARRICADE ELEVATION
12'-0"
9'-10" 1'-5"
11'-3"
EL. + 11'-3"
EL. +/- 0'-0" BOT MTL DECK
EL. + 9'-10"
FINISHED FLOOR
FINISHED CEILING
17'-11" 2'-4"
EL. +/- 0'-0" EL. + 20'-3"
EL. + 13'-0"
TOP PARAPET
FINISHED FLOOR FINISHED CEILING
PROGRESS PRINTING
OWNER: PROJECT:
ALEXIOS GEORGES NEW RESTAURANT LASZLO SIMOVIC, ARCHITECTS, L.L.C.
PROJECT: 7438
4999 OL ORCHARD 6512 N. ARTESIAN AVE.
SHOPPING CTR, SUITE A28 CHICAGO, IL. 60645-5328
DATE: 08/20/2023 SCALE: AS NOTED
Barricade Elevations SHEET NAME:
SKOKIE, IL 60077 4999 OL ORCHARD EMAIL: LASZLO@LASZLOARCH.COM
SHOPPING CTR, SUITE A28 Design Review 03/21/2024 FAX: 773-338-2226 TEL: 773-338-2225
SKOKIE, IL 60077
A-0.1
NO. DESCRIPTION: DATE:
LASZLO SIMOVIC, ARCHITECTS, L.L.C.
TEL: 773-338-2225
K10
6512 N. ARTESIAN AVE.
CHICAGO, IL. 60645-5328
MAGGIANO'S BSMT SLAB ON GRADE
ROOF LEVEL BUILDING ABOVE
EMAIL: LASZLO@LASZLOARCH.COM
FAX: 773-338-2226
1'-6" 6'-1"
3'-4"
1
ALIGN
A-13
10'-3"
K10.7
14'-2" 03/21/2024
DATE:
10'-10"
DISHWASHING 1'-10" 18'-4"
GREASE
INTERCEPTOR
HWH
PROGRESS PRINTING
EXISTING
73'-6" EXISTING ROOF DRAIN BLACK IRON
EXHAUST OPEN OFFICE
Design Review DESCRIPTION:
VELVET BANQUET #1 VELVET BANQUET #2
K11
BAR
KITCHEN
DISPLAY
COOLER
8'-2" x 8'-0"
NO.
BAR
KITCHEN HELP
DINING ROOM TOILET
#2 RM #4
K11.4 2 HC TOILET
RM #3
A-12
33'-0"
DISPLAY 3
CASE
EMER. EXIT ONLY
C
L
LEATHER BANQUET #3 LEATHER BANQUET #4
POINT OF
C
L SALES
DINING ROOM
36'-5 3/8"
#1
TOILET
RM #2
1
OLD ORCHARD MALL
A-12 TOILET
RM #1
PROJECT:
rendering TOILET
view #2
CORR.
rend
view e#ring
1
SKOKIE, IL
DINING
rendering
view #3 2" WATER
WATER
NEW RESTAURANT
MAIN
ACCESS RM
F.D.
ENTRY/ WAITING
WASTE LINE
K12
L11.9 112'-1" ALIGN
OUTDOOR PATIO
NEW COLUMNS AND COLUMN LINE
PER STRUCTURAL DRAWINGS
ENTRY
NEW WATER LIN NEW SEWER LINE
BY OWNER
2 1 BY OWNER -
ROUTED UNDER
1
A-10 A-11 BOTTOMOF A-10
FOOTING
OWNER:
2 ____________
A-11
____________
XX KA KB KB.7 KC KC.6 KD SHEET NAME:
WATER
SUPPLY New Floor Plan
PROJECT TRUE
NORTH NORTH
NEW 1ST FLOOR PLAN PROJECT: 7438
SCALE: 1/4" = 1'-0"
3,855 SF LEASED SPACE SCALE: AS NOTED
DATE: 08/20/2023
A-6
LASZLO SIMOVIC, ARCHITECTS, L.L.C.
TEL: 773-338-2225
K10
6512 N. ARTESIAN AVE.
CHICAGO, IL. 60645-5328
EMAIL: LASZLO@LASZLOARCH.COM
FAX: 773-338-2226
EXIST'G RUBBER
ROOF
2
A-13
K10.7
03/21/2024
DATE:
NOTE: PROVIDE OPENING
AT BOTTOM OF RETURN
WALL ALIGNING W/ TOP'
OF LOWER PARAPET
WALL TO ALLOW EXIST'G
DRAINAGE TO REMAIN.
NOTE: ALIGN TOP OF RETURN
WALL WITH TOP OF PARAPET
WALL EXISTING ROOF DRAIN
PROGRESS PRINTING
EXISTING
BLACK IRON
EXHAUST
Design Review DESCRIPTION:
K11
NEW EXTRUDED ALUMINUM NO.
COPING, COLOR TO MATCH
EXTERIOR FINISH, TYP.
EXIST'G 2ND FLOOR
(N.I.C.)
K11.4 2
A-12
EXIST'G RUBBER
ROOF
REPAIR / REPLACE AS
NEW RUBBER REQUIRED
ROOF TO
MATCH EXIST'G
4999 OL ORCHARD
1
A-12
PROJECT:
SHOPPING CTR, SUITE A28
NEW RESTAURANT SKOKIE, IL 60077
NEW EXTRUDED ALUMINUM
COPING, COLOR TO MATCH
EXTERIOR FINISH, TYP.
K12
OWNER:
2 1 1 ALEXIOS GEORGES
A-10 A-11 A-10
4999 OL ORCHARD
SHOPPING CTR, SUITE A28
SKOKIE, IL 60077
2
A-11
XX KA KB KB.7 KC KC.6 KD SHEET NAME:
KE
New Roof Plan
PROJECT TRUE
NORTH NORTH
NEW ROOF PLAN PROJECT: 7438
SCALE: 1/4" = 1'-0"
3,855 SF LEASED SPACE PARTITION LEGEND SCALE: AS NOTED
WALL TO REMAIN DATE: 08/20/2023
WALL TO BE REMOVED
WALL FINISH TO BE REMOVED
STUDS TO REMAIN
A-7
WALL TO BE CONSTRUCTED
PARTITION CONSTR. TYPE
INCLUD'G UL # - SEE SHEET A-__
0 5 10 15 20 FT
SCALE 1/4" = 1'-0"
LASZLO SIMOVIC, ARCHITECTS, L.L.C.
TEL: 773-338-2225
EXTRUDED ALUMINUM EXTRUDED ALUMINUM
COPING, COLOR TO MATCH COPING, COLOR TO MATCH
PANELS, TYP. PANELS, TYP.
EL. + 20'-4" EL. + 20'-4"
TOP PARAPET TOP PARAPET
6512 N. ARTESIAN AVE.
CHICAGO, IL. 60645-5328
4'-2" 4'-1"
STONE PANEL, TYP. STONE PANEL, TYP.
7'-6"
NEW WINDOW SYSTEM WITH
BLACK ALUMINUM FRAMING, TYP. BLACK ALUMINUM CLAD STEEL 1'-9"
CANOPY SYSTEM WITH TRANSULUCENT
ROOF PANELS, TYP.
EMAIL: LASZLO@LASZLOARCH.COM
4'-2"
1'-6"
EL. + 13'-0"
FAX: 773-338-2226
FINISHED CEILING
1'-0" 1'-0"
2"
2" 1'-6" 2"
20'-4" 4'-2" 3'-3" 20'-4"
2"
13'-0"
4'-2" 11'-10" 11'-10" 11'-10"
10'-0"
PROVIDE 3/4" STAINLESS STEEL
CHANNEL AT CONNECTION BETWEEN
NEW EXTERIOR FACADE AND EXISTING
8'-1" EXTERIOR FACADE
2'-9 3/4"
03/21/2024
10"
2" EL. +/- 0'-0"
GRANITE BASE
FINISHED FLOOR
DATE:
COLOR TO MATCH
FACADE TYP.
112'-3"
NEW PARTIAL NORTH ELEVATION
SCALE: 1/4" = 1'-0"
PROGRESS PRINTING
NEW PARTIAL EAST ELEVATION Design Review DESCRIPTION:
SCALE: 1/4" = 1'-0"
NO.
EXTRUDED ALUMINUM
COPING, COLOR TO MATCH
PANELS, TYP.
EL. + 20'-4"
TOP PARAPET
STONE PANEL, TYP.
NEW WINDOW SYSTEM WITH
BLACK ALUMINUM FRAMING, TYP. BLACK ALUMINUM CLAD STEEL
PROVIDE 3/4" STAINLESS STEEL CANOPY SYSTEM WITH TRANSULUCENT
CHANNEL AT CONNECTION BETWEEN
NEW EXTERIOR FACADE AND EXISTING
ROOF PANELS, TYP.
EXTERIOR FACADE 7'-0"
EL. + 13'-0"
FINISHED CEILING
1'-0"
4999 OL ORCHARD
NOTE: PATCH & REPAIR
EXISTING CANOPY TO
MATCH EXISTING EXACTLY,
COLOR, SIZE, SHAPE, ETC.
(USE EXIST'G MANUF.)
PROJECT:
SHOPPING CTR, SUITE A28
NEW WINDOW TO MATCH
EXISTING EXACTLY, COLOR,
11'-10"
SIZE, SHAPE, ETC.
9'-6"
SKOKIE, IL 60077
EXISTING DECORATIVE
NEW RESTAURANT
COLUMN, ETC.
EL. +/- 0'-0"
FINISHED FLOOR
GRANITE BASE
COLOR TO MATCH
PROVIDE NEW DECORATIVE
COLUMN TO MATCH EXIST'G FACADE TYP.
EXACTLY, SIZE, SHAPE,
COLOR, ETC.
NEW PARTIAL EAST ELEVATION
SCALE: 3/8" = 1'-0"
OWNER:
EL. + 20'-4"
ALEXIOS GEORGES
TOP PARAPET
4999 OL ORCHARD
SHOPPING CTR, SUITE A28
SKOKIE, IL 60077
SHEET NAME:
New Elevations
PROJECT: 7438
PARTITION LEGEND SCALE: AS NOTED
WALL TO REMAIN DATE: 08/20/2023
WALL TO BE REMOVED
WALL FINISH TO BE REMOVED
STUDS TO REMAIN
A-8
WALL TO BE CONSTRUCTED
PARTITION CONSTR. TYPE
INCLUD'G UL # - SEE SHEET A-__
0 5 10 15 20 FT
SCALE 1/4" = 1'-0"
LASZLO SIMOVIC, ARCHITECTS, L.L.C.
SLOPE DN
TEL: 773-338-2225
RETURN WALL
SEE ROOF PLAN
OPEN AT BOTTOM
EXIST'G RUBBER NEW RUBBER
SLOPE DN SLOPE DN
PROVIDE 3/4" BRONZE
ROOF REVEAL AT CONNECTION BETWEEN ROOF TO
6512 N. ARTESIAN AVE.
CHICAGO, IL. 60645-5328
NEW EXTERIOR FACADE AND EXISTING MATCH EXIST'G
EXTERIOR FACADE
XX
EMAIL: LASZLO@LASZLOARCH.COM
FAX: 773-338-2226
K10.7 K11 K11.4 K12 L11.9
PROJECT TRUE
NORTH NORTH
2 NEW PARTIAL ROOF PLAN
SCALE: 3/8" = 1'-0"
INFILL EXISTING OPENING WITH
C
03/21/2024
MATERIALS TO MATCH EXISTING L
EXACTLY AT THIS SIDE
EMER. EXIT ONLY DATE:
XX
PROVIDE 3/4" BRONZE
PROGRESS PRINTING
REVEAL AT CONNECTION BETWEEN
PROVIDE NEW WINDOW TO NEW EXTERIOR FACADE AND EXISTING
MATCH EXISTING, EXACTLY. EXTERIOR FACADE
(COLOR, SHAPE, SIZE, ETC.)
Design Review DESCRIPTION:
PROVIDE NEW DECORATIVE
COLUMN TO MATCH EXIST'G
EXACTLY, SIZE, SHAPE,
COLOR, ETC.
K10.7 K11 K11.4 K12 L11.9
NO.
PROJECT TRUE
NORTH NORTH
1 NEW PARTIAL 1ST FLOOR PLAN
SCALE: 3/8" = 1'-0"
K10.7 K11 K11.4 K12 EXTRUDED ALUMINUM
COPING, COLOR TO MATCH
PANELS, TYP.
EL. + 20'-4"
TOP PARAPET
3'-1"
8'-7 1/4" STONE PANEL, TYP.
4999 OL ORCHARD
1'-5 3/4"
2'-7 7/8"
BLACK ALUMINUM CLAD STEEL
7 1/8" 7"
CANOPY SYSTEM WITH TRANSULUCENT
PROJECT:
SHOPPING CTR, SUITE A28
PROVIDE 3/4" BRONZE CHANNEL AT ROOF PANELS, TYP.
CONNECTION BETWEEN NEW EXTERIOR
FACADE AND EXISTING EXTERIOR FACADE NEW WINDOW SYSTEM WITH
11 3/4" 6'-7 3/4" 11 3/4"
BLACK ALUMINUM FRAMING, TYP.
EL. + 13'-0"
FINISHED CEILING
SKOKIE, IL 60077
1'-0"
NEW RESTAURANT
EXISTING DECORATIVE 14'-7 1/8"
COLUMN, ETC.
NEW WINDOW TO MATCH
EXISTING EXACTLY, COLOR,
11'-10"
OWNER:
SIZE, SHAPE, ETC.
GRANITE BASE, COLOR TO MATCH ALEXIOS GEORGES
STONE PANELS, TYP.
4999 OL ORCHARD
EL. +/- 0'-0"
SHOPPING CTR, SUITE A28
SKOKIE, IL 60077
FINISHED FLOOR
PROVIDE NEW DECORATIVE COLUMN TO MATCH EXIST'G FULLY ADHERED STONE BASE
EXACTLY, SIZE, SHAPE, COLOR, ETC.
CEMTENTIOUS FIBER BOARD PANELS, SMOOTH, WITH
GROOVES TO MATCH EXISITNG
TO MATCH EXISTING
NEW PARTIAL EAST ELEVATION
SCALE: 3/8" = 1'-0"
SHEET NAME:
Enlarged Front Elevation
PROJECT: 7438
SCALE: AS NOTED
DATE: 08/20/2023
A-13