Muyni
← Back to Winnetka

Design Review Board

Regular Meeting

Winnetka, IL · May 21, 2026

AgendaPacketMinutes

Minutes

Minutes adopted June 18, 2026. 1 Winnetka Design Review Board/Sign Board of Appeals Meeting Minutes 2 May 21, 2026 3 4 Members Present: Katie Moor, Chairperson 5 Chris Baggett 6 Wesley Barker 7 Colin Kennedy 8 9 Members Absent: Fritz Duda 10 Peter Evanich 11 Heather Niehoff 12 13 Village Staff: Scott Mangum, Director of Community Development 14 Ann Klaassen, Assistant Director of Community 15 Development 16 Davorka Kirincic, Building and Code Enforcement 17 Manager 18 19 Call to Order & Roll Call: 20 Chairperson Moor called the meeting to order at 7:00 p.m. Roll call was taken of the Board Members 21 present. 22 23 Approval of Minutes: 24 Chairperson Moor stated the May 7, 2026 meeting minutes would be approved at the next meeting. 25 26 Public Comments: 27 No comments were made at this time. 28 29 New Applications: 30 a. Case No. 26-09-DR: 574 Lincoln Avenue- Spynergy: A Sign Permit to allow two window signs, a 31 door sign and a wall sign at the storefront of the Subject Property. 32 Ms. Kirincic identified the property’s location, zoning classification, and the applicant's request. She 33 referred to storefront images with prior signage removed. Ms. Kirincic stated that the request is for the 34 proposed signage she identified in an illustration, along with the color samples she provided to the Board. 35 She described the lettering size and its compliance with Sign Code requirements, the signage text, and the 36 proposed door signage. Ms. Kirincic stated that door and window signage cannot be approved 37 administratively because it exceeds the limit for administrative review. She confirmed that the proposed 38 signage meets Code requirements, street exposure percentages, and the Design Guidelines 39 recommendations. 40 41 Ms. Kirincic stated that, following the applicant’s presentation, public comment, and Board discussion, 42 the Board may either continue the matter to a date certain to allow time to address questions or 43 comments or make a motion to approve or deny the sign permit. She asked if there were any questions. 44 45 Chairperson Moor also asked if there were any questions. No questions were raised at this time. 46 47 Matt Majewski of North Shore Sign and Liza Ritter, the business owner, introduced themselves to the 48 Board. Mr. Majewski confirmed the vinyl decal on the letter sample provided represented a color sample. Design Review Board May 21, 2026 Page 2 1 Chairperson Moor asked if there were any questions. Mr. Barker commented that the proposal looked 2 fine and was compliant with the guidelines. Mr. Kennedy confirmed it would be blue and not black. 3 Chairperson Moor stated it would be navy blue. Ms. Ritter confirmed blue is the brand color and added 4 that the second-floor shutters are blue as well. Chairperson Moor commented that it looked fine and 5 some of the text appeared to be competing and suggested its size be slightly reduced. 6 7 Mr. Baggett moved to issue a Sign Permit with the lettering size reduction as suggested by Chairperson 8 Moor. Ms. Klaassen stated that any conditions should be specific in terms of size. The Board Members 9 discussed amending the lettering sizes. 10 11 Mr. Baggett moved to issue a Sign Permit for the request as presented, with the condition that the signage 12 for “Movement, Music and Community” be reduced to 2 feet 1 inch. Mr. Kennedy seconded the motion. 13 A vote was taken and the motion was unanimously passed, 4 to 0: 14 AYES: Baggett, Barker, Kennedy, Moor 15 NAYS: None 16 17 b. Case No. 26-10-DR: 985 Green Bay Road — Minos Italian Restaurant: A Certificate of 18 Appropriateness of Design to allow installation of the new retractable awnings, new landscaping and 19 expansion of the outdoor patio seating area at the Subject Property. 20 Ms. Kirincic described the proposed improvements in detail and identified the property’s location and 21 zoning classification. She identified property views in an illustration, along with previous approvals for the 22 property, which she summarized for the Board. Ms. Kirincic noted on the site plan that there is a patio 23 and gravel area, with the current site plan showing the additional area for the right side. She then 24 described the prior approvals and improvements made to the property. 25 26 Ms. Kirincic stated that administrative approval was given today for broken concrete, with the applicant 27 proposing to replace it in the same color and material. She then identified the proposed awnings, patio 28 improvements, and dining area expansion along Green Bay Road. Ms. Kirincic described the proposed 29 landscaping replacement improvements and referred to the site plan, proposed specifications, and Village 30 Design Guidelines the applicant planned to follow, which are included in the agenda packet. 31 32 Ms. Kirincic stated that, following the applicant’s presentation, public comment, and Board discussion, 33 the Board may either continue the matter to a date certain to allow time to address questions or 34 comments, or make a motion to approve or deny the Certificate of Appropriateness. She asked if there 35 were any questions. 36 37 Chairperson Moor also asked if there were any questions. No questions were raised at this time. 38 39 Glenn Deutsch, one of the business owners, provided a sample of awning material to the Board for their 40 review. Chairperson Moor commented that the improvements looked nice. 41 42 Chairperson Moor asked for a motion. A motion to issue a Certificate of Appropriateness of Design for the 43 request as presented was made by Mr. Baggett and seconded by Mr. Barker. A vote was taken, and the 44 motion was unanimously passed, 4 to 0: 45 AYES: Baggett, Barker, Kennedy, Moor 46 NAYS: None 47 Design Review Board May 21, 2026 Page 3 1 c. Case No. 25-19-PD: 901-05, 907-09, 911-13 Green Bay Road and 1007-11 Tower Court - Tower 2 Court Condominiums Preliminary Planned Development: Certificate of Appropriateness to allow 3 construction of a new four-story mixed-use building as part of a planned development. The Village 4 Council has final jurisdiction on this request. 5 Ms. Klaassen reviewed the planned development process for the Board as well as the Village Council’s 6 comments during the concept plan review, the general site information, the subdivision and zoning relief 7 and planned development approval required for the plan. She stated she would provide information with 8 regard to the concept plan review changes since the Village Council’s review and the Board’s advisory role 9 in the process. Ms. Klaassen then identified site photos and described the proposal’s three main elements 10 which include approximately 15,000 square feet of ground floor commercial retail space, 15 residential 11 condominium units and onsite parking. Ms. Klaassen described the refinements made in detail to the plan 12 following the Village Council’s initial review. She then identified the rezoning and special use permit 13 required for the property as well as the parking requirements and height, side yard setback and rear yard 14 setback requirements. 15 16 Ms. Klaassen referred to the factors the Board is to consider with regard to whether a Certificate of 17 Appropriateness should be granted and the proposed plan’s consistency with the Design Guidelines. She 18 then stated following the applicant’s presentation, public comment and Board discussion, the Board may 19 decide to either continue the matter to a date certain to allow time to address questions or comments or 20 make a motion to recommend approval or denial of the Certificate of Appropriateness with draft language 21 included in the agenda packet. Ms. Klaassen read Mr. Evanich’s comments into the record and noted that 22 Mr. Duda agreed with Mr. Evanich’s comments. She added one public comment was received and 23 provided to the Board and then asked if there were any questions. 24 25 Mr. Kennedy questioned the height of the properties next door. Ms. Klaassen referred to an image of the 26 proposed building next to the neighboring two-story buildings and noted the applicant may have the 27 actual dimensions of those buildings. 28 29 Jon Talty, OKW Architects, introduced the applicant’s team to the Board who stated they also worked on 30 the One Winnetka project. He referred to images of several properties which he commented have outlived 31 their life with the goal being to create something better than what currently sits on the parcel. He stated 32 he would provide information with regard to the building quality, high quality materials and building 33 composition. Mr. Talty described the possible 15 maximum residential units with flexibility in terms of 34 unit size. 35 36 Mr. Talty stated the building’s materials would consist of true Indiana limestone, granite, brick masonry 37 with profound detailing. He stated after hearing the Village Council’s comments and concerns, they were 38 mindful of the three-dimensional aspects of the building in terms of eroding its mass and it would be 39 perceived as a three-story building noting the buildings across the street are also three stories. Mr. Talty 40 also stated substantial outdoor spaces would be provided for each unit and referred to an illustration for 41 the Board’s review. He described how shade and shadow became an important part of the architecture 42 with the use of granite and limestone. Mr. Talty identified the lower-level parking entrance and 43 condominium entry in the rear. 44 45 Mr. Talty explained the development standards they considered in terms of the building’s context. He also 46 identified the lower-level residential parking which would provide an abundance of parking. He stated the 47 ground floor is intended for retail and commercial space with the developers being confident it would be 48 entirely leased in terms of commercial demand. Mr. Talty noted the restaurant tenant at the corner was Design Review Board May 21, 2026 Page 4 1 removed in order to create a more calm and appropriate environment for the residents above. He 2 described the secure residential entry and stated the floors were partitioned in terms of how they would 3 be laid out. Mr. Talty informed the Board that One Winnetka had 594 names on a waiting list for 59 4 apartments with there being a tremendous demand for this type of residences. He also described how 5 the building is carved back at each level in order to reduce the mass. Mr. Talty explained the reasoning 6 for not having fourth floor penthouses with the parapet being 49 feet 8 inches with 45 feet being allowed 7 in order to allow significant ceiling heights. He stated roof stair access would be installed as a fire 8 department requirement. 9 10 Mr. Talty then explained their consideration of including Tudor aspects and their attempt to maintain the 11 idea of it being a retail corridor with viable livable retail and housing above. He referred to sketches of 12 condominium details along with descriptions of the various material elements. Mr. Talty also referred to 13 neighboring buildings which have two stories and referred to a rendering of how the building would sit 14 on the street along with building elevations which he described in detail. He also described the retail 15 component in detail as well as streetscape improvements. Mr. Talty then provided a shadow study to the 16 Board and stated there would be no detriment to the neighbors. 17 18 Colleen Barkley, the Mariani Landscape Director of Design, stated they worked with Village staff and 19 Village Forester to incorporate the Hubbard Woods Streetscape Plan and the inclusion of tree specimens 20 as well as other tree species she identified to soften the building and provide shade. She also described 21 the planting beds, flowering shrubs, etc. to be used in the plan. Ms. Barkley also stated there would be 22 raised planters and perennials along with annuals to flank the main condominium entrance. She then 23 provided illustrations of the proposed planters. 24 25 Mr. Talty explained the reason for downplaying the exterior lighting on the building and described the 26 proposed lighting plan in detail. He then asked if there were any questions. 27 28 Chairperson Moor asked if there were any questions. Mr. Baggett questioned how Tower Court is exited, 29 which Mr. Talty explained to the Board. Mr. Baggett stated his concern related to the increased amount 30 of traffic in that area. Mr. Talty responded the building would be a low traffic generating facility by the 31 residents and minimal traffic from the consumer side. Mr. Kennedy questioned the light levels and the 32 balconies having independent lighting control. Mr. Talty responded the predominant light source from 33 the building would be internal. 34 35 Anders Rustin, OKW Architects Project Manager, stated there is a code requirement for the one-foot 36 candle minimum in terms of building egress and the streetscape lighting would light the sidewalk paths. 37 He also stated there would be more linear decorative fixtures at the retail portion of the building to 38 provide architectural intervention. 39 40 Mr. Kennedy asked what considerations were taken to prevent a restaurant tenant in the future, which is 41 a big concern. Peter Witmer stated they initially considered a restaurant tenant and referred to the 42 practicality of having a restaurant tenant as well as traffic, parking and smell concerns it would create for 43 the residential building. He stated it would be mentioned in the bylaws and that there may be a possibility 44 of a small coffee shop in the future. Mr. Talty added that there would not be sufficient infrastructure for 45 a restaurant tenant. Mr. Kenndey questioned the reasoning for not including Tudor design which Mr. Talty 46 explained to the Board. 47 Design Review Board May 21, 2026 Page 5 1 Chairperson Moor stated her concern related to items being visible from the balconies. Mr. Talty stated 2 the condominium association would be profoundly restrictive in terms of what is allowed on balconies. 3 He also identified the Lake Forest project which is the most analogous to the proposed building. Mr. Talty 4 referred to the streetscape rendering on Green Bay Road. Chairperson Moor stated she appreciated the 5 attempts made to reduce massing and stated she is still concerned with the overall size and its 6 compatibility with what is on either side. Chairperson Moor also commented that the building looked 7 urban in the downtown setting. Mr. Talty reiterated how the fourth floor would be positioned far back 8 with it not being seen from the street view perception. Chairperson Moor suggested there be more 9 articulation for the third floor. Mr. Talty explained the reasoning for the third-floor articulation in that 10 they did not want it to become repetitive. Chairperson Moor referred to the building across the street 11 and stated although there is a need for additional housing, she questioned other ideas they may consider, 12 and they should be careful that whatever is built in Hubbard Woods would change the district 13 dramatically. Mr. Talty agreed and stated they want to set a high bar in terms of what is to come. 14 15 Mr. Barker agreed with Chairperson Moor’s comments and agreed that while a phenomenal job was done 16 on the proposal, he cannot get past the height. He stated if the top floor was removed, it would fit in more 17 with the Hubbard Woods neighborhood. Mr. Talty noted the building is 4 feet 8 inches taller than what is 18 allowed and if it is reduced, it would reduce ceiling heights. Chairperson Moor asked if there were any 19 other questions. No additional questions were raised at this time. 20 21 Chairperson Moor then asked for public comment. John Joyce, Managing Director of SVN Chicago 22 Commercial, described the four sites he developed and sold to Altounian Construction. He stated there 23 are several open Hubbard Woods stores which he described as functionally obsolete. Mr. Joyce also noted 24 that there are a number of apartments above the storefronts in these existing buildings, so there won’t 25 be a big increase in traffic. He then referred to several other developments in the surrounding 26 communities and stated the proposed development would be exciting for the community. He also 27 referred to several other successful developments in the Village. No additional comments were made at 28 this time. 29 30 There were no additional public comments. 31 32 Chairperson Moor called the matter in for discussion. She referred to the Board Members’ concerns 33 relating to scale. Chairperson Moor stated she did not feel it is appropriate to make a recommendation of 34 approval and stated while they support the need for development, there is work to be done on the 35 proposal in order to make it more contextually appropriate for the community. Mr. Barker agreed with 36 Chairperson Moor’s comments and stated his concerns related to building height. 37 38 Mr. Talty asked if the building was 45 feet in height, would they have the same opinions and asked how 39 they bridge the gap. Chairperson Moor advised the applicant their consideration related to the building’s 40 appearance and there are other steps required for approval including the need for five zoning variations. 41 She also stated if the building was located in another part of town, it would not look as out of place as it 42 did in the current location. Chairperson Moor also referred to the comments related to Tudor style 43 architecture; the discussion relating to the Chase Bank building and stated the building would take up a 44 large portion of the block. Mr. Kennedy agreed the height is massive and suggested more continuity be 45 made with regard to the two neighboring properties. Chairperson Moor also asked for the balcony railings 46 to be closed. Mr. Talty asked if the Green Bay Road balconies should be treated differently than balconies 47 elsewhere on the building. Chairperson Moor suggested possibly and referred to the greenery on the 48 upper floor. Design Review Board May 21, 2026 Page 6 1 A Board Member questioned the process in terms of the applicant’s review. Ms. Klaassen stated the next 2 regular DRB meeting would be on June 18, 2026, and referred to whether the applicant is able to make 3 changes prior to that time. Mr. Talty stated they would appreciate taking the time to consider the Board’s 4 changes and come back before the Board. Ms. Klaassen stated the matter could also be continued to the 5 July 16, 2026, meeting, if additional time is needed to address comments from the DRB. Ms. Klaassen 6 stated the matter can be continued to June 18, 2026, and if the applicant is not prepared, it can be 7 continued to the July meeting. Mr. Talty agreed with Ms. Klaassen’s suggestion. The Board Members 8 discussed their availability for the June meeting. Chairperson Moor asked for a special meeting to be called 9 if necessary. Ms. Klaassen confirmed she would check with the absent Board members to confirm their 10 availability. 11 12 Chairperson Moor asked for a motion to continue the matter to the June 18, 2026, meeting. A motion as 13 stated by Chairperson Moor was made by Mr. Barker and seconded by Mr. Kennedy. A vote was taken 14 and the motion unanimously passed, 4 to 0: 15 AYES: Baggett, Barker, Kennedy, Moor 16 NAYS: None 17 18 Other Business. 19 a. June 4, 2026, Special Meeting Quorum Check. 20 The Board Members discussed their availability and confirmed a special meeting was previously scheduled 21 for June 4, 2026. 22 23 Adjournment: 24 Chairperson Moor asked for a motion to adjourn. A motion to adjourn was made by Mr. Kennedy and 25 seconded by Mr. Barker. A vote was taken and the motion unanimously passed, 4 to 0: 26 AYES: Baggett, Barker, Kennedy, Moor 27 NAYS: None 28 The meeting was adjourned at 8:45 p.m. 29 30 Respectfully submitted, 31 32 Antionette Johnson 33 Recording Secretary

Agenda

Village of Winnetka Design Review Board/Sign Board of Appeals Regular Meeting May 21, 2026 at 7:00 PM Winnetka Village Hall Council Chambers 510 Green Bay Road AGENDA 1. Call to Order 2. Public Comments 3. New Applications a. Case No. 25-09-DR: 574 Lincoln Avenue — Spynergy: A Sign Permit to allow two window signs, a door sign, and a wall sign at the storefront of the Subject Property. b. Case No. 26-10-DR: 985 Green Bay Road — Minos Italian Restaurant: A Certificate of Appropriateness of Design to allow installation of the new retractable awnings, new landscaping, and expansion of the outdoor patio seating area at the Subject Property. c. Case No. 25-19-PD: 901-05, 907-09, 911-13 Green Bay Road and 1007-11 Tower Court - Tower Court Condominiums Preliminary Planned Development: Certificate of Appropriateness to allow construction of a new four- story mixed-use building as part of a planned development. The Village Council has final jurisdiction on this request. 4. New Business a. June 4, 2026, Special Meeting - Quorum Check b. June 18, 2026, Regular Meeting - Quorum Check 5. Adjournment NOTICE Public comment is permitted on all agenda items at the meeting. If you wish to provide testimony or comments prior to the meeting, you may provide them one of two ways: (1) by sending an email to planning@winnetka.org; or by sending a letter to Community Development, Village of Winnetka, 510 Green Bay Road, Winnetka, IL 60093. All agenda materials are available at www.villageofwinnetka.org/agendacenter. The Village of Winnetka, in compliance with the Americans with Disabilities Act, requests that persons with disabilities, who require certain accommodations to allow them to observe and/or participate in this meeting or have questions about the accessibility of the meeting or facilities contact the Village ADA Coordinator at 510 Green Bay Road, Winnetka, Illinois 60093, (Telephone (847) 716-3543; T.D.D. (847) 501-6041).

Packet

Village of Winnetka Design Review Board/Sign Board of Appeals Regular Meeting May 21, 2026 at 7:00 PM Winnetka Village Hall Council Chambers 510 Green Bay Road AGENDA 1. Call to Order 2. Public Comments 3. New Applications a. Case No. 25-09-DR: 574 Lincoln Avenue — Spynergy: A Sign Permit to allow two window signs, a door sign, and a wall sign at the storefront of the Subject Property. b. Case No. 26-10-DR: 985 Green Bay Road — Minos Italian Restaurant: A Certificate of Appropriateness of Design to allow installation of the new retractable awnings, new landscaping, and expansion of the outdoor patio seating area at the Subject Property. c. Case No. 25-19-PD: 901-05, 907-09, 911-13 Green Bay Road and 1007-11 Tower Court - Tower Court Condominiums Preliminary Planned Development: Certificate of Appropriateness to allow construction of a new four- story mixed-use building as part of a planned development. The Village Council has final jurisdiction on this request. 4. New Business a. June 4, 2026, Special Meeting - Quorum Check b. June 18, 2026, Regular Meeting - Quorum Check 5. Adjournment NOTICE Public comment is permitted on all agenda items at the meeting. If you wish to provide testimony or comments prior to the meeting, you may provide them one of two ways: (1) by sending an email to planning@winnetka.org; or by sending a letter to Community Development, Village of Winnetka, 510 Green Bay Road, Winnetka, IL 60093. All agenda materials are available at www.villageofwinnetka.org/agendacenter. The Village of Winnetka, in compliance with the Americans with Disabilities Act, requests that persons with disabilities, who require certain accommodations to allow them to observe and/or participate in this meeting or have questions about the accessibility of the meeting or facilities contact the Village ADA Coordinator at 510 Green Bay Road, Winnetka, Illinois 60093, (Telephone (847) 716-3543; T.D.D. (847) 501-6041). Page 1 of 207 MEMORANDUM VILLAGE OF WINNETKA COMMUNITY DEVELOPMENT DEPARTMENT TO: DESIGN REVIEW BOARD FROM: DAVORKA KIRINCIC, AICP BUILDING AND CODE ENFORCEMENT MANAGER DATE: MAY 14, 2026 SUBJECT: 574 LINCOLN AVENUE – SPYNERGY – WINDOW, DOOR, AND WALL SIGNS PERMIT (CASE NO. 26-09-DR) INTRODUCTION On May 21, 2026, the Design Review Board (DRB) is scheduled to consider a sign permit application submitted by Spynergy (the “Applicant”), as the lessee of the commercial space located at 574 Lincoln Avenue (the “Subject Property”), to allow two new window signs, a door sign, and a wall sign at the Subject Property. PROPERTY DESCRIPTION The Subject Property is the commercial space located on the west side of Lincoln Avenue between Elm and Pine Streets. It is zoned C-2 General Retail Commercial Overlay District. The Applicant is leasing a commercial space, which Mandarine most recently occupied. Figure 1 below shows the location of the Subject Property, and Figure 2 on the following page identifies the storefront on the building's exterior facade. Location of 574 Lincoln Avenue Figure 1 – Subject Property – Location Map Page 2 of 207 Location of Spynergy Storefront Figure 2 – Subject Property – View of the entire building from Lincoln Avenue PREVIOUS REQUEST On June 24, 2021, DRB approved an awning and double-faced projecting sign for the previous business “Mandarine” at Subject Property. CURRENT REQUEST The Applicant is seeking approval to install two new window signs, a door sign, and a wall sign. The proposed signs would identify and promote their business. Signs will feature the text and colors of their businesses, as shown in the illustrations below: Wall Sign • Located on the Lincoln Avenue façade within the brick sign band above the storefront windows; • Individual pin letters displaying the text “Spynergy” in a navy-blue color; • Letter height of 12 inches; • Bottom of sign located approximately 12 feet above the sidewalk; • Non-illuminated sign; and • Total sign area of approximately 9.33 square feet Page 3 of 207 Subject Property – Location and detail of the wall sign Window #1 Sign • Individual vinyl text applied on the exterior of the glass; • Text in white stating “Movement Music Community” in upper-case letters 7 inches tall and lower-case letters 5 ¼ inches tall ; • Located in the bottom two-thirds portion of the glass height; and • Sign area 5.38 square feet. Window #2 Sign • Individual vinyl text applied on the exterior of the glass; • Text in white stating “SPYNERGY” in upper-case letters 7 inches tall; • Text in white stating “feel the energy” in lower-case letters 4 inches tall; • Located in the bottom two-thirds portion of the glass height; and • Sign area 3.69 square feet. Page 4 of 207 Door Sign • Individual vinyl text applied on the exterior of the glass; • Text in white stating “SPYNERGY” in upper-case letters, 2 1/2 inches tall • Text in white stating “spynergystudios.com” in lower-case letters, 1 inch tall • QR code in white 5 inches tall by 5 inches wide; and • Sign area 0.92 square feet. A copy of the Application materials is included in Attachment A. SIGN CODE ANALYSIS Section 15.60.120 of the Village Sign Code establishes standards for Wall and projecting signs in commercial districts. Wall Sign Standards • Sign may only contain the business name, a three-word generic description of the types of products or services offered, and the occupant’s logo or trademark; • Sign may not exceed 70 square feet in area; • Shall be placed substantially parallel to the surface of the wall; • Shall not be located above the second-floor windowsill level and shall not be higher than fourteen (14) feet above grade if there is no second-floor windowsill; • Comply with the following: for each street exposure, the total area of all wall signs, window signs, and awning signs other than exempt signs and permitted directional and incidental signs shall not exceed 15% of the street exposure; and • Commercial wall signs shall be displayed only upon street exposures, except that one wall sign not exceeding 20 square feet in area may be displayed by each occupant on each non-street exposure of the premises occupied by such occupant. The proposed wall sign meets all the above standards. Window and door window signs that meet the following standards can be administratively approved by staff: • Window signs limited to 10% or less of the single windowpane; Page 5 of 207 • Door sign limited to 50% or less of the single door window; • Limited letters and logos no taller than 8”, except one logo, and the first letter of each word may be up to no taller than 24”, and except store hours and contact information shall be limited to 2” in height; • Window signs limited to letters and logos of no more than two colors on a solid background of another color, a total of three colors; • Height of the sign to not exceed 1/3 of the height of the glass area and 90% of the glass width; • Located in the lower two-thirds of the window opening; • Shall not extend over or through architectural features/window muntin; • Without reflective materials; • No window sign should be illuminated, and • Comply with the following: for each street exposure, the total area of all wall signs, window signs, and awning signs other than exempt signs and permitted directional and incidental signs shall not exceed 15% of the street exposure. The proposed door and window signs meet all the above standards. Signage Street Exposure Area Square Percentage Foot Street Exposure 285.88 - Max Allowed per Sign Code 42.88 15% (15% of the Street Exposure) All Proposed Signs counted toward Street Exposure 19.32 6.76% The proposed signs comply with the maximum allowed sign area for street exposure. The Board should also consider the Village Design Guidelines for the proposed signs. See Attachment B. SUMMARY The Applicant requests that the DRB find the proposed signs appropriate and compatible with the Sign Code and the Village Design Guidelines and approve the application as proposed. Should the DRB find the proposed improvements appropriate, the Applicant would first need to obtain the approved sign permit from the Community Development Department before installing the sign. FINDINGS & RECOMMENDATION At the May 21 DRB meeting, the DRB is scheduled to consider the design of the Applicant’s proposed wall, window, and door signs. After hearing from the Applicant and the public, the DRB will have the following options: 1) Continue the public hearing to a specific date to provide the Applicant and/or staff with additional time to address questions and comments from the DRB; or 2) Consider a motion for approval or denial of the Sign Permits. A DRB member should make a motion for approval or denial based upon the following findings of fact per Section 15.60.150(F) of the Sign Code: a. The proposed projecting sign is consistent [is not consistent] with the following standards used for issuance of a sign permit: Page 6 of 207 1. The sign area shall be in proportion and scale to the building or to other buildings or signs in the surrounding area; 2. A signage package for a business establishment that includes a number of signs and graphics shall have an overall plan that demonstrates the compatibility of the design and colors of all the signs that are part of that package; 3. The amount of text and graphics contained in or on any sign or group of signs shall be limited so that it results in a clear and readable design; 4. Signs and graphics shall have a harmonious relationship with nearby signs, buildings and the neighborhood, and shall be designed so as not to adversely affect adjacent structures. In this respect the sign shall relate to its building, structure and neighborhood in terms of size, shape, material, color, texture, lettering, location, arrangement, lighting, and the like; 5. Colors shall be used with restraint and excessive brightness shall be avoided; 6. The additional provisions of this chapter, as specified in this chapter, shall be part of the criteria of the design review process. b. [If the DRB chooses to place conditions as part of its approval, it will want to include the conditions here.] ATTACHMENTS Attachment A: Application Materials Attachment B: Design Guidelines Excerpt Page 7 of 207 ATTACHMENT A Village of Winnetka SIGN PERMIT APPLICATION v ILL AGE o F w INN ET KA, 1 LL IN o��CEIVE DEPAR1MENT OF COMMUNITY DEVELOPMENT � � � 0 2026 SIGN PERMIT APPLICATION BY:____ Tenant/Lessee Name of Business Primary contact name Spynergy Liza Ritter Project Address 574 Lincoln Ave City State Zip Code Winnetka IL 60093 Sign Company Name of Sign Company Primary contact name North Shore Sign Matt Majewski Street Address 1925 Industrial Dr Oty State Zip Code Libertyville IL 60048 Property Owner Name of Company Primary contact name Doug Sharfstein Doug Sharfstein Street Address: 574 Lincoln Ave City State Zip Code Winnetka IL 60093 Sign type(s): D window graphics [i) wall-mounted sign D ground-mounted sign ■ (check all that apply) projecting sign D other___ Additional description of sign type and materia\sNon-iluminated flush mounted dimensional letter sign and refacing the existing blade sign. OFFICE USE ONLY SIGN FEE: $80 NON-ILLUMINATED PER SIGN TYPE "!SO)( Z. 1f'° $ \,o.oc:, $195 ILLUMINATED SIGN $___ STAFF REVIEW FEE: $70 0 WAIVE FEE $ �0.00 TOTAL PERMIT FEE sL!O.Qa CONDITIONS OF APPROVAL: _______________________ Page 4of4 Page 8 of 207 9' -4" lM'DIAINStONAt. I.OGO.:OP'( {1) NEW SET OFDIMENSIONAL WALL LOGO/COPYREQ. ALL MlI.Nr5 CDNCEAlEO • -- --1--NON-QllWII OW'E ALL PENETMTllNS uao FASCIA SL4UOW/tt-atADE: Stll:Of£�T 10/l4 AWMINUM "'°"°' ----4--S1UOSSC.1£WS)IMTO COP'Yll.OGQ:WAU Pl£0M.l.fDYI' SllGHR.YLAIIG&I 1«:UtkA.NSlUO -FURNISH S INSTALL [1) NEW SET OF OIMENSKINAL WALL COPY -3/4" ROUTED DIMENSIONAL LOGO/COPY W/ PIN MOUNTS 6 HEAVY DUTY ADHESIVE [FOR EXTERIOR -�INT: -NON-ILLUMINATED FASCIA MOUNTING) -LOGO: ORANGE -FLUSH MOUNTED TO BUILDING FASCIA -BRICK -COPY: NAVY BLUE IF� r....ii Colen deplcllld on this drawing are irlnted slmulatloos to assist In visualizing the design. TIiey do not accurately retlect lie actualcolcrs specHied. TIiisdesign II Ille aduslve pnpertyol Nor111Sllore Sign Cmnpany Inc., and Is Ille resurt ol lie or1.-.,a1 alld "QUALITY SIGNAGE SINCE 1 lllO" c11atlve wollt olltsemi,oyees. TIiis draWlng Is submlted lolle respeclfve custmn• tortlle soil-• NORTH SHORE ol conslder.afon ol wllllh• or nol to purdlase this disign, or a sign manulactured to this design tam Norlh 511018 Sign CO. DISll1bullon, use -� or lllllltmln Ill Ills draWlqi to ...... DI.bide custmnn ______ SIGN 19:i!S I\IOUSTIUL DRIVE. LIIERTVVI.LE. IL 60048 • 847-818-70:i!O 0111anlzalon,ln ofllerto seCUftl quo1aaon, dlsign wort<, ar IM,l'Ci.se of a sign either to Ills design orslmlar to this deslg11 ls expressly 1or1i1-. In the -lhet such 11-111•11 use ar ellllbllon occur,, North Sllare Sign lsto be co11111m*d $1500.110 farlme, elortalld c11allve NN!ce enlilled In crealfqi these IUIUY !fans. as well as any and al legal lies alld •- to - ls dghls. Capyr!Vlt 2020 Nor111 Sllore Sign fU TAPE75 ML CO-nylnc. Page 9 of 207 ...,.. .... . .. ·--�"-7)�4'-:�.�.:-����-•�·��� ' -: -·•·.· . •. . ., - .•• •'. . ,· ;, •- -�-- ·�:,>',· ,. . . . . r . - . � I N SPYNERGY IIIIIF r ,ail Colors deplclad on tllls drawing are prlrted sanulalorw 111 assist In vls1.allzlng tlle deslgrL ..,8 They do not accurately reflect Ile actual colors specitled. TIU clesig• It tile exchlliw p,q,er,v rs! Notlh 511)111 Sig• Compa,ty !AC. IAd is 1he 111Mllt Ol 118 0� Md -OUAUlY SIGNAGE SINCE 1930' cnatM - Of Its employees. Thia clraWIA9 is 111l11ritlod to Ille re1119clhe customer tor tile Ide 1111� NORTH SHORE of COA1idt11I0AOI Wbelhlr or A0II0 1111tt11- lhlt dellII", or • 11911 mMllladlnd to Ille deli9II hom Noll!I Sllo,.Slg• Co. Dlstrll11a1o-. ute o� or exlllilfOII oru,e clraWl•9 to •JO• autlldeciatormrs ______ SIGN 019111lzalo., IA order to teClll9 QU0tallOII, cleslg• wo,t,, or Pllfdl•• Ola llg•ellherlo Ille clesig• or llmlar DAlE lo 1hls dtllg., e eqnsllylorb-. 111 lhe -t Ulat such dlslrllluto., ute or ellllllltlOII occun,Notlh 4-28-26 1925 INOUSTRIAL0RNE. LIBERTVVILLE, L 80048 • 947•919•7020 SlwnSig• l1lobecompe•- $1500.00lor.,.,elfortalllc•tllNI senlce •laled l•creat11191hese DUNIIY pl••• as well • •Y aod al 199111 lees1Ad expe•es lo •"orce IU9tts. Ccpyrl91C 2020 North 5110111 Sl9R IU 1,1. TAPE75 Compaoy IIIC. Page 10 of 207 - FURNISH & INSTALL (1) NEW SET OF EXTERIOR WINDOW VINYL 6'-41W GLASS WINDOW - 1ST SURFACE APPLICATION MATERIALS VINYL TO BE INSTALLED - 3M EXTERIOR WINDOW VINYL IN BOTTOM 2/3nos OF GLASS [M)@W@M@mJ� 00 "' [M](Ll]�□ @M Mill] [n] D � COLORS/GRAPHICS/FONTS - VINYL: WHITE 4'-6" (1) NEW EXTERIOR WINDOW VINYL REQ. • r..a �� Colors depleted on this drawing are printed simulations to assist In visualizing the design. They do not accurately reflect the actual colors specified . TIiis do�gn Is thtexduslve property ol North Short Sign Company tnc., ind It the rosult of the origlnal and •QUALITY SIGNAGE SINCE 1930• creative work of Its employtts. This drawing la &1.1bmitted to the rt1pective customer for the 1ole purpose NORTH SHORE of con1lderatlon of whether or not to purchase this design, or• sign manufactured lo this design from North Shore Sign Co. Dlstribullon, use of, or exhibition of this drawing to anyone outside customers _______ SIGN Ofganltatlon, In o,der to secure quotation, design wOB, or purchase or a 1lgn either to this 6eslgn « slmlar to this design, b exprestly forbidden. In the event that sud'I distribution, use Of exh.lbltlon occurs, North "" 4-24-26 REVISEOARfWORK DIIAwtfBT 1925 INDUSTRIAL ORNE, UDERTVVlllE. IL 60048 • 847.818-7020 J'JUN Shm Sijln 11 to be compensated $1500.00 for time, effort and creatfle service etitalled In creating thest plans, as well as any and aH legal fees and 11penset to IKII0rca its rights. Copyright 2020 North Shore Sign Company Inc. T PE75 5~14-26 ML Page 11 of 207 • FURNISH & INSTALL (1) NEW SET OF EXTERIOR WINDOW VINYL GLASS WINDOW • 1ST SURFACE APPLICATION I s:;i 5' • D" - - - -- - - - - - - - - - - - - VINYL TO BE INSTALLED MATERIALS • 3M EXTERIOR WINDOW VINYL �w IN BOTTOM 2/3nos OF GLASS -� 00 (0 "' s"' ro ;;,. := � � �@� I ff@@� �lhl@ @lfil@lr@I ! - - - - - - - - - - - - - - - - COLORS/GRAPHICS/FONTS • VINYL: WHITE s:;i (1) NEW EXTERIOR WINDOW VINYL REQ. IJ' r.. CoSors depleted on this drawing are printed simulations to assist In visualizing the design. .Ail They do not accurately reflect the actual colors specHled. This design Is the excfuslve PfOptfty of North Shore Sign Company Inc., acid Is the resuft of the ortglnal and ·auAUTV SIGNAGE SINCE 1930• creative work of Its employHs. This drawing ii submitted to the rt1pectiv1 customer for lht sole purpon NORTH SHORE of consideration of Wtlether or not to porchase this des�n. or I a.lgn manufactured to U'Ns desli,n from North Shore Sign Co. OlstrlbuUon, use of, or exhibition of this drawing to anyone outilde customers _______ SIGN """" org.-.lutlon, In or6er to secure quotation, des.lgn work, or ptirchase 011 sign elttter to this design Of aimlar to this dealgn_ ls expressly forbidden. In the event that such distribution, use or exhlilltlon occun, North 4-24-26 REV/SEO ARTWORK 1925 INOUSTRIALORIVE, UBERT'l'VIU.E, IL 60048 • 847.816-7020 Shore Sign Is to be compensaled S1500.00 for time, effort and creative strvlce entalled In creating these ptans, as well as lfly and au legal ltes and expenses to enforce tts rights. Copyright 2020 North Shore Sign fl( TAPE 75 514·26 ML Compenyklc. Page 12 of 207 FRONT VIEW (SIGN 6 - FRONT DOOR] & IMPOSED VIEWS (SIGNS 4-6) -FURNISH S INSTALL (1) NEW SET OF EXTERIOR WINDOW VINYL - 1ST SURFACE APPLICATION 2' - 6112- 2' -0" MATERIALS ��VU's!l��@J - 3M EXTERIOR WINDOW VINYL � N > '° (") spynergystud!Qs.«:om ;.... os�ordlslhicre lo COLORS/GRAPHICS/FONTS -VINYL: -LOGOS COPY: WHITE -QR CODE: DIGITALLY PRINTED •NOTICE- NEEO CUSTOMER PROV/0£0 QR COO£ PRIOR TO PRINTING* (11 NEW EXTERIOR WINDOW VINYL REQ. -- IJ' r�� They Colors depicted on this drawing are printed simulations to assist In vlsuaJizing the design. do not accurately reflect the actual colors specl11ed, This design is the exdusive property 01 North ShOre S�n Company lnc., and Is the result of the origlnM and "DUALITY SIGNAGE SINCE 1930" creative work of its employ&es. This dtawlng ii aubmitted to the respective customer for the ,ote purpose NORTH SHORE of consideration of whettier or not to purchase this dfflgn, or• sign ma nufactured to this deslliJII from Horth Shore Sign Co, Distribution, use of, or exhibition of this drawing to anyone outsltSe customers _______ SIGN Ofganlzallon, In order to ,ecure qootatron, design wl>f1(, or purchase of a sign either to th!t detlgn or similar to lhb detlgn. Is expressly forbidden. In the ennt that such distribution, use or exhibition occurs, North -2 ·26 REVISED ARTWORK ORlllltCBY 1925 INDUSTRIAL OFllVE, UBEATYVILlE, ll 60048 • 847-B16-7020 BYB Shon1 Sign Is to be compensated $1500.00 for time, effort and creative service et1!alled In creati ng ll'lest plans, as wll as any and all legal teu and expenses 10 en1orce Its rights. C09yr1ght mo North Shore Sign Company Inc. Fl[ TAPE75 5-14·26 Ml Page 13 of 207 ATTACHMENT B G Building Signage Commercial signs should reflect the character of the building style, while expressing each store’s individuality. There are several prominent sign styles that are appropriateto Winnetka: surface mounted, pin-mounted, interior, decal and projecting blade signs. Sign materials are limited to painted wood, canvas, architectural glass and metal. Sign color must harmonize with the building upon which it is mounted and adjacent structures. Letteringcolor can be unique to the image of the retailer/user. Metal sign and plaque materialsuch as brushed bronze, antique bronze, aluminum, stainless steel and painted cast ironor similarly appearing materials are preferred. Highly reflective metallic signs are notallowed. Signs should be lit by marquee or spot lighting; neon lighting is not permitted.Spot lighting should be minimal and unobtrusive and, per the Village Code, the sourceof illumination shall not be visible from any street, sidewalk or dwelling. Simplifiedindustrial light fixtures are not permitted. Contextual solutions are recommended. Themajority of the signs will be mounted within the building’s sign band, defined as thewall area located above the ground floor storefront opening and below the second floorwindowsill, and is located a minimum of 8’-0” above grade anda maximum of 15’-0”above grade. 0&DPHQGHG Signs must comply with the general provisions of the Winnetka Sign Ordinance as well as design provisions contained within these Design Guidelines.  Surface mounted commercial signs are either fabricated from painted wood orcast metal plaques and are to be mounted within the sign band or within thestorefront transom. The height of the sign is restricted to 75% of the area of thesign band or 14 inches - whichever is less. The sign band of a building consists ofthe area located above the ground floor storefront opening and below the secondfloor windowsill, and is located a minimum of 8’-0” and a maximum of 15’-0”above grade. Refer to figures 28, 29, and 30 for location. Surface mounted orpin- mounted signs are not permitted on secondary elevations without a definedsign band. 2. Pin-mounted commercial signs consist of reverse channel, cast metal and flat cut metal letters mounted above the storefront in the masonry sign band or suspended in front of the storefront at the transom or recessed entry. The size of the lettering is restricted so that the height of the letters does not exceed 75% of the height of the sign band or 14 inches - whichever is less. The length of the lettering is to be Figure 38 contained within 75% of the length of the sign band. (See figure 38) 19 Building & Architecture Page 14 of 207 MEMORANDUM VILLAGE OF WINNETKA COMMUNITY DEVELOPMENT DEPARTMENT TO: DESIGN REVIEW BOARD FROM: DAVORKA KIRINCIC, AICP BUILDING AND CODE ENFORCEMENT MANAGER DATE: MAY 14, 2026 SUBJECT: 985 GREEN BAY ROAD – MINOS ITALIAN RESTAURANT - CERTIFICATE OF APPROPRIATENESS OF DESIGN TO ALLOW EXTERIOR PROPERTY IMPROVEMENTS AT SUBJECT PROPERTY (CASE NO. 26-10-DR) INTRODUCTION On May 21, 2026, the Design Review Board (DRB) is scheduled to consider an application submitted by Glen Deutch (the “Applicant”), as the lessee of the property located at 985 Green Bay Road (the “Subject Property”). The Applicant is requesting approval of a Certificate of Appropriateness of Design to allow exterior property improvements at the Subject Property. The proposed scope of work includes installing three new retractable awnings on the building, replacing existing planters, repairing the existing brick patio paving, and expanding the existing outdoor dining area along Green Bay Road. Additional hardscape and landscape enhancements are also proposed in support of these improvements. These modifications are associated with the operation of Mino’s Italian Restaurant. PROPERTY DESCRIPTION The Subject Property is located at the northeast corner of the intersection of Green Bay Road and Merrill Street in the Hubbard Woods Business District and contains a one-story commercial building and outdoor dining area. The Subject Property is located in the C-2 General Retail Commercial Zoning District and in the Commercial Overlay District. Figure 1 below identifies the location of the Subject Property and Figure 2 identifies the building's exterior facades. Location of Subject Property Figure 1 – Subject Property – Location Map Page 1 Page 15 of 207 Figure 2 – Subject Property – View of the building /Intersection of Green Bay Road & Merrill Street PREVIOUS APPROVALS On April 27, 2017, the DRB approved the following: (1) exterior building alterations, which incorporated much of the original building materials and form; (2) various site improvements that included removal of a significant portion of pavement and replacement with pea gravel on September 21, 2017; and (3) an outdoor storage container and service area on February 15, 2018. On May 17, 2018, the DRB approved a Certificate of Appropriateness for the installation of an outdoor dining area and other hardscape improvements, including wood and metal planters, metal table sets, brick pavers, and a stamped concrete patio for private events. On May 16, 2019, the DRB approved a Certificate of Appropriateness for the expansion of the outdoor dining area and other external improvements, such as planters with “green” screening to create a more private dining and lounge area. The approved plan added approximately 1,050 square feet to the outdoor dining area, accommodating approximately 50 patrons with metal table sets and red brick pavers designed to match the existing patio. The approved plan included installing 16 black planter boxes to provide privacy and enhance aesthetics. Each planter box was to be 4 feet in length, 1.5 feet in width, and 2 feet in height. The planters were to be filled with tall grasses and climbing vines supported by a trellis that would reach 6.5 feet in height. On July 18, 2019, DRB approved a Certificate of Appropriateness to change the approved landscaping plan to eliminate the black planter boxes and install a gridded fence/trellis with creeping vine vegetation. The proposed black fence was 3’9” inches in height, to match the existing planters around the patio. Page 2 Page 16 of 207 Subject Property – outdoor seating patio expansion area approved by DRB on May 16, 2019 CURRENT REQUEST The Applicant is seeking to allow exterior property improvements, including installing three new retractable awnings on the building, removing a section of fencing, replacing existing planters, repairing the existing brick patio paving, and expanding the existing outdoor dining area along Green Bay Road. Ground landscaping would be installed around much of the perimeter of the site along Green Bay Road and Merrill Street. Additional hardscape and landscape enhancements are also proposed in support of these improvements, as shown in the illustrations below: Page 3 Page 17 of 207 Subject Property – Proposed Awning renderings and specifications Page 4 Page 18 of 207 Page 5 Page 19 of 207 Subject Property – Proposed outdoor seating patio expansion area and landscaping The Applicant has provided a site plan and design specifications for the proposed exterior improvements, which are available in Attachment A. Page 6 Page 20 of 207 DESIGN GUIDELINES ANALYSIS The Village’s Design Guidelines provide guidance on outdoor dining areas and open spaces. An excerpt of the Design Guidelines is included as Attachment C. SUMMARY The Applicant requests that the DRB find the proposed exterior property improvements appropriate and compatible with the Design Guidelines and approve the plan as proposed. Should the DRB approve the certificate of appropriateness for the proposed exterior property improvements, the Applicant would first need to receive a building permit from the Community Development Department prior to construction. FINDINGS & RECOMMENDATION At the May 21 DRB meeting, the DRB is scheduled to consider the design of the Applicant’s proposed exterior property improvements at Subject Property. After hearing from the Applicant and the public, the DRB will have the following options: 1) Continue the public hearing to a specific date to provide the Applicant and/or staff with additional time to address questions and comments from the DRB; or 2) Consider a motion for approval or denial of the Certificate of Appropriateness. A DRB member should make a motion for approval or denial based upon the following findings of fact per Village Code Section 15.40.010 F: a. The proposed exterior property improvements are consistent [are not consistent] with the following standards used for evaluating a certificate of appropriateness: (1) the proposed external architectural features and site improvements are appropriate to and compatible with the character of the immediate neighborhood; (2) the proposed external architectural features and site improvements are appropriate to and compatible with adopted Village plans for and improvements in the immediate neighborhood, and including both urban design and site arrangement considerations; (3) the proposed external architectural features and site improvements are consistent with applicable Village design guidelines and such standards and criteria as may be adopted by the Board; and (4) the probable effect of the proposed external architectural features on the integrity of the immediate vicinity. b. [If the DRB chooses to place conditions as part of its approval, it will want to include the conditions here.] ATTACHMENTS Attachment A: Application Materials Attachment B: Design Renderings Approved at May 16, 2019 DRB Meeting Attachment C: Design Guidelines Excerpt Page 7 Page 21 of 207 ATTACHMENT A Page 22 of 207 Page 23 of 207 Page 24 of 207 Page 25 of 207 Mint Julep Juniper (JCM) Switch Grass (pv) MINO'S Dwarf Burning Bush (EA) 985 GREEN BAY ROAD, WINNETKA, ILLINOIS Bloody Cranesbill (gs) Page 26 of 207 Tardiva Hydrangea (HP) OUTDOOR DINING RENOVATION Periwinkle (vm) Groundcover Rose (RDS) Page 27 of 207 Page 28 of 207 Page 29 of 207 Page 30 of 207 Page 31 of 207 Page 32 of 207 Page 33 of 207 Page 34 of 207 Page 35 of 207 Page 36 of 207 Page 37 of 207 Page 38 of 207 ATTACHMENT B VILLAGE OF WINNETKA, ILLINOIS DEPARTMENT OF COMMUNITY DEVELOPMENT APPLICATION FOR CERTIFICATE OF APPROPRIATENESS • DR/3 5.16.})t: PROJECT ADDRESS EX NUMBER NAME oF sus1NEsscEs) 1M, t-Jo's I rtrkl Abl Application is hereby made for the following work (please check all that apply): ign wning Other (general description) Sign permit application attached? Awning permit application attached? Pk-Tl O A:cl>C not,,) B Please provide a detailed description of the proposed work (attached separate sheets, material specifications, photographs, etc.): I/We hereby certify chat as y:g 'i"E' (Lessee/Owner) of the property at ��$" <,gee,tl W el)(address) I am/we are authorized to submit plans for alteration of the subj� propeny. I/We agree to perform the subject work in accordance widt the condiuons of approval by the Winnetka Desjgn Review Board, as well as an other applicable codes, rules amd regulations of the Village ofWiitnetka. SIGNED PRCNT NAME(S) .- ADDRESS 4'.10S:: "20.fJ;JU f?A:Y Ob 1 �-·� WI f:JNETkA: (k boPS 3 PHONE NUMBER J?3 1Qb 131 b illi!l�:. PRIMARY DESIGN FIRM tsnE:$t<A /..OtJ!,l) Lt4::N't1 CONTACT NAME ,)OA,,,UJA lsPLAkOW.SCd ADDRESS APR 2 6 2019 PHONE NUMBER FAX NUMBER Application for Certificate of Appropriateness Page 39 of 207 Page4 ofS MIND'S - ADDITION TO OUTDOOR DINING PLAN 985 GREEN BAY RD., WINNETKA Summary Approximate Timing The p)an is to create an additional outdoor dining and lounge May Install and Plant area for people who are waiting for a table or simply want to enjoy a cocktail outside on a nice summer night. Brick pavers to match the existing patio will be installed to create the surface area. Planter boxes will be placed around the edge of the patio to provide a more intimate setting. These planter boxes will have gridded screens that allow plants to grow and climb, creating more "green" and enhancing the intimate atmosphere. 985 GAEEN BAY RD., WINNETKA MIND'S - ADDITION TO OUTDOOR DINING PLAN LOTN_oz Page 40 of 207 ;/t)�·:i\/Ni{l{{:� //}�\1:· < �.,.::;..,.�.,.£.;i�i:;;�=;:=;:=;=-;;i=J�=i...J�;:;.�.,_������S;;d,;;;;,,;�.:;.;�'-,.;;..__j.a.,,1..,.,1,w i-t· ,�·�}/J f:,,Sl n;ie,f """ f.-tl'','f- . � ·tll:;till t:>��:::r·J �,\IOf;;l• ��.; /:"- (:; •.itt 1 JO } ',,' � �.. ... .. 1!:r:::t�!�����i�t�i&-A���,-.4�.£......£-i;:::.'.qd=<{;,/4i,lll�-----<l���;;,all ·_:L·�:}i'.i;;;:;�.:-,:·;o,oi: r:�:-�;{/ " .,_, �· r.--· ·::·� }: �....,.---w-..,-...,,�......,->-,.-1,...,......,.,,....-......v-..---- !it" -- -- 1 C� i}i; t. A. •• ,_ --�=" !) v--v---,·-..,-..., D:!STit..C 3' c• Ollf alNC'll IT SUHf AQ Proposed Addition to Patio Dining Area 985 GREEN BAY RD .. WINNETKA MIND'S - ADDITIONAL PATIO DINING AREA LOTN_oz Page 41 of 207 985 GREEN BAY RO .. WINNETKA MIND'S - DETAIL OF ADDITIONAL PATIO DINING AREA LOT N_oz Page 42 of 207 Red brick pavers in a herringbone pattern to match existing patio 985 GREEN BAY RD., WINNETKA MIND'S BRICK PAVERS LOT N_oz Page 43 of 207 985 GREEN BAY RD .. WINNETKA MIND'S - PLANTERS WITH SCREENS LOTN_oz Page 44 of 207 � � . .•• s � � � t= �� lo � � Planter boxes will be black - - Wilshire Screen GFRC Planters --- Part.No. Trellis Grid 1btal Height to PlanterSize WWght SadValume tapofSael!II ObsJ (cubic ft) WCX3-481824-78 3" 7fr 48L X 18"W X 24"H 318 10 WCX&-481824-78 6. 7f!' 48L x 18"W x 24•H 321 10 WCX-481824-78 Use WXS screen ]fr 481. X 18"W X 24"H 304 10 WCXJ-482424-78 3• 7fr 48L X 24'W X 24"H 353 13 WCX6-482424-78 6" 7fr 48L X 24"W X 24"H 356 13 WCX-482424-78 Use WXS screen 7fr 481.x24"Wx24"H 339 13 985 GREEN BAY RD .. WINNETKA MIND'S - PLANTERS WITH SCREENS LOT N_oz Page 45 of 207 Seating tor approximately 50 people with lounge area. Tables and chairs to match what's being used on existing patio. 985 GREEN BAY RD WINNETKA MIND'S - TABLES AND CHAIRS LOTN.0 2 Page 46 of 207 ATTACHMENT C XV. OPEN SPACE A common element unifying Winnetka’s Business Districts, Multiple Family Residential and Institutional Areas are the unique public and private open spaces they have been created over time. Many of these open spaces lend to Winnetka’s sense of place, culture and history. The Village’s open spaces range in size and activity level from the large and active Hubbard Woods Park to the small and passive sculpture corner near Village Hall. The Village has expressed a desire to expand its open space system and link, where possible, these spaces together in a unified Village open space plan. a. Purpose. To ensure that current and future open spaces contribute to Winnetka’s ambiance; public and vehicular streetscapes should link open spaces to create a unified, continuous landscape system with mature plantings and seasonal interest. By working as a system, the Village’s open spaces intend to: • physically and symbolically unify and enhance the Village’s natural features and character; • preserve significant areas and encourage new tree, shrub and perennial plantings on public and private properties to the greatest extent possible; • encourage pedestrian and bicycle circulation throughout the Village, especially among the Business Districts; • create gathering points for Village events and activities; • provide educational opportunities about the natural environment; and • enhance property values. b. Location. With this purpose in mind, new public and private developments within the Business Districts, Multiple Family Residential and Institutional areas should provide for ample, appropriately designed open space within the proposed site development plan. Recognizing the spatial limitations of each site, creative, relevant open space should strive to enhance the Village’s natural character. Public, semi-public, or private open space and landscaped buffers should be located between low and higher density areas and to serve as a transitional element between land uses. Where new or existing developments abut adjacent planned or existing open spaces, every effort should be made to integrate open spaces and link them into a unified whole. 67 Public Spaces/Streetscapes Page 47 of 207 d. Pedestrian Zone Landscaping. Streetscapes within the Business Districts, Multiple Family Residential and Institutional areas should be designed to provide pedestrians with shade and visual interest. Providing adequate landscaping within the pedestrian zones is an essential element to maintaining and enhancing the Village’s streetscape character. Irrigation and appropriate drainage are recommended for all landscaped areas, especially for raised planters. The following landscaping guidelines should serve as a continuation and supplement to the Village’s on-going tree planting program in all public rights-of-way. Existing and new developments should preserve existing trees and minimize disruptions through grade changes or installation of underground utilities and structures. Tree planting in the public way and/or on adjacent setbacks should extend and complement the existing street character or establish a character if none exists. The existing landscape character in public parkway/streetscape varies with the Business Districts, Multiple Family Residential and Institutional areas. Overall, these characters should remain intact and be enhanced. In general, the Business Districts’ public parkway character is that of a paved streetscape pedestrian zone. Where widths of paved areas are wider than six feet, street trees are planted in either at-grade tree grates or raised curb planters. This condition should be continued in all new and existing developments within the Business Districts. The Village encourages the use of raised concrete planters with both street trees and understory plantings as outlined in these guidelines. In general, Multiple family Residential and Institutional areas, public parkway character is that of a concrete walkway in conjunction with a planted parkway area. That parkway area width varies by location but is predominantly planted with street trees and a turf lawn area. This condition should be continued with in all new Multiple family Residential and Institutional areas. 1. Plant Palette: An approved Village plant palette is included in these guidelines for reference. (See Appendix B) The Village encourages a variety of species, sizes, and types of plant materials that provide appropriate impact/coverages as well as seasonal interest. Plants selected by the Village on this list are chosen for their hardiness, disease resistance, ease of maintenance and character. 2. Parkway Widths: Within the Business Districts the sidewalk widths between the curb and building line range from five to as much as 15 feet. Multiple Family Residential and Institutional areas typically have five-foot wide sidewalks with associated green parkway areas. Along Green Bay Road, sidewalks currently range from five to six feet in width (See Appendix D). 35 Public Spaces/Streetscapes Page 48 of 207 Village of Winnetka, Illinois Sidewalk areas in new developments should maintain a minimum pedestrian clear zone of 6 feet in combination with landscaping and streetscape amenities where space permits. The parkway width will determine the type of streetscape enhancements feasible in that area while maintaining the necessary six-foot wide pedestrian clear zone. (See Figure 52) Typical Parkway Widths (see Figure 52): 6’-9’Wide 6 feet – 9 feet. Where the parkway or pedestrian clear zone is less than nine feet wide, street trees are not suggested. Movable planters, decorative paving, or basket planters on light poles are preferred alternatives. 9 feet – 12 feet. Where parkways are greater than nine feet wide in commercial or multiple family districts, street trees should be planted within tree grates that are flush with the sidewalk or planted in a raised 9’-12’Wide curb planter. The six-foot clear pedestrian zone should not be obstructed by streetscape elements. If tree grates are required for maintaining minimum pedestrian clear zone clearances, the grate size should be five feet by five feet or four feet by six feet. The tree grates shall conform to the design standards and soil volume specifications of the Village. Greater than 12 feet. All pedestrian zones greater than 12 feet in width should contain street tree plantings in designed raised concrete curb planters. Where appropriate, seating areas and sidewalk cafes are encouraged. However, these improvements should not overwhelm the sidewalk nor impede on the 6-foot pedestrian clear zone. Design Guidelines 36 Page 49 of 207 3. Street Tree Selection and Spacing. Street trees selected for the Business District, Multiple Family Residential and Institutional area streets shall be large deciduous canopy trees tolerant of roadside conditions such as salt and air-borne pollutants. Tree varieties and locations shall coordinate with existing planting patterns. Grouped and linear plantings may be explored as part of an overall site development plan concept. The minimum caliper size for single stem deciduous street tree plantings should be 4 inches. All shade trees shall have a minimum clear branch height of 6 feet above the root ball at time of planting. (See Figure 54) Street tree spacing should be a minimum of 20 feet and a maximum of 40 feet on center in the parkways and pedestrian zones. (See Figure 52) 4. Street Tree Planting Standards. Street tree plantings in all new developments should be designed to meet the minimum standards as established by the Institute of Traffic Engineers (ITE) guidelines in order to ensure safe, efficient use of the pedestrian areas. These minimum standards are intended to provide ample sight triangles and clearances for motorists at intersections, alleys, commercial or multifamily residential driveways. The Village shall at its own discretion review and approve each parkway tree planting plan on a case-by-case basis. In general, street trees should be planted in a straight row manner (on center) at the appropriate spacing and conformity with existing street trees adjacent to the development site. Newly planted street trees should be no closer than 3 feet on center from the face of the curb. All trees should be planted in the center of raised or grade-level planter areas with tree grates. All street trees in grassed parkway areas should be planted as true to the center of the parkway as possible due to utility, signs or other existing obstructions. No street trees should be planted in open grass/lawn parkways less than 4 feet in width as measured from the back of the curb. (See Appendix C) 5. Visual Clearance. Landscaping should not block views or pedestrian sidewalks at its mature size and should not create safety or maintenance problems. Minimum branch clearances at time of planting should be 6 feet in height. Shade trees should be an upright single stem spreading species. (See Figure 54) Minimum 6’ branch height for visual clearance Figure 54 37 Public Spaces/Streetscapes Page 50 of 207 Village of Winnetka, Illinois Sight triangles at driveways and at parking and loading access points should not be less than 12 feet as measured along both intersecting rights of way lines. No plant material should be installed in the triangle exceeding a maintained growth height greater than 12 inches. (See Figure 55) Figure 55 6. Structural Soil and Planting Soil Depth. In instances when the parkway width is 4-5 feet, the use of structural soils and root channels should be considered in adjacent paved walks to link green areas. (See Figure 56) Structural soil at a depth of 2 ½ feet should be used under all sidewalks where landscape plantings/street trees are located as well as between planter or grates to permit root growth in the parkway. Along with structural soil, root paths should be considered as necessary sidewalk improvements to allow street trees to reach Structural Soils Detail their maximum growth potential. For at- Figure 56 grade plantings of shade trees, minimum soil depth should be 3 feet; for shrubs, 18 inches, and 6 inches for grass and groundcovers. A minimum soil volume for street trees in sidewalk grates should be 125 cubic feet. Design Guidelines 38 Page 51 of 207 7. Raised planters. Where possible, street trees and multi-tiered planting in continuous raised planters is encouraged. Multi-tier means providing additional plant material below street trees, such as shrubs, perennials and groundcovers. These additional plantings should provide a variety of coordinated color and seasonal interest to the streetscape. Continuous raised sidewalk planters with expansive planting soil volumes are preferred. (See Figures 57, 58, and 59) Minimum Streetscape/Parkway Raised curb planters should be Cross-section with raised planter approximately six inches in height and a Figure 57 minimum of 3 ½ feet wide (inside dimension); however, a 5-foot inside width dimension is preferred. The raised planters should also contain a continuous decorative 18-inch metal railing around the curb top and be of a style reflecting the Village standard or the proposed development plan (See Figure 59). The length of these planters should be designed to accommodate store entrances, signs and other streetscape elements. Soil should be mounded to 6 inches above the top of the planter curb at the center of the planter. Mulch, groundcover, or other Typical Raised Planter/Railing Treatments appropriate plantings in conjunction with Figure 58 the appropriate street trees should be provided. Where appropriate, adequate GFI electrical outlets should be provided for each individual street tree or combinations of trees in the Business Districts. Typical Raised Planter/Railing Treatments Figure 59 39 Public Spaces/Streetscapes Page 52 of 207 Village of Winnetka, Illinois 8. Movable Planters. Movable planters are encouraged for sidewalks and open spaces too narrow to accommodate raised curb planters. (See Figure 60 and Appendix A for more information). Various styles of Movable Planters Figure 60 9. Light Pole Planter Baskets. Light pole planter baskets are encouraged for sidewalks and open spaces unable to accommodate at-grade planters. c. Special Pedestrian Zone/Streetscape Conditions 1. Outdoor Sidewalk Cafes. Dining establishments, coffeehouses or cafes are encouraged to provide adequately spaced outdoor seating. The Village encourages the use of these small outdoor spaces to help enliven the streetscape. Careful attention must be paid to maintaining a pedestrian clear zone. Tables, chairs, umbrellas, service equipment and planters should be kept out of the pedestrian clear zone. (See Figure 61) Appropriate outdoor sidewalk caféspace /alley enhancement Figure 61 Design Guidelines 40 Page 53 of 207 A temporary or seasonal designed barrier element is encouraged to ensure a clear demarcation of these spaces. The business or property owner should erect a simple decorative railing, fence, planters or similar element. The height of such a barrier should be no greater than 36 inches and constructed of a solid durable material easily anchored and removed in the paved space. The design of the barrier should reflect the architectural style of the building or coordinate with the Village streetscape elements. Maintenance and Typical paved crosswalk upkeep of the barrier is the sole Figure 62a responsibility of the business proprietor or building owner. 2. Corner Bump Outs. The Village encourages the use of bump-outs, or widened walkways, at street corners. These bump outs serve numerous functions: they slow traffic, highlight pedestrian crossings, encourage pedestrian gathering and allow for the incorporation of streetscape elements into the streetscape design. (See Figures 62a, and 62b) Corner bump out softens on-street parking Bump-outs should only be used in the with landscape and streetscape elements business districts at key intersections Figure 62b where feasible. They may also be used at corners where transitions occur from multiple family or institutional uses, such as in the Indian Hill District Bump-outs must be designed to meet the Engineering Design Specifications of the Village and, when applicable, of IDOT to provide a safe and proper turning radius for vehicular traffic along with appropriate sight lines and compliance with ADA standards. 3. Bus Stops. Bus stops currently exist at selected PACE locations throughout the Figure 63a Village. Where bus stops occur in the business districts and along the Green Bay 41 Public Spaces/Streetscapes Page 54 of 207 MEMORANDUM VILLAGE OF WINNETKA COMMUNITY DEVELOPMENT DEPARTMENT TO: DESIGN REVIEW BOARD FROM: ANN KLAASSEN, ASSISTANT DIRECTOR DATE: MAY 14, 2026 SUBJECT: 901-913 GREEN BAY ROAD & 1007-1011 TOWER COURT TOWER COURT CONDOMINIUMS - PLANNED DEVELOPMENT PRELIMINARY PLAN REVIEW (CASE NO. 2025-19-PD) INTRODUCTION On May 21, 2026, the Design Review Board (the “DRB”) is scheduled to consider a preliminary planned development plan application filed by Tower Court Winnetka LLC (the “Applicant”), as the owner of the properties located at 901-05 Green Bay Road, 907-09 Green Bay Road, 911-13 Green Bay Road, and 1007- 1011 Tower Court (the “Subject Property”). The designated architect for the project is OKW Architects. The Applicant has filed an application seeking approval of a certificate of appropriateness, a plat of consolidation, a rezoning map amendment, a preliminary planned development plan with zoning exceptions and special uses, and demolition permits to remove the existing structures. At the May 21 meeting, the DRB will review the design of the proposed building, signage, and landscaping and streetscape improvements as part of its recommendation regarding a Certificate of Appropriateness to allow the construction of a new four-story mixed-use planned development on the Subject Property, which consists of the following elements: a) Approximately 15,800 square feet of commercial space on the ground level; b) 15 residential condominium units on the three upper levels; and c) A total of 55 parking spaces consisting of 9 spaces at street-level and 46 spaces on the lower (underground) level for the residential uses. Figure 1 – Tower Court Condominiums – View from Southwest Corner Page 1 Page 55 of 207 The application materials are included in Attachment A. The Planned Development Commission will be holding a separate public hearing on approvals for the plat of consolidation, rezoning, preliminary planned development plan and associated zoning exceptions and special uses. The date of that meeting will be set once the DRB has completed its review. The Historic Preservation Commission is tentatively scheduled to consider the demolition permits for the existing buildings on July 6, 2026. Once the meeting date is confirmed mail notices will be sent to property owners within 250 feet of the Subject Property. Property owners within 250 feet of the Subject Property have been notified of the DRB meeting by mail notice. As of the date of this memo, the Village has yet to receive any written public comments regarding the proposed project. PLANNED DEVELOPMENT PROCESS The review process consists of the following major steps: Pre- Application Concept Preliminary Final Plan Meeting w/ Plan Review Plan Review Review Staff Figure 2 – Planned Development Review Process Concept Plan Review. The concept plan review step is conducted by the Village Council. The purpose of the Village Council’s review of the concept plan application is to broadly acquaint the Council with an applicant’s proposal. This step also provides the applicant with any preliminary concerns members of the Council may have early in the process when adjustments are still possible and prior to the applicant expending the funds necessary to prepare the complete documentation required for a preliminary plan application. After hearing the comments and suggestions from the Village Council, the applicant decides whether or not to proceed with the project. If they do proceed, the applicant then must submit a preliminary planned development application with all the required documents for review and recommendation by the Planned Development Commission and the DRB. On October 21, 2025, the Village Council conducted the concept plan review of the proposed four-story mixed-use building. The current preliminary proposal is generally consistent with the site layout and building design as presented at the October 21, 2025, concept plan review. However, the previously proposed ground-level restaurant and the rooftop penthouses and amenities have been eliminated in response to comments from Council members. A few images from the October 2025 concept plan review are on the following page. Page 2 Page 56 of 207 Figure 3 - Concept Plan – Ground Floor Plan Presented to Council October 21, 2025 Figure 4 - Concept Plan –Green Bay Road Elevation Presented to Council October 21, 2025 During the concept plan review, Council members expressed that they were generally open to the proposed development and the addition of housing in the area; however, individual Council members stated that the following issues should be carefully considered during the preliminary planned development process: a) Regarding building design: a. Most of the trustees expressed reservations with the design and scale, and encouraged the Applicant to focus on a design that would be more contextual to the Hubbard Woods District. b. Most of the trustees were concerned with the proposed building height. The Applicant was encouraged to reconsider the height and consider additional articulation to minimize the appearance of building height and mass. Page 3 Page 57 of 207 c. One trustee expressed concern with making Hubbard Woods more urban rather than continuing the intimate design of the district. b) Regarding the commercial space: a. Most of the trustees commented on parking. One trustee expressed a strong concern with parking if a restaurant occupies space and suggested exploring an additional level of below-grade parking to accommodate the commercial uses and to expand the lower-level parking to the lot lines. b. One member expressed concern with Rebel House Design requesting approval of a special use permit (SUP) to occupy space within the Commercial Overlay District and suggested that tenant be located further from the street so that a SUP is not necessary. c. Another member expressed concern that the market pressure will result in non-retail tenants and encouraged the Applicant to be mindful of the objectives of the Commercial Overlay. c) Regarding compensating benefits: a. One trustee commented that additional public benefit is needed and also encouraged the Applicant to consider sustainability. b. One trustee asked if solar was being considered and another trustee asked if not solar, would the Applicant consider a green roof. A copy of the staff report for the Council’s October 21, 2025, meeting as well as a copy of the meeting minutes are included as Attachment B. Preliminary Plan Review. As previously stated, the Applicant has submitted an application for preliminary planned development approval. Preliminary plan review includes the following steps: Planned Design Review Development Village Council Staff Review Board Commission Consideration Recommendation Recommendation Figure 5 – Preliminary Plan Review The DRB’s role is to provide a recommendation to the Village Council regarding the design of buildings, structures, signage, and landscaping that are part of a proposed planned development in the context of the requested zoning relief. The Planned Development Commission’s role is to provide a recommendation to the Village Council regarding proposed zoning relief. Though not the purview of the DRB, the additional zoning relief is summarized later in this report. Upon the DRB forwarding a recommendation regarding the design of the proposed project, the Planned Development Commission will consider the requested zoning relief. Final Plan Review. The final plan review step of the planned development process is to ensure the plan to be constructed is consistent with the approved preliminary planned development plan. Final plan review consists of the following steps: Page 4 Page 58 of 207 Staff Village Review Council Figure 6 – Final Plan Review During the final plan review process, the Council may return the final application to the Planned Development Commission and/or the DRB for further consideration and recommendations to the Village Council. Unless the Council returns the application to the DRB during the final plan review process, the DRB will only review the request during this preliminary plan review process. DESCRIPTION OF PROPERTY The Subject Property, which consists of four parcels, is approximately 0.69 acres in size, and is generally located on the east side of Green Bay Road, between Tower Road and Gage Street (Figure 7). Tower Court runs along the rear (east) property line. The existing buildings on the site are a mix of commercial, mixed use, and residential buildings. Current commercial tenants of the various buildings include Rebel House Design, Red Spade Environments, Bella Bleu Bridal, Alexandra Kaehler Design, Munder Skiles Exterior Furniture, and Europa Motors. Subject Property Figure 7 – Aerial Map The 1007-1011 Tower Court parcel is zoned D – Light Industrial, the 907-911 and 911-913 Green Bay Road parcels are zoned C-2 General Retail Commercial, with a portion located in the C-2 Overlay District as shown in Figure 8. Finally, the remaining 901-905 Green Bay Road parcel is split between C-2 General Retail Commercial, with a portion located in the C-2 Overlay District, and D – Light Industrial at the rear of that property. Page 5 Page 59 of 207 Subject Property Figure 8 – Zoning Map The Village’s Comprehensive Plan designates the Subject Property as appropriate for commercial and mixed-use land uses as shown in Figure 9. Figure 9 – Comprehensive Plan Land Use Plan – Winnetka Futures 2040 Plan CURRENT PROPOSED PLAN As previously stated, the Applicant has submitted a preliminary planned development plan for a four- story mixed-use building which consists of the following: • 15,800 square feet of commercial space on the ground floor level; • 15 residential condominium units consisting of 2 and 3 bedrooms on levels 2-4; and • 55 parking spaces; 9 spaces at street-level and 46 spaces on the lower-level (underground). Page 6 Page 60 of 207 Site & Building Design The residential units would be accessed by a lobby off of a one-way drive-aisle along the south side of the proposed building. The lower-level parking for the residential units would also be accessed from this drive-aisle via a ramp on the south side of the building. The proposed drive-aisle would be one-way eastbound; vehicles would enter from Green Bay Road and exit onto Tower Court. The Applicant anticipates residential units measuring 2,700 square feet to 4,200 square feet. All residential units would have outdoor living spaces. Commercial tenant spaces would front on Green Bay Road and along the drive-aisle. The Applicant has identified Rebel House as a tenant along Green Bay Road, in the northwest corner of the commercial space, which would require special use approval since the use would be located within the Commercial Overlay District. According to the Applicant’s narrative included in Attachment A, the commercial space is intended to accommodate a mix of retail uses and personal service uses, similar to the current tenant mix in the existing buildings on the Subject Property. The plan also calls for a covered arcade, or outdoor seating area, for use by commercial tenants, on the south side of the building along the pedestrian access and drive-aisle. There is a loading and trash area identified in the northeast corner of the building that would be accessed from Tower Court. The nine (9) street-level parking spaces would be parallel spaces along the drive-aisle and the rear of the building along Tower Court. The Applicant intends for these spaces to be used by commercial tenants and guests of the residential units. The lower-level parking would accommodate parking for 46 vehicles, four (4) of those parking spaces would be tandem-style. Currently, there is a curb-cut on Green Bay Road for a driveway located between 907-909 Green Bay Road (Bella Bleu Bridal) and 911-913 Green Bay Road (Munder Skiles). This approximately 10-foot-wide curb- cut would be eliminated and a new approximately 15-foot-wide curb-cut for the proposed drive-aisle would be constructed on the south side of the Subject Property. In terms of exterior light fixtures, the Applicant has provided images of the proposed fixtures, which primarily include two different sized wall sconces and landscape light fixtures. There is an existing pad-mounted transformer located immediately south of the Subject Property that may or may not be adequate to accommodate the proposed development. The Village Water & Electric Department will confirm if the existing transformer is acceptable once the Applicant confirms its total service size and requested voltage. Based on the State electric vehicle charging requirements, it is likely the existing transformer does not have adequate voltage to accommodate the development. If that is the case, the Applicant will need to plan for a 10’ x 10’ accessible area for a pad-mounted transformer to service the development. The front of the transformer would have to be unobstructed, ideally facing Tower Court, with no parking in front of it. Page 7 Page 61 of 207 Figure 10 – Preliminary Plan – Site Plan The proposed building materials include red brick and buff cut stone, with a grey (or similar color) granite wall base. The commercial spaces would have large aluminum framed storefronts in a bronze color. The residential windows would also be a bronze aluminum frame. The entrances into the commercial spaces, as well as the residential lobby entrance, would have fluted stone pilasters with a decorative bronze panel above each entrance. The fluted pilasters at the residential entrance would extend two stories to add definition and texture, as well as a focal point for the residential component of the development. On the front and south elevations, there would be stone pilasters on the second and third floor levels. A stone cornice would surround the building between the third and fourth levels. The design of the building includes areas where the building walls are stepped back, which allows for private residential terraces to be incorporated into each unit. These terraces would have decorative metal railings in a bronze color. At the front of the building, the fourth story is set back 13 feet with residential terraces at the fourth floor level. An upper story setback is required by the Zoning Ordinance to reduce the perceived scale of the building at the sidewalk. The roof would be flat with a rooftop solar array and mechanical units. A pre-finished metal screen in a silver color would be installed to screen the mechanical units. Page 8 Page 62 of 207 Figure 11 – Preliminary Plan The proposed design also calls for installation of blue (“Storm”) fabric awnings above the commercial storefront windows. Signage design has not been finalized. However, the Applicant has included signage concepts in the plans to help illustrate the intent. Figure 12 – Preliminary Plan – Green Bay Road Elevation Page 9 Page 63 of 207 Figure 13 – Preliminary Plan – South Elevation (Drive-aisle) Figure 14 – Preliminary Plan – North Elevation Figure 15 – Preliminary Plan – East Elevation Figure 16 – Building Section (East) Page 10 Page 64 of 207 Figure 17 – Building Section (South) Streetscape & Landscaping Design The Village is in the midst of a streetscape planning effort for the Hubbard Woods Business District and is planning to make streetscape improvements within the public right-of-way in the business district, similar to the streetscape improvements made in the Elm Street Business District. Green Bay Road is controlled by the Illinois Department of Transportation (IDOT), which requires certain design standards. The Village is exploring a Jurisdictional Transfer in order to obtain ownership of the roadway which would provide more design flexibility. The Village anticipates it will take several years to work with IDOT to determine if the streetscape improvements will be made as an IDOT or Village-controlled right-of-way. Once that decision is made, it will take some time to prepare construction documents and begin the streetscape improvements. Currently, the streetscape project is in the Phase 1 Engineering stage, which is expected to be completed this summer. The Applicant is aware of the streetscape design concepts and will coordinate landscaping and streetscape improvements with the Village. It is expected that due to the timing of the Hubbard Woods Streetscape project, construction of the proposed development will commence prior to construction of district-wide streetscape improvements. That being said, the Applicant is aware of the streetscape design concepts and has incorporated elements into the proposed plans to be in keeping with streetscape features in the concept plans. In terms of landscaping, the Applicant is proposing landscaping on the south side of the drive-aisle, consisting of 7 Prairie Sentinel Hackberry trees and 54 dwarf bush honeysuckles distributed between the trees. On the north corner of the drive-aisle entrance, at Green Bay Road, there would be a landscape bed with three (3) Whitespire Birch trees and low-growing plantings. The Applicant is also proposing three different styles and sizes of planters along the north side of the drive-aisle. The planters would be concrete; the finish and color are yet to be determined. The small planters (Planter A) would flank the entrances and would contain a mix of annuals. The residential lobby entrance would also have two (2) larger circular planters (Planter B) with a mix of dwarf Korea lilacs and perennials. Two of these same planters would be evenly distributed between rectangular planters located between the commercial and residential entrances that would also receive a mix of Bobo hydrangeas and perennials. Additionally, the Applicant is proposing removal of six (6) parkway trees within the Green Bay Road right- of-way and replacing them with four (4) trees. After the planting of parkway trees, planting on private property may be counted towards the required replacement of the parkway trees. The Applicant is working with the Village Forester on the specific planting requirements. Page 11 Page 65 of 207 Figure 18 – Preliminary Plan – Planting Plan Changes Since Council Concept Plan Review As previously stated, the preliminary planned development plans presented for the DRB’s consideration are generally consistent with the plan reviewed by the Village Council at the concept plan review stage. The following summarizes the more significant changes and refinements that the Applicant has made to the plans since Council’s review of the October 2025 concept plan: A. The building façade elevations have been further refined with additional vertical articulation of the building to break up the height of the building, particularly along Green Bay Road. B. Elimination of the rooftop penthouses for the fourth-floor units, reducing to the building height from 62’-0” to 55’-3” (top of stair access). C. Elimination of a restaurant as a commercial tenant. D. An increase of 19 additional below-grade parking spaces for the residential units. VILLAGE STAFF REVIEW Village Staff has completed its review of the Applicant’s initial submittal of the preliminary plan application materials. The Applicant has not had an opportunity to respond to all of staff’s comments; however, staff has determined that the application materials were in such a condition that review by the DRB was appropriate. REQUIRED ZONING RELIEF Based upon staff’s review of the preliminary plan submitted to date, the following zoning relief has been identified: A. Approval of a Plat of Consolidation to create one Lot of Record. Page 12 Page 66 of 207 B. Map Amendment to rezone 1007-1011 Tower Court parcel and a portion of the 901-905 Green Bay Road parcel from D-Light Industrial to C-2 General Retail Commercial. C. Approval of a Planned Development for a mixed-use development, which includes consideration and approval of the following special uses and exceptions from the requirements of the Zoning Ordinance: a. The maximum building height allowed is 45 feet and 4 stories; the Applicant proposes a four- story building at the following height: i. Building (Top of Roof Access) – 55’-3” ii. Building (Top of Rooftop Mechanical Screening) – 53’-5” iii. Building (Top of Parapet) – 49’-8” b. The minimum ground floor height allowed is 14 feet; the Applicant proposes a ground floor height of 13 feet. c. No side yard is required, but when a side yard is provided it must be at least three feet; the Applicant proposes the building to be setback more than zero feet, but less than three feet from portions of the north property line. d. The minimum rear yard setback requirement is 10 feet; the Applicant proposes less than 10 feet along the east property line. e. A landscaped area at least 5 feet deep along the rear lot line is required; the Applicant is not proposing any landscaping along the rear lot line to accommodate parking spaces. f. The minimum required number of off-street parking spaces is 60; 28 spaces for the residential units and 32 spaces for the commercial uses. The Applicant proposes a total of 55 spaces; 46 below-grade spaces for the residential units and 9 ground-level spaces for guests and commercial tenant use. While the planned development ordinance can include these proposed spaces as a requirement, the developer will not be required to obtain approval of an exception to the existing Village requirement pursuant to the preemption provisions of the People Over Parking Act, which becomes effective June 1, 2026, for developments within a half mile radius of a rail transit station. g. The proposed parking located on street-level requires special use approval; and h. The interior design office (Rebel House Design) on the ground level requires special use approval as a portion of the use would be located within the Commercial Overlay District. Though the zoning relief is not the purview of the DRB, this information is provided so the DRB is aware of the relief the Planned Development Commission will be considering. CERTIFICATE OF APPROPRIATENESS CONSIDERATIONS As established by the Village Code, the Design Review Board is to consider the following four (4) factors in determining whether to grant a Certificate of Appropriateness: (1) whether the proposed external architectural features and site improvements are appropriate to and compatible with the character of the immediate neighborhood; (2) whether the proposed external architectural features and site improvements are appropriate to and compatible with adopted Village plans for and improvements in the immediate neighborhood, and including both urban design and site arrangement considerations (Note: Please refer to the early section “Property Description” in which the project consistency with the Comprehensive Plan is summarized). Page 13 Page 67 of 207 (3) whether the proposed external architectural features and site improvements are consistent with applicable Village design guidelines and such standards and criteria as may be adopted by the Board; and (4) the probable effect of the proposed external architectural features on the integrity of the immediate vicinity. The DRB will need to determine if the proposed mixed-use building and its associated hardscape and landscape comply with the above standards. DESIGN GUIDELINES The Village’s Design Guidelines provide direction for the style and form of new commercial and mixed- use buildings, as well as multi-family buildings. The Subject Property is located approximately mid-block in the Hubbard Woods District. The Design Guidelines provide the following overview of the district: The Hubbard Woods Business District is a linear business district built on both sides of a regional arterial roadway, Green Bay Road. It has a smaller building scale than the East/West Elm Street District, giving it a more intimate feel despite heavier traffic conditions. As with the Elm Street District, the Hubbard Woods District has a pedestrian-oriented, neighborhood retail character. The buildings exhibit architectural consistency, scale and storefront displays that encourage strolling and window shopping. A significant number of multiple-family residential units are located on the upper floors of the retail stores. An excerpt of the Village Design Guidelines is included as Attachment C, highlighting standards which apply to mixed-use buildings. The standards in the Guidelines address: I. Contextual Design II. Uses III. Historic Buildings and Building Elements IV. Styles V. Building Mass (setbacks, height, roof forms) VI. Proportion/Scale (horizontal rhythm, vertical rhythms, façade articulation, fenestration, hierarchy) VII. Articulation (entries, window and door fenestration, building lighting, building signage, accessibility, mechanical equipment) VIII. Materials IX. Services, Secondary Facades & Parking Structures RECOMMENDATION At the May 21, 2026, Design Review Board meeting, the DRB is scheduled to consider the design of the Applicant’s proposed building, signage, hardscape, and landscaping. After hearing from the Applicant and the public, the Board may decide to take action on one of two options: 1. Continue further review of the application to a date specific in order to provide the Applicant and/or staff additional time to address questions and comments from the DRB. 2. Adopt a motion recommending approval or a motion recommending denial of a certificate of appropriateness for design of the proposed mixed-use building. If the DRB wishes to adopt a motion recommending approval or denial, a DRB member may want to make a motion such as the following: Move to recommend approval [denial] of a certificate of appropriateness for the design of the Page 14 Page 68 of 207 proposed four-story mixed-use building on the Subject Property, subject to the following conditions: A. [If the DRB chooses to place conditions as part of its recommendation, it will want to include the conditions here.] The DRB’s recommendation is based on evidence in the record, or a public document, and upon the following findings of fact: (1) the proposed external architectural features and site improvements are appropriate to and compatible with the character of the immediate neighborhood; (2) the proposed external architectural features and site improvements are appropriate to and compatible with adopted Village plans for and improvements in the immediate neighborhood, and including both urban design and site arrangement considerations; (3) the proposed external architectural features and site improvements are consistent with applicable Village design guidelines and such standards and criteria as may be adopted by the Board; and (4) the probable effect of the proposed external architectural features on the integrity of the immediate vicinity. Staff and the Applicant will be present at the May 21, 2026, DRB meeting to present a summary of the application and to answer any questions. ATTACHMENTS Attachment A: Applicant’s Preliminary Planned Development Plan Application Materials Attachment B: October 21, 2025, Council Review of Concept Plan for the Subject Property Attachment C: Design Guidelines Excerpts Page 15 Page 69 of 207 ATTACHMENT A PD-P V I L L A G E O F W I N N E T K A, I L L I N O I S DEPARTMENT OF COMMUNITY DEVELOPMENT PLANNED DEVELOPMENT PRELIMINARY PLAN APPLICATION Prior to submitting this formal application, the matter must first be reviewed as a concept plan application by the Village Council. If the Council has not yet reviewed your concept plan application, please contact the Community Development Department to learn what is required. The following materials are the minimum required for the processing of a formal application by the Village of Winnetka’s Planned Development Commission and Village Council. A public hearing for an application will not be scheduled until all required materials have been submitted and revised as necessary to meet Code requirements, as determined by Village staff. If you have questions regarding the completion of this application please contact the Community Development Department at 847-716-3525. The initial submittal MUST contain: U U ■ 7 collated copies of complete sets of all application materials, including the application form, required attachments, and folded full size plat/plan sheets  1 electronic version (PDF) of ALL application materials (refer to application section regarding ■ instructions). U Applicant Information Primary Contact Person U Legal Name TODD ALTOUNIAN Name ANDERS RUSTIN MANAGER Company OKW ARCHITECTS Company TOWER COURT WINNETKA LLC Address 600 W JACKSON BLVD, SUITE 250 Address 919 SHERWOOD DR City, State, Zip CHICAGO, IL 60661 City, State, Zip LAKE BLUFF IL 60044 Phone No. 312-798-7710 Phone No. 847-875-7025 Email ARUSTIN@OKWARCHITECTS.COM Email TALTOUNIAN@ALTOUNIAN.COM Consultants (as applicable) U U U Attorney Architect/Planner Name CAROLINE SMITH Name ANDERS RUSTIN Company LATIMER LEVAY FYOCK Company OKW ARCHITECTS Address 55 W MONROE ST, SUITE 1100 Address 600 W JACKSON BLVD, SUITE 250 City, State, Zip CHICAGO IL 60603 City, State, Zip CHICAGO, IL 60661 Phone No. 312-422-8000 Phone No. 312-798-7710 Email csmith@llflegal.com Email ARUSTIN@OKWARCHITECTS.COM Civil Engineer U Other U Name TIM BROWN Name COLLEEN BARKLEY Company ERIKSSON ENGINEERING ASSOCIATES Company MARIANI LANDSCAPE Address 229 E WISCONSIN AVE., SUITE 1102 Address 300 ROCKLAND RD City, State, Zip MILWAUKEE, WI 53202 City, State, Zip LAKE BLUFF, IL 60044 Phone No. 414-245-2571 Phone No. 847-810-6800 Email TBROWN@EEA-LTD.COM Email CBARKLEY@MARIANILANDSCAPE.COM Page 70 of 207 Village of Winnetka PLANNED DEVELPOMENT – PRELIMINARY APPLICATION Property Information (if more than one parcel is involved in the request please include the information for all parcels) 901-913 GREEN BAY ROAD, 1007 - 1009 TOWER COURT ROAD Site Location/Address: 05-17-123-013, 019, 022, 023 Property Index Numbers: Size of Property: (square feet/acres) 29,405 SF / 0.675 ACRES Size of Building Space, if applicable: (square feet) 89,576 SF Current Comprehensive Plan Land Use Designation : COMMERCIAL AND MIXED-USE DEVELOPMENT F Current Zoning: C2 & D Current Use of the Property: RETAIL, RESIDENTIAL, OFFICE, AUTO SERVICE No: X 1 Is any portion of the property within the 100-year floodplain? Yes: Requested Action(s) (check all that are applicable):  Planned Development – Preliminary Plan ■  Amendment to Existing Planned Development Ord. No.  Comprehensive Plan Amendment  Rezoning from D ■ to C-2  Special Permit for 1) INTERIOR DESIGN OFFICE, 2) SPA USE, 3) PARKING ON GROUND LEVEL ■  Zoning Code Text Amendment  Zoning Exceptions (attach document listing and explaining exceptions)  Subdivision – Preliminary Plat  Subdivision Exceptions (attach document listing and explaining exceptions)  Other  Plat of Survey & Parcel Legal Description(s) ■ Attach the most recent plat of survey of the Subject Property, certified by a registered land surveyor, showing existing lot lines and dimensions, lot area, all easements, all public and private rights-of-way, and all streets across and adjacent to the subject property.  Conformity with Comprehensive Plan ■ Include a written statement explaining the conformity, or lack of conformity, of the approval being requested to the Village’s Comprehensive Plan Map. Where the approval being requested does not conform to the Comprehensive Plan, provide reasons justifying the requested approval. Page 2 of 9 Page 71 of 207 Village of Winnetka PLANNED DEVELPOMENT – PRELIMINARY APPLICATION Site Ownership and Control Current Property Owner Information U U Proposed Property Owner Information U U Legal Name: TOWER COURT WINNETKA LLC Legal Name: Primary Contact : TODD ALTOUNIAN Primary Contact : Address 919 SHERWOOD DR Address City, State, Zip LAKE BLUFF, IL 60044 City, State, Zip Phone No. 847-875-7025 Phone No. Email TALTOUNIAN@ALTOUNIAN.COM Email Attach a copy of a title policy and affidavit of ownership showing current ownership of the property. If property is held in a trust, also include a certified copy of the trust agreement or a simple affidavit (under oath before a notary) as to who are the beneficiaries of the trust. (Check which document(s) are attached): ❑ Affidavit of Ownership ❑ Title Policy or Title Commitment ❑ Certified Copy of Trust Agreement OR a simple Affidavit Identifying Trust Beneficiaries ❑ Complete Attachment A, listing all individuals/entities that have a beneficial interest in the legal entity that currently owns the property ❑ Complete Attachment B, listing all individuals/entities that have a beneficial interest in the legal entity that is proposed to own the property upon receiving necessary approvals. Applicants Involvement with the Property If the Applicant does not own the property, please also provide documentation showing the applicant’s interest in the property (Check which document is attached. The dollar amounts in documents may be blacked-out): ❑ Owner (see the previous box) ❑ Lease ❑ Real Estate Contract ❑ Other ❑ Complete Attachment C, listing all individuals/entities that have a beneficial interest in the legal entity that is the Applicant. Additional Required Attachment(s) 1B ❑ Planned Development Worksheet - Preliminary Plan ❑ If zoning or subdivision relief in addition to planned development preliminary plan approval and preliminary plat approval is requested, submit the appropriate application forms and materials. Filing Fees All applications require payment of a non-refundable fee, as well as additional funds that are held in escrow to off-set 4B anticipated recoverable expenses. Please attach a check with your application and indicate below the amount of the fee submitted. The escrow covers such items as staff & Village $ Amount of Non-Refundable Fee ($1,200) attorney time and public notice expenses. If these expenses exceed the initial escrow deposit, the $ Amount of Escrow ($2,500) applicant is responsible for reimbursing the Village for the additional fees. If the expenses are less $ Total Application Fee (Non-Refundable Fee plus Escrow) than the escrow deposit, the applicant will be issued a refund by the Village Page 3 of 9 Page 72 of 207 Page 73 of 207 Village of Winnetka PLANNED DEVELPOMENT – PRELIMINARY APPLICATION ATTACHMENT A: Current Property Owner – Beneficial Interest Please check which of the following describes the current property owner’s beneficial interest in the property and complete this sheet as instructed for each type of beneficial interest:  Corporation If current property owner is a corporation, please list the name and addresses of all officers and directors of the corporation and all shareholders who own individually or beneficially 5% or more of the stock of the corporation. In addition, this application must be accompanied by a resolution of the corporation authorizing the execution and submittal of this application.  Partnership ■ If current property owner is a partnership or an LLC, please list all partners, or LLC general and/or limited, with an individual or beneficial interest of 5% or greater.  Trust If current property owner is a trust, please provide the trust number ___________ and name and address of the Trustee ___________________________________ _________________________________________________________________, as well as list below the names and address of all beneficiaries of the Trust, together with their respective interests in the trust. The application shall be further verified by the current property owner in his capacity as trustee or by the beneficiary as a beneficial owner of an interest in the Trust and the application shall be signed individually by as many beneficiaries as are necessary to constitute greater than 50% ownership of the beneficial interest of the Trust Name: TODD ALTOUNIAN Name: PETER WITMER Address: 919 SHERWOOD DR Address: 919 SHERWOOD DR LAKE BLUFF IL 60044 LAKE BLUFF IL 60044 Ownership or Trust Interest: 50.00% % Ownership or Trust Interest: 50.00% % Name: Name: Address: Address: Ownership or Trust Interest: 0.00% % Ownership or Trust Interest: 0.00% % Name: Name: Address: Address: Ownership or Trust Interest: 0.00% % Ownership or Trust Interest: 0.00% % Page 5 of 9 Page 74 of 207 Village of Winnetka PLANNED DEVELPOMENT – PRELIMINARY APPLICATION ATTACHMENT B - Proposed Property Owner – Beneficial Interest Please check which of the following describes the proposed property owner’s beneficial interest in the property and complete this sheet as instructed for each type of beneficial interest:  Corporation If the proposed property owner is a corporation, please list the name and addresses of all officers and directors of the corporation and all shareholders who own individually or beneficially 5% or more of the stock of the corporation. In addition, this application must be accompanied by a resolution of the corporation authorizing the execution and submittal of this application.  Partnership If proposed property owner is a partnership or an LLC, please list all partners, or LLC general and/or limited, with an individual or beneficial interest of 5% or greater.  Trust If proposed property owner is a trust, please provide the trust number ___________________ and name and address of the Trustee ___________________________________ _________________________________________________________________, as well as list below the names and address of all beneficiaries of the Trust, together with their respective interests in the trust. The application shall be further verified by the proposed property owner in his capacity as trustee or by the beneficiary as a beneficial owner of an interest in the Trust and the application shall be signed individually by as many beneficiaries as are necessary to constitute greater than 50% ownership of the beneficial interest of the Trust Name: Name: Address: Address: Ownership or Trust Interest: 0.00% % Ownership or Trust Interest: 0.00% % Name: Name: Address: Address: Ownership or Trust Interest: 0.00% % Ownership or Trust Interest: 0.00% % Name: Name: Address: Address: Ownership or Trust Interest: 0.00% % Ownership or Trust Interest: 0.00% % Page 6 of 9 Page 75 of 207 Village of Winnetka PLANNED DEVELPOMENT – PRELIMINARY APPLICATION ATTACHMENT C - Applicant – Beneficial Interest Please check which of the following describes the beneficial interest in the legal entity that is the applicant and complete this sheet as instructed for each type of beneficial interest:  Corporation If applicant is a corporation, please list the name and addresses of all officers and directors of the corporation and all shareholders who own individually or beneficially 5% or more of the stock of the corporation. In addition, this application must be accompanied by a resolution of the corporation authorizing the execution and submittal of this application.  Partnership If applicant is a partnership or an LLC, please list all partners, general and/or or LLC limited, with an individual or beneficial interest of 5% or greater.  Trust If the applicant is a trust, please provide the trust number ___________________ and name and address of the Trustee ___________________________________ _________________________________________________________________, as well as list below the names and address of all beneficiaries of the Trust, together with their respective interests in the trust. The application shall be further verified by the applicant in his capacity as trustee or by the beneficiary as a beneficial owner of an interest in the Trust and the application shall be signed individually by as many beneficiaries as are necessary to constitute greater than 50% ownership of the beneficial interest of the Trust Name: TODD ALTOUNIAN Name: PETER WITMER Address: 919 SHERWOOD DR Address: 919 SHERWOOD DR LAKE BLUFF IL 60044 LAKE BLUFF IL 60044 Ownership or Trust Interest: 50.00% % Ownership or Trust Interest: 50.00% % Name: Name: Address: Address: Ownership or Trust Interest: 0.00% % Ownership or Trust Interest: 0.00% % Name: Name: Address: Address: Ownership or Trust Interest: 0.00% % Ownership or Trust Interest: 0.00% % Page 7 of 9 Page 76 of 207 TOWER COURT CONDOMINIUMS WINNETKA, ILLINOIS Project Summary — Mixed-Use Development Green Bay Road — Hubbard Woods Business District This application proposes the redevelopment of properties along Green Bay Road in the Hubbard Woods business district with a contextually designed mixed-use building that will replace a collection of aging structures with a high-quality development consistent with the character and scale of the surrounding area. The project is intended to strengthen the vitality of the business district while providing housing options that meet evolving community needs. Development Program The proposed building will include approximately 15,500 square feet of ground-floor commercial space with three stories of residential condominiums above, totaling 14 dwelling units. The building massing and design are intended to complement the established streetscape while enhancing pedestrian activity along Green Bay Road. Commercial Component The ground floor is planned to accommodate a mix of retail goods and personal service uses similar in nature to those that currently operate within the existing buildings on the site. Maintaining this type of tenancy will support continuity within the business district, provide convenient neighborhood-serving amenities, and reinforce the walkable character of the corridor. Residential Component The upper floors will contain 14 high-end luxury condominium residences ranging in size from approximately 2,200 square feet to 4,200 square feet. The residences are designed to address a growing demand among local residents seeking to remain in the community while transitioning from larger single-family homes that require greater maintenance and upkeep. Each unit will feature single-level living, eliminating internal stairs within the living space and allowing residents to age in place comfortably while maintaining a high level of design quality and functionality. The residences will be delivered as “white box” units, allowing purchasers to fully customize interior layouts, finishes, and design elements to meet their individual preferences and needs. This approach provides maximum flexibility for homeowners and ensures each residence reflects a high level of personalization and quality. The white box delivery model has been successfully implemented in comparable high-end residential developments in similar markets, demonstrating strong buyer interest and positive outcomes. TOWER COURT LLC IN TOWN LU XURY RESID ENCES 919 Sherwood Drive, Lake Bluff, Illinois 60044 847 234-5240 Page 77 of 207 Location and Accessibility The site is located within close proximity to neighborhood restaurants, retail establishments, and commuter rail service via Metra. This location supports a highly walkable environment and provides convenient access to daily services and regional transportation, reducing reliance on automobiles and supporting the continued vibrancy of the business district. Community Planning Benefits The proposed development advances several key planning objectives by: • Replacing underutilized and aging structures with a high-quality mixed-use building • Supporting the economic vitality of the Hubbard Woods business district through active ground-floor uses • Providing housing options that allow long-time residents to remain in the community • Enhancing walkability and supporting transit-oriented living patterns • Reinforcing the existing scale and character of the surrounding neighborhood Conclusion Overall, the proposed development represents a thoughtful reinvestment in the Hubbard Woods business district that balances economic vitality, appropriate density, and community character. By combining neighborhood-serving commercial uses with well-designed residential units, the project will contribute positively to the long-term sustainability and vibrancy of the area. TOWER COURT LLC IN TOWN LUX U RY RESID ENCES 919 Sherwood Drive, Lake Bluff, Illinois 60044 847 234-5240 Page 78 of 207 TOWER COURT WINNETKA LLC May 06, 2026 Re: Tower Court Winnetka 1011 Tower Court, Winnetka, IL 60093 PLANNED DEVELOPMENT STANDARDS, EXCEPTION STANDARDS & COMPENSATING BENEFITS In conjunction with the Tower Court Winnetka Planned Development application made by OKW Architects and Tower Court Winnetka LLC, the planned development shall comply with the below standards: Planned Development Standards: 1. The proposed development and the combination of uses furthers the goals and objectives of the Comprehensive Plan. Hubbard Woods is designated a Business District with the desire for Mixed-Use occupancies. The development includes generous ground floor retail, below-grade parking, and 3-stories of residences above to support community planning goals of strengthening and promoting walkable vibrant business districts and sustainable, transit supportive, livable neighborhoods. 2. The establishment, maintenance and operation of the planned development will not be detrimental to or endanger the public health, safety, health, comfort, morals or general welfare, or have a negative environmental impact on the neighborhood or Village. The proposed mix of uses are aligned with the Business District of Winnetka. All businesses will operate under normal hours. The building will conform to all Village codes and ordinances and have a positive impact on the safety and general welfare of the public. 3. The planned development will not unreasonably impede the use and enjoyment of other property in the immediate vicinity which are permitted by right in the district or districts of concern, nor unreasonably diminish or impair property values in the immediate vicinity. The proposed development is designed to enhance the use and enjoyment of other properties in the immediate vicinity by creating vibrant and attractive storefronts within the Business District. There is no evidence that the proposed development will impair property values and is more likely to increase the values of properties in the immediate vicinity. 4. The establishment of the planned development will not unreasonably impede the normal and orderly development or improvement of other property in the immediate vicinity for uses permitted by right in the district or districts of concern. The proposed development will not encroach or infringe on the public rights-of-way or any adjacent properties. All proposed uses will operate within the bounds of the site. 5. Adequate measures have been or will be taken to provide ingress and egress in a manner which minimizes pedestrian and vehicular traffic congestion in the public ways. The findings of KLOA’s Traffic Impact Study indicate “The traffic that will be generated 919 SHERWOOD DR. LAKE BLUFF ILLINOIS 60044 847.234.5240 Page 79 of 207 TOWER COURT WINNETKA LLC by the proposed development will have a limited impact on the operations of the study area intersections and no additional roadway improvements or signal modifications will be required.” and “Given the low projected traffic volumes turning into this proposed curb cut, the proposed curb cut will not have a negative impact on the flow of traffic along Green Bay Road.” 6. Adequate parking, utilities, access roads, drainage and other facilities necessary to the operation of the planned development exist or are to be provided. The findings of KLOA’s Traffic Impact Study indicate “The proposed number of residential parking spaces will meet/exceed the Village of Winnetka parking requirements and will accommodate the projected parking demand of the proposed development.” and “The parking demand by the retail component of the development will be accommodated via the proposed 10 off-street parking spaces and the surplus public parking available within the Hubbard Woods District.” The proposed development has been closely coordinated with Winnetka staff to ensure proper utilities, drainage, and other facilities are provided. 7. The planned development in all other respects conforms to the applicable regulations of this and other applicable Village ordinances and codes. Exceptions to Subdivision and District Regulations 1. The proposed exceptions will enhance the overall quality of the development, the design of the structures, and the site plan to further the goals and objectives of the Comprehensive Plan and the Design Guidelines. The development as designed proposes the highest and best use of the site and is designed to integrate thoughtfully with the surrounding context and enhance the overall quality of the Business District. The proposed exceptions are integral to achieving a design that will be vibrant, marketable, and appropriately parked. 2. The proposed exceptions will enable the development to offer environmental and pedestrian amenities available to all residents of the Village. As stated above, the proposed design and requested exceptions support community planning goals of strengthening and promoting walkable vibrant business districts and sustainable, transit supportive, livable neighborhoods. 3. The proposed exceptions will not cause an adverse impact on neighboring properties that outweigh the public benefits of the development. The exceptions are designed to step the building back thoughtfully so it remains contextual along Green Bay Road and Tower Court. 4. The proposed exceptions contain a proposed design and combination of uses, that will complement the character of the surrounding neighborhood. As stated above, Hubbard Woods is designated a Business District with the desire for Mixed-Use occupancies. The development includes generous ground floor retail, below-grade parking, and 3-stories of residences above, with an architectural design that fits the character of the surrounding neighborhood and aligns with the comprehensive plan. 5. The proposed exception will provide a public benefit to the Village, as described in Section 17.58.120.B of the Zoning Ordinance: page 2 of 3 Page 80 of 207 TOWER COURT WINNETKA LLC Compensating Benefits 1. Reinvestment in Underutilized Property Replacing underutilized and aging structures with a high-quality, thoughtfully designed mixed-use building that reflects the character and long-term vision of the district. Developments of this caliber and scale typically generate a substantial increase in taxable property value while placing a comparatively modest demand on municipal services. 2. Strengthening the Local Business District Supporting the economic vitality of the Hubbard Woods business district through active, pedestrian-oriented ground-floor uses that contribute to a vibrant streetscape. The project also prioritizes retaining and accommodating existing tenants—particularly those contributing to the area’s design-oriented identity—thereby preserving continuity while encouraging further investment and foot traffic. 3. Housing Continuity and Community Stability Providing high-quality housing options that enable long-time residents to remain within the community as their housing needs evolve. Buyers at this price point often demonstrate strong patterns of civic engagement, including philanthropic contributions, participation in local organizations, and volunteerism, reinforcing the social fabric of the neighborhood. 4. Walkability and Transit-Oriented Living Enhancing walkability and supporting transit-oriented development patterns by introducing approximately 12–15 households within convenient walking distance of local restaurants, retail, and services, as well as nearby transit access. This increased residential density supports local businesses, reduces reliance on automobiles, and aligns with broader sustainability and mobility goals. Sincerely, Peter Witmer Member Tower Court Winnetka LLC page 3 of 3 Page 81 of 207 TOWER COURT CONDOMINIUMS 1011 TOWER COURT WINNETKA, IL PD RESUBMISSION MAY 07, 2026 Page 82 of 207 DEVELOPMENT STANDARDS AMENDMENT REQUIRED - Re-zone Tower Court parcel and a portion of 901-905 Green Bay from D Light Industrial to C-2 General Retail Commercial AMENDMENT REQUIRED - Re-zone Tower Court parcel and a portion ofCurrent 901-905 Green Bay from D Light Industrial to C-2 General Retail Commercial 2026 PROPOSAL C-2 Zoning DEVELOPMENT SITE SIZE Current 0.68 acres 2026 0.68 acres PROPOSAL C-2 Zoning BUILDING GROSS FLOOR AREA DEVELOPMENT SITE SIZE 0.68 acres 0.68 acresSF RA EXCLUDING PARKING 71,086 IL R WITH PARKING BUILDING GROSS FLOOR AREA 89,715 SF RA OA RA IL DR EXCLUDING PARKING 71,086 SF ILR BER .O. RESIDENTIAL WITHGROSS FLOOR AREA PARKING 50,861 89,715 SFSF OA M W DR . COMMERCIAL GROSS FLOOR AREA GFA:15,862 50,861 SF SF .O. RESIDENTIAL GROSS FLOOR AREA EXCLUDING BOH: 4,363 SF W . COMMERCIAL GROSS FLOOR AREA GFA:15,862 SF BUILDING HEIGHT 45' - 0" 4-stories 49'-8" EXCLUDING BOH: w parapet 4,363 SF TOWER COURT EXCEPTION REQUIRED 4-stories 55'-3" at stair access BUILDING HEIGHT 45' - 0" 4-stories 49'-8" w parapet CONDOS TOWER COURT GROUND LEVEL FLOOR EXCEPTION TO FLOOR HEIGHT REQUIRED 4-stories 55'-3" at stair access EXCEPTION REQUIRED 14' - 0" MIN. 13' - 0" CONDOS GROUND LEVEL FLOOR TO FLOOR HEIGHT EXCEPTION REQUIRED 14' - 0" MIN. 13' - 0" Required Provided TO ON-SITE PARKING Required Provided TO WE Commercial 2 x 18,593 sf= WE RC ON-SITE PARKING Commercial 2 x37 spaces 18,593 sf= 9 spaces RC T. 2 spaces/1,000 sf 37 spaces 9 spaces T. Special Use Required: 2 spaces/1,000 sf Special Parking Use level. on streetRequired: 1.5 x 3 units= Parking on street level. Dwelling 1.5 5x spaces 3 units= Dwelling 5 spaces EXCEPTION REQUIRED: EXCEPTION 2 x 12 units= 46 spaces 10 parking spacesREQUIRED: for 15,749 sf of 2-BR - 1.5/unit 2 x2412spaces units= 46 spaces 10 parking spaces for 15,749 sf of 2-BR 3-BR--1.5/unit 2/unit commercial space. 3-BR - 2/unit 24 spaces commercial space. = 29 spaces GR GR = 29 spaces EE EE RESIDENTIAL USEUSE RESIDENTIAL TYPE - # of TYPE - #UNITS of UNITS N B N BA CONDOMINIUM UNITS 1515 AY Y RD RD . CONDOMINIUM UNITS RESIDENTIAL BEDROOM RESIDENTIAL SIZE - BEDROOM SIZE# -of# of UNITS UNITS . 2-bedroom 2-bedroom 3 3 3-bedroom 3-bedroom 1212 FRONT FRONT YARDYARD SETBACKS SETBACKS 00ft.ft.MIN MIN 33 ft. MAX 0 0ft.ft.MIN MIN1 ft. 2 in. 1 ft. MAX 2 in. MAX (along(along GreenGreen Bay Bay Rd.) Rd.) SIDE SIDE YARDYARD SETBACKS SETBACKS (along South property (along South property line)line) 00ft.ft.(3 (3 ft.)* ft.)* MIN MIN 2323ft.ft.1 in. MIN 1 in. 38 38 MIN ft.MAX ft.MAX (along North property line) EXCEPTION 0 ft. (3 ft.)* MIN 7 5/8 in. MIN 4 ft. 5 in. MAX (along North property line) EXCEPTION 0 ft. (3 ft.)* MIN 7 5/8 in. MIN 4 ft. 5 in. MAX REQUIRED REQUIRED REAR YARD SETBACKS REAR(along YARDTower SETBACKS 10 ft. MIN 6 in. MIN 17 ft. 4 in. MAX Ct.) EXCEPTION REQUIRED 10 ft. MIN 6 in. MIN 17 ft. 4 in. MAX (along Tower Ct.) EXCEPTION REQUIRED 4TH STORY SETBACK 10 ft. MIN 3 3/4 in. TOWER RD. 4TH (along STORYGreen SETBACK Bay Rd.) EXCEPTION REQUIRED (along Green Bay Rd.) EXCEPTION REQUIRED 10 ft. MIN 3 3/4 in. TOWER RD. * A side yard is not required, but where a side yard is provided, it must be a minimum of 3 feet. * A side yard is not required, but where a side yard is provided, it must be a minimum of 3 feet. TOWER COURT CONDOMINIUMS TOWER COURT OKW ARCHITECTS OKWW. Jackson, ARCHITECTS TOWER TOWERCOURT COURT TOWERCOURT TOWER COURTCONDOMINIUMS CONDOMINIUMS 01 2 600 Suite 250 WINNETKA LLC 01 OKW ARCHITECTS GREEN BAY RD. WINNETKA, IL 600 W. Jackson, Suite 250 Chicago, IL IL 60661 Architects 600 W. Jackson, Suite Chicago, Chicago, IL 60661 60661 250 WINNETKA LLC WINNETKA LLC GREEN 12/19/25 Project 1011 BAY Tower RD. WINNETKA, #: Court, 25057 IL Winnetka, IL Architects May 12/19/25 07, 2026 Project #: 25057 Project #: 25057 Page 83 of 207 SITE PLAN 150' - 0" METRA RAIL LINE PROPOSED 4 4-STORY BUILDING 150'-0" GREEN BAY RD RAMP TOWER CT 5 DN DRIVE AISLE (ONE WAY) 200'-0" EXISTING TRANSFORMER RAIL BERM TO WE R RD N TOWERCOURT TOWER COURTCONDOMINIUMS CONDOMINIUMS OKW ARCHITECTS TOWER TOWERCOURT COURT 3 02 OKW ARCHITECTS SCALE: 1" = 50' 600 W. Jackson, Suite 250 600 W. Jackson, Suite 250 Chicago,ILIL Chicago, 60661 60661 WINNETKA WINNETKALLC LLC GREEN BAY Court, 1011 Tower RD. WINNETKA, IL Winnetka, IL Architects 0 25' 50' May 12/19/25 07, 2026 Project #: 25057 Project #: 25057 PROJECT Page 84 of 207 TREE PROTECTION CONSTRUCTION NOTES: 1. CONTRACTORS SHALL BE REQUIRED TO HAVE ALL UTILITIES LOCATED AND MARKED AND/OR PAINTED BY A REPRESENTATIVE OF THE UTILITY COMPANY PRIOR TO THE START OF ANY WORK. TO LOCATE UTILITIES UNDERGROUND, PLEASE CALL: J.U.L.I.E. AT 1-800-892-0123. EX TREE TO REMAIN & BE PROTECTED 2. CONTRACTORS SHALL FAMILIARIZE THEMSELVES WITH THE LOCATIONS OF ALL BURIED UTILITIES IN AREAS OF WORK BEFORE STARTING OPERATIONS. CONTRACTORS SHALL BE LIABLE FOR THE COST OF REPAIRING OR REPLACING ANY BURIED CONDUITS, CABLES OR PIPING DAMAGED DURING THE INSTALLATION 300 Rockland Road | Lake Bluff, Illinois 60045 TREE PROTECTION OF THIS WORK. Phone: 847.234.2172 | Fax: 847.234.2754 FENCING. SEE DETAIL A 3. SIX FOOT HEIGHT CHAIN LINK FENCE IS TO BE ERECTED AROUND THE DRIPLINE OF www.marianilandscape.com SHEET L3.0 ALL EXISTING TREES TO REMAIN IN ACCORDANCE WITH THE WINNETKA ZONING ORDINANCE. PROPERTY LINE 4. A TREE REMOVAL PERMIT MUST BE OBTAINED FROM WINNETKA PRIOR TO ALL TREE REMOVAL ACTIVITY INVOLVING TREES 6" OF MORE DBH IN ACCORDANCE WITH WINNETKA ZONING ORDINANCE. CONSULTANTS: 5. TREES TO BE REMOVED MUST BE MARKED IN THE FIELD WITH RED PAINT OR FLAGS AND INSPECTED BY THE WINNETKA FORESTRY OFFICE PRIOR TO ANY TREES BEING PROPOSED NEW BUILDING OUTLINE REMOVED. 6. IF NECESSARY TO CONDUCT WORK OR DIGGING WITHIN THE ROOT ZONE OF TREES TO REMAIN, THE LANDSCAPE ARCHITECT MUST BE NOTIFIED AND ADDITIONAL PROTECTIVE MEASURES, SUCH AS ROOT PRUNING OR BRIDGING, MUST BE EMPLOYED BY A LICENSED TREE SERVICE. 7. PROTECT STRUCTURES, SIDEWALKS, PAVEMENTS AND UTILITIES TO REMAIN FROM DAMAGE CAUSED BY SETTLEMENT, LATERAL MOVEMENT, UNDERMINING, WASHOUTS AND OTHER HAZARDS CAUSED BY SITE IMPROVEMENT OPERATIONS. 8. CAREFULLY MAINTAIN PRESENT GRADE AT BASE OF ALL EXISTING TREES TO REMAIN. PREVENT ANY DISTURBANCE OF EXISTING TREES INCLUDING ROOT X ZONES. USE TREE PROTECTION BARRICADES WHERE INDICATED. PROTECT #1 EXISTING TREES TO REMAIN AGAINST UNNECESSARY CUTTING, BREAKING OR SKINNING OF ROOTS, BRUISING OF BARK OR SMOTHERING OF TREES. DRIVING, EX TREE TO BE REMOVED PARKING, DUMPING, STOCKPILING AND/OR STORAGE OF VEHICLES, EQUIPMENT, DUE TO CONSTRUCTION SUPPLIES, MATERIALS OR DEBRIS ON TOP THE ROOT ZONES AND/OR WITHIN THE DRIPLINE OF EXISTING TREES OR OTHER PLANT MATERIAL TO REMAIN IS STRICTLY PROHIBITED. 9. EXERCISE CAUTION WHEN WORKING AND DIGGING NEAR TREES LOCATED ON ADJACENT PROPERTY. 10. CONTRACTORS ARE REQUIRED TO MAINTAIN A CLEAN SITE. ALL MATERIALS SHALL BE KEPT NEAT AND ORDERLY. CONTRACTORS SHALL REMOVE GARBAGE, WASTE MATERIALS, SCRAP, AND SOIL DEBRIS FROM JOB-SITE ON A DAILY BASIS. CLIENT: WASTE MATERIALS SHALL BE DISPOSED IN AN ENVIRONMENTALLY RESPONSIBLE MANNER. CONTRACTORS ARE RESPONSIBLE FOR PORTABLE TOILETS AND DUMPSTERS, UNLESS OTHERWISE SPECIFIED BY MARIANI LANDSCAPE. 11. ALL WORK AND OPERATIONS SHALL COMPLY WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES AND ORDINANCES. X #2 12. TREE INVENTORY CONDUCTED BY MARIANI LANDSCAPE. 13. EXISTING TREES HAVE BEEN LOCATED WITH GIS COORDINATES. LOCATIONS ARE APPROXIMATE BUT ACCURATE. FIELD VERIFICATION IS RECOMMENDED PRIOR TO TOWER COURT CONDOMINIUMS REMOVAL ACTIVITY. 901-913 GREEN BAY ROAD & 1007-1011 TOWER COURT # Date: Description: By: 2026.03.03 Schematic Review EC 2026.03.23 Winnetka PD Review EC 2026.05.07 PD Submission EC X PROPOSED NEW BUILDING OUTLINE #3 PARKING GARAGE RAMP APPROX TREE DRIP LINE. FENCING TO EXTEND TO LIMITS OF TREE DRIP LINE. TOWER COURT MINIMUM 3' FENCE PROTECTION RADIUS FROM TREE TRUNK. X EXISTING TREE TO BE PROTECTED #4 MARIANI PLOT STAMP: J:\01 Projects\2026\Tower Court_260001\04 Construction\20260501_Tower Ct_CDs 6' CHAIN LINK FENCE WITH STEEL OR WOODEN POSTS SPACED NO MORE THAN 8' ON CENTER. USE SANDBAGS AS ANCHORS IF SITE CONDITIONS WARRANT. X This plan is conceptual; all dimensions are to be verified. Materials are represented #5 ONE-WAY STREET in their future condition in a more mature state. All designs and ideas contained in these drawings are not to be used as final construction documents by other than PROPOSED NEW EDGE OF PAVEMENT PROPOSED NEW EDGE OF PAVEMENT MARIANI ENTERPRISES, INC.Th ey a r e th e so le pr op er ty of MARIANI PROPERTY LINE ENTERPRISES, INC. and are not to be duplicated or put to bid without express written consent. Graphic representations are for illustrative purposes; field adjustments may be made during installation in keeping with the design intent. DESIGN: EC GREEN BAY ROAD DRAFTED: EC PROPERTY LINE X CHECKED: CB #6 N O R T H EXISTING ADJACENT BUILDING NOT FOR CONSTRUCTION SCALE: 1:10 APPROX TREE DRIP LINE. FENCING TO EXTEND TO LIMITS OF TREE DRIP LINE. MINIMUM 3' FENCE PROTECTION RADIUS FROM TREE TRUNK. EXISTING TREE TO BE 0 5' 10' 20' 30' PROTECTED 6' CHAIN LINK FENCE WITH STEEL OR WOODEN POSTS ISSUED DATE: 2026.02.24 SPACED NO MORE THAN 8' ON CENTER. USE SANDBAGS PROJECT NO: TC26001 AS ANCHORS IF SITE CONDITIONS WARRANT. MAINTAIN EXISTING ADJACENT GRADE AT TREE TREE PROTECTION FENCING PRESERVATION A TREE PROTECTION Scale: NTS L3.0 Page 85 of 207 GENERAL LANDSCAPE DESIGN NOTE: GENERAL CONSTRUCTION NOTES: FINAL LANDSCAPE AND FUTURE CROSSWALK LOCATIONS ARE SUBJECT TO 1. CONTRACTORS SHALL BE REQUIRED TO HAVE ALL UTILITIES LOCATED AND COORDINATION WITH THE VILLAGE OF WINNETKA'S COMPREHENSIVE HUBBARD WOODS MARKED AND/OR PAINTED BY A REPRESENTATIVE OF THE UTILITY COMPANY PRIOR STREETSCAPE IMPROVEMENT PLANS, CURRENTLY UNDER DEVELOPMENT BY OTHERS. TO THE START OF ANY WORK. TO LOCATE UTILITIES UNDERGROUND, PLEASE STREETSCAPE ENHANCEMENTS SHOWN ARE FOR REFERENCE AND OVERALL DESIGN CALL: J.U.L.I.E. AT 1-800-892-0123. INTENT. CROSSWALK IMPROVEMENTS HAVE BEEN OMITTED PER SUGGESTION BY 2. CONTRACTORS SHALL FAMILIARIZE THEMSELVES WITH THE LOCATIONS OF ALL VILLAGE OF WINNETKA STAFF. BURIED UTILITIES IN AREAS OF WORK BEFORE STARTING OPERATIONS. CONTRACTORS SHALL BE LIABLE FOR THE COST OF REPAIRING OR REPLACING ANY BURIED CONDUITS, CABLES OR PIPING DAMAGED DURING THE INSTALLATION 300 Rockland Road | Lake Bluff, Illinois 60045 OF THIS WORK. Phone: 847.234.2172 | Fax: 847.234.2754 3. REQUIRED LANDSCAPE MATERIAL SHALL SATISFY AMERICAN STANDARD FOR www.marianilandscape.com NURSERY STOCK (Z-60.2) STANDARDS AND BE STAKED, WRAPPED, WATERED AND MULCHED PER ORDINANCE. ALL TREES MUST BE SOURCED FROM A NURSERY WITHIN 100 MILES OF THE VILLAGE OF WINNETKA. 4. SIX FOOT HEIGHT CHAIN LINK FENCING OR OTHER RIGID MATERIAL IS TO BE ERECTED AROUND THE CONSTRUCTION SITE. FENCING SHALL ALSO INCLUDE AN OPAQUE SCREENING TO OBSCURE CONSTRUCTION ACTIVITIES AND CONTROL CONSULTANTS: CONSTRUCTION DUST. 5. PLANT QUANTITIES ON PLANT LIST INTENDED TO BE A GUIDE. ALL QUANTITIES BROOM FINISHED CONCRETE PAVING FOR SCORING PATTERN SEE LAYOUT PLAN SHEET L6.0. SEE NEIGHBORING BUILDING EGRESS TRANSFER SHALL BE CHECKED AND VERIFIED ON PLANTING PLAN. ANY DISCREPANCIES SHALL BE DISCUSSED WITH THE LANDSCAPE ARCHITECT. LIMITS OF STRUCTURAL SOIL CIVIL PLANS FOR CONSTRUCTION DETAILS AND SPECIFICATIONS SEE DETAIL E SHEET L8.0 6. ANY DEVIATIONS FROM OR MODIFICATIONS TO THIS PLAN SHALL BE APPROVED BY PROPERTY LINE THE LANDSCAPE ARCHITECT PRIOR TO INSTALLATION. 7. CONTRACTOR TO NOTIFY LANDSCAPE ARCHITECT UPON DELIVERY OF PLANT MATERIAL TO THE SITE. LANDSCAPE ARCHITECT RESERVES THE RIGHT TO REJECT ANY PLANT MATERIAL THAT DOESN'T MEET STANDARDS OR SPECIFICATIONS OF EGRESS CORRIDOR THE PROJECT. 1,512 SF 8. ALL PLANT MATERIAL TO BE INSTALLED PER THE PLANTING DETAILS PROVIDED ON THIS PLAN SET. 9. ALL BED EDGES TO BE WELL SHAPED, SPADE CUT, WITH LINES AND CURVES AS TRASH SHOWN ON THIS PLAN SET. 10. CU-STRUCTURAL SOIL® (OR APPROVED EQUIVALENT MEDIA) TO BE IN ALL STRUCTURAL SOIL AREAS: MIX OF CRUSHED LIMESTONE OR NON-LIMESTONE AGGREGATE, CLAY LOAM AND HYDRO-GEL STABILIZER THAT MEETS OR EXCEEDS COMPACTION SPECIFICATIONS FOR PAVEMENT BASE, YET ALLOWS TREE ROOTS TO DEVELOP FREELY THROUGH IT. REBEL HOUSE 11. ALL PLANTING BEDS TO BE PREPARED WITH MARIANI MIX BLENDED GARDEN SOIL. 2,375 SF 12. ALL FREESTANDING PLANTERS SHALL BE PREPARED WITH THE FOLLOWING: MARIANI MIX BLENDED GARDEN SOIL OR MIDWEST TRADING ALL PURPOSE CLIENT: BROOM FINISHED CONCRETE POTTING SOIL. PAVING. FOR SCORING PATTERN SEE LAYOUT PLAN 13. ALL SPECIFIED LANDSCAPE MATERIAL INDICATED ON THE CONSTRUCTION SHEET L6.0. SEE CIVIL PLANS DOCUMENTS WILL BE REQUIRED TO BE MAINTAINED THROUGHOUT THE LIFE OF FOR CONSTRUCTION DETAILS THE PROJECT AND MUST BE REPLACED SHOULD IT DIE OR BECOME DAMAGED. AND SPECIFICATIONS. SEE TOWER COURT ADDITIONAL DETAILS B-D 14. ALL PLANT MATERIAL SHALL HAVE A ONE YEAR GUARANTEE FROM SUBSTANTIAL SHEET L8.0. COMPLETION AS DETERMINED BY THE LANDSCAPE ARCHITECT, AND SHALL BE REPLACED SHOULD IT DIE WITHIN THAT PERIOD. 15. CONTRACTORS SHALL PROTECT STRUCTURES, SIDEWALKS, PAVEMENTS AND CONDOMINIUMS UTILITIES TO REMAIN FROM DAMAGE CAUSED BY SETTLEMENT, LATERAL STAIR MOVEMENT, UNDERMINING, WASHOUTS AND OTHER HAZARDS CAUSED BY SITE 901-913 GREEN BAY ROAD & IMPROVEMENT OPERATIONS. 1007-1011 TOWER COURT 185 SF COMMERCIAL 16. CAREFULLY MAINTAIN PRESENT GRADE AT BASE OF ALL EXISTING TREES TO 9,620 SF REMAIN. PREVENT ANY DISTURBANCE OF EXISTING TREES INCLUDING ROOT # Date: Description: By: STANDARD BRICK UNIT COMMERCIAL ZONES. USE TREE PROTECTION BARRICADES WHERE INDICATED. PROTECT 2026.03.03 Schematic Review EC PAVER CARRIAGE WALK SET ON CONCRETE. SEE DETAIL 1,548 SF UPPER DECK EXISTING TREES TO REMAIN AGAINST UNNECESSARY CUTTING, BREAKING OR SKINNING OF ROOTS, BRUISING OF BARK OR SMOTHERING OF TREES. DRIVING, 2026.03.23 Winnetka PD Review EC A SHEET L8.0. PARKING, DUMPING, STOCKPILING AND/OR STORAGE OF VEHICLES, EQUIPMENT, SUPPLIES, MATERIALS OR DEBRIS ON TOP THE ROOT ZONES AND/OR WITHIN THE 2026.05.07 PD Submission EC STANDARD 4'X6' PARKWAY DRIPLINE OF EXISTING TREES OR OTHER PLANT MATERIAL TO REMAIN IS STRICTLY TREE GRATE, TYP. PROHIBITED. SEE DETAILS E-G SHEET L8.0. ALL TREES IN GRATES SHALL ELEV 17. THE CONTRACTOR AT ALL TIMES SHALL KEEP THE PREMISES ON WHICH WORK IS BEING DONE, CLEAR OF RUBBISH AND DEBRIS. ALL PAVEMENT AND DEBRIS INCLUDE STRUCTURAL SOILS REMOVED FROM THE SITE SHALL BE DISPOSED OF LEGALLY PER VILLAGE STANDARDS. 18. ALL WORK AND OPERATIONS SHALL COMPLY WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES AND ORDINANCES. STANDARD BIKE RACK, TYP. 19. CONTRACTOR TO COORDINATE WITH THE VILLAGE FORESTER ON THE FINAL SEE DETAIL J SHEET L8.0 FINAL LOCATION TO BE STAIR SELECTION AND TAGGING OF AND PROPOSED PARKWAY TREES WITHIN THE ROW. COORDINATED WITH WINNETKA ENGINEERING DEPARTMENT 185 SF PARKING GARAGE 20. FINAL PLACEMENT OF PARKWAY TREES AND STREET PEDESTRIAN STREETLIGHTS TO BE COORDINATED WITH THE ENGINEERING DEPARTMENT PRIOR TO COMMERCIAL COMMERCIAL RAMP PLACEMENT. 1,473 SF 846 SF 21. ALL PARKWAY TREE LOCATIONS SHALL INCLUDE AN ELECTRICAL OUTLET FOR MAINTENANCE AND SEASONAL NEEDS. MARIANI PLOT STAMP: J:\01 Projects\2026\Tower Court_260001\04 Construction\20260501_Tower Ct_CDs TOWER COURT LIMITS OF STRUCTURAL SOIL CONDO ENTRY 550 SF FREESTANDING PLANTERS, SEE DETAIL E SHEET L8.0 MIXED SIZES SEE DETAILS C-E SHEET L6.1 PEDESTRIAN AND LANDSCAPE LIGHTING. SEE UTILITY & LIGHTING This plan is conceptual; all dimensions are to be verified. Materials are represented PLAN SHEET L9.0 in their future condition in a more mature state. All designs and ideas contained in PLANTING BED these drawings are not to be used as final construction documents by other than SEE L7.0 MARIANI ENTERPRISES, INC.Th ey a r e th e so le pr op er ty of MARIANI ENTERPRISES, INC. and are not to be duplicated or put to bid without express written consent. Graphic representations are for illustrative purposes; field DETECTABLE WARNING adjustments may be made during installation in keeping with the design intent. PLATES AT CROSSWALK FINAL LOCATION TO BE COORDINATED WITH DESIGN: EC WINNETKA ENGINEERING DEPARTMENT. SEE DETAIL K BROOM FINISHED CONCRETE PAVING BROOM FINISHED CONCRETE PAVING SHEET L8.0. SEE CIVIL PLANS DRAFTED: EC FOR SCORING PATTERN SEE LAYOUT SEE CIVIL PLANS FOR CONSTRUCTION FOR CONSTRUCTION DETAILS PARALLEL PARKING PLAN SHEET L6.0. SEE CIVIL PLANS DETAILS AND SPECIFICATIONS. SEE AND SPECIFICATIONS ONE-WAY STREET FOR CONSTRUCTION DETAILS AND ADDITIONAL DETAILS B-D SHEET L8.0. CHECKED: CB 14 SPACES SPECIFICATIONS. SEE ADDITIONAL N O R T H PROPERTY LINE NOT FOR CONSTRUCTION DETAILS B-D SHEET L8.0. NEW CONCRETE CURB & BROOM FINISHED CONCRETE SCALE: 1:10 WALK AT CORNER. SEE CIVIL PLANS FOR CONSTRUCTION DETAILS AND SPECIFICATIONS. SEE ADDITIONAL DETAILS B-D PLANTING BED GREEN BAY ROAD SHEET L8.0. SEE L7.0 0 5' 10' 20' 30' PROPERTY LINE ISSUED DATE: 2026.02.24 PROJECT NO: TC26001 EXISTING ADJACENT BUILDING MATERIALS PLAN L5.0 Page 86 of 207 GENERAL CONSTRUCTION NOTES: GENERAL LANDSCAPE DESIGN NOTE: 1. CONTRACTOR TO REFER TO CIVIL OR DESIGNATED GRADING PLAN FOR FINAL FINAL LANDSCAPE AND FUTURE CROSSWALK LOCATIONS ARE SUBJECT TO GRADES. COORDINATION WITH THE VILLAGE OF WINNETKA'S COMPREHENSIVE HUBBARD WOODS 2. PROVIDE NATURAL RUNOFF OF WATER WITHOUT LOW SPOTS. GRADES TO BE A STREETSCAPE IMPROVEMENT PLANS, CURRENTLY UNDER DEVELOPMENT BY OTHERS. MINIMUM OF 2% UNLESS OTHERWISE NOTED ON PLANS. STREETSCAPE ENHANCEMENTS SHOWN ARE FOR REFERENCE AND OVERALL DESIGN INTENT. CROSSWALK IMPROVEMENTS HAVE BEEN OMITTED PER SUGGESTION BY 3. CONTRACTOR TO ROUGH GRADE SITE 6" BELOW FINISHED GRADE FINISHING WITH VILLAGE OF WINNETKA STAFF. 4" OF NON-PULVERIZED TOPSOIL. LANDSCAPE CONTRACTOR TO FURNISH AND INSTALL 6" PULVERIZED TOP SOIL AT TURF AND WOODY PLANTING AREAS AND A COMBINATION OF 2" PULVERIZED TOP SOIL UNDER 4" OF ONE STEP HERBACEOUS 300 Rockland Road | Lake Bluff, Illinois 60045 PLANTING SOIL MIX AT ALL HERBACEOUS PLANTING AREAS. Phone: 847.234.2172 | Fax: 847.234.2754 4. GRADES NOT INDICATED SHALL BE UNIFORM AND SMOOTH BETWEEN POINTS www.marianilandscape.com WHERE ELEVATIONS ARE GIVEN AS NECESSARY BETWEEN ESTABLISHED PAVING AND CATCH BASINS. CONSULTANTS: NORTH SIDE EDGE OF CONCRETE WALK TO TERMINATE/ALIGN WITH EDGE OF DOOR LIMIT OF BRICK UNIT PAVERS AT PROPERTY LINE. GC TO COORDINATE NEIGHBORING BUILDING EGRESS TRANSFER EXISTING SIDEWALK ±11'-1" ±46'-10" VIF CUTTING TO PROPERTY LINE ACCOMMODATE LAYOUT ±5'-1034" EGRESS CORRIDOR ℄ 7'-0" 1,512 SF TREE GRATE TO BE ON CENTER WITH BUILDING CORNER DETAIL TRASH 35'-941" REBEL HOUSE 2,375 SF CLIENT: TREE GRATE TO BE ON CENTER WITH BUILDING DETAIL ℄ ℄ 6'-0" TOWER COURT 10'-1121" CONDOMINIUMS ℄ ℄ STAIR 901-913 GREEN BAY ROAD & 1007-1011 TOWER COURT 185 SF COMMERCIAL 10'-1121" 9,620 SF # Date: Description: By: COMMERCIAL TREE GRATE TO BE ON CENTER WITH BUILDING DETAIL 2026.03.03 Schematic Review EC ℄ ℄ 1,548 SF UPPER DECK 2026.03.23 Winnetka PD Review EC 6'-0" 2026.05.07 PD Submission EC 17'-734" ELEV ℄ ℄ LOCATE CENTER OF BIKE STAIR RACK 1'-6" FROM BACK OF 185 SF 17'-734" CONCRETE CURB, TYP. PARKING GARAGE COMMERCIAL COMMERCIAL RAMP 1,473 TREE GRATE TO BE ON SFWITH CENTER 846 SF MARIANI PLOT STAMP: J:\01 Projects\2026\Tower Court_260001\04 Construction\20260501_Tower Ct_CDs BUILDING CORNER DETAIL 6'-1041" ℄ 3'-0" CONCRETE PAVING JOINTING TO ALIGN w/ BUILDING FACADE CONDO ENTRY 10'-7" JOINTS, TYP. ℄ DETAILS, TYP. ℄ 550 SF 8" ℄ ℄ ℄ ℄ ℄ ℄ 3'-0" ℄ ℄ ±29'-1121" This plan is conceptual; all dimensions are to be verified. Materials are represented ±7'-1034" ±8'-1041" in their future condition in a more mature state. All designs and ideas contained in ±9'-841" ±8'-1041" ℄ ±7'-1134" ℄ 5'-0" these drawings are not to be used as final construction documents by other than FINAL LIGHT POLE MARIANI ENTERPRISES, INC.Th ey a r e th e so le pr op er ty of MARIANI ±15'-4" 8" ENTERPRISES, INC. and are not to be duplicated or put to bid without express LOCATION TO BE written consent. Graphic representations are for illustrative purposes; field COORDINATED WITH adjustments may be made during installation in keeping with the design intent. WINNETKA ENGINEERING 10'-721" 15'-1041" DEPARTMENT 11'-841" 16'-5" 22'-1141" 15'-10" 20'-321" 17'-221" 3'-834" DESIGN: EC 4'-0" DRAFTED: EC SEE CIVIL PLANS PARALLEL PARKING ONE-WAY STREET CHECKED: CB FOR PROPOSED 14 SPACES N O R T H PROPERTY LINE NOT FOR CONSTRUCTION SCALE: 1:10 STREET LAYOUT GREEN BAY ROAD 0 5' 10' 20' 30' PROPERTY LINE ISSUED DATE: 2026.02.24 PROJECT NO: TC26001 EXISTING ADJACENT BUILDING LAYOUT ℄ ℄ ℄ ℄ ℄ PLAN L6.0 Page 87 of 207 ℄ ℄ ℄ 550 SF ℄ ℄ 1'-534" ℄ 941" 1'-3" 1'-521" 1'-534" 1'-0" 1'-0" 10" 1'-821" 1'-6" 6'-0" 14'-521" 6'-0" ℄ 6'-0" 6'-0" 6'-0" 6'-0" 6'-0" 6'-0" 6'-0" 1'-6" ℄ 300 Rockland Road | Lake Bluff, Illinois 60045 Phone: 847.234.2172 | Fax: 847.234.2754 4'-821" www.marianilandscape.com 2'-221" 2'-221" 2'-221" 2'-221" 3'-821" 4'-834" 30"HT CONSULTANTS: 9'-1141" 2'-734" 9'-11" 2'-734" L6.1 MATCH LINE A L6.1 MATCH LINE B 1021" 1021" 5'-6" PLANTER 'A' (2) DOWNTOWN PLANTER 'B' (2) DOWNTOWN PLANTER 'C' (9) WILSHIRE PLANTER 'A' (2) DOWNTOWN PLANTERS 24" Ø x 30" HT. FINAL PLANTERS 36" Ø x 24" HT. PLANTERS 72" x 30" x 24" HT. PLANTERS 24" Ø x 30" HT. COLOR AND FINISH TBD FINAL COLOR AND FINISH TBD FINAL COLOR AND FINISH TBD FINAL COLOR AND FINISH TBD SOUTH FACADE PLANTER LAYOUT A 1/4" = 1'-0" ℄ ℄ ℄ 3'-0" 2" 2'-8" 1" CLIENT: D 1'-1121" 1.5" 1'-8" D 1.5" 2'-0" DETAIL 'D' 2'-334" TOWER COURT DETAIL 'D' 4'-8" 2'-6" 1'-6" 30"HT 18"HT 30"HT 24" Ø x 30" HT TOURNESOL LIGHTWEIGHT GFCR CONCRETE PLANTER WITH 26" Ø x 24" HT TOURNESOL CONDOMINIUMS PLANTER 'A' (2) DOWNTOWN 1'-121" LIGHTWEIGHT GFCR 10'-1141" 18"HT PLANTERS. FINAL COLOR DRAINAGE HOLES CONCRETE PLANTER WITH 901-913 GREEN BAY ROAD & SECTION 'C' COLOR AND FINISH TBD AND FINISH TBD DRAINAGE HOLES 1007-1011 TOWER COURT 18"-30" 2'-734" C C COLOR AND FINISH TBD L6.1 MATCH LINE A L6.1 MATCH LINE B (2) @ 24" Ø x 18" HT 2'-0" SEE LAYOUT (2) @ 24" Ø x 30" HT # Date: Description: By: 3'-0" 2'-8" C C 1'-8" 2026.03.03 Schematic Review EC 2'-0" 2026.03.23 Winnetka PD Review EC 1'-6" 1'-121" PLAN 2026.05.07 PD Submission EC ELEVATION PLAN ELEVATION SOUTH FACADE PLANTER LAYOUT PLANTER 'A': TOURNESOL DOWNTOWN PLANTER PLANTER 'B': TOURNESOL DOWNTOWN PLANTER B 1/4" = 1'-0" C 1/2" = 1'-0" D 1/2" = 1'-0" EMBEDDED REINFORCEMENT (SUPPORT FOR SIDE WALLS) 6'-0" NUMBER AND PLACEMENT VARIES 5'-7" MARIANI PLOT STAMP: J:\01 Projects\2026\Tower Court_260001\04 Construction\20260501_Tower Ct_CDs C D 2.5" 2'-1" 2'-6" 2.5" DETAIL 'D' PLAN C SECTION 'C' This plan is conceptual; all dimensions are to be verified. Materials are represented in their future condition in a more mature state. All designs and ideas contained in these drawings are not to be used as final construction documents by other than MARIANI ENTERPRISES, INC.They ar e the sole pr oper ty of MARIANI 72" x 30" x 24" HT ENTERPRISES, INC. and are not to be duplicated or put to bid without express written consent. Graphic representations are for illustrative purposes; field TOURNESOL LIGHTWEIGHT adjustments may be made during installation in keeping with the design intent. GFCR CONCRETE PLANTER WITH DRAINAGE HOLE COLOR AND FINISH TBD DESIGN: EC 2'-6" DRAFTED: EC CHECKED: CB ELEVATION ELEVATION N O R T H NOT FOR CONSTRUCTION SCALE: 1:10 PLANTER 'C': TOURNESOL WILSHIRE PLANTER E 1/2" = 1'-0" 0 5' 10' 20' 30' ISSUED DATE: 2026.02.24 PROJECT NO: TC26001 PLANTER LAYOUT PLAN L6.1 Page 88 of 207 PLANTING CONSTRUCTION NOTES: SHADE & ORNAMENTAL TREES: 1. SEE L5.0 GENERAL CONSTRUCTION DETAILS FOR ADDITIONAL SPECIFICATIONS. · ALL TREE TO MEET AMERICAN STANDARD FOR NURSERY STOCK (Z-60.2) STANDARDS. 2. VERIFY ALL UNDERGROUND UTILITIES AND GRADES PRIOR TO BEGINNING WORK. NOTIFY LANDSCAPE ARCHITECT OF ANY DISCREPANCIES PRIOR TO · REMOVE ENOUGH WHOLE BRANCHES, NOT JUST END INSTALLATION. TIPS TO REDUCE CROWN BY 1/5 TO 1/4 WOODY SHRUBS: 3. GENERAL CONTRACTOR SHALL NOT BE RESPONSIBLE FOR 'PRIVATE UTILITIES' · REMOVE 'V' CROTCHES, STUBS, DOUBLE LEADERS AND OVERLAPPING/RUBBING BRANCHES · PRUNE PLANTS AFTER PLANTING UNLESS ACCURATE 'AS-BUILT' DRAWINGS ARE SUPPLIED PRIOR TO THE COMMENCEMENT OF WORK. IT IS THE CONTRACTOR'S RESPONSIBILITY TO · PRUNE PLANTS AFTER PLANTING · PLANTS TO BEAR SAME RELATIONSHIP TO CONTACT THE OWNER'S REPRESENTATIVE FOR THIS INFORMATION PRIOR TO GRADE AS IN NURSERY · PLANTS TO BEAR SAME RELATIONSHIP TO GRADE AS IN · WATER IMMEDIATELY AFTER PLANTING 300 Rockland Road | Lake Bluff, Illinois 60045 ANY CONSTRUCTION EFFORTS. NURSERY UNTIL GROUND IS SATURATED Phone: 847.234.2172 | Fax: 847.234.2754 4. GENERAL CONTRACTOR SHALL NOT STORE MATERIALS, EQUIPMENT, PORTABLE · WATER IMMEDIATELY AFTER PLANTING UNTIL GROUND · DEPTH OF SOIL IS TO BE APPROPRIATELY www.marianilandscape.com TOILET, EXTRA FENCE PANELS, ETC. WITHIN PROTECTION ZONE OF EXISTING DETERMINED BY ROOTBALL SIZE, REMOVED IS SATURATED TREES AND VEGETATION ON SITE. FROM PLANT PIT AND IS TO BE AMENDED · WRAP TRUNK TO SECOND BRANCHES IN THE FALL AND USED AS BACKFILL 5. GENERAL CONTRACTOR IS RESPONSIBLE TO PREVENT DAMAGE TO EXISTING · 2" LAYER OF FINELY SHREDDED BARK PAVEMENT AND/OR STRUCTURES DURING EXCAVATION AND PLANTING. ANY · REMOVE WIRE BASKETS AT TOP OF BALL MULCH (2" LEAF MULCH NEAR BUILDING EQ PERENNIALS & GROUNDCOVER: SUCH DAMAGE SHALL BE REPAIRED BY CONTRACTOR AT NO ADDITIONAL COST · ALL NON-BIODEGRADABLE ROPE SHOULD BE CUT AND AND WHERE PERENNIALS & GROUNDCOVER TO THE CLIENT. REMOVED ARE INTERMIXED WITH SHRUB MASSES) CONSULTANTS: · REMOVE WIRE BASKETS AT TOP OF BALL · 4" LAYER OF PREPARED/AMENDED PLANTING 6. GENERAL CONTRACTOR IS TO REPORT ANY SOIL OR DRAINAGE PROBLEMS TO · DEPTH OF SOIL IS TO BE APPROPRIATELY DETERMINED SOIL MIX · ALL NON-BIODEGRADABLE ROPE SHOULD THE LANDSCAPE ARCHITECT. BY ROOTBALL SIZE, REMOVED FROM PLANT PIT AND IS · PLANTING SOIL MIX LAYER WILL BE HEAVILY BE CUT AND REMOVED TO BE AMENDED AND USED AS BACKFILL ROTOTILLED · LEAVE BURLAP ON BALL FOR INCREASED 7. CONTRACTOR TO OBTAIN ANY NECESSARY TREE REMOVAL PERMIT. EQ · SPACING VARIES BETWEEN VARIETIES (SEE · 2" LAYER OF FINELY SHREDDED BARK MULCH WITH ROOT STABILITY PLANTING PLAN) RAISED 3" SAUCER LIP (2" LEAF MULCH NEAR BUILDING · PLANT PERENNIAL AND GROUNDCOVER, AND WHERE PERENNIALS & GROUNDCOVER ARE WOODY SHRUB, SEE L7.0 PLANTING EQ PROPERTY LINE TAMP DOWN SOIL AROUND POT SO POT INTERMIXED WITH SHRUB MASSES) PLAN FOR SPECIES AND SPACING EQ TRIANGULAR SPACING DOES NOT HEAVE IN FROST 1'-121" · BURLAP TO BE REMOVED FROM THE TOP OF THE BALL SHREDDED HARDWOOD BARK MULCH SEE L7.0 PLANTING PLAN FOR · SCARIFY EXISTING SOIL LAYER TO HALF WAY DOWN 2" MIN DEPTH. NO BARK TO BE PLACED PLANT SPACING · WATER IN BEFORE APPLYING 2" LEAF MULCH 4"-6" BED AMENDMENT AGAINST BASE OF TREE TRUNK. · DO NOT OVER COVER FOLIAGE WITH MULCH · REMOVE WIRE BASKETS AT TOP OF BALL · ALL NON-BIODEGRADABLE ROPE SHOULD BE CUT AND 1" RAISED SAUCER LIP AROUND PLANT REMOVED PIT, TAPER TO MEET ADJACENT (1) 3" STREETSIDE FINISHED GRADE 2" LEAF MULCH MAPLE ('JFS Shichtel2'), 18" MIN. 18" MIN. TYP. 3" RAISED SAUCER LIP AROUND PLANT PIT, 18'-121" TYP, BACKFILL SOIL MIX, 24" MIN PERENNIAL TAPER TO MEET ADJACENT FINISHED GRADE 2'-0" DEPTH SHREDDED HARDWOOD BARK MULCH 2" MIN SCARIFY AND LOOSEN EDGES OF DEPTH. NO BARK TO BE PLACED AGAINST PLANT PIT TO ENCOURAGE NEW ROOT 3'-0" GROWTH PENETRATION. GROUNDCOVER BASE OF TREE TRUNK. 35'-941" TYP, BACKFILL SOIL MIX, 36" MIN DEPTH 4" BED PREPARATION (BARK FINES, COMPOST,PULVERIZED SCARIFY AND LOOSEN EDGES OF PLANT PIT TOPSOIL) TO ENCOURAGE NEW ROOT GROWTH PENETRATION. CLIENT: 17'-734" TYP TREE PLANTING TYP WOODY SHRUB PLANTING TYP PERENNIAL AND GROUNDCVOER PLANTING A 3/4" = 1'-0" B 3/4" = 1'-0" C 3/4" = 1'-0" (1) 3" STREETSIDE TOWER COURT MAPLE ('JFS Shichtel2'), TYP. (6) QT AUTUMN MOOR GRASS CONDOMINIUMS (1) #7 DWARF KOREAN (6) QT AUTUMN MOOR GRASS 21'-11" A D A 901-913 GREEN BAY ROAD & LILAC ANNUAL MIX - TBD (4) #1 LADY'S MANTLE 1007-1011 TOWER COURT (3) 3# BOBO HYDRANGEA PLANTER 'A' SEE L6.1 PLANTER 'B' D D # Date: Description: By: SEE L6.1 (3) #1 STELLA DE ORO DAYLILY A 2026.03.03 Schematic Review EC A (3) #1 MILLENNIUM ALLIUM 2026.03.23 Winnetka PD Review EC PLANTER 'C' SEE L6.1 2026.05.07 PD Submission EC (1) 3" STREETSIDE MAPLE ('JFS Shichtel2'), TYP. 17'-734" TYP PLANTER 'A' PLANTING TYP PLANTER 'B' PLANTING TYP PLANTER 'C' PLANTING D 1/2" = 1'-0" E 1/2" = 1'-0" F 1/2" = 1'-0" 35'-541" 17'-934" PARKING GARAGE RAMP MARIANI PLOT STAMP: J:\01 Projects\2026\Tower Court_260001\04 Construction\20260501_Tower Ct_CDs (1) 3" STREETSIDE F D MAPLE ('JFS Shichtel2'), 12'-521" (1) 7# DWARF KOREAN LILAC W/ TYP. L7.0 L7.0 PERENNIALS AT EA PLANTER SEE DETAIL E SHEET L7.0 This plan is conceptual; all dimensions are to be verified. Materials are represented in their future condition in a more mature state. All designs and ideas contained in these drawings are not to be used as final construction documents by other than MARIANI ENTERPRISES, INC.Th ey a r e th e so le pr op er ty of MARIANI ENTERPRISES, INC. and are not to be duplicated or put to bid without express written consent. Graphic representations are for illustrative purposes; field adjustments may be made during installation in keeping with the design intent. (3) 3" WHITESPIRE BIRCH ANNUAL MIX AT EA (1) #7 DWARF KOREAN LILAC W/ ANNUAL MIX AT SINGLE STEM SPECIMEN SM PLANTER PERENNIALS AT EA PLANTER EA SM PLANTER DESIGN: EC (3) 3# BOBO HYDRANGEA W/ SEE DETAIL E SHEET L7.0 (7) 3# LITTLE QUICK FIRE MIXED PERENNIALS, TYP. (7) 3# DWARF BUSH LIRIOPE GROUNDCOVER, HYDRANGEA SEE DETAIL F SHEET L7.0 HONEYSUCKLE TYP DRAFTED: EC (1) 3" PRAIRIE SENTINEL (1) 3" PRAIRIE SENTINEL (7) 3# DWARF BUSH (7) 3# DWARF BUSH (1) 3" PRAIRIE (10) 3# LOWSCAPE BLACK ONE-WAY STREET HACKBERRY HACKBERRY HONEYSUCKLE HONEYSUCKLE SENTINEL HACKBERRY CHECKED: CB CHOCKBERRY (7) 3# DWARF BUSH (7) 3# DWARF BUSH (7) 3# DWARF BUSH N O R T H PROPERTY LINE (7) 3# DWARF BUSH NOT FOR CONSTRUCTION GROUNDCOVER & (1) 3" PRAIRIE (1) 3" PRAIRIE HONEYSUCKLE HONEYSUCKLE HONEYSUCKLE SENTINEL HACKBERRY SENTINEL HACKBERRY HONEYSUCKLE PERENNIAL MIX SCALE: 1:10 (1) 3" PRAIRIE SENTINEL (1) 3" PRAIRIE SENTINEL (5) #3 DWARF BUSH HACKBERRY HACKBERRY HONEYSUCKLE GREEN BAY ROAD 0 5' 10' 20' 30' PROPERTY LINE ISSUED DATE: 2026.02.24 PROJECT NO: TC26001 EXISTING ADJACENT BUILDING 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" PLANTING PLAN L7.0 Page 89 of 207 LANDSCAPE MAINTENANCE SPECIFICATIONS: SPRING CLEANUP: 6. PRUNE BRANCHING SPECIES TO INCREASE DENSITY. CUT ONLY THE FLOWERING STEMS AFTER BLOOMING. DO NOT REMOVE THE FOLIAGE THE CONTRACTOR SHALL PROVIDE AS A SEPARATE BID, MAINTENANCE FOR A PERIOD OF 1 YEAR AFTER FINAL · PLANT BEDS SHALL RECEIVE A GENERAL CLEANUP BEFORE FERTILIZING AND MULCHING. CLEANUP INCLUDES ACCEPTANCE OF THE PROJECT LANDSCAPING. THE CONTRACTOR MUST BE ABLE TO PROVIDE CONTINUED REMOVING DEBRIS AND TRASH FROM BEDS AND CUTTING BACK HERBACEOUS PERENNIALS LEFT STANDING · THE FOLLOWING FALL CUT BACK DETERIORATING PLANT PARTS UNLESS INSTRUCTED TO RETAIN FOR WINTER MAINTENANCE IF REQUESTED BY THE OWNER OR PROVIDE THE NAME OF A REPUTABLE LANDSCAPE CONTRACTOR WHO THROUGH WINTER, E.G. ORNAMENTAL GRASSES, SEDUM AUTUMN JOY. INTEREST, E.G. SEDUM AUTUMN JOY AND ORNAMENTAL GRASSES. CAN PROVIDE MAINTENANCE. FERTILIZING: · LONG TERM CARE: STANDARDS: 1. DIVIDE PLANTS THAT OVERCROWD THE SPACE PROVIDED. DIVIDE ACCORDING TO THE SPECIES. SOME NEED · FOR TREES. THE RATE OF FERTILIZATION DEPENDS ON THE TREE SPECIES, TREE VIGOR, AREA AVAILABLE FOR FREQUENT DIVIDING, E.G. ASTERS AND YARROW EVERY TWO YEARS; OTHER RARELY, IF EVER, E.G. PEONIES, · ALL LANDSCAPE MAINTENANCE SERVICES SHALL BE PERFORMED BY TRAINED PERSONNEL USING CURRENT, FERTILIZATION, AND GROWTH STAGE OF THE TREE. MATURE SPECIMENS BENEFIT FROM FERTILIZATION EVERY 3 TO ACCEPTABLE HORTICULTURAL PRACTICES 4 YEARS; YOUNGER TREES SHALL BE FERTILIZED MORE OFTEN DURING RAPID GROWTH STAGES HOSTAS, AND ASTILBE. 2. FOR DETAILED INFORMATION REGARDING THE CARE OF SPECIFIC PERENNIALS, REFER TO ALL ABOUT 300 Rockland Road | Lake Bluff, Illinois 60045 · ALL WORK SHALL BE PERFORMED IN A MANNER THAT MAINTAINS THE ORIGINAL INTENT OF THE LANDSCAPE DESIGN. · THE CURRENT RECOMMENDATION IS BASED ON THE RATE OF 1000 SQUARE FEET OF AREA UNDER THE TREE TO BE PERENNIALS BY ORTHO; PERENNIALS: HOW TO SELECT, GROW AND ENJOY BY PAMELA HARPER AND Phone: 847.234.2172 | Fax: 847.234.2754 FERTILIZED. FOR DECIDUOUS TREES, 2 TO 6 POUNDS OF NITROGEN PER 1000 SQUARE FEET; FOR FREDERICK MCGOUTY, HP BOOKS PUBLISHER; HERBACEOUS PERENNIAL PLANTS: A TREATISE ON THEIR · ALL CHEMICAL APPLICATIONS SHALL BE PERFORMED IN ACCORDANCE WITH CURRENT COUNTY, STATE AND IDENTIFICATION, CULTURE AND GARDEN ATTRIBUTES BY ALLAN ARMITAGE, STIPES PUB LLC. www.marianilandscape.com FEDERAL LAWS, USING EPA REGISTERED MATERIALS AND METHODS OF APPLICATION. THESE APPLICATIONS SHALL · NARROW-LEAF EVERGREENS, 1 TO 4 POUNDS OF NITROGEN PER 1000 SQUARE FEET; FOR BROADLEAF BE PERFORMED UNDER THE SUPERVISION OF A LICENSED CERTIFIED APPLICATOR EVERGREENS, 1 TO 3 POUNDS OF NITROGEN PER 1000 SQUARE FEET. APPROVALS: · SHRUBS AND GROUNDCOVER SHALL BE TOP-DRESSED WITH COMPOST 1" DEEP OR FERTILIZED ONCE IN MARCH SUMMARY OF MAINTENANCE: WITH 10-6-4 ANALYSIS FERTILIZER AT THE RATE OF 3 POUNDS PER 100 SQUARE FEET OF BED AREA. · ANY WORK PERFORMED IN ADDITION TO THAT WHICH IS OUTLINED IN THE CONTRACT SHALL ONLY BE DONE UPON TURF MAINTENANCE: WRITTEN APPROVAL BY THE OWNER'S REPRESENTATIVE. · ERICACEOUS MATERIAL SHALL BE FERTILIZED WITH AN ERICACEOUS FERTILIZER AT THE MANUFACTURER'S 1. SOIL ANALYSIS PERFORMED ANNUALLY TO DETERMINE PH IF PH DOES NOT FALL WITHIN SPECIFIED RANGE, CONSULTANTS: RECOMMENDATION RATE IF PLANTS ARE GROWING POORLY, A SOIL SAMPLE SHOULD BE TAKEN · ALL SEASONAL COLOR SELECTIONS SHALL BE APPROVED BY THE OWNER'S REPRESENTATIVE PRIOR TO ORDERING ADJUST ACCORDING TO SOIL TEST RECOMMENDATIONS AND INSTALLATION MULCHING: 2. MAINTAIN PROPER FERTILITY AND PH LEVELS OF THE SOIL TO PROVIDE AN ENVIRONMENT CONDUCIVE TO SOIL TESTING: · ANNUALLY, ALL TREE AND SHRUB BEDS WILL BE PREPARED AND MULCHED, TO A MINIMUM DEPTH OF 3ff WITH TURF VITALITY FOR TURF GRASSES. QUALITY MULCH TO MATCH EXISTING. BED PREPARATION SHALL INCLUDE REMOVING ALL WEEDS, CLEANING UP SAID 3. MOW TURF ON A REGULAR BASIS AND AS SEASON AND WEATHER DICTATES. REMOVE NO MORE THAN THE TOP · THE MAINTENANCE CONTRACTOR SHALL PERFORM SOIL TESTS AS NEEDED TO IDENTIFY ANY IMBALANCES OR BED, EDGING AND CULTIVATING DECAYED MULCH INTO THE SOIL. DEBRIS FROM EDGING IS TO BE REMOVED FROM 1/3 OF LEAF BLADE. CLIPPINGS ON PAVED AND BED AREAS TO BE REMOVED. DEFICIENCIES CAUSING PLANT MATERIAL DECLINE. THE OWNER SHALL BE NOTIFIED OF THE RECOMMENDATION FOR BEDS WHERE APPLICABLE. IF DEEMED NECESSARY, A PRE-EMERGENT HERBICIDE MAY BE APPLIED TO THE SOIL TO 4. AERATE WARM SEASON TURF AREAS TO MAINTAIN HIGH STANDARDS OF TURF APPEARANCE, APPROVAL, AND THE NECESSARY CORRECTIONS MADE AT AN ADDITIONAL COST TO THE OWN ER. INHIBIT THE GROWTH OF FUTURE WEEDS. 5. APPLY PRE-EMERGENT TO TURF IN TWO APPLICATIONS IN EARLY FEBRUARY AND EARLY APRIL TO EXTEND · ACCEPTABLE TEST RESULTS BARRIER. · ORGANICALLY MAINTAINED GARDENS SHALL NOT RECEIVE ANY PRE-EMERGENT HERBICIDES. MULCH IN EXCESS OF LANDSCAPE TREES & SHRUBS 4" WILL BE REMOVED FROM THE BED AREAS. SPECIAL CARE SHALL BE TAKEN IN THE MULCHING OPERATION NOT TO 6. APPLY POST EMERGENT AS NEEDED TO CONTROL WEEDS. PH RANGE 5.0-7.0 OVER-MULCH OR COVER THE BASE OF TREES AND SHRUBS. THIS CAN BE DETRIMENTAL TO THE HEALTH OF THE 7. MECHANICALLY EDGE CURBS AND WALKS. ORGANIC MATTER >1.5% PLANTS. 8. APPLY NON-SELECTIVE HERBICIDE TO MULCHED BED AREAS AND PAVEMENT AND REMOVE EXCESS RUNNERS MAGNESIUM (MG) 100+ LBS/ACRE TO MAINTAIN CLEAN DEFINED BEDS. WEEDING: PHOSPHORUS (P2O5) 150+ LBS/ACRE POTASSIUM (K2O) 120+ LBS/ACRE · ALL BEDS SHALL BE WEEDED ON A CONTINUOUS BASIS THROUGHOUT THE GROWING SEASON TO MAINTAIN A NEAT TREES, SHRUBS AND GROUNDCOVER MAINTENANCE: APPEARANCE AT ALL TIMES. 1. PRUNE TREES, SHRUBS AND GROUNDCOVER TO ENCOURAGE HEALTHY GROWTH AND CREATE NATURAL SOLUBLE SALTS NOT TO EXCEED 900 PPM/1.9 MMHOS/CM IN SOIL; · PRE-EMERGENT (SOIL-APPLIED) AND POST-EMERGENT (FOLIAR-APPLIED) HERBICIDES SHALL BE USED WHERE AND APPEARANCE. NOT TO EXCEED 1400 PPM/2.5 MMHOS/CM IN HIGH ORGANIC MIX WHEN APPLICABLE AND IN ACCORDANCE WITH THE PRODUCT'S LABEL. 2. MULCH TO BE APPLIED IN FEBRUARY/MARCH WITH A HALF RATE IN LATE SUMMER TO TOPDRESS. WORKMANSHIP: 3. APPLY PRE-EMERGENT HERBICIDES IN FEBRUARY AND APRIL. INSECT & DISEASE CONTROL: TREES, SHRUBS & GROUNDCOVER · DURING LANDSCAPE MAINTENANCE OPERATIONS, ALL AREAS SHALL BE KEPT NEAT AND CLEAN. PRECAUTIONS 4. MANUAL WEED CONTROL TO MAINTAIN CLEAN BED APPEARANCE. SHALL BE TAKEN TO AVOID DAMAGE TO EXISTING STRUCTURES. ALL WORK SHALL BE PERFORMED IN A SAFE · THE MAINTENANCE CONTRACTOR SHALL BE RESPONSIBLE FOR MONITORING THE LANDSCAPE SITE ON A REGULAR 5. APPLY FUNGICIDE AND INSECTICIDES AS NEEDED TO CONTROL INSECTS AND DISEASE. MANNER TO THE OPERATORS, THE OCCUPANTS AND ANY PEDESTRIANS BASIS. THE MONITORING FREQUENCY SHALL BE MONTHLY EXCEPT FOR GROWING SEASON, WHICH WILL BE EVERY 6. ORNAMENTAL SHRUBS, TREES AND GROUNDCOVERS TO BE FERTILIZED THREE (3) TIMES PER YEAR WITH A OTHER WEEK. TRAINED PERSONNEL SHALL MONITOR FOR PLANT DAMAGING INSECT ACTIVITY, PLANT PATHOGENIC BALANCED MATERIAL (JANUARY/FEBRUARY, APRIL/MAY, OCTOBER/NOVEMBER) · UPON COMPLETION OF MAINTENANCE OPERATIONS, ALL DEBRIS AND WASTE MATERIAL SHALL BE CLEANED UP AND DISEASES AND POTENTIAL CULTURAL PROBLEMS IN THE LANDSCAPE. THE PEST OR CULTURAL PROBLEM WILL BE REMOVED FROM THE SITE, UNLESS PROVISIONS HAVE BEEN GRANTED BY THE OWNER TO USE ON-SITE TRASH 7. EDGE ALL MULCHED BEDS IDENTIFIED UNDER THE SUPERVISION OF THE CONTRACTOR RECEPTACLES ANY DAMAGE TO THE LANDSCAPE, STRUCTURES, OR IRRIGATION SYSTEMS CAUSED BY THE 8. REMOVE ALL LITTER AND DEBRIS. CLIENT: MAINTENANCE CONTRACTOR, SHALL BE REPAIRED BY THE MAINTENANCE CONTRACTOR WITHOUT CHARGE TO THE · FOR PLANT DAMAGING INSECTS AND MITES IDENTIFIED IN THE LANDSCAPE, THE CONTRACTOR SHALL CONSULT AND OWNER FOLLOW THE RECOMMENDATIONS OF THE MOST CURRENT EDITION OF THE STATE COOPERATIVE SERVICE GENERAL MAINTENANCE: PUBLICATION ON INSECT CONTROL ON LANDSCAPE PLANT MATERIAL TURF 1. REMOVE ALL MAN-MADE DEBRIS, BLOW EDGES. · PLANT PATHOGENIC DISEASE PROBLEMS IDENTIFIED BY THE CONTRACTOR THAT CAN BE RESOLVED BY PRUNING 2. INSPECT GROUNDS ON A MONTHLY BASIS AND SCHEDULE INSPECTION WITH UNIT OPERATOR. GENERAL CLEANUP: OR PHYSICAL REMOVAL OF DAMAGED PLANT PARTS WILL BE PERFORMED AS PART OF THE CONTRACT. FOR AN TOWER COURT · PRIOR TO MOWING, ALL TRASH, STICKS, AND OTHER UNWANTED DEBRIS SHALL BE REMOVED FROM LAWNS, PLANT ADDITIONAL CHARGE, PLANT PATHOGENIC DISEASES THAT CAN BE RESOLVED THROUGH PROPERLY TIMED BEDS, AND PAVED AREA APPLICATIONS OF FUNGICIDES SHALL BE MADE WHEN THE OWNER AUTHORIZES IT. CONDOMINIUMS MOWING: · IF THE CONTRACTOR NOTES AN ESPECIALLY INSECT-OR DISEASE-PRONE PLANT SPECIES IN THE LANDSCAPE, HE/SHE WILL SUGGEST REPLACEMENT WITH A MORE PEST-RESISTANT CULTIVARS OR SPECIES THAT IS CONSISTENT · TURF GRASSES, INCLUDING BLUE GRASS, TALL FESCUE, PERENNIAL RYEGRASS, ETC., SHALL BE MAINTAINED AT A WITH THE INTENT OF THE LANDSCAPE DESIGN 901-913 GREEN BAY ROAD & MAINTAINED AT NO LESS THAN 3". · NOTE: FOR IDENTIFICATION OF PLANT-DAMAGING INSECTS AND MITES, A REFERENCE TEXTBOOK THAT CAN BE USED IS INSECTS THAT FEED ON TREES AND SHRUBS BY JOHNSON AND LYON, COMSTOCK PUBLISHING ASSOCIATES. FOR 1007-1011 TOWER COURT · THE MOWING OPERATION INCLUDES TRIMMING AROUND ALL OBSTACLES, RAKING EXCESSIVE GRASS CLIPPINGS PLANT PATHOGENIC DISEASES, TWO REFERENCES ARE SUGGESTED· SCOUTING AND CONTROLLING WOODY AND REMOVING DEBRIS FROM WALKS, CURBS, AND PARKING AREAS. CAUTION: MECHANICAL WEEDERS SHOULD NOT ORNAMENTAL DISEASES IN LANDSCAPES AND NURSERIES, AUTHORIZED BY GARY MOORMAN, PUBLISHED BY PENN BE USED AROUND TREES BECAUSE OF POTENTIAL DAMAGE TO THE BARK. # Date: Description: By: STATE COLLEGE OF AGRICULTURAL SCIENCES, AND DISEASES OF TREES AND SHRUBS BY SINCLAIR AND LYON, PUBLISHED BY COMSTOCK PUBLISHING PRESS. 2026.03.03 Schematic Review EC EDGING: TRASH REMOVAL: 2026.03.23 Winnetka PD Review EC · EDGING OF ALL SIDEWALKS, CURBS AND OTHER PAVED AREAS SHALL BE PERFORMED ONCE EVERY OTHER MOWING DEBRIS FROM THE EDGING OPERATIONS SHALL BE REMOVED AND THE AREAS SWEPT CLEAN. CAUTION SHALL BE · THE MAINTENANCE CONTRACTOR SHALL REMOVE TRASH FROM ALL SHRUB AND GROUNDCOVER BEDS WITH EACH 2026.05.07 PD Submission EC USED TO AVOID FLYING DEBRIS. VISIT. FERTILIZING: LEAF REMOVAL: · SEASONALLY STEPPED FERTILIZER SHALL BE APPLIED IN AREAS BASED ON THE EXISTING TURF SPECIES · ALL FALLEN LEAVES SHALL BE REMOVED FROM THE SITE IN NOVEMBER AND ONCE IN DECEMBER. IF REQUESTED BY THE OWNER, THE MAINTENANCE CONTRACTOR, AT AN ADDITIONAL COST TO THE OWNER SHALL PERFORM LAWN WEED CONTROL: HERBICIDES SUPPLEMENTAL LEAF REMOVALS · SELECTION AND PROPER USE OF HERBICIDES SHALL BE THE LANDSCAPE CONTRACTOR'S RESPONSIBILITY ALL WINTER CLEANUP: CHEMICAL APPLICATIONS SHALL BE PERFORMED UNDER THE SUPERVISION OF A LICENSED CERTIFIED APPLICATOR. READ THE LABEL PRIOR TO APPLYING ANY CHEMICAL. · HE PROJECT SHALL RECEIVE A GENERAL CLEAN-UP ONCE DURING EACH OF THE WINTER MONTHS, I.E , JANUARY, FEBRUARY, AND MARCH. INSECT & DISEASE CONTROL FOR TURF: ·· CLEANING CURBS AND PARKING AREAS · THE CONTRACTOR SHALL BE RESPONSIBLE FOR MONITORING THE SITE CONDITIONS ON EACH VISIT TO DETERMINE ·· REMOVING ALL TRASH AND UNWANTED DEBRIS IF ANY INSECT PEST OR DISEASE PROBLEMS EXIST. THE CONTRACTOR SHALL IDENTIFY THE INSECT PEST OR ·· TURNING MULCH WHERE NECESSARY DISEASE, AS WELL AS THE HOST PLANT, AND THEN CONSULT THE MOST CURRENT EDITION OF THE COOPERATIVE ·· INSPECTION OF GROUNDS EXTENSION SERVICE'S "COMMERCIAL INSECTICIDE RECOMMENDATION FOR TURF" FOR CONTROL. THE LICENSED APPLICATOR SHALL BE FAMILIAR WITH THE LABEL PROVIDED FOR THE SELECTED PRODUCT PRIOR TO APPLICATION. SEASONAL COLOR: PERENNIALS, ANNUALS & BULBS MARIANI PLOT STAMP: J:\01 Projects\2026\Tower Court_260001\04 Construction\20260501_Tower Ct_CDs · INSPECTION AND TREATMENT TO CONTROL INSECT PESTS SHALL BE INCLUDED IN THE CONTRACT PRICE. THE INSTALLATION OF PERENNIALS, ANNUALS, AND BULBS, UNLESS SPECIFIED HEREIN, SHALL BE REVIEWED WITH THE OWNER, AND, IF ACCEPTED, INSTALLED AND BILLED TO THE OWNER TREES, SHRUBS & GROUNDCOVER SEASONAL COLOR MAINTENANCE: PRUNING: · PERENNIALIZATION OF BULBS · ALL ORNAMENTAL TREES, SHRUBS AND GROUND COVER SHALL BE PRUNED WHEN APPROPRIATE TO REMOVE DEAD OR DAMAGED BRANCHES, DEVELOP THE NATURAL SHAPES. DO NOT SHEAR TREES OR SHRUBS. IF PREVIOUS 1. AFTER FLOWERING, CUT OFF SPENT FLOWER HEADS MAINTENANCE PRACTICE HAS BEEN TO SHEAR AND BALL, THEN A NATURAL SHAPE WILL BE RESTORED GRADUALLY. 2. ALLOW LEAVES OF DAFFODILS AND HYACINTHS TO REMAIN FOR SIX WEEKS AFTER FLOWERS HAVE FADED. CUT OFF AT BASE · PRUNING GUIDELINES: 3. ALLOW LEAVES OF OTHER BULBS TO YELLOW NATURALLY AND THEN CUT OFF AT BASE. 1. PRUNE PLANTS THAT FLOWER BEFORE THE END OF JUNE (SPRING BLOOMING) IMMEDIATELY AFTER 4. APPLY FERTILIZER AFTER FLOWERING IN SPRING, POSSIBLY AGAIN IN FALL. APPLY 10-10-10 AT THE RATE OF 2 FLOWERING FLOWER BUDS DEVELOP DURING THE PREVIOUS GROWING SEASON. FALL, WINTER OR SPRING This plan is conceptual; all dimensions are to be verified. Materials are represented POUNDS PER 1000 SQUARE FEET OR TOP-DRESS WITH COMPOST 1ft DEEP. FALL FERTILIZATION WITH A BULB in their future condition in a more mature state. All designs and ideas contained in PRUNING WOULD REDUCE THE SPRING FLOWERING DISPLAY. these drawings are not to be used as final construction documents by other than FERTILIZER OR MULCHING WITH r OF COMPOST IS OPTIONAL. MARIANI ENTERPRISES, INC.Th ey a r e th e so le pr op er ty of MARIANI 2. PRUNE PLANTS THAT FLOWER IN JULY - SEPTEMBER (SUMMER OR AUTUMN BLOOMING) IN WINTER OR SPRING ENTERPRISES, INC. and are not to be duplicated or put to bid without express BEFORE NEW GROWTH BEGINS, SINCE THESE PLANTS DEVELOP FLOWERS ON NEW GROWTH · FLOWER ROTATION written consent. Graphic representations are for illustrative purposes; field adjustments may be made during installation in keeping with the design intent. 3. DELAY PRUNING PLANTS GROWN FOR ORNAMENTAL FRUITS, SUCH AS COTONEASTERS AND VIBURNUMS 1. BULBS: REMOVE THE ENTIRE PLANT AND BULB AFTER FLOWERS HAVE FADED OR AT THE DIRECTION OF THE 4. HOLLIES AND OTHER EVERGREENS MAY BE PRUNED DURING WINTER IN ORDER TO USE THEIR BRANCHES FOR OWNER AND INSTALL NEW PLANTS IF INCLUDED IN CONTRACT. SEASONAL DECORATION. HOWEVER, SEVERE PRUNING OF EVERGREENS SHOULD BE DONE IN EARLY SPRING 2. SUMMER ANNUALS OR FALL PLANTS: DESIGN: EC ONLY. a. DEAD HEADING: PINCH AND REMOVE DEAD FLOWERS ON ANNUALS AS NECESSARY 5. BROADLEAF EVERGREEN SHRUBS SHALL BE HAND-PRUNED TO MAINTAIN THEIR NATURAL APPEARANCE AFTER b. FERTILIZING SUMMER ANNUALS: FERTILIZE USING ONE OR TWO METHODS: APPLY A SLOW-RELEASE THE NEW GROWTH HARDENS OFF. FERTILIZER IN MAY FOLLOWING MANUFACTURER'S RECOMMENDATIONS. A BOOSTER SUCH AS 10-10-10 DRAFTED: EC 6. HEDGES OR SHRUBS THAT REQUIRE SHEARING TO MAINTAIN A FORMAL APPEARANCE SHALL BE PRUNED AS MAY BE NECESSARY IN LATE SUMMER. OR, APPLY LIQUID FERTILIZATIONS OF 20-20-20 WATER-SOLUBLE REQUIRED. DEAD WOOD SHALL BE REMOVED FROM SHEARED PLANTS BEFORE THE FIRST SHEARING OF THE FERTILIZERS, NOT TO EXCEED 2 POUNDS OF 20-20-20 PER 100 GALLONS OF WATER, MONTHLY; OR MULCH CHECKED: CB SEASON WITH COMPOST 1" DEEP N O R T H NOT FOR CONSTRUCTION 7. CONIFERS SHALL BE PRUNED, IF REQUIRED, ACCORDING TO THEIR GENUS c. REMOVAL: IF FALL PLANTS ARE TO BE INSTALLED, SUMMER ANNUALS SHALL BE LEFT IN THE GROUND ·· YEWS, JUNIPERS, HEMLOCKS AND ARBORVITAE MAY BE PRUNED AFTER NEW GROWTH HAS HARDENED UNTIL THE FIRST KILLING FROST AND THEN REMOVED, UNLESS OTHERWISE DIRECTED BY THE OWNER SCALE: 1:10 OFF IN LATE SUMMER. IF SEVERE PRUNING IS NECESSARY, IT MUST BE DONE IN EARLY SPRING. PERENNIALS: ·· FIRS AND SPRUCES MAY BE LIGHTLY PRUNED IN LATE SUMMER, FALL, OR WINTER AFTER COMPLETING GROWTH LEAVE SIDE BUDS NEVER CUT CENTRAL LEADER. · AFTER INITIAL INSTALLATION, IF A TIME-RELEASED FERTILIZER HAS BEEN INCORPORATED DURING PLANT ·· PINES MAY BE LIGHTLY PRUNED IN EARLY JUNE BY REDUCING CANDLES INSTALLATION, NO MORE FERTILIZER NEED BE APPLIED THE FIRST GROWING SEASON. 0 5' 10' 20' 30' 8. GROUNDCOVER SHALL BE EDGED AND PRUNED AS NEEDED TO CONTAIN IT WITHIN ITS BORDERS. · THE FOLLOWING YEAR: 9. THINNING: REMOVE BRANCHES AND WATER SPROUTS BY CUTTING THEM BACK TO THEIR POINT OF ORIGIN ON 1. FERTILIZE PERENNIALS WITH A SLOW-RELEASE FERTILIZER OR ANY 50% ORGANIC FERTILIZER, OR MULCH ISSUED DATE: 2026.02.24 PARENT STEMS. THIS METHOD RESULTS IN A MORE OPEN PLANT, WITHOUT STIMULATING EXCESSIVE GROWTH. PERENNIALS WITH COMPOST 1" DEEP. THINNING IS USED ON CRAB APPLES, LILACS, VIBURNUMS, ETC PROJECT NO: TC26001 2. CUT ALL DECIDUOUS PERENNIALS FLUSH TO THE GROUND BY MARCH 1, IF THIS WAS NOT DONE THE PREVIOUS 10. RENEWAL PRUNING: REMOVE OLDEST BRANCHES OF SHRUB AT GROUND, LEAVING THE YOUNGER, MORE FALL, TO ALLOW NEW GROWTH TO DEVELOP FREELY VIGOROUS BRANCHES. ALSO REMOVE WEAK STEMS. ON OVERGROWN PLANTS, THIS METHOD MAY BE BEST 3. MULCH THE PERENNIAL BED ONCE IN EARLY SPRING AT 1"-2" DEPTH. IF SOIL IS BARED IN LATE FALL, RE-MULCH MAINTENANCE DONE OVER A THREE-YEAR PERIOD. RENEWAL PRUNING MAY BE USED ON FORSYTHIA, HYDRANGEA, SPIREA, LIGHTLY AFTER GROUND IS FROZEN TO PROTECT PERENNIALS. ETC. 4. INSPECT FOR INSECT OR DISEASE PROBLEMS ON PERENNIALS. MONITOR AND CONTROL SLUGS ON HOST AS 11.PLANTS OVERHANGING PASSAGEWAYS AND PARKING AREAS AND DAMAGED PLANTS SHALL BE PRUNED AS AND LIGULARIAS. POWDERY MILDEW ON PHLOX, MONARDAS, AND ASTERS CAN BE PREVENTED WITH NEEDED 12. SHADE TREES THAT CANNOT BE ADEQUATELY PRUNED FROM THE GROUND SHALL NOT BE INCLUDED IN THE PROPERLY TIMED FUNGICIDES OR USE OF DISEASE-RESISTANT VARIETIES 5. WEED PERENNIAL BED AS SPECIFIED IN "WEEDING" ABOVE. SPECIFICATIONS MAINTENANCE CONTRACT. A CERTIFIED ARBORIST UNDER A SEPARATE CONTRACT SHALL PERFORM THIS TYPE OF WORK L7.1 Page 90 of 207 CONTROL JOINTS, SPACING PER LAYOUT PLAN. 81" WIDE ADJACENT CAST IN PLACE ,TYP. 41" SLAB DEPTH. 41" CONCRETE WALK RADIUM TOOLED JOINTS 300 Rockland Road | Lake Bluff, Illinois 60045 5" PORTLAND CEMENT CONCRETE Phone: 847.234.2172 | Fax: 847.234.2754 CONCRETE WALK. SEE MIN 18" BRICK UNIT PAVER CARRIAGE WALK, CLASS SI, FINE TO MEDIUM DETAIL X SHEET L8.0 www.marianilandscape.com WALK: STANDARD SIZE PINE BROOM FINISH HALL RUMBLED FULL RANGE. 1 2" EXPANSION JOINT AT NEW CURB 1" SAND SETTING BED NEW CONCRETE CURB 1 2" EXPANSION JOINT AT NEW CURB NEW BUILDING & ASSOCIATED CONTROL JOINT ADJACENT CONCRETE CURB FOUNDATION CONSULTANTS: & GUTTER ALONG GREEN BAY 6"X6" WELDED WIRE FABRIC, ROAD. SEE CIVIL PLANS FOR 1 EPOXY COATED EACH EXPANSION JOINT: 2"EXPANSION JOINT BETWEEN CONSTRUCTION DETAILS NEW CONCRETE SIDEWALK 3 AND SPECIFICATIONS MIN 2" DEPTH IDOT CA-6 4" SPACED AT 40' AND BUILDING FOUNDATION COMPACTED GRANULAR SUBBASE INTERVAL MAX 5" CONCRETE SUB-BASE W/ 6"X6" WWF CONCRETE WALK. SEE CONCRETE WALK. SEE UNDISTURBED/COMPACTED 3'-0" MIN MIN 6" COMPACTED GRAVEL DETAIL X SHEET L8.0 BASE SUB-GRADE DETAIL X SHEET L8.0 STRUCTURAL SOIL 36" DEPTH MIN. SEE L5.0 MATERIALS PLAN FOR LIMITS EXPANSION JOINT BRICK UNIT PAVER: STANDARD SIZE PINE HALL RUMBLED FULL RANGE SEE DETAILS A SHEET L8.0 BRICK UNIT PAVER CARRIAGE WALK CAST IN PLACE CONCRETE PAVING CONCRETE JOINTS, TYP. CONCRETE JOINT AT BUILDING A 1 1/2" = 1'-0" B 1 1/2" = 1'-0" C 1 1/2" = 1'-0" D 1 1/2" = 1'-0" CLIENT: 71.875" TREE GRATE: 4'x6' IRON AGE MINNIONE IRON TREE GRATE, RAW FINISH w/ CUSTOM 16"Ø OPENING, ELECTRIC TOWER COURT CONDOMINIUMS 47.875" ACCESS PANEL TREE GRATE TO INSTALLED w/ IRON AGE STAND-OFF EMBED PERIMETER FRAME 901-913 GREEN BAY ROAD & 1007-1011 TOWER COURT (1) EXTERIOR GRADE GFCI OUTLET LOCATED AT EA " PARKWAY TREE GRATE, # Date: Description: By: 25 E 4'X6' IRON AGE TREE GRATE SEE 1. G TYP. 2026.03.03 Schematic Review EC ED TREE FRAME TO BE ANCHORED W/ #3 DETAIL G-H SHEET L8.0 2026.03.23 Winnetka PD Review EC REBAR TO CONCRETE SIDEWALK BASE SHREDDED HARDWOOD BARK 2026.05.07 PD Submission EC MULCH 4" MIN DEPTH. NO BARK ADJACENT CAST IN TO BE PLACED AGAINST BASE PLACE CONCRETE WALK. 4'-0" OF TREE TRUNK. IRON TREE GRATE SEE DETAIL B SHEET L8.0 IRON AGE TREE GRATE FRAME F NTS PEDESTRIAN SIGNALIZED ANCHORED TO CONCRETE CURB CROSSING SIGNAGE: #3 REBAR CONCRETE ANCHOR EMEDCO 36"x36" PUSH BUTTON PEDESTRIAN CROSSING SIGN ADJACENT CONCRETE CURB & TREE GRATE PERIMETER FRAME: FINAL POWER SUPPLY SOURCE 1'-0" GUTTER ALONG GREEN BAY IRON AGE STAND-OFF EMBED AND SIGN LOCATION TO BE STERNBERG 4100 ROAD. SEE CIVIL PLANS FOR PERIMETER FRAME COORDINATED WITH WINNETKA 4" AUGUSTA SIGNAGE CONSTRUCTION DETAILS AND ENGINEERING DEPARTMENT 9 POLE SPECIFICATIONS 1'-216 " TYP, BACKFILL SOIL MIX, 30" MIN (4) 21"Ø, HOT DIPPED DEPTH GALVANIZED "L" TYPE CIP CONCRETE TREE GRATE 3'-0" SUPPORT CURB ANCHOR BOLTS STRUCTURAL SOIL 36" DEPTH MIN SEE L5.0 MATERIALS PLAN FOR ADJACENT BRICK UNIT LIMITS PAVER MARIANI PLOT STAMP: J:\01 Projects\2026\Tower Court_260001\04 Construction\20260501_Tower Ct_CDs STERNBERG 4100 42" MIN TO 4" SDR 35 PERF PVC PIPE W/ TREE GRATE PERIMETER FRAME: 4" AUGUSTA SIGNAGE POLE IRON AGE STAND-OFF EMBED SET ON CONCRETE POST MIN 14"Ø CONCRETE CONNECTIONS TO DRAINAGE POST HOLE FROST DEPTH SYSTEM. SEE CIVIL PLANS FOR PERIMETER FRAME HOLE FOUNDATION FOUNDATION TO FINAL LOCATIONS FROST DEPTH (MIN. 42") CIP CONCRETE TREE GRATE UNDISTURBED SUBGRADE SUPPORT CURB 1'-2" This plan is conceptual; all dimensions are to be verified. Materials are represented in their future condition in a more mature state. All designs and ideas contained in TREE GRATE WITH STRUCTURAL SOIL TREE GRATE PERIMETER FRAME PEDESTRIAN SIGNALIZED CROSSING these drawings are not to be used as final construction documents by other than MARIANI ENTERPRISES, INC.Th ey a r e th e so le pr op er ty of MARIANI E 3/4" = 1'-0" G NTS H NTS ENTERPRISES, INC. and are not to be duplicated or put to bid without express written consent. Graphic representations are for illustrative purposes; field adjustments may be made during installation in keeping with the design intent. DESIGN: EC DRAFTED: EC 1'-458" DETECTABLE WARNING PLATES: CHECKED: CB NEENAH FOUNDRY UNFINISHED. N O R T H NOT FOR CONSTRUCTION MAGLIN MBR200 BIKE FINAL LOCATION TO BE RACK - BLACK POWDER COORDINATED WITH WINNETKA SCALE: 2'-1113 2'-1113 1:10 16" 16" COAT FINISH ENGINEERING DEPARTMENT SEE CIVIL PLANS FOR CONSTRUCTION DETAILS AND 1'-6" MAINTAIN CONTINUOUS SPECIFICATIONS BRICK UNIT PAVER AROUND BIKE RACK 0 5' 10' 20' 30' BURY BURY ISSUED DATE: 2026.02.24 1'-6" 1'-6" 42" MIN TO 42" MIN TO PROJECT NO: TC26001 FROST DEPTH FROST DEPTH 10"Ø CONCRETE POST FOUNDATION TO FROST SITE DETAILS DEPTH (MIN. 42") 10" 10" MIN MIN J STANDARD BIKE RACK 1/2" = 1'-0" K DETECTABLE WARNING PLATES NTS L8.0 Page 91 of 207 LANDSCAPE LIGHTING LEGEND GENERAL LANDSCAPE DESIGN NOTE: SYMBOL DESCRIPTION QTY. FINAL LANDSCAPE AND FUTURE CROSSWALK LOCATIONS ARE SUBJECT TO SMALL BULLET UPLIGHT FIXTURE 3 COORDINATION WITH THE VILLAGE OF WINNETKA'S COMPREHENSIVE HUBBARD WOODS STREETSCAPE IMPROVEMENT PLANS, CURRENTLY UNDER DEVELOPMENT BY OTHERS. POST MOUNTED PEDESTRIAN LIGHT 2 STREETSCAPE ENHANCEMENTS SHOWN ARE FOR REFERENCE AND OVERALL DESIGN INTENT. CROSSWALK IMPROVEMENTS HAVE BEEN OMITTED PER SUGGESTION BY BUILDING WALL SCONCE VILLAGE OF WINNETKA STAFF. SEE EXTERIOR LIGHTING PLAN 300 Rockland Road | Lake Bluff, Illinois 60045 NOTE: ALL ELECTRIC FOR LIGHTING TO BE IN CONDUIT Phone: 847.234.2172 | Fax: 847.234.2754 www.marianilandscape.com ELECTRIC LEGEND SYMBOL QTY. GFCI OUTLETS - ACCESSORY USE 5 STERNBERG 4200 CONSULTANTS: AUGUSTA POLE NOTE: ALL ELECTRIC FOR OUTLETS TO BE IN CONDUIT 1'-6" ACCESS DOOR PROPERTY LINE 1'-434" 12"Ø BOLT CICLE EGRESS CORRIDOR (4) 21"Ø, HOT DIPPED GALVANIZED "L" TYPE 1,512 SF ANCHOR BOLTS ADJACENT BRICK UNIT PAVER TRASH 42" MIN TO MIN 18"Ø CONCRETE POST FOUNDATION TO FROST DEPTH FROST DEPTH (MIN. 42") REBEL HOUSE 1'-634" 2,375 SF PEDESTRIAN LIGHT POLE LIGHT POLE FOOTING B NTS C 1/2" = 1'-0" CLIENT: SMALL LANDSCAPE LIGHT TOWER COURT STAIR FIXTURE: DAUER FAIRMONT SOLID CONDOMINIUMS STANDARD STREETSCAPE 185 SF COMMERCIAL BRASS SMALL BULLET UPLIGHT, WEATHERED BRASS 901-913 GREEN BAY ROAD & PEDESTRIAN LIGHT POLE 9,620 SF FINISH 1007-1011 TOWER COURT COMMERCIAL WITH BANNER ARMS, TYP. SEE DETAILS A-C SHEET L9.0 1,548 SF INSTALL ON HEAVY DUTY COMPOSITE STAKE INCLUDED UPPER DECK # Date: Description: By: w/ FIXTURE (1) EXTERIOR GRADE GFCI 2026.03.03 Schematic Review EC OUTLET TO BE LOCATED 2026.03.23 Winnetka PD Review EC AT EA PARKWAY TREE GRATE, TYP. PEDESTRIAN LIGHT POLE ELEV LANDSCAPE LIGHT FIXTURE LANDSCAPE LIGHT FIXTURE 2026.05.07 PD Submission EC A NTS D E NTS NTS 60'-0" STAIR 185 SF PARKING GARAGE COMMERCIAL COMMERCIAL RAMP 1,473 SF 846 SF BUILDER TO PROVIDE ELECTRIC TOWER COURT OUTLETS ALONG EXTERIOR OF MARIANI PLOT STAMP: J:\01 Projects\2026\Tower Court_260001\04 Construction\20260501_Tower Ct_CDs BUILDING FOR MAINTENANCE & SEASONAL NEEDS. FINAL CONDO ENTRY LOCATIONS BY ARCHITECT. 550 SF LIGHTING AT BUILDING CANTILEVER BY BUILDER. 2'-9" SEE ARCHITECTURAL EXTERIOR GROUND LEVEL LIGHTING PLAN. STANDARD STREETSCAPE PEDESTRIAN LIGHT POLE This plan is conceptual; all dimensions are to be verified. Materials are represented WITH BANNER ARMS, TYP. in their future condition in a more mature state. All designs and ideas contained in SEE DETAILS A-C SHEET L9.0 these drawings are not to be used as final construction documents by other than MARIANI ENTERPRISES, INC.Th ey a r e th e so le pr op er ty of MARIANI ENTERPRISES, INC. and are not to be duplicated or put to bid without express (1) EXTERIOR GRADE GFCI written consent. Graphic representations are for illustrative purposes; field adjustments may be made during installation in keeping with the design intent. OUTLET FOR MAINTENANCE WALL SCONE AT BUILDING BY & SEASONAL NEEDS. FINAL BUILDER. SEE ARCHITECTURAL LIGHTING AT PARKING LOCATION TO BE EXTERIOR GROUND LEVEL GARAGE RAMP BY BUILDER. SEE ARCHITECTURAL DESIGN: EC COORDINATED WITH LIGHTING PLAN EXTERIOR GROUND LEVEL LANDSCAPE ARCHITECT. PARALLEL PARKING ONE-WAY STREET LIGHTING PLAN. DRAFTED: EC 14 SPACES PROPERTY LINE (3) SMALL LANDSCAPE ACCENT BULLET UP LIGHT CHECKED: CB SEE DETAILS D-E SHEET N O R T H NOT FOR CONSTRUCTION L9.0 SCALE: 1:10 GREEN BAY ROAD PROPERTY LINE 0 5' 10' 20' 30' EXISTING ADJACENT BUILDING ISSUED DATE: 2026.02.24 PROJECT NO: TC26001 UTILITY & LIGHTING PLAN L9.0 Page 92 of 207 ALTOUNIAN CONSTRUCTION ERIKSSON TOWER COURT CONDOMINIUMS ENGINEERING ASSOCIATES, LTD. 145 COMMERCE DRIVE, SUITE A GRAYSLAKE, ILLINOIS 60030 ALTOUNIAN CONSTRUCTION phone (847) 223-4804 901 GREEN BAY ROAD fax (847) 223-4864 email INFO@EEA-LTD.COM Professional Design Firm License No. 184-003220 Expires: 04/30/2027 WINNETKA, ILLINOIS 60093 901 GREEN BAY ROAD TOWER COURT CONDOS WINNETKA, ILLINOIS 60093 Reserved for Seal: SSI ROFE ONAL E DP N LICE NS EER E TIMOTHY GIN OWENBROWN 062-068681 03.24.2026 ST A TE OI S OF I L LI N EXPIRATIONDATE: 11/30/27 No. Date Description SITE LOCATION MAP (N.T.S.) INDEX OF SHEETS C ERIKSSON ENGINEERING ASSOCIATES, LTD., 2026 Design By: Approved By: Date: Sheet Title: SURVEY PROVIDED BY: J.U.L.I.E. CIVIL ENGINEERING COVER SHEET PROJECT BENCHMARKS Sheet No: C000 Page 93 of 207 ERIKSSON ENGINEERING ASSOCIATES, LTD. 145 COMMERCE DRIVE, SUITE A GRAYSLAKE, ILLINOIS 60030 ALTOUNIAN CONSTRUCTION phone (847) 223-4804 fax (847) 223-4864 email INFO@EEA-LTD.COM Professional Design Firm License No. 184-003220 Expires: 04/30/2027 901 GREEN BAY ROAD TOWER COURT CONDOS WINNETKA, ILLINOIS 60093 Reserved for Seal: SSI ROFE ONAL E DP N LICE NS EER E TIMOTHY GIN OWENBROWN 062-068681 03.24.2026 ST AT E OI S OF I L LI N EXPIRATIONDATE: 11/30/27 No. Date Description C ERIKSSON ENGINEERING ASSOCIATES, LTD., 2026 Design By: Approved By: Date: Sheet Title: GRADING AND PAVING PLAN Sheet No: C400 Page 94 of 207 GENERAL NOTES R FO M ER ERIKSSON ENGINEERING ASSOCIATES, LTD. 145 COMMERCE DRIVE, SUITE A GRAYSLAKE, ILLINOIS 60030 O LEGEND ALTOUNIAN CONSTRUCTION phone (847) 223-4804 AG fax (847) 223-4864 email INFO@EEA-LTD.COM IC Professional Design Firm License No. 184-003220 CH Expires: 04/30/2027 901 GREEN BAY ROAD & T6 L O BLOCK 5 TOWER COURT CONDOS NO DEMOLITION NOTES RT WINNETKA, ILLINOIS 60093 7 ES LO T HW TE RN T 8 LO GR N 9 RA EE LO T ILR Reserved for Seal: SSI ROFE ONAL E DP OA N LICE NS EER LO E TIMOTHY GIN T1 D OWENBROWN 1 062-068681 03.24.2026 DEMOLITION LEGEND ST AT E OI S OF I L LI N 10 LOT EXPIRATIONDATE: 11/30/27 BA LO Y No. Date Description T1 2 O BL CK NOT FOR CONSTRUCTION T1 LO 3 6 RO C ERIKSSON ENGINEERING ASSOCIATES, LTD., 2026 Design By: Approved By: Date: AD Sheet Title: SURVEY PROVIDED BY: J.U.L.I.E. SITE DEMOLITION PLAN PROJECT BENCHMARKS Sheet No: C100 Page 95 of 207 GENERAL NOTES R FO M ER ERIKSSON ENGINEERING ASSOCIATES, LTD. 145 COMMERCE DRIVE, SUITE A GRAYSLAKE, ILLINOIS 60030 O LEGEND ALTOUNIAN CONSTRUCTION phone (847) 223-4804 AG fax (847) 223-4864 email INFO@EEA-LTD.COM IC Professional Design Firm License No. 184-003220 CH Expires: 04/30/2027 901 GREEN BAY ROAD & TOWER COURT CONDOS NO GEOMETRY NOTES RT WINNETKA, ILLINOIS 60093 ES HW TE RN GR N RA EE ILR Reserved for Seal: SSI ROFE ONAL E DP OA N LICE NS EER LO E TIMOTHY GIN T1 D OWENBROWN 1 062-068681 03.24.2026 ST AT E OI S OF I L LI N EXPIRATIONDATE: 11/30/27 BA LO Y No. Date Description T1 2 O BL CK NOT FOR CONSTRUCTION T1 LO 3 6 RO C ERIKSSON ENGINEERING ASSOCIATES, LTD., 2026 Design By: Approved By: Date: AD Sheet Title: SURVEY PROVIDED BY: J.U.L.I.E. SITE GEOMETRY PLAN PROJECT BENCHMARKS Sheet No: C200 Page 96 of 207 GENERAL NOTES R FO M ER ERIKSSON ENGINEERING ASSOCIATES, LTD. 145 COMMERCE DRIVE, SUITE A GRAYSLAKE, ILLINOIS 60030 O LEGEND ALTOUNIAN CONSTRUCTION phone (847) 223-4804 AG fax (847) 223-4864 email INFO@EEA-LTD.COM IC Professional Design Firm License No. 184-003220 CH Expires: 04/30/2027 901 GREEN BAY ROAD & TOWER COURT CONDOS NO UTILITY NOTES RT WINNETKA, ILLINOIS 60093 ES HW TE RN GR N RA EE ILR Reserved for Seal: STRUCTURE NOTES SSI ROFE ONAL E DP OA N LICE NS EER LO E TIMOTHY GIN T1 D OWENBROWN 1 062-068681 03.24.2026 ST AT E OI S OF I L LI N EXPIRATIONDATE: 11/30/27 BA LO Y No. Date Description T1 2 O BL CK NOT FOR CONSTRUCTION T1 LO 3 6 RO C ERIKSSON ENGINEERING ASSOCIATES, LTD., 2026 Design By: Approved By: Date: AD Sheet Title: SURVEY PROVIDED BY: J.U.L.I.E. SITE UTILITY PLAN PROJECT BENCHMARKS Sheet No: C300 Page 97 of 207 GENERAL NOTES R FO M ER ERIKSSON ENGINEERING ASSOCIATES, LTD. 145 COMMERCE DRIVE, SUITE A GRAYSLAKE, ILLINOIS 60030 O LEGEND ALTOUNIAN CONSTRUCTION phone (847) 223-4804 AG fax (847) 223-4864 email INFO@EEA-LTD.COM IC Professional Design Firm License No. 184-003220 CH Expires: 04/30/2027 901 GREEN BAY ROAD & TOWER COURT CONDOS NO GRADING NOTES RT WINNETKA, ILLINOIS 60093 ES HW TE RN GR N RA EE ILR Reserved for Seal: SSI ROFE ONAL E DP OA N LICE NS EER LO E TIMOTHY GIN T1 D OWENBROWN 062-068681 1 PAVING & SURFACE 03.24.2026 LEGEND ST AT E OF I L LI N OI S EXPIRATIONDATE: 11/30/27 BA LO Y No. Date Description T1 2 O BL CK NOT FOR CONSTRUCTION T1 LO 3 6 RO C ERIKSSON ENGINEERING ASSOCIATES, LTD., 2026 Design By: Approved By: Date: AD Sheet Title: SURVEY PROVIDED BY: J.U.L.I.E. GRADING AND PAVING PLAN PROJECT BENCHMARKS Sheet No: C400 Page 98 of 207 GENERAL NOTES R FO M ER ERIKSSON ENGINEERING ASSOCIATES, LTD. 145 COMMERCE DRIVE, SUITE A GRAYSLAKE, ILLINOIS 60030 O LEGEND ALTOUNIAN CONSTRUCTION phone (847) 223-4804 AG fax (847) 223-4864 email INFO@EEA-LTD.COM IC Professional Design Firm License No. 184-003220 CH Expires: 04/30/2027 901 GREEN BAY ROAD & TOWER COURT CONDOS NO SOIL EROSION & SEDIMENTATION CONTROL RT NOTES WINNETKA, ILLINOIS 60093 ES HW TE RN GR N RA EE ILR Reserved for Seal: SSI ROFE ONAL E DP OA N LICE NS EER LO E TIMOTHY GIN T1 D OWENBROWN 1 062-068681 03.24.2026 SOIL EROSION & ST AT E OI S SEDIMENTATION CONTROL OF I L LI N LEGEND EXPIRATIONDATE: 11/30/27 BA LO Y No. Date Description T1 2 O BL CK NOT FOR CONSTRUCTION T1 LO 3 6 RO C ERIKSSON ENGINEERING ASSOCIATES, LTD., 2026 Design By: Approved By: Date: AD Sheet Title: SURVEY PROVIDED BY: J.U.L.I.E. SITE EROSION AND SEDIMENT CONTROL PLAN PROJECT BENCHMARKS Sheet No: C500 Page 99 of 207 ERIKSSON ENGINEERING ASSOCIATES, LTD. 145 COMMERCE DRIVE, SUITE A GRAYSLAKE, ILLINOIS 60030 ALTOUNIAN CONSTRUCTION phone (847) 223-4804 fax (847) 223-4864 email INFO@EEA-LTD.COM Professional Design Firm License No. 184-003220 Expires: 04/30/2027 901 GREEN BAY ROAD TOWER COURT CONDOS WINNETKA, ILLINOIS 60093 Reserved for Seal: SSI ROFE ONAL E DP N LICE NS EER E TIMOTHY GIN OWENBROWN 062-068681 03.24.2026 ST AT E OI S OF I L LI N EXPIRATIONDATE: 11/30/27 No. Date Description NOT FOR CONSTRUCTION C ERIKSSON ENGINEERING ASSOCIATES, LTD., 2026 Design By: Approved By: Date: Sheet Title: SITE DETAILS Sheet No: C600 Page 100 of 207 ERIKSSON ENGINEERING ASSOCIATES, LTD. 145 COMMERCE DRIVE, SUITE A GRAYSLAKE, ILLINOIS 60030 ALTOUNIAN CONSTRUCTION phone (847) 223-4804 fax (847) 223-4864 email INFO@EEA-LTD.COM Professional Design Firm License No. 184-003220 Expires: 04/30/2027 901 GREEN BAY ROAD TOWER COURT CONDOS WINNETKA, ILLINOIS 60093 Reserved for Seal: SSI ROFE ONAL E DP N LICE NS EER E TIMOTHY GIN OWENBROWN 062-068681 03.24.2026 ST AT E OI S OF I L LI N EXPIRATIONDATE: 11/30/27 No. Date Description NOT FOR CONSTRUCTION C ERIKSSON ENGINEERING ASSOCIATES, LTD., 2026 Design By: Approved By: Date: Sheet Title: SITE DETAILS Sheet No: C601 Page 101 of 207 F5 F6 1,512 253 F6 2,375 F4 9,620 F4 F4 1,473 846 F4 F3 F3 F3 550 TOWER COURT CONDOMINIUMS OKW ARCHITECTS TOWER COURT 600 W. Jackson, Suite 250 Chicago, IL 60661 WINNETKA LLC 1011 Tower Court, Winnetka, IL 21 May 07, 2026 Project #: 25057 Page 102 of 207 4,128 2,746 TOWER COURT CONDOMINIUMS OKW ARCHITECTS TOWER COURT 600 W. Jackson, Suite 250 Chicago, IL 60661 WINNETKA LLC 1011 Tower Court, Winnetka, IL 22 May 07, 2026 Project #: 25057 Page 103 of 207 TOWER COURT CONDOMINIUMS OKW ARCHITECTS TOWER COURT 600 W. Jackson, Suite 250 Chicago, IL 60661 WINNETKA LLC 1011 Tower Court, Winnetka, IL 23 May 07, 2026 Project #: 25057 Page 104 of 207 TOWER COURT CONDOMINIUMS OKW ARCHITECTS TOWER COURT 600 W. Jackson, Suite 250 Chicago, IL 60661 WINNETKA LLC 1011 Tower Court, Winnetka, IL 24 May 07, 2026 Project #: 25057 Page 105 of 207 4' - 7 5/8" FLOOR PLANS SIDE 7 5/8" SIDE STORM 18' - 0" 15 TYP. SUMP 8' - 7 1/2" LOWERED CEILING TYP. HEIGHT CLARENCE 8' - 6" PARKING 18,629 SF RAMP 46 STAIR UP SPACES (3 ADA) 139 SF INC. 4 TANDEM 5 5 12' - 2" TRASH REAR 118 SF PARKING ELEV LOBBY 4-T 7 782 SF STAIR 0'-0" FRONT 185 SF OIL INT MECH WH WH 454 SF 10 OVERHEAD BEAM SAN EJECTOR BACKUP GENERATOR 23' - 1" SIDE LOWER LEVEL N TOWERCOURT TOWER COURTCONDOMINIUMS CONDOMINIUMS OKW ARCHITECTS TOWER TOWERCOURT COURT 29 03 OKW ARCHITECTS SCALE: 1" = 20' 600 W. Jackson, Suite 250 600 W. Jackson, Suite 250 Chicago,ILIL Chicago, 60661 60661 WINNETKA WINNETKALLC LLC GREEN BAY Court, 1011 Tower RD. WINNETKA, IL Winnetka, IL Architects 0 5' 10' 20' May 12/19/25 07, 2026 Project #: 25057 Project #: 25057 PROJECT Page 106 of 207 FLOOR PLANS 4' - 11" SIDE NEIGHBORING BUILDING EGRESS TRANSFER 7 1/4" SIDE 1' - 2" FRONT EGRESS CORRIDOR 6" 1,512 SF REAR TRASH 253 SF REBEL HOUSE 7' - 8" 2,375 SF REAR COLUMN BUILDING CANTILEVER 8' - 6" STAIR TYP. 185 SF COMMERCIAL 9,620 SF COMMERCIAL 20' - 0" 1,548 SF UPPER DECK TYP. ELEV 0' - 0" FRONT STAIR 185 SF 1' - 2" FRONT COMMERCIAL COMMERCIAL 1,473 SF 846 SF 21' - 4" CONDO ENTRY 550 SF 8' - 2" RAMP DN 21' - 7 1/2" TYP. 21' - 4" 36' - 2" TYP. PARALLEL PARKING DRIVE AISLE (ONE WAY) SIDE 14 SPACES 1ST LEVEL TOWER TOWER COURTCONDOMINIUMS COURT CONDOMINIUMS OKW ARCHITECTS N TOWER COURT TOWER COURT OKW ARCHITECTS 600 W. 600 Jackson, Suite 250 W. Jackson, Chicago, Suite 250 IL 60661 Chicago, IL 60661 SCALE: 1" = 20' WINNETKA LLC WINNETKA LLC 1011 BAY GREEN TowerRD. Court, Winnetka,ILIL WINNETKA, 30 04 Architects 0 5' 10' 20' May 07, 2026 Project #: 25057 5/52026 Project #: 25057 PROJECT Page 107 of 207 FLOOR PLANS 5' - 7" SIDE 3' - 4" 1' - 9 3/4" PRIVATE TERRACES, TYP. SIDE FRONT PRIVATE TERRACES, TYP. 201 204 4,128 SF STAIR 3,245 SF 185 SF 6' - 3" REAR CORRIDOR 776 SF ELEV STAIR 185 SF 202 203 205 3,150 SF 2,746 SF 3,070 SF PRIVATE TERRACES, TYP. 36' - 8" SIDE 2ND LEVEL N TOWERCOURT TOWER COURTCONDOMINIUMS CONDOMINIUMS OKW ARCHITECTS TOWER TOWERCOURT COURT 31 05 OKW ARCHITECTS SCALE: 1" = 20' 600 W. Jackson, Suite 250 600 W. Jackson, Suite 250 Chicago,ILIL Chicago, 60661 60661 WINNETKA WINNETKALLC LLC GREEN BAY Court, 1011 Tower RD. WINNETKA, IL Winnetka, IL Architects 0 5' 10' 20' May 12/19/25 07, 2026 Project #: 25057 Project #: 25057 PROJECT Page 108 of 207 FLOOR PLANS 7" 5' - 7" SIDE FRONT PRIVATE TERRACES, TYP. 3' - 2" SIDE PRIVATE TERRACES, TYP. 301 304 4,126 SF STAIR 3,244 SF 185 SF 6' - 6" REAR CORRIDOR 778 SF ELEV STAIR 185 SF 302 303 305 3,150 SF 2,742 SF 3,068 SF PRIVATE TERRACES, TYP. 37' - 7" SIDE 3RD LEVEL N TOWERCOURT TOWER COURTCONDOMINIUMS CONDOMINIUMS OKW ARCHITECTS TOWER TOWERCOURT COURT 32 06 OKW ARCHITECTS SCALE: 1" = 20' 600 W. Jackson, Suite 250 600 W. Jackson, Suite 250 Chicago,ILIL Chicago, 60661 60661 WINNETKA WINNETKALLC LLC GREEN BAY Court, 1011 Tower RD. WINNETKA, IL Winnetka, IL Architects 0 5' 10' 20' May 12/19/25 07, 2026 Project #: 25057 Project #: 25057 PROJECT Page 109 of 207 FLOOR PLANS 4' - 4" SIDE 3' - 2" PRIVATE TERRACES, TYP. SIDE 401 403 PRIVATE TERRACES, TYP. 3,721 SF STAIR 2,871 SF 185 SF 5' - 9 3/4" REAR CORRIDOR 778 SF ELEV STAIR 185 SF 402 303 404 3 3/4" 2,744 SF 2,742 SF 2,672 SF FRONT 38' - 0" SIDE 4TH LEVEL N TOWERCOURT TOWER COURTCONDOMINIUMS CONDOMINIUMS OKW ARCHITECTS TOWER TOWERCOURT COURT 33 07 OKW ARCHITECTS SCALE: 1" = 20' 600 W. Jackson, Suite 250 600 W. Jackson, Suite 250 Chicago,ILIL Chicago, 60661 60661 WINNETKA WINNETKALLC LLC GREEN BAY Court, 1011 Tower RD. WINNETKA, IL Winnetka, IL Architects 0 5' 10' 20' May 12/19/25 07, 2026 Project #: 25057 Project #: 25057 PROJECT Page 110 of 207 ROOF PLAN 49' - 8" T/O PARAPET ROOFTOP SOLAR ARRAY 55' - 3" T/O ROOF ACCESS 46' - 5" 17' - 4" ROOF 52' - 6" REAR MECHANICAL UNITS 38' - 1" 48' - 11" T/O BELOW T/O ELEVATOR OVERRUN PARAPET 53' - 5" T/O MECHANICAL SCREENING 12' - 10" FRONT 37' - 3 3/4" SIDE N TOWERCOURT TOWER COURTCONDOMINIUMS CONDOMINIUMS OKW ARCHITECTS TOWER TOWERCOURT COURT 34 08 OKW ARCHITECTS SCALE: 1" = 20' 600 W. Jackson, Suite 250 600 W. Jackson, Suite 250 Chicago,ILIL Chicago, 60661 60661 WINNETKA WINNETKALLC LLC GREEN BAY Court, 1011 Tower RD. WINNETKA, IL Winnetka, IL Architects 0 5' 10' 20' May 12/19/25 07, 2026 Project #: 25057 Project #: 25057 PROJECT Page 111 of 207 BUILDING ELEVATIONS MTL-07 TOP OF STAIR ACCESS 55' - 3" TOP OF PARAPET MTL-04 49' - 8" BR-01 ROOF ST-01 46' - 5" LEVEL 04 36' - 4" BR-01 MTL-03 LEVEL 03 24' - 8" MTL-02 ST-01 LEVEL 02 13' - 0" ST-01 ST-01 GREEN BAY RD TOWER CT ST-02 GROUND LEVEL 0' - 0" FB-01 ST-01 MTL-01 ST-02 BR-01 SOUTH ELEVATION 1 SCALE: 1/16" = 1'-0" MTL-01 MTL-02 MTL-05 TOP OF STAIR ACCESS MTL-04 MTL-07 55' - 3" TOP OF PARAPET BR-01 BR-01 49' - 8" MTL-02 ROOF 46' - 5" MTL-03 LEVEL 04 BR-01 36' - 4" ST-01 LEVEL 03 MTL-04 MTL-04 24' - 8" LEVEL 02 13' - 0" GROUND LEVEL ST-01 0' - 0" FB-01 ST-02 ST-02 WEST ELEVATION MTL-01 MTL-06 MTL-01 MTL-05 ST-01 2 SCALE: 1/16" = 1'-0" MTL-04 TOWER COURT CONDOMINIUMS OKW ARCHITECTS TOWER COURT TOWER COURT CONDOMINIUMS 600 W. OKW Jackson, Suite 250 ARCHITECTS Chicago, IL 600 W. 60661 Jackson, Suite 250 SCALE: 1/16" = 1' 0" TOWER COURT WINNETKA LLC 1011 Tower Court, Winnetka, IL 35 09 Architects Chicago, IL 60661 0' 4' 8' 16' WINNETKA LLC GREEN BAY RD. WINNETKA, IL May 07, 2026 Project #: 25057 12/19/25 Project #: 25057 Page 112 of 207 BUILDING ELEVATIONS MTL-07 TOP OF STAIR ACCESS 55' - 3" TOP OF PARAPET MTL-04 49' - 8" BR-01 BR-01 ROOF 46' - 5" MTL-03 MTL-03 ST-01 LEVEL 04 36' - 4" MTL-02 ST-01 NEIGHBORING BUILDING LEVEL 03 OUTLINE 24' - 8" BR-01 LEVEL 02 13' - 0" BR-01 ST-01 TOWER CT GREEN BAY RD ST-01 GROUND LEVEL EXISTING EGRESS DOOR MTL-04 0' - 0" ST-02 NORTH ELEVATION ST-01 1 SCALE: 1/16" = 1'-0" MTL-07 TOP OF STAIR ACCESS 55' - 3" TOP OF PARAPET MTL-03 49' - 8" BR-01 MTL-02 ROOF 46' - 5" ST-01 LEVEL 04 36' - 4" MTL-03 LEVEL 03 MTL-03 24' - 8" MTL-02 LEVEL 02 ST-02 13' - 0" GROUND LEVEL 0' - 0" EAST ELEVATION BR-01 2 ST-01 SCALE: 1/16" = 1'-0" TOWERCOURT TOWER COURTCONDOMINIUMS CONDOMINIUMS OKW ARCHITECTS TOWER TOWERCOURT COURT OKW ARCHITECTS 600 W. 600 W. Chicago, Jackson, Suite 250 Jackson, Chicago, IL 60661 Suite 250 IL 60661 SCALE: 1/16" = 1' 0" 0' 4' 8' 16' WINNETKA LLC WINNETKA LLC GREEN 1011 Tower Winnetka, IL RD. WINNETKA, BAY Court, 36 10 Architects May 12/09/25 07, 2026 Project #: 25057 Project #: 25057 Page 113 of 207 BUILDING SECTIONS 48' - 11" TOP OF STAIR ACCESS T/O ELEVATOR OVERRUN 55' - 3" TOP OF PARAPET 49' - 8" ROOF 46' - 5" 4TH FLOOR RESIDENTIAL LEVEL 04 36' - 4" SIGHTLINE 3RD FLOOR RESIDENTIAL LEVEL 03 24' - 8" 2ND FLOOR RESIDENTIAL LEVEL 02 13' - 0" GROUND FLOOR COMMERCIAL GREEN BAY RD TOWER CT METRA RAIL LINE GROUND LEVEL 0' - 0" LOWER LEVEL PARKING LOWER LEVEL -10' - 6" SOUTH PROPERTY LINE 200' - 0" TOP OF STAIR ACCESS 55' - 3" TOP OF PARAPET 49' - 8" ROOF 46' - 5" SIGHTLINE LEVEL 04 36' - 4" 3RD FLOOR RESIDENTIAL LEVEL 03 24' - 8" 2ND FLOOR RESIDENTIAL LEVEL 02 13' - 0" GROUND LEVEL DRIVE AISLE COMMERCIAL PARKING GROUND LEVEL RAMP LOWER LEVEL 0' - 0" PARKING LOWER LEVEL -10' - 6" EAST PROPERTY LINE 105' - 0" TOWERCOURT TOWER COURTCONDOMINIUMS CONDOMINIUMS OKW ARCHITECTS TOWER TOWERCOURT COURT 37 NOT TO SCALE OKW ARCHITECTS 600 W. Jackson, Suite 250 600 W. Jackson, Suite 250 Chicago,ILIL Chicago, 60661 60661 SCALE: 1" = 30' WINNETKA WINNETKALLC LLC CONCEPTUAL SITE SECTIONS GREEN BAY Court, 1011 Tower RD. WINNETKA, IL Winnetka, IL 11 Architects 0 7.5' 15' 30' May 12/09/25 07, 2026 Project #: 25057 Project #: 25057 Page 114 of 207 SUN STUDY SUMMER 9AM FALL 9AM WINTER 9AM SUMMER 12PM FALL 12PM WINTER 12PM SUMMER 3PM FALL 3PM WINTER 3PM TOWERCOURT TOWER COURTCONDOMINIUMS CONDOMINIUMS OKW ARCHITECTS TOWER TOWERCOURT COURT 38 19 OKW ARCHITECTS 600 W. Jackson, Suite 250 600 W. Jackson, Suite 250 Chicago,ILIL Chicago, 60661 60661 WINNETKA WINNETKALLC LLC GREEN BAY Court, 1011 Tower RD. WINNETKA, IL Winnetka, IL Architects May 12/09/25 07, 2026 Project #: 25057 Project #: 25057 Page 115 of 207 STREET ELEVATION GREEN BAY ROAD ELEVATION TOWER COURT CONDOMINIUMS OKW ARCHITECTS TOWER COURT 600 W. Jackson, Suite 250 Chicago, IL 60661 WINNETKA LLC 1011 Tower Court, Winnetka, IL 39 May 07, 2026 Project #: 25057 Page 116 of 207 CONTEXTUAL REFERENCES ON GREEN BAY RD. FABRIC AWNINGS VARIETY OF BRICK COLOR AND PATTERNS DOUBLE HUNG WINDOWS W/ MUNTIN PATTERN A VARIETY OF TUDOR, DECO, CLASSICAL, AND ITALIANATE STYLES LARGE, OPEN STOREFRONTS FLUTED STONEWORK CORNICE DETAILS TOWER COURT CONDOMINIUMS OKW ARCHITECTS TOWER COURT 600 W. Jackson, Suite 250 Chicago, IL 60661 WINNETKA LLC 1011 Tower Court, Winnetka, IL 40 May 07, 2026 Project #: 25057 Page 117 of 207 PRIMARY ARCHITECTURAL COMPONENTS - WEST CORNER ELEVATION METAL COPING PARAPET SINGLE HUNG 49' - 8" WINDOWS ROOF 46' - 5" STONE CORNICE DECORATIVE CAPITALS FOURTH FLOOR STONE FRAME 26' - 4" AROUND WINDOWS DECORATIVE METAL BALCONIES AND RAILING BRICK DETAILS BRICK NICHES THIRD FLOOR 24' - 8" STONE PILASTERS STONE ARCADE DECORATIVE PANEL BRONZE PORTAL FABRIC AWNINGS SECOND FLOOR 13' - 0" FLUTED PILASTERS GRANITE BASE TOWER COURT CONDOMINIUMS OKW ARCHITECTS TOWER COURT 600 W. Jackson, Suite 250 Chicago, IL 60661 WINNETKA LLC 1011 Tower Court, Winnetka, IL 41 May 07, 2026 Project #: 25057 Page 118 of 207 PRIMARY ARCHITECTURAL COMPONENTS - CONDO ENTRY METAL COPING SINGLE HUNG WINDOWS PARAPET 49' - 8" STONE FRAME ROOF AROUND WINDOWS 46' - 5" STONE CORNICE FOURTH FLOOR 26' - 4" BRICK NICHES THIRD FLOOR 24' - 8" SECOND FLOOR 13' - 0" STONE CONDO GRANITE BASES STONE PILASTERS FLUTED PILASTERS ENTRY TOWER COURT CONDOMINIUMS OKW ARCHITECTS TOWER COURT 600 W. Jackson, Suite 250 Chicago, IL 60661 WINNETKA LLC 1011 Tower Court, Winnetka, IL 42 May 07, 2026 Project #: 25057 Page 119 of 207 SIGNAGE ELEVATION 10' - 8" 6' - 3" LEVEL 02 LEVEL 02 13' - 0" 13' - 0" 1' - 7" 1' - 7" SIGN AREA* 16.9 SF SIGN AREA* 9.9 SF GROUND LEVEL GROUND LEVEL 0' - 0" 0' - 0" 6' - 0" LEVEL 02 13' - 0" 1' - 7" LEVEL 02 SIGN AREA* 13' - 0" 9.5 SF SIGN AREA** 13' - 0" 20.58 SF 1' - 2" *SIGN DESIGN BY OTHERS, FINAL DESIGN NOT TO EXCEED SIZE SHOWN GROUND LEVEL **FONT FOR REFERENCE ONLY, EXACT ADDRESS TBD 0' - 0" TOWER COURT CONDOMINIUMS OKW ARCHITECTS TOWER COURT 600 W. Jackson, Suite 250 Chicago, IL 60661 N WINNETKA LLC TOWER 1011 COURT CONDOMINIUMS Tower Court, Winnetka, IL 43 TOWER COURT 18 OKW ARCHITECTS May 07, 2026 Project #: 25057 SCALE: 1/8" = 1' 0" 600 W. Jackson, Suite 250 Architects Chicago, IL 60661 0' 2' 4' 8' WINNETKA Page 120 of 207 LLC GREEN BAY RD. WINNETKA, IL 01/27/26 Project #: 25057 PROJECT VIEW FROM SW CORNER TOWER COURT CONDOMINIUMS OKW ARCHITECTS TOWER COURT 600 W. Jackson, Suite 250 Chicago, IL 60661 WINNETKA LLC 1011 Tower Court, Winnetka, IL 44 May 07, 2026 Project #: 25057 Page 121 of 207 VIEW FROM GREEN BAY RD. TOWER COURT CONDOMINIUMS OKW ARCHITECTS TOWER COURT 600 W. Jackson, Suite 250 Chicago, IL 60661 WINNETKA LLC 1011 Tower Court, Winnetka, IL 45 May 07, 2026 Project #: 25057 Page 122 of 207 VIEW FROM NW CORNER TOWER COURT CONDOMINIUMS OKW ARCHITECTS TOWER COURT 600 W. Jackson, Suite 250 Chicago, IL 60661 WINNETKA LLC 1011 Tower Court, Winnetka, IL 46 May 07, 2026 Project #: 25057 Page 123 of 207 VIEW FROM SE CORNER TOWER COURT CONDOMINIUMS OKW ARCHITECTS TOWER COURT 600 W. Jackson, Suite 250 Chicago, IL 60661 WINNETKA LLC 1011 Tower Court, Winnetka, IL 47 May 07, 2026 Project #: 25057 Page 124 of 207 CONTEXTUAL STUDIES TOWER COURT CONDOMINIUMS OKW ARCHITECTS TOWER COURT 600 W. Jackson, Suite 250 Chicago, IL 60661 WINNETKA LLC 1011 Tower Court, Winnetka, IL 48 May 07, 2026 Project #: 25057 Page 125 of 207 BUILDING MATERIALS MTL-01,02,04,05,06 BRONZE ALUMINUM ST-02 GRANITE WALL BASE MTL-03 SUEDE ALUMINUM RED, SAND FINISH MTL-04 BUFF ANTIQUE BRASS BR-01 ST-01 FACE BRICK CUT STONE TAG DESCRIPTION COLOR MANUFACTURER MTL-07 BR-01 FACE BRICK RED OR EQUAL GLENN-GARY MID ATLANTIC OR EQUAL PRE-FINISHED METAL ST-01 CUT STONE BUFF OR EQUAL ARRISCRAFT OR EQUAL ST-02 STONE BASE GREY OR EQUAL ARCHITECTURAL CAST STONE OR EQUAL MTL-01 ALUMINUM FRAMED STOREFRONT BRONZE OR EQUAL KAWNEER OR EQUAL MTL-02 ALUMINUM FRAMED WINDOW BRONZE OR EQUAL MARVIN WINDOWS AND DOORS OR EQUAL MTL-03 ALUMINUM RAILING SUEDE OR EQUAL CUSTOM FABRICATION FB-01 FABRIC CLOTH MTL-04 ALUMINUM COPING BRONZE OR EQUAL PAC-CLAD OR EQUAL MTL-05 STOREFRONT DOOR PORTAL/SIGNAGE ANTIQUE BRASS OR EQUAL PAC-CLAD OR EQUAL MTL-06 METAL PANELING BRONZE OR EQUAL PAC-CLAD OR EQUAL MTL-07 PRE-FINISHED METAL SILVER OR EQUAL CITYSCAPES OR EQUAL FB-01 FABRIC AWNING STORM OR EQUAL SUNBRELLA OR EQUAL TOWER COURT CONDOMINIUMS OKW ARCHITECTS TOWER COURT 600 W. Jackson, Suite 250 Chicago, IL 60661 WINNETKA LLC 1011 Tower Court, Winnetka, IL 49 May 07, 2026 Project #: 25057 Page 126 of 207 ATTACHMENT B EXCERPT OF MINUTES WINNETKA VILLAGE COUNCIL REGULAR MEETING October 21, 2025 (Approved: December 2, 2025) A record of a legally convened meeting of the Council of the Village of Winnetka, which was held at Council Chambers on Tuesday, October 21, 2025, at 7:00 PM. 1) Call to Order. President Dearborn called the meeting to order at 7:00 PM. Village Manager Kristin Kazenas called the roll. Present: Trustees Kirk Albinson, Rob Apatoff, Kim Handler, Scott Myers and Bridget Orsic. Absent: Trustee Tina Dalman. Also present: Village Attorney Peter Friedman, Assistant Community Development Director Ann Klaassen, Sustainability Coordinator Elyse Steiner and approximately 35 persons in the audience. 9) Discussion. a) Tower Court Condos Concept Review Assistant Community Development Director Ann Klaassen advises Council of a planned development concept plan application submitted by OKW Architects regarding a four- story mixed use planned development. The four-story mixed use development consists of 15,400 square feet of commercial space, approximately 15 residential condominium units on the three upper levels and a total of 36 parking spaces consisting of 7 spaces at street level and 29 spaces on the lower underground level. Ms. Klaassen provides information regarding the planned development process; concept plan review, preliminary plan review, and final plan review, information regarding the proposed site including zoning, commercial uses, and comprehensive plan standards. Additionally, Ms. Klaassen states the requirements regarding rezoning, demolition, plat of consolidation, zoning specifics, and special use permit requirements regarding parking and parking exceptions. Jon Talty, CEO of OKW Architects, provides Council information regarding property specifics, collaboration of residential and commercial use, consideration of building mass, intention of project to enhance vibrancy, residential specifications, proposed footprint, matters related to parking, architectural components, and high demand for condominiums. Council discusses residential unit specifications, building amenities, vehicular and pedestrian traffic, commercial and residential components, architectural design, building mass, and parking concerns. Public Comment Katie Stevens expresses concerns regarding parking and requests reconsideration of the building height. Ted Wynnychenko suggests lower level parking to accommodate both residential and commercial parking. Joanna Caratz requests additional information regarding access to the roof garden and outdoor space. Council provides feedback regarding parking consideration, consideration of setback requirements, access for pedestrian, bicycle, and vehicular traffic, accommodation of emergency vehicle access, and Page building mass and height limitations. 127 of 207 Agenda Item Executive Summary TITLE: Tower Court Condos Concept Review PRESENTER: Ann Klaassen AGENDA DATE: October 21, 2025 CONSENT: No ITEM TYPE: Presentation ITEM HISTORY: None EXECUTIVE SUMMARY: On October 21, 2025, the Village Council is scheduled to consider a planned development concept plan application filed by OKW Architects (the “Applicant”), as the designee of the property owner, Tower Court Winnetka LLC (the “Owner”), who owns 901-905 Green Bay Road and 1007-1011 Tower Court. The Owner also has under contract 907-909 Green Bay Road and 911-913 Green Bay Road, which together with the other properties make up the Subject Property. The Applicant is also the designated architect for the project. The Applicant has submitted for concept plan review by the Village Council a four-story mixed-use planned development for the Subject Property, which consists of the following elements: 1. Ground floor level of approximately 15,400 square feet of commercial space; 2. Approximately 15 residential condominium units on the three upper levels; and 3. A total of 36 parking spaces consisting of 7 spaces at street level and 29 spaces on the lower (underground) level. Attached is a separate staff report providing further details regarding the Applicant's request. Included in the staff report and attachments is additional information regarding the Applicant. RECOMMENDATION: At the October 21, 2025, Village Council meeting, staff recommends that the Village Council review the Applicant’s concept plan application, and that Council members provide individual comments, suggestions or recommendations on the proposed mixed-use development. Page 128 of 207 ATTACHMENTS: 1. Memorandum: Tower Court Condos Concept Plan 2. Applicant's Concept Plan Application Materials 3. Existing Photos of Subject Property Page 129 of 207 ATTACHMENT 1 MEMORANDUM VILLAGE OF WINNETKA COMMUNITY DEVELOPMENT DEPARTMENT TO: VILLAGE COUNCIL FROM: ANN KLAASSEN, ASSISTANT DIRECTOR DATE: OCTOBER 15, 2025 SUBJECT: 901-913 GREEN BAY ROAD & 1007-1011 TOWER COURT TOWER COURT CONDOMINIUMS - PLANNED DEVELOPMENT CONCEPT PLAN REVIEW (CASE NO. 25-19-PD) INTRODUCTION On October 21, 2025, the Village Council is scheduled to consider a planned development concept plan application filed by OKW Architects (the “Applicant”), as the designee of the property owner, Tower Court Winnetka LLC (the “Owner”), who owns 901-905 Green Bay Road and 1007-1011 Tower Court. The Owner also has under contract 907-909 Green Bay Road and 911-913 Green Bay Road, which together with the other properties make up the Subject Property. The Applicant is also the designated architect for the project. The Applicant has submitted for concept plan review by the Village Council a four-story mixed-use planned development for the Subject Property, which consists of the following elements: a) Ground floor level of approximately 15,400 square feet of commercial space; b) Approximately 15 residential condominium units on the three upper levels; and c) A total of 36 parking spaces consisting of 7 spaces at street level and 29 spaces on the lower (underground) level. A Planned Development is required to construct a new building on parcels that have a combined area of at least 10,000 square feet and are located in either of the multifamily residential zoning districts or the commercial zoning districts. The Applicant’s concept plan application materials are included in Attachment 2. Figure 1 Proposed Concept Plan – Conceptual Green Bay Road Elevation Page 1 Page 130 of 207 Page 131 of 207 Page 132 of 207 Page 133 of 207 Figure 5 – Concept Plan – Ground Floor Plan Development of the architecture of the project is still preliminary. The Applicant notes that the style will “speak to the eclectic context of Hubbard Woods and compliment, not dominate the streetscape.” The proposed building materials include brick and stone on all four sides. During the preliminary plan review process, the Applicant will need to provide further details regarding the design of all building facades. Figure 6 – Concept Plan – Green Bay Road Elevation Page 5 Page 134 of 207 Figure 7 – Concept Plan – Drive Aisle Elevation (South) REQUIRED ZONING RELIEF Based upon staff’s initial review of the concept plan submitted to date, the following zoning and subdivision relief has been identified; additional relief may be necessary as the plans evolve and become more detailed: A. Approval of a Plat of Consolidation to create one Lot of Record; B. Map Amendment to rezone the 1007-1011 Tower Court parcel and a portion of the 901-905 Green Bay Road parcel from D-Light Industrial to C-2 General Retail Commercial; C. Approval of a Planned Development for a mixed-use development, which includes consideration and approval of the following special uses and exceptions from the requirements of the Zoning Ordinance: a. The maximum building height allowed is 45 feet and 4 stories; the Applicant proposes a four- story building with a penthouse that is 62’-0” to the top of the penthouse. b. The maximum front yard setback shall be no more than three feet; the Applicant proposes the building to be setback more than three feet from portions of the property line along Green Bay Road. c. No side yard is required, but when a side yard is provided it must be at least three feet; the Applicant proposes a portion of the building to be setback less than three feet from a portion of the north property line. d. Building levels at the fourth level or higher must be setback 10 feet from the front property line; the Applicant proposes a setback at the fourth level less than 10 feet from the Green Bay Road property line. e. The minimum required number of on-site parking spaces is 61; 30 spaces for the residential units and 31 for the commercial uses. The Applicant proposes a total of 36 spaces; 29 below- grade spaces for the residential units and 7 ground-level spaces for guest parking and commercial tenant use. f. The proposed parking located on the ground-level requires special use approval. g. The interior design office (Rebel House Design) on the ground level requires special use approval as a portion of the use would be located within Commercial Overlay District. Given the development would consist of commercial space greater than 2,500 square feet, the development is required to provide parking at 2 spaces per 1,000 square feet of gross floor area for the commercial space. For calculating the number of required parking spaces, gross floor area is “…measured from the interior faces of the exterior walls, excluding areas used for the storage of merchandise or materials, mechanical equipment rooms, rest rooms, common area elements, including without limitation hallways, and areas used for off street-parking and loading…” A calculation of the commercial Page 6 Page 135 of 207 gross floor area will be completed upon submittal of more detailed plans. Based on the concept plans submitted, the total square footage of first floor commercial space requires 31 on-site parking spaces. The Applicant is proposing 7 commercial spaces that would also be used as guest parking for the residential units; therefore, an exception is required. With respect to the residential units, the Zoning Ordinance requires 1.25 spaces per 1-bedroom unit, 1.5 spaces per 2-bedroom unit, and 2 spaces per 3-bedroom unit. The Applicant is estimating 15 residential units and is proposing 29 parking spaces dedicated to the residential units. The size of the proposed units has not been specified. However, if all 15 units contain 3-bedrooms, 30 on-site parking spaces will be required. This shortage also contributes to the exception from the on-site parking requirements. For reference, on October 6, 2020, the Village Council adopted Ordinance M-14-2020 granting a Special Use Permit to allow Rebel House, LLC to operate an interior design office at 901-905 Green Bay Road. This Special Use Permit is not transferable. To occupy commercial space within the first 50 feet of lot depth from the front property line along Green Bay, Rebel House will need to receive approval of a Special Use Permit. As part of the request for planned development approval requiring exceptions, an applicant must provide compensating benefits. The purpose of the compensating benefits is to advance the Village’s physical, cultural, environmental, and social objectives in accordance with the Comprehensive Plan and other plans and policies. The Applicant has identified on page 14 of the attached concept plan application materials the following: 1. The construction of a new and relevant structure replacing the existing collection of buildings, all in various stages of aging obsolescence, which currently occupy the site. Their purposes are fragmented, and the condition of the buildings require profound investment simply to bring them to current standards. 2. The village has a need for the for-sale, single-level housing typology proposed for the property. These residents offer additional foot-traffic that does not currently exist, for the existing retail, restaurants, and services found in the neighborhood. 3. The project offers modern, ground floor commercial environments to satisfy the current marketplace. This commercial amenity includes higher ceilings, less structural impediments, and the opportunity for indoor/outdoor integration of the spaces. 4. The housing allows Winnetka residents to stay in the community as they downsize from their larger homes. It offers our friends and neighbors the chance to remain connected to their friends, clubs, faith communities, and the fabric of the village. 5. The project will serve as a catalyst for streetscape improvements anticipated for the Hubbard Woods district and will contribute in those improvements as outlined in Teska’s planning. 6. The site will include a single lane, one way connection to the Tower Court alley to the east of the Green Bay Road properties. This cut-through serves as an opportunity to get traffic off Green Bay Road for the proposed valet drop-off for an anticipated restaurant tenant, a direct path to the front door of the condominiums above, and guest parking for visitors of the residents. This connection and activation of the west, south, and east sides of the building will contribute to a more pedestrian friendly experience, connecting this site and others to both Green Bay Road and the train station and park to the north. CONSIDERATION BY VILLAGE COUNCIL Any member of the Village Council may make any comments, suggestions or recommendations regarding the concept plan they deem necessary or appropriate. However, no final or binding action is taken at Page 7 Page 136 of 207 this concept plan review step. Any views expressed during the Village Council’s review of the concept plan are only preliminary and advisory and only the individual views of the member expressing them. Nothing said or done during the concept review shall be deemed to create, or to prejudice, any rights of the Applicant or to obligate the Village Council to approve or deny any preliminary plan application. RECOMMENDATION Staff recommends that the Village Council review the Applicant’s concept plan application, and that Council members provide individual comments, suggestions, or recommendations on the proposed mixed-use development. ATTACHMENTS Attachment 2: Applicant’s Concept Plan Application Materials Attachment 3: Existing Photos of Subject Property Page 8 Page 137 of 207 Page 138 of 207 Page 139 of 207 Page 140 of 207 Page 141 of 207 Page 142 of 207 Page 143 of 207 Page 144 of 207 Page 145 of 207 Page 146 of 207 Page 147 of 207 Page 148 of 207 Page 149 of 207 Page 150 of 207 Page 151 of 207 Page 152 of 207 Page 153 of 207 PLATS OF SURVEY: 901-905 GREEN BAY RD. 907-909 GREEN BAY RD. 911-913 GREEN BAY RD. 1007 TOWER COURT TOWER COURT CONDOMINIUMS OKW ARCHITECTS TOWER COURT 600 W. Jackson, Suite 250 Chicago, IL 60661 WINNETKA LLC PLATS OF SURVEY Green Bay Road, Winnetka, IL 17 October 14, 2025 Project #: 25057 Page 154 of 207 Page 155 of 207 Page 156 of 207 Page 157 of 207 Page 158 of 207 Page 159 of 207 Page 160 of 207 Page 161 of 207 Page 162 of 207 Page 163 of 207 Page 164 of 207 Page 165 of 207 Page 166 of 207 U 2,585 SF 3,750 SF 432 SF 432 SF 2,650 SF 3,300 SF 3,510 SF 432 SF 432 SF UP DN 2ND FLOOR - 5 UNIT SCHEME ROOF PLAN UP UP REBEL HOUSE 3,800 SF 2,330 SF 2,275 SF 2,600 SF 4,000 SF 3,625 SF 2,000 SF 3,000 SF 3,200 SF BASEMENT - 29 PARKING SPACES 4,365 SF FIRST FLOOR - 15,410 SF COMMERCIAL N SECOND FLOOR - 15,800 SF RESIDENTIAL UP UP DN THIRD FLOOR - 15,800 SF RESIDENTIAL FOURTH FLOOR - 15,800 SF RESIDENTIAL ROOF - 1,728 SF RESIDENTIAL TOTAL RESIDENTIAL - 49,128 SF 4TH FLOOR - 4 UNIT SCHEME FIRST FLOOR PLAN 190'-0" U UP DN 2,585 SF 3,750 SF 14 15 16 7 18 19 20 21 22 23 24 25 26 7 28 29 95'-9" 13 12 11 10 9 8 7 6 5 4 3 2 1 2,650 SF 3,300 SF 3,510 SF UP DN UP BASEMENT PLAN 48'-0" 3RD FLOOR - 5 UNIT SCHEME FOR REFERENCE TOWER COURT CONDOMINIUMS OKW ARCHITECTS TOWER COURT 30 NOT TO SCALE 600 W. Jackson, Suite 250 CONCEPTUAL FLOOR PLANS Chicago, IL 60661 WINNETKA LLC Green Bay Road, Winnetka, IL October 14, 2025 Project #: 25057 Page 167 of 207 RESIDENTIAL PARKING REQUIREMENTS ESTIMATED # CONDO UNITS: 15 ONE BEDROOM: 1 41 SPACE / UNIT TWO BEDROOM: 1 21 SPACE / UNIT PARKING SPACES REQUIRED: 30 THREE BEDROOM: 2 SPACES / UNIT PARKING SPACES PROVIDED: 29* * POSSIBILITY OF UP TO 56 PARKING SPACES IF CONDO OWNERS CHOOSE TO FORGO OPTIONAL STORAGE FOR EXTRA PARKING. OPTIONAL OPTIONAL STORAGE STORAGE UP 5 11 11 2 TRASH SPKLR. RAMP OPTIONAL STORAGE UP MECH. ELEC. FOR REFERENCE TOWER COURT CONDOMINIUMS OKW ARCHITECTS TOWER COURT 31 NOT TO SCALE 600 W. Jackson, Suite 250 CONCEPTUAL FLOOR PLANS Chicago, IL 60661 WINNETKA LLC Green Bay Road, Winnetka, IL October 14, 2025 Project #: 25057 Page 168 of 207 TOWER COURT CONDOMINIUMS OKW ARCHITECTS TOWER COURT 600 W. Jackson, Suite 250 Chicago, IL 60661 WINNETKA LLC CONCEPTUAL MASSING FROM ACROSS GREEN BAY RD. Green Bay Road, Winnetka, IL 32 October 14, 2025 Project #: 25057 Page 169 of 207 VIEW LOOKING DOWN VIEW LOOKING SOUTH PROPOSED DRIVE AISLE DOWN GREEN BAY RD. TOWER COURT CONDOMINIUMS OKW ARCHITECTS TOWER COURT 600 W. Jackson, Suite 250 Chicago, IL 60661 WINNETKA LLC CONCEPTUAL MASSING IMAGES Green Bay Road, Winnetka, IL 33 October 14, 2025 Project #: 25057 Page 170 of 207 ATTACHMENT 3 Existing Photos of Subject Property 901-905 Green Bay Road (Rebel House & Red Spade – second floor) and 907-909 Green Bay Road (Bella Bleu Bridal & Alexandra Kaehler Design – second floor) 901-905 Green Bay Road and 901-905 Green Bay Road Page 171 of 207 911-913 Green Bay Road (Munder Skiles) Residence on 911-913 Green Bay Road Parcel (behind Munder Skiles) Page 172 of 207 1007 Tower Court – West Elevation of Europa Motors 1007 Tower Court – South Elevation of Europa Motors Page 173 of 207 Page 174 of 207 Attachment C Design Review Guidelines Excerpts The Village of Winnetka Design Guidelines Amendments • 01/17/2023 - Ordinance MC-01-2023 - Building Signage, pages 19 & 20 Page 175 of 207 Village of Winnetka Design Guidelines Table of Contents Introduction ......................................................................................................................1 Village Character ..............................................................................................................1 East/West Elm Street District ..............................................................................1 Hubbard Woods ...................................................................................................2 Indian Hill ............................................................................................................3 General Guidelines Intent .................................................................................................3 Design Guidelines Building and Architecture.................................................................................................4 I. Contextual Design ...................................................................................................4 II. Uses .........................................................................................................................4 III. Historic Buildings and Building Elements ...............................................................5 IV. Style(s) .....................................................................................................................6 a. English Tudor ...................................................................................................6 b. Georgian ...........................................................................................................6 c. ArtDeco ............................................................................................................6 d. Dutch Colonial .................................................................................................7 e. Contemporary ...................................................................................................7 V. Building Mass...........................................................................................................7 a. Setbacks ............................................................................................................7 b. Height ...............................................................................................................8 c. Roof Forms ......................................................................................................9 VI. Proportion/Scale ....................................................................................................11 a. Horizontal Rhythm ........................................................................................11 b. Vertical Rhythms ...........................................................................................12 c. Facade Articulation ........................................................................................13 d. Fenestration ...................................................................................................14 e. Hierarchy .......................................................................................................15 Page 176 of 207 Village of Winnetka, Illinois VII. Articulation ............................................................................................................16 a. Entries ............................................................................................................16 b. Window and Door Fenestration......................................................................17 c. Building Lighting ..........................................................................................18 d. Building Signage ...........................................................................................19 e. Awnings and Banners ....................................................................................21 f. ADA Compliance ..........................................................................................22 g. Mechanical Equipment ..................................................................................22 VIII. Materials ...............................................................................................................23 a. Primary Facade(s) ..........................................................................................24 b. Secondary Facades ........................................................................................24 c. Roof materials ................................................................................................24 d. Door and Window Materials .........................................................................25 IX. Service, Secondary Facades and Parking Structures a. Service Areas ...................................................................................................26 b. Secondary Facade(s).........................................................................................26 c. Parking Structures ...........................................................................................26 1. Massing .............................................................................................26 2. Proportions and Rhythms ..................................................................26 3. Articulation ......................................................................................27 4. Materials ...........................................................................................27 Public Spaces/Streetscapes ............................................................................................27 X. Pedestrian Zones and Pedestrian Circulation .........................................................27 a. Minimum Sidewalk Width Standards ............................................................28 b. Minimum Sidewalk Material Standard ..........................................................28 c. Streetscape Elements .....................................................................................28 d. Pedestrian Zone Landscaping.........................................................................35 e. Special Pedestrian Zone/Streetscape Conditions............................................40 XI. Vehicular Zone .......................................................................................................42 a. Streets ............................................................................................................42 b. ADA Compliance ...........................................................................................43 c. Parking and Service Areas .............................................................................43 d. Vehicular Zone Landscape ............................................................................48 e. Lighting in Vehicular Use/Parking Areas ......................................................57 f. Special Conditions..........................................................................................58 XII. Multiple Family Residential Use Areas ................................................................59 a. On Green Bay Road........................................................................................59 b. In Business Districts .......................................................................................60 XIII. Institutional Use Areas ...........................................................................................61 Design Guidelines Page 177 of 207 a. Site Landscaping.............................................................................................61 XIV. Village Signage ......................................................................................................62 a. Village Gateway Signage ...............................................................................62 b. Business District Ground Mounted Identity Signs ........................................63 c. Roadway Corridor Identity Signs ...................................................................64 d. Roadway Directional Signs ............................................................................64 e. Street Identity Signs........................................................................................65 f. Business District Directional Signage ............................................................65 g. Regulatory Signs ............................................................................................66 h. Informational Signs .......................................................................................66 XV. Open Space.............................................................................................................67 a. Purpose ...........................................................................................................67 b. Location ..........................................................................................................67 c. Open Space Types ..........................................................................................68 d. Components ....................................................................................................72 e. Location-Oriented Open Space Guidelines ...................................................73 XVI. Submission Requirements ......................................................................................74 Appendix A ...........................................................................................................75 Appendix B ............................................................................................................78 Appendix C ............................................................................................................83 Appendix D............................................................................................................84 Page 178 of 207 Introduction For over thirty years, Winnetka has had a review board that examines proposed designs for commercial, multiple-family, mixed use and institutional (including both public and quasi- public) building projects. In recent years, this has been called the Design Review Board (DRB), whose seven members are appointed by the Village Council. The Village of Winnetka seeks to maintain the high quality of its business districts’ built environment, with development that is attractive and consistent with a pedestrian-oriented town center character. Whether a proposed project is for new development or an improvement to an existing building or landscape, it is important that each proposal enhances the contextual character of its surroundings and contributes positively to the goals of the community. The Comprehensive Plan for the Village of Winnetka, Winnetka 2020, recognizes that the DRB, residents, developers and architects will all benefit from guidelines that encourage high-quality design that is sympathetic to its surroundings. The following guidelines for site and building design are suggestive only and are not intended to supplement or supercede the Village’s Codes or Ordinances nor do they represent a master plan for any immediate development project. Village Character East/West Elm Street District The East/West Elm Street Business District known locally as “Winnetka” is the Village’s main commercial district. The District conveys a strong image throughout the unified composition of the existing streetscape, landscape, land-use transitions and architecture. Visually and symbolically this district, bisected by Green Bay Road and the Union Pacific Train Line, is the heart of Winnetka’s business and civic community. Figure 1 The District’s landscaping and harmonious land use transitions, anchored by Station Park at the intersection of Green Bay Road and Elm Street, help create a district edge and gateway. Neighborhood service and destination stores along with most of the Village’s civic facilities are located here. One of the defining landmarks of this district is the open axis created by Chestnut Court west of Village Hall. Figure 2 1 Introduction/Village Character Page 179 of 207 Village of Winnetka, Illinois The pedestrian-oriented feel of the district is created in a variety of ways. First, the buildings have significant architectural consistency and scale that create an inviting outdoor “room” for pedestrians. Storefronts contain large retail windows and attractive displays, which encourage strolling and window shopping. Sidewalks provide ample room for pedestrian flow and streetscape features including furniture and landscaping. (See figures 1,2,3) Parking is located in several public parking lots and on the street. Loading, servicing and additional parking generally Figure 3 occur in rear alley locations. Hubbard Woods The Hubbard Woods Business District is a linear business district built on both sides of a regional arterial roadway, Green Bay Road. It has a smaller building scale than the East/West Elm Street District, giving it a more intimate feel despite heavier traffic conditions. As with the Elm Street District, the Hubbard Woods District has a pedestrian-oriented, neighborhood retail character. The buildings exhibit architectural consistency, scale and storefront displays that encourage strolling and window shopping. A significant number of multiple-family residential units are located on the upper floors of the retail stores. (See figures 4,5,6) In general, parking is provided on the streets, in alleys behind buildings and in small public lots including a two-level parking structure adjacent to the railroad tracks. Loading and servicing occur in rear alley locations. Hubbard Woods Park and its Gazebo are actively used and provide a major Village gathering area. Figure 4 Figure 5 Figure 6 Design Guidelines 2 Page 180 of 207 Indian Hill The Indian Hill Business District, the southern gateway into the Village, is a predominantly auto-oriented business corridor. South of Winnetka Avenue, the west side of Green Bay Road is composed of predominantly single- story buildings housing a variety of retail uses, while the east side of Green Bay Road abuts the railroad tracks, allowing for parking and buffer landscaping. Circulation/traffic problems and safety hazards, especially for New Trier High School students, exist due to fast- moving traffic, winding roadways, and wide streets. As with the Village’s northern Green Bay Road gateway at Figure 7 Hubbard Woods, the Village identity needs to be communicated through the development of a gateway feature, appropriate wayfinding signs, gateway architecture and unified repetition of streetscape elements. (See figures 7,8) Parking for the existing businesses generally occurs on Green Bay Road. Multiple-family residential parking is provided for in defined off-street lots. Figure 8 General Guidelines Intent The intent of these General Design Guidelines is to provide a standard that can be used to evaluate proposed commercial, mixed-use, multiple-family and institutional development in the Village of Winnetka. These guidelines require that new designs retain a contextual relationship with the existing character of the three individual commercial districts. The individual character of the commercial districts should be maintained and enhanced by careful consideration of the architectural styles, materials, scale, massing, setbacks and articulation and by proper attention to the surrounding landscaping and transitional zones adjacent to residential areas. Throughout the guidelines the terms primary and secondary facades are used. The definitions of those terms are: Primary facades face a street or pedestrian open space. Secondary facades face pedestrian parking areas or alleys. 3 General Guidelines Intent Page 181 of 207 Village of Winnetka, Illinois Design Guidelines Building and Architecture I. Contextual Design Commercial, mixed-use, institutional and multiple-family development projects should reflect an understanding of the immediate site surroundings and the village-wide character. Contextual design reflects existing features including massing, height, setbacks, proportions, scale, roof forms, materials, articulation, lighting, signs and awnings while creating appropriate architectural design. The prevalence of the English Tudor style throughout the Village dictates smaller structural bays and massing, limited building heights, variety in roof forms, mix of materials and special attention to detailing and fenestration proportions and patterns. It is not the intent of these guidelines to recreate traditional architectural styles that do not allow for contemporary architectural designs or materials, but to provide a framework within which good design can flourish in context and enhance the existing Village character. II. Uses The three districts have a mix of uses that includes commercial, mixed-use, institutional and multiple-family facilities. Exclusively commercial buildings make up a small percentage of the structures within the districts. They are typically single-story buildings that house a single retailer with on street frontage and a large expanse of storefront. These buildings are strongly horizontal with large sign bands and varying stylistic detailing. Most buildings in the commercial districts are mixed-use. The architectural designs are based on a traditional two-part structure with retail on the ground floor and offices or residences above. The facades clearly separate the two uses through changes in materials and wall plane as well as changes in fenestration, with large glass storefronts on the street level and punched windows above creating a hierarchy of public versus private spaces. In select locations, where large or awkward site geometry suggest, alternatives to the existing mixed-uses may encourage the use of first floor courtyards or pedestrian ways instead of uninterrupted commercial space. Institutional buildings include a wide variety of building types and uses such as civic buildings (Village Hall), schools, libraries, churches, recreational facilities and utilitarian public works facilities. Most institutional structures located within the Elm Street District are designed in the Classical Revival, Contemporary or Georgian styles. Most schools and churches are located within residential neighborhoods. Typically, institutional structures are freestanding and larger in scale as they represent unique aspects of community life: governmental, religious and educational. The design of institutional buildings, whether new or an alteration to an existing building, should reflect the context of their immediate surroundings and respect the existing neighborhood while identifying their function. Design Guidelines 4 Page 182 of 207 Multiple-family buildings are structures limited to residential use only including condominiums, townhomes and apartment buildings. III. Historic Buildings & Building Elements Although the Village of Winnetka developed from a plat recorded by Charles E. Peck in the 1850’s, many of the commercial structures in the main shopping districts were built during the 1920’s. Future project designs should reinforce the established character, massing and scale. New developments and alterations are encouraged to incorporate historic building elements and forms from adjacent structures in order to maintain a cohesive district. (See figures 9, 10, 11, 12, 13) Figure 9 Figure 10 Figure 11 Figure 12 Figure 13 5 Building & Architecture Page 183 of 207 Village of Winnetka, Illinois IV. Style(s) In Winnetka, a variety of architectural styles has flourished, the most common of these are: a. English Tudor. The most prominent Winnetka architectural style is characterized by a mixture of materials, medieval detailing, human scale and proportion. A typical commercial building has a heavy masonry base with the upper floors articulated by timber and stucco bays and punched windows. Most of the Tudor buildings range from 1-½ to 2 -½ stories in height. The top story is usually concealed under a steeply pitched roof interrupted by cross gables and dormers. (See Figure 14 English Tudor figures 14 & 15) b. Georgian. Several prominent institutional Figure 14 – English Tudor buildings reflect the Georgian style, which is characterized by a symmetrical facade, hipped roof with gabled entry, classical detailing and the use of quoins to articulate the corners. Georgian buildings are generally constructed of brick with limestone detailing. The fenestration pattern on Georgian buildings is typically small stacked punched openings with double- hung, divided-light windows. (See figure 16) Figure 15 English Tudor c. Art Deco. Art Deco is a style of decoration consisting largely of low-relief geometrical designs of straight lines, zigzags, chevrons and stylized floral motifs. The style is a conscious expression of modernity and the machine age. Exterior architectural materials vary from smooth faced concrete and stone to metal, terra cotta and glass. Predominant Midwest Art Deco buildings, as exemplified in Winnetka, are built of dressed limestone and are generally horizontal, most often single story commercial structures with low-relief stylized designs at the sign band. (See figure 17) Figure 16 Georgian Design Guidelines 6 Page 184 of 207 d. Dutch Colonial. Dutch Colonial shares some common elements with English Tudor most notably the roofline. Most colonial buildings range from 1 ½ to 2 stories and have a steeply pitch roof with a gable or dormer interrupting the roofline. Dutch Colonial buildings are usually constructed of brick with simple abstract detailing. (See Figure 17 Art Deco figure 18) e. Contemporary. Contemporary architectural styles include buildings that were built within the past forty years and vary greatly in design, materials and detailing. They range in height from 2-½ to 4 stories. Many have not reflected Winnetka’s character in terms of scale or design. The more recent contemporary buildings incorporate historic elements into facade articulation. (See figure 19) Figure 18 Dutch Colonial V. Building Mass Massing of a building should acknowledge the size of adjacent structures. Any changes in massing should relate to the primary and secondary building facades, the structural bay rhythms and the hierarchy of the use of the building. Massing of additions should respect the existing building volumes and contribute to the identity and hierarchy of the original building. Figure 19 Contemporary a. Setbacks: Setbacks are defined as the relationship of the facade to the property line. Upper level setbacks on the primary and secondary street fronts are not allowed except as indicated below. Commercial and Mixed Use: A continuous “streetwall” along primary commercial thoroughfares should be provided and building facades should be located to create this uniform setback. While commercial zoning standards provide for front setbacks of up to 3 feet, new developments should align with adjacent buildings along the property line. In the Indian Hill Business District, restricted sidewalk widths may warrant a setback of 1 to 3 feet, to be evaluated on a case by case basis. Setbacks should be provided where appropriate to enhance landscaped areas and/or widen restricted sidewalks to provide appropriate widths. The main facade should be orientated to the primary commercial thoroughfare. 7 Building & Architecture Page 185 of 207 Village of Winnetka, Illinois Upper level setbacks, which create continuous open terraces, are not allowed on the primary facades. Small setbacks (such as 10’-0” maximum), no greater than one bay width (maximum 20’-0”) with a continuous roof eave line, will be considered on upper floors only. The ratio of upper level setbacks must be considered with regard to the building’s proportions and scale. No continuous upper level setbacks or corner setbacks will be considered. Roof gables should be in the same plane as the primary building facade except for the 6”-12” projections allowed under Section VI.c, Articulation. Roof eaves should 10’-0” meet and project beyond the primary facade to create horizontal rhythm. (See figure 20) Buildings located on corner 11’-0” sites should hold the property line or “streetwall” at the intersections of both thoroughfares. Slightly rounded or angled 14’-0” building corners at intersections are acceptable to enhance the pedestrian flow and visibility. Figure 20 Institutional: Institutional buildings are located throughout the village in various zoning districts and are most often freestanding structures. They frequently function as a transitional element between zoning districts. If an institutional building is located within a commercial district, the mass of the building is encouraged to break from the “streetwall”, creating open public space, establishing the hierarchy of the building within its context and creating both a focal point and a visual relief within the commercial district. Additions to existing institutional structures should respect the established setbacks of the original building and should be sensitive to the context of the surrounding zoning area, particularly residential neighborhoods. Multiple-family Residential: Multiple-family residential buildings are generally located along Green Bay Road, creating a transition between a commercial thoroughfare and single-family residential zones. The B-1 and B-2 multiple-family residential zoning districts call for a 25’-0” front yard setback whereas multiple-family buildings within the C-1 and C-2 zones require a 1’-0” to 3’-0” setback. New multiple- family developments occurring at the edge of the C-1 and C-2 districts should have a front yard setback of 1’-0” to 6’-0” to create a transition between the commercial and residential districts. The primary facade should be located on the main thoroughfare for all zoning districts. b. Height: Existing building heights in the commercial districts vary between single-story commercial buildings to 3-story mixed-use and institutional structures. Design Guidelines 8 Page 186 of 207 Commercial and Mixed Use: The existing building heights are consistent at 2-3 stories within the heart of the commercial district. Buildings of this height are appropriately located within dense pedestrian districts and along Green Bay Road whereas buildings of 1 and 2 stories function well as transitions to single-family residential areas. Single- story buildings are appropriately located along the automobile-oriented south end of Green Bay Road at Indian Hill. Based on existing building heights, new buildings or building additions should have transitional elements or bays such that the new building height will not vary more than ½ story lower than the immediate adjacent buildings while complying with the requirements of the zoning ordinance. (See figure 21) The current zoning restricts all building heights to 2 ½ stories within the B and C zoning districts. Figure 21 Institutional: The height of institutional buildings will vary depending on the use and location of the structure. Institutional buildings located within the commercial zoning districts (C-1 and C-2) are typically more monumental in scale and massing, and the minimum height to the eave line or parapet should not be less than 30% of the length of the primary facade or 25 feet, whichever is greater. The maximum height must conform to the existing zoning requirements. The height of institutional buildings located in the multiple-family (B-1 and B-2) or single family (R-1 through R-5) zones should be sensitive to the surrounding buildings and must conform to the existing zoning requirements. Additions to existing facilities should respect the existing heights and not differ from the established eave line by more than ½ story. Additions and alterations should be sensitive to the context of the surrounding zoning area. Multiple-family Residential: Many of the older multiple-family residential buildings are built to the outdated zoning standard height of four stories, whereas the height of recent and new multiple-family developments is limited to 35 feet and 2 ½ stories. c. Roof Forms: Roof forms contribute to the massing, scale and proportions of all buildings. Manipulation of the form can help distinguish between residential, commercial and institutional structures. Sloped roof systems, while containing the commercial ½ story defined by the zoning ordinance, should have eave lines that extend to the perimeter of the building eliminating upper story setbacks at the primary elevation. The continuous length of any roof on a primary facade should be limited to 9 Building & Architecture Page 187 of 207 Village of Winnetka, Illinois 20’0”, without a break in plane using dormers, gables or hip roofs. These should be designed in conjunction with the Vertical Rhythm, Section VIb. Commercial and Mixed Use, Multiple-family Residential: The predominant roof form within the districts is a pitched shingle roof with cross gables, projecting eave line and brackets reflecting the structural bay rhythm of the building. Variations of the gable and roof pitch contribute to the general breakdown of the building mass and contribute to the steady streetwall rhythm. No roof pitch is to be greater than 60 degrees (21:12) or less than 35 degrees (8:12). (See figures 22 & 23) Figure 22 Figure 23 Institutional: The roofs of the institutional buildings should have shallower sloped roofs than the commercial structures and be composed of basic gable, hipped or flat roofs. The pitch of sloped roof systems should range between 25 degrees (6:12) and 45 degrees (12:12). Contextual sloped and gabled roofs are preferred. Flat roof systems must be concealed from view by a decorative parapet. The roof structures should not break up the mass of the structure, but emphasize overall volume through a uniform ridge, eave or parapet line. A cross or open gable can be introduced to provide hierarchy to the facade and identify the entry or wings. Additions to institutional structures should respect the existing roof form and slope, however, the height of the ridge, eave and parapet line can vary per the height restrictions outlined in Section V.b. (See figures 24 & 25) Design Guidelines 10 Page 188 of 207 Figure 24 Figure 25 VI. Proportion/Scale Winnetka’s original 1920’s comprehensive plan was designed before the prevalence of the automobile and therefore was pedestrian oriented. Although the automobile dominates life in the 21st century, it is the intent of the Village to retain a positive pedestrian experience within the Village commercial centers. The character of the Village requires that a pedestrian balance be retained and encouraged. Unless noted otherwise, any alteration to the commercial districts must be designed to fulfill this goal. a. Horizontal Rhythm: The breakdown of the building facade into horizontal bands provides human scale and proportion to the facade. The relationship of horizontal banding among buildings can unify the street elevation. Commercial and Mixed Use: The commercial district must convey the hierarchy of the pedestrian experience through the development of horizontal rhythms. The height of the street level elevations (floor to floor) should be 20% greater than the upper floor to floor dimensions. A building base, middle and top should be strongly articulated through materials, details and changes in the plane of the wall. The retail storefront façade should be differentiated from the facade of the upper stories. (See figure 26) The street and storefront facade should be horizontal, contiguous and harmonious with the adjacent and facing structures. Storefront systems, awnings, and entrance doors should be selected to be harmonious and similar to the adjacent buildings’ scale and proportion. 11 Building & Architecture Page 189 of 207 Village of Winnetka, Illinois EQ. EQ. 10’-0” 11’-0” 14’-0” Figure 26 Institutional: Institutional structures such as civic buildings and churches convey hierarchy through larger massing, scale and proportion. The base of the building should be articulated separately from the upper floors to give the building weight and an appearance of solidity, reliability and endurance. The height of the first floor should be a minimum 20% greater than the height of the upper floors. To add to the formality of an institutional structure, an elevated first floor should be considered while complying with Federal and State ADA requirements (refer to Section VII.f). Additions to existing structures should respect the existing horizontal rhythms in order to maintain and enhance the original scale and proportion of the structure. b. Vertical Rhythms: The breakdown of the building facades into vertical bays creates a sense of progression and scale to the streetwall as well as individual buildings. Vertical rhythms break down the length of a building while unifying the floors from grade to eave. Fenestration patterns will emphasize the vertical rhythms, see Section VI.d. Commercial, Mixed Use, Multi Family Residential: Facades are to be articulated to express a vertical rhythm that is directly related to the structural columns and bays. Structural bays should not exceed 20 feet in width. Structural elements and bays should be architecturally articulated on the facade to add interest, scale, proportion and detail. Structural bays should be recessed and/or projected approximately 6”– 12” to provide a variety of changes of plane, interest in light and shadow and to establish a hierarchy with the architectural elements. Some variation of facade materials from bay to bay is encouraged. No building facade that faces a street or pedestrian open space may have a blank uninterrupted length greater than 20 feet. Institutional: The scale and proportion of institutional buildings should be appropriate to the function and use of the building. The scale of prominent civic buildings such as a village hall or central library would differ from a recreation Design Guidelines 12 Page 190 of 207 center. The facades of prominent civic buildings are to be articulated so as to distinguish them from their context. Emphasis of the vertical rhythms and structural bays should be minimized to provide a larger building mass to establish the hierarchy of the building. Vertical rhythms should reinforce the importance of the structure with 1 to 10 foot projections restricted to larger building masses that span 40-60 feet. The large-scale change in mass will establish hierarchy within the building facade. (See figure 27) Educational, recreational and public works facilities located near or adjacent to a residential district, should provide a contextual design sensitive to the neighborhood. Figure 27 c. Facade Articulation: Articulation is achieved through the combination of materials, introduction of detailing and changes in plane of the facade. Commercial, Mixed Use and Multiple-Family Residential: Facade elements should be recessed and/or projected to provide a variety of changes of plane, interest in light and shadow and to establish a hierarchy with the architectural elements. Building facades are to be proportioned to respect human scale and the existing prevalent scale of the Village’s architecture. No building facade that faces a street or pedestrian open space should have a blank uninterrupted length of wall greater than 20 feet. In addition, the proportion of the fenestration should comply with Section VI.d. Commercial and Mixed Use: Ground floor /storefronts that face public streets, adjacent development or pedestrian open space should be subdivided using fenestration along no less than 60% of the facade. 13 Building & Architecture Page 191 of 207 Village of Winnetka, Illinois Institutional: Civic and religious institutional buildings tend to be larger and the facade articulation should be restrained so that the massing is emphasized. Vertical rhythm should be created by the articulation of stacked windows and doors. d. Fenestration: The pattern of wall penetrations is created by window and door openings. Primary facades are defined as facades facing a street or pedestrian open space. Secondary facades are defined as facades facing pedestrian parking areas or alleys. Windows should be recessed back from the overall plane of the building facade at the window head and sill to create additional articulation and shadow. Strip windows are not allowed. Commercial and Mixed Use: In order to provide a desired proportion of fenestration the following guidelines should be met: Primary facade: At least 60% of the first floor facade is to be windows/storefront or entrances. (See figure 28) At least 25% but no more than 40% of the upper floors are to be windows or doors. (See figures 29 & 30) Note: Percentage is based on the total facade square footage, which is calculated from the top of the first or ground floor to the top of second floor. 10’-0” 10’-0” 11’-0” 11’-0” 14’-0” Figure 28 Figure 29 Figure 30 Secondary facades: At least 25% of the first floor facade is to be windows/storefront or entries. At least 25% of the upper floors are to be windows or doors. Note: Percentage is based on the total facade square footage, which is calculated from the top of the second floor to the underside of roof eave. Design Guidelines 14 Page 192 of 207 Institutional: Since most institutional buildings are freestanding and larger in scale, the fenestration pattern does not vary much between the primary and secondary facades. To provide a desired proportion of fenestration and to promote an appearance of solidity: Ground floor façade: Windows or doors should interrupt 25% but not more the 50% of the wall area. Uninterrupted wall area should not extend for more than 20 feet without the introduction of blind niches or windows. Note: Percentage is based on the total facade square footage, which is calculated from the top of the first or ground floor to the top of second floor. (See figure 31) Figure 31 Upper floor facades: At least 20% but not more the 50% of the upper floor’s wall area should be interrupted by windows. Uninterrupted wall area should not extend for more than 20 feet. Note: Percentage is based on the total facade square footage, which is calculated from the top of second floor to the underside of roof eave. (See figure 31) Multiple-family Residential: In order to provide a desired proportion of fenestration the following guidelines should be met: Ground and upper floor facades: At least 35% but no more the 60% of the façade should be windows or doors. e. Hierarchy: The prioritization of certain building masses, components or elements over others. Commercial and Mixed Use: The hierarchy of public over private spaces should be conveyed by the facade. Public or retail spaces should be open and inviting through the introduction of storefronts with doors integral to the system. Private or office/residential spaces should have a separate entrance articulated independently from the storefront. (See figure 32) 15 Building & Architecture Page 193 of 207 Village of Winnetka, Illinois Institutional: The primary facade should have a distinct public main entrance. Multiple-family Residential: Multiple-family residences should have a distinct and articulated common entrance on the main facade(s). Town homes should have individually articulated entrances. Figure 32 VII. Articulation a. Entries: Proportion, scale, location and details should be used to differentiate public entrances from private or semi-private entrances at all uses. 1. Hierarchy Commercial, Mixed Use and Institutional: The identity of the public entrance should be evident from the public way and differentiated from the semi-public and private entrances. Public entries should have a large-scale approach and be open and inviting whereas semi-public and private entries are integral to the adjacent building facade and more opaque. Multiple-family Residential: Proportion, scale, location and details should be used to differentiate common entrances from private entrances. 2. Location Commercial and Mixed Use: Public entrances should be located along the main thoroughfares and at corners. Private or semi-private entrances should be located either to the side of a single bay building or centrally for a multiple bay building. Institutional: Public entrances, both main and secondary, should be located in a central location on the main facade or along major access routes or vistas. Services entrances should be remotely located from the open public space and not visible from the main public approach. Multiple-Family Residential: Common entries will be oriented toward the main street or thoroughfare. Garage entrances should be oriented toward a secondary street, alley or away from the pedestrian way. Design Guidelines 16 Page 194 of 207 3. Detail Commercial and Mixed Use: Typically, private or semi-private entrances should have a predominately solid door and be set in a masonry opening nearly flush to the building facade whereas the public or storefront doorway should be recessed and have an awning so as to provide protection from the elements for shoppers. Building entrances can be further defined by using subtle streetscape improvements such as pavers. Residential entrances should be clearly identified and dignified. Institutional: Generally the public entrances are detailed to stand out on a facade through the use of articulation and location. In order to be open and inviting, public entrances should incorporate larger expanses of glass than secondary entrances. b. Window and Door Fenestration: Commercial, Mixed Use, Institutional and Multiple-family Residential: Punched single or ganged windows are required at upper floors but not allowed at street level on primary facades in commercial buildings. A combination of ganged and single units within the punched opening is encouraged to provide hierarchy to the facade. It is encouraged that the sill height of upper level windows align with adjacent buildings but should not be higher than 30” above finish floor elevation. See Section VI.d. Mullion and muntin divisions are required to maintain the scale of the districts and reduce Figure 33 large expanses of glass at the upper floors. (See figure 33) Strip windows are not allowed. Commercial and Mixed Use: Storefront windows are required in commercial buildings on the primary facade at street level. Storefront windowsill heights cannot exceed 18”. Secondary facades are encouraged to provide punched display windows to define the hierarchy of the primary facade over the secondary. (See figure 34) Figure 34 17 Building & Architecture Page 195 of 207 Village of Winnetka, Illinois Mixed Use and Multiple-Family Residential: Bay windows are allowed on upper stories of mixed- use buildings if the upper floors are designated residential and on upper stories of multiple-family residential buildings. Bay windows are to project a maximum of 12”. (See figure 35) Figure 35 c. Building Lighting Commercial, Mixed Use, Institutional, Multiple-Family Residential: 1. Exterior Uses and Types: Exterior building lighting should be carefully designed. Incandescent and low voltage lighting may be allowed. Fixtures should be contextual with the building and adjacent building design. Building lighting should focus on providing light on building signs and enhancing architectural details on the facade. All lighting shall be located and shielded from direct visibility from any dwelling or public street per the Winnetka Village Code. Wall lanterns and architectural highlighting should be considered. Sodium and fluorescent lighting is not allowed. (See figures 36 & 37) 2. Sign Illumination: Signs located within 100 feet of Figure 36 the boundary of any residential zoning district may not be illuminated, per the Village Code. 3. Interior: Fluorescent lighting with exposed fluorescent lamps is discouraged in street-level interiors where visible from the public way. Figure 37 Design Guidelines 18 Page 196 of 207 d. Building Signage Commercial signs should reflect the character of the building style, while expressing each store’s individuality. There are several prominent sign styles that are appropriate to Winnetka: surface mounted, pin-mounted, interior, decal and projecting blade signs. Sign materials are limited to painted wood, canvas, architectural glass and metal. Sign color must harmonize with the building upon which it is mounted and adjacent structures. Lettering color can be unique to the image of the retailer/user. Metal sign and plaque material such as brushed bronze, antique bronze, aluminum, stainless steel and painted cast iron or similarly appearing materials are preferred. Highly reflective metallic signs are not allowed. Signs should be lit by marquee or spot lighting; neon lighting is not permitted. Spot lighting should be minimal and unobtrusive and, per the Village Code, the source of illumination shall not be visible from any street, sidewalk or dwelling. Simplified industrial light fixtures are not permitted. Contextual solutions are recommended. The majority of the signs will be mounted within the building’s sign band, defined as the wall area located above the ground floor storefront opening and below the second floor windowsill, and is located a minimum of 8’-0” above grade and a maximum of 15’-0” above grade. (MC-01-2023, amended, 01/17/2023) Signs must comply with the general provisions of the Winnetka Sign Ordinance as well as design provisions contained within these Design Guidelines. 1. Surface mounted commercial signs are either fabricated from painted wood or cast metal plaques and are to be mounted within the sign band or within the storefront transom. The height of the sign is restricted to 75% of the area of the sign band or 14 inches - whichever is less. The sign band of a building consists of the area located above the ground floor storefront opening and below the second floor windowsill, and is located a minimum of 8’-0” and a maximum of 15’-0” above grade. Refer to figures 28, 29, and 30 for location. Surface mounted or pin- mounted signs are not permitted on secondary elevations without a defined sign band. 2. Pin-mounted commercial signs consist of reverse channel, cast metal and flat cut metal letters mounted above the storefront in the masonry sign band or suspended in front of the storefront at the transom or recessed entry. The size of the lettering is restricted so that the height of the letters does not exceed 75% of the height of the sign band or 14 inches - whichever is less. The length of the lettering is to be Figure 38 contained within 75% of the length of the sign band. (See figure 38) 19 Building & Architecture Page 197 of 207 Village of Winnetka, Illinois Figure 39 & 40 3. Projecting blade commercial signs can MC-01-2023, Removed, 01/17/2023 be round, square or vertical, mounted from the face of the building at the second floor level between the windows or at the head of the storefront and are oriented to pedestrian scale. The signs are to be mounted on fixed hardware; no swinging or chain-mounted signs are allowed. The dimensions of the sign are not to exceed 6 square feet (36” high and 24” deep) (See figure 41). If illuminated, the signs should be lit with an unobtrusive light source. Figure 41 4. Incidental wall signs such as building management identification and directory signs should be integrated into a single sign and be constructed of brushed bronze, antique bronze or painted cast iron. Such signs should not be placed on the prominent street front facade and should be directed to public residential entries (MC-01-2023, amended, 01/17/2023) Design Guidelines 20 Page 198 of 207 e. Awnings and Banners Awning scale and proportions are to be appropriate for the building on which they are mounted as well as the adjacent structures. It is highly recommended that awnings be uniform in size, shape (except for arched openings, see “Forms” below) and color in order to unify multiple storefronts within a single building. The length of the awning is to be restricted to the length of the storefront opening; awnings must not continue over masonry piers. The vertical and horizontal dimension should be proportional to the overall projection of the awning. (See figure 42) Figure 42 Awning projection is preferred at 36 inches, but awnings will be considered which range from a minimum of 24 inches to a maximum of 36 inches. Projection depth should match the existing adjacent awnings provided they comply with the acceptable minimum and maximum projection. Awnings should be placed at a minimum height of 8 feet above the sidewalk. If awnings are lit it should be from an outside source; no backlit awnings are allowed. Forms: Awning forms are to conform to the general shape of the opening. Arched openings are to receive ½-round domed awnings, whereas rectangular openings are to receive rectangular, gently sloping; planar forms with closed ends. Valances may be fixed or loose. Mounting: Awnings may be fixed or retractable. Retractable awnings must be kept either in the fully projected position or the fully closed position. Fixed awnings are to have concealed rigid metal frames. Retractable awnings should have a canopy cover and automatic retractable rollers mounted to the building. Underpanels are not desired. Frames should be painted to match or compliment the color of the awning cover material or its underside. Materials: The awning material should be taut, not relaxed. Awning materials may include matte finish painted army duck, vinyl-coated cotton, acrylic-coated polyester, and vinyl-coated polyester or cotton and solution-dyed acrylic. All materials should receive silkscreen, painted, cutout lettering, heat color-transfer, pressure sensitive vinyl films or sewn appliqué signs. Awning signs and logos are limited to a height of six inches, and may be placed on the valence only. 21 Building & Architecture Page 199 of 207 Village of Winnetka, Illinois Colors: Awning and banner colors must take into account the color selection of the surrounding materials, buildings, signs, awnings, and image of the retailer/user and district. All awnings located on the same building must be the same color. Colors should enhance and compliment the building and are restricted to earthtones and primary and secondary colors. Final color selection is contingent on approval by the Design Review Board and compliance with the Village awning ordinance. Banners should be considered as identification of commercial districts. Banners may be location, event, holiday or sponsor specific and can create a unifying thread between the independent districts. Banners are to be mounted on existing poles by fixed brackets and hardware. The Design Review Board must approve the final design. All new or replacement Awnings and Banners must comply with Village Ordinances and the Design Guidelines. f. ADA Compliance: Federal and State regulations require all public spaces to be accessible. Accessibility alterations shall allow access from either the primary or the secondary facade; additions of elevators or ramps should be designed as an integral element of the building. Entrances: Commercial and mixed-use facilities should provide first floor access from the primary or secondary facade. Elevators: Where possible, elevators should be incorporated into the existing building envelope. If physically impossible, the elevator and stair core can be located on the exterior of the building but should be located so as not visible from the main public way. Ramps: Where required, the slope of the ramp should be as gradual as possible to eliminate the need for handrails. Although a 1:12 slope is permitted, 1:20 is encouraged. A ramp should be an integral design element, reflecting the design of the building it serves and surrounding site. This can be accomplished by concealing the ramp behind a low screen wall. g. Mechanical Equipment 1. Location Mechanical Equipment must not be visible from pedestrian view. Roof top equipment should be located either in the center of the roof or in one corner away from the street elevation so as not to be visible from the primary or secondary approach. Design Guidelines 22 Page 200 of 207 2. Screening For at-grade equipment screening, see Sections IX.a (p.26), X.c.9 (p. 33), and XI.d.5 (p.57). Mechanical equipment located at grade should be screened from view with a fence or wall that is constructed of the same materials as the adjacent building. Rooftop equipment that cannot be located out of view should be screened by walls constructed of materials sympathetic to those of the primary facade. VIII. Materials Building materials throughout the districts consist primarily of masonry and stucco. The existing buildings currently have a good palette of colors, textures and material mixes from which new materials should be selected. The masonry palette consists of wirecut, smooth and textured modular brick and rough-face and dressed limestone veneer. Rough-faced limestone should be limited to accent or base pieces only. The brick color palette should be restricted to those present in the district but can vary in color from reds to yellows and have varying levels of iron spotting. Pink or orange brick is not allowed. English Tudor buildings obtain some of their character from the mix of materials used in the upper floors. Creative use of material combinations is encouraged to break up the massing. The number of facade colors should be minimized to maintain unified districts – white and cream stucco with reds and browns, emphasizing earth tones and eliminating saturated colors. Commercial and Mixed Use: Acceptable materials include modular brick, rough-faced or dressed limestone and exterior grade stucco with wood trim. Wood, aluminum or vinyl siding, metals, rough/random lannon stone, concrete block (split face or smooth) and glassblock are not acceptable materials. EIFS may be allowed if the location is limited to the second floor facades or higher and the finish and articulation are acceptable. The finish of the EIFS must resemble exterior grade stucco of the historic English Tudor buildings in the Village. Institutional: Institutional buildings are encouraged to have monochromatic material selection such as modular brick, or rough-faced or dressed stone. Wood, aluminum or vinyl siding, metals, rough/random lannon stone, concrete block (split-face or smooth) and glassblock are not acceptable materials. EIFS may be allowed if the location is limited to the second floor facades or higher on secondary facades only and the finish and articulation are acceptable. The finish of the EIFS must resemble exterior grade stucco of the historic English Tudor buildings in the Village. Multiple-Family Residential: Acceptable material for multiple-family structures includes modular brick, limited areas of dressed limestone, and exterior grade stucco with wood trim. Wood siding is allowed on secondary facades on upper floors only. Aluminum or vinyl siding, metals, rough/ random lannon stone, concrete block (split face or smooth) and glassblock are not acceptable materials. EIFS may be allowed if the location is limited to the second floor facades or higher and the finish and articulation are acceptable. The finish of 23 Building & Architecture Page 201 of 207 Village of Winnetka, Illinois the EIFS must resemble exterior grade stucco of the historic English Tudor buildings in the Village. Acceptable Materials: a. Primary Facade Commercial, Mixed Use, Multiple-Family and Institutional Modular face brick (See figure 43) Limestone (Limited to partial first floor only. Limestone is to be integrated with brick for multiple- family residential) (See figure 44) Cast stone, which clearly simulates stone, is limited to accent pieces such as belt courses, sills and shoes. (Split face or rusticated are not permitted.) Exterior grade stucco with wood trim (See figure 45) Wood siding (Multi family Residential Figure 43 only) b. Secondary Facade Commercial, Mixed Use, Multiple-Family and Institutional Modular face brick (See figure 43) Modular common brick Dressed limestone (Limited to first floor only) (See figure 44) Cast stone, which clearly simulates stone, is limited to accent pieces such as belt courses, sills and shoes. (Split face or rusticated are not permitted.) Exterior grade Stucco with wood trim (See figure 45) Figure 44 EIFS (upper floors only, troweled texture to resemble stucco) (See figure 46) c. Roof materials Commercial, Mixed Use, Multiple-Family and Institutional. Clay Tiles (See figure 47) Cement Tiles and Shingles Ceramic Tiles that simulate natural materials. Figure 45 Design Guidelines 24 Page 202 of 207 Architectural Series of Asphalt Shingles (3 ply) (See figure 49) Wood Shingles (Fire treated) Slate (See figure 48) Real Copper (No other metal roofs are allowed) Figure 46 Institutional only Flat roofs must be hidden by parapet on primary / secondary facades. Commercial and Multiple- Family Flat roof must not be visible from street, pedestrian, or open spaces. d. Door and Window Materials: Commercial, Mixed Use, Institutional, Multiple- Family Residential: Entry doors should be wood or aluminum stile and rail with varying degrees of glass. Public entry doors should be Figure 47 fully glazed whereas private and semi- private entries should be primarily solid panel doors. Storefront window units should be either paneled aluminum or brass. Many original storefronts, some with transom windows, remain in the districts. Efforts should be taken to repair and renovate these systems Figure 48 where feasible. Window frames should be wood, steel or aluminum. Vinyl windows are not acceptable. Muntin divisions should be real divided glass or simulated with spacer bars. Snap-in muntins are not acceptable. Color selection should be sympathetic with the overall building color palette and take into account the adjacent building materials within the structure, immediately adjacent structures, structures within the same block and Figure 49 structures across the street. Entry door hardware is to be exterior grade with weather-resistant finish. Hardware design and finish is to be appropriate with facade articulation, color palette and district character. Glazing should be clear glass without tint or film. 25 Building & Architecture Page 203 of 207 Village of Winnetka, Illinois Garage doors should be designed to replicate stile and rail paneled doors if they are in view of the public or pedestrian way. The doors can be constructed of wood. Overhead rolling doors are allowed. IX. Service, Secondary Facades and Parking Structures a. Service Areas: Service areas allow for loading zones and dumpster placement. Commercial, Mixed Use, Institutional, and Multiple-Family Residential: Service areas are to be located off secondary streets or alleys out of public view. If a service area is visible from the public view, the service area is to be treated with screening approximately 6’-8’ tall to match adjacent building elevations. b. Secondary Facade(s): Fenestration of secondary facades should comply with Section VI.d. When a secondary public entrance is located off a parking area or alley, the alley is to be treated as an extension of the public walkway, and the building entrance is to be articulated to differentiate it from private or semi-private entrances. c. Parking Structures: As new developments occur within the business districts, multiple-family residential and institutional areas, parking structures may be incorporated into their designs in order to meet parking needs. Parking structures should be located remotely from primary streets and should not be visible from the public way. All parking structures should provide a safe and pleasant pedestrian entrance and exit from the structure. Parking structures servicing the commercial districts should integrate into the surrounding architectural fabric. Structures serving residential buildings should relate to the architectural fabric. Parking structures at a commercial development should be incorporated into the design of the development so that they blend into the building’s architecture, scale, and surrounding streetscape context. Integrated parking structures should provide a seamless and non-evident appearance of parking. Their scale and mass should be compatible with the standards set forth in these design guidelines. Building materials, details, and articulation should be consistent with that of the overall development and surrounding context when visible from the public way. Adequate vehicular and pedestrian access into the structure, ADA compatibility, safety, lighting, and ventilation issues must be addressed. Please see Vehicular Zone Landscape in Section XI.d for information on parking structure landscape requirements. 1. Massing: The parking structure should comply with the general commercial and mixed-use building massing guidelines (Section V) with the following exceptions. The parking structure should contribute to the continuous “streetwall” along the primary thoroughfares and respect the adjacent setbacks of existing buildings. Heights of the parking structure are delineated in this guideline under Parking Lot Standards. Freestanding residential parking structures should be adequately screened from view. 2. Proportions and Rhythms: Parking structures are to conform to the general commercial and mixed-use proportions and scale guidelines as outlined in Section VI. Design Guidelines 26 Page 204 of 207 The horizontal and vertical rhythms of the structure should enforce the rhythms established by the immediately adjacent and facing structures in order to unify the streetwall. Structures abutting a primary or secondary way should maintain a screen wall with a maximum of 20% openings and a maximum frontage at grade of 30 feet. Parking structures with street frontage that exceeds 30 feet should incorporate sales tax generating uses at the ground level so that the streetwall continues to offer the pedestrian shopping experience. The storefront at the sales tax generating use should comply with the General Commercial and Mixed-Use Guidelines. Off the primary and secondary streets, the parking structure expansion is limited by the current zoning ordinance. Parking structures serving residential units should also contain a screen wall and conform to the general multiple-family design guidelines. Freestanding parking structures should not exceed 14 feet in height above adjacent average grade or top of curb to the upper parking deck. 3. Articulation: The pedestrian entrance should be clearly articulated independent of the adjacent screen wall. The first floor screen wall should display the proportions and rhythms as indicated above while incorporating appropriate articulation. Shallow blind niches and recesses as well as expressed columns are encouraged to break down the screen wall and provide scale. Integral way-finding signs, street furniture, trash receptacles, newspaper corrals, drinking fountains and public art are encouraged as design elements at the screen wall. 4. Materials: The parking structure must be clad in the materials palette identified in Section VIII. Monochromatic or limited material combination is encouraged to downplay the hierarchy of the structure. Exposed concrete facades are not permitted, although cast stone accent and cladding materials units are acceptable. Parking structures serving residential units must apply creative material selection per the general multiple-family design guidelines. Material selection may be limited to less expensive material when not visible from the public way. Public Spaces/Streetscapes GENERAL GUIDELINES X. Pedestrian Zones and Pedestrian Circulation As part of Winnetka’s Business Districts, Multiple Family Residential and Institutional areas, the pedestrian-friendly character of the streetscape lends to the charm and ambience of these districts. Elements that are characteristic of a pedestrian-oriented street include narrow rights-of- way, numerous storefronts with display windows and a high volume of pedestrian traffic. Care should be taken to maintain and enhance these elements within Winnetka. Attention should be paid to all existing streetscape/pedestrian zones and to ensure that those created, altered and amended by future developments continue to enhance Winnetka’s pedestrian-friendly character. Special consideration must be given to enhancing and providing safe, efficient movement for these districts’ users. 27 Public Spaces/Streetscapes Page 205 of 207 Village of Winnetka, Illinois 1. Location/Orientation and Access for Parking Areas: New parking should be located behind, within or underneath structures and buildings. (See Figures 65a and 65b) Off-street surface parking lots in front of new buildings and along street frontages are prohibited. Access to all parking and loading areas must be provided off secondary streets or existing alleys/service drives. Access to underground parking facilities should also New surface parking opportunity located be provided from an alley or service drive. behind the building Figure 65a If appropriate and feasible, on street parking within the district should be provided within the public rights-of-way in front of new buildings. Curb cuts and vehicular entrances should be minimized throughout the business districts. Building owners are encouraged to share access points to their parking lots. Each curb cut location should be safe, efficient and approved by the Village Engineer. Access should be provided from mid- block alleys and secondary streets. Access should not be from main district streets unless deemed appropriate by the Village Engineer. These larger entrances should be defined with adequately designed and coordinated signs, landscaping or Defined and articulated alley gateway in character with architectural elements that complement the business district, leads to service and parking in rear design of the development and add visual Figure 65b interest to the street. (See Figure 65c and 65d) Design Guidelines 44 Page 206 of 207 Shared parking should be provided, where possible, between adjacent land uses and businesses, especially on blocks that have varied parking needs. (See Figure 66) For example, a business with daytime employee and shopper parking may allow evening use of the same lot by apartment dwellers, shoppers or restaurant patrons. Shared parking should be considered if a public/semi-public parking structure is anticipated as part of future development Clear and visible, in the districts. coordinated public signage element Figure 65d Mid-block alleyway with landscaping The Village Standard for parking stalls is 9’x18’ as established by and signage enhancements ITE (Institute of Traffic Engineers). A 9’x19’ stall is encouraged Figure 65c for all new parking areas. 2. Location/Orientation and Access for Loading Areas: All service areas should be located at the rear or side yard of new developments within the business districts. Access should be provided via mid-block alleys/driveways or from secondary streets. Exterior mechanical systems, loading/service, and trash storage areas should also be located out of sight from public roads. To the extent possible, these elements should be contained within the new building. If these elements are located outside the building envelope, all efforts should be made to visually screen and buffer them with permanent year-round screening from street and sidewalk views (See section XId5 for more information on screening). Service areas/trash storage areas should be clustered together between businesses wherever possible. 45 Public Spaces/Streetscapes Page 207 of 207
Design Review Board — Winnetka, IL