General
Regular MeetingWinnetka, IL · July 17, 2023
Minutes
1 ZONING ADMINISTRATOR
2 JULY 17, 2023, MEETING MINUTES
3
4 Village Staff: David Schoon, Director of Community Development
5 Ann Klaassen, Assistant Director of Community Development
6
7 Call to Order:
8 Mr. Schoon called the meeting to order at 4:00 p.m.
9
10 Public Comment:
11 No comments were made at this time.
12
13 New Applications:
14 a. Case No. 23-12-ZA - 789 Humboldt Avenue: An application seeking approval of a zoning
15 variation to allow replacement of an existing legally nonconforming portion of the existing residence at
16 789 Humboldt Avenue that would provide less than the minimum required rear yard setback from the
17 westerly property line. The Zoning Administrator has final jurisdiction on this request.
18 Mr. Schoon asked for the applicant’s presentation. Heidi Paul, the architect for the project, stated they
19 want to rebuild what is there since the current condition is not properly built with the addition having the
20 same volume. She stated in the property’s conforming location, they would be adding a small addition
21 and they would remain within the existing footprint with regard to the nonconforming portion of the
22 property.
23
24 Mr. Schoon noted for the record that there is no one from the public in attendance to comment on the
25 application and no correspondence was received. He stated that he reviewed the application materials
26 prior to the meeting and found that the request complied with the standards for granting such variation
27 and approved the request.
28
29 Adjournment:
30 The meeting adjourned at 4:02 p.m.
31
32 Respectfully submitted,
33
34 Antionette Johnson
35 Recording Secretary
Agenda
Village of Winnetka
Zoning Administrator Meeting
July 17, 2023 at 4:00 PM
Winnetka Village Hall Council Chambers
510 Green Bay Road
AGENDA
1. Call to Order & Roll Call
2. Public Comments
3. New Applications
a. Case No. 23-12-ZA - 789 Humboldt Avenue: An application seeking approval
of a zoning variation to allow replacement of an existing legally nonconforming
portion of the existing residence at 789 Humboldt Avenue that would provide
less than the minimum required rear yard setback from the westerly property
line. The Zoning Administrator has final jurisdiction on this request.
4. Adjournment
NOTICE
Public comment is permitted on all agenda items at the meeting. If you wish to provide testimony or comments
prior to the meeting, you may provide them one of two ways: (1) by sending an email to planning@winnetka.org; or
by sending a letter to Community Development, Village of Winnetka, 510 Green Bay Road, Winnetka, IL 60093. All
agenda materials are available at www.villageofwinnetka.org/agendacenter.
The Village of Winnetka, in compliance with the Americans with Disabilities Act, requests that persons with
disabilities, who require certain accommodations to allow them to observe and/or participate in this meeting or have
questions about the accessibility of the meeting or facilities contact the Village ADA Coordinator at 510 Green Bay
Road, Winnetka, Illinois 60093, (Telephone (847) 716-3543; T.D.D. (847) 501-6041).
Packet
Village of Winnetka
Zoning Administrator Meeting
July 17, 2023 at 4:00 PM
Winnetka Village Hall Council Chambers
510 Green Bay Road
AGENDA
1. Call to Order & Roll Call
2. Public Comments
3. New Applications
a. Case No. 23-12-ZA - 789 Humboldt Avenue: An application seeking approval
of a zoning variation to allow replacement of an existing legally nonconforming
portion of the existing residence at 789 Humboldt Avenue that would provide
less than the minimum required rear yard setback from the westerly property
line. The Zoning Administrator has final jurisdiction on this request.
4. Adjournment
NOTICE
Public comment is permitted on all agenda items at the meeting. If you wish to provide testimony or comments
prior to the meeting, you may provide them one of two ways: (1) by sending an email to planning@winnetka.org; or
by sending a letter to Community Development, Village of Winnetka, 510 Green Bay Road, Winnetka, IL 60093. All
agenda materials are available at www.villageofwinnetka.org/agendacenter.
The Village of Winnetka, in compliance with the Americans with Disabilities Act, requests that persons with
disabilities, who require certain accommodations to allow them to observe and/or participate in this meeting or have
questions about the accessibility of the meeting or facilities contact the Village ADA Coordinator at 510 Green Bay
Road, Winnetka, Illinois 60093, (Telephone (847) 716-3543; T.D.D. (847) 501-6041).
Page 1 of 16
NOTICE OF WINNETKA ZONING ADMINISTRATOR PUBLIC HEARING
Notice is hereby given that a public hearing will be held by the Winnetka Zoning Administrator on MONDAY,
JULY 17, 2023 AT 4:00 PM in the Council Chamber of the Winnetka Village Hall at 510 Green Bay Road,
Winnetka, Illinois for the purpose of considering the following:
CASE NO. 23-12-ZA
789 HUMBOLDT AVENUE – ALTERATONS TO RESIDENCE
An application submitted by Dan Greiwe and Phyllis Myers (collectively the “Applicant”), as the contract
purchaser of the property located at 789 Humboldt Avenue (the “Subject Property”), on behalf of the Valerie
P. Kennedy 1994 Trust, the current owner of the Subject Property, to allow replacement of an existing legally
nonconforming portion of the existing residence on the Subject Property. The Applicant has filed an
application seeking the following variation from the Zoning Ordinance:
1. A variation to provide less than the minimum required rear yard setback of 22.5 feet from the
westerly property line.
The Subject Property (Parcel Index Number 05-17-415-025-0000) is generally located on the southwest
corner of the intersection of Humboldt and Prospect Avenues and is zoned R-3 Single Family Residential. The
Subject Property contains an existing two-story residence with an attached garage.
PUBLIC COMMENT & APPLICATION INFORMATION
At said public hearing and at any adjournment thereof, all persons interested are invited to attend and be
heard. The agenda and materials for the meeting will be posted on the Village’s website -
www.villageofwinnetka.org/agendas no later than Thursday, July 13, 2023. Persons seeking additional
information concerning this application are directed to email inquiries to planning@winnetka.org or by
calling 847-716-3525.
If you wish to provide testimony or comments prior to the meeting, you may provide them one of two ways:
1) By sending an email to planning@winnetka.org; or
2) By sending a letter to Community Development, Village of Winnetka, 510 Green Bay Rd, Winnetka,
IL 60093.
The Village of Winnetka, in compliance with the Americans with Disabilities Act, requests that persons with
disabilities, who require certain accommodations to allow them to observe and/or participate in this meeting
or have questions about the accessibility of the meeting facilities, contact the Village ADA Coordinator at 510
Green Bay Road, Winnetka, Illinois 60093 [Telephone: (847) 716-3543; T.T.Y.: (847) 501-6041.
Page 2 of 16
Subject Property
Proposed Addition
in Compliance with
Zoning
Location of
Construction Requiring
Zoning Variation
Excerpt of Proposed Site Plan
(Note: Details may change through review process.)
Page 3 of 16
23-12-ZA
Page 4 of 16
06/19.2023
Dear Zoning Administrator,
789 Humboldt Ave is an irregular corner lot. The zoning code corner lot definition seems to address regular corner
lots where the shorter of the two frontages is typically the front yard. In this instance, the shorter of the two frontages
(40.10’) is diminutive in comparison to the much larger 185.69’ that faces Humboldt. The house faces Humboldt
Avenue, but the side of the house technically qualifies as the rear yard. Due to this categorization in the zoning code,
the existing house encroaches into the rear yard setback.
We are asking for zoning relief for two changes to the existing building;
1. The owner would like to add windows in the existing southeast elevation of the house
2. The owner would like to rebuild the existing square footage of the sunroom off the of the back (northwest corner
of the southwest elevation) which has currently fallen into disrepair.
In application of the Standards for Granting of Zoning Variations:
1. 789 Humboldt cannot yield a reasonable return if permitted to be used only under the current conditions allowed
by the regulations of the district. Ten feet of the existing structure encroaches into the rear yard setback, this
portion of the house has fallen into disrepair and requires restoration.
2. The 789 Humboldt lot is unique in shape. The siting of the original house encroaches on the rear yard setback.
To remove this portion of the house and rebuild it in the “buildable area” would create extreme hardship on the
owner and it would have an adverse effect on the architecture of the house and the neighborhood.
3. The variation, if grated, will not alter the essential character of the locality as the footprint of the encroached
portion of the house will remain exactly the same in footprint and in character.
4. The volume of the house does not change, therefore the impact of light and air on the adjacent homes remains
the same.
5. The volume of the house does not change, therefore the hazard for fire or other damages to the property will not
increase. In fact, given the materials and construction methods to be used, the hazard will decrease.
6. The revisions to the house will increase the taxable value of the land and buildings throughout the Village due to
the upgrades in materials and performance.
7. The congestion to the public street will not increase due to the footprint of the building not changing and the
function of the property shall remain the same.
8. The public health, safety, comfort, morals and welfare of the inhabitants of the Village will not be otherwise
impaired as the building footprint in the encroached area is not changing.
The existing structure includes a legal nonconformity in the rear yard setback. Our proposed improvement requires
formalizing of the nonconformity without increasing the square footage/degree of the non conformity. The proposed
improvement will enhance the utility and value of the property within the context of the established neighborhood and
there is no economically viable alternative that will cure the nonconformity. We are requesting a reduction of the rear
yard setback from 22.5” to 12.42” (44.8% reduction) to allow the existing building envelope to stay in its existing
location.
Thank you,
Heidi Paul
Architect for the Myers + Greiwe Family
Paul Studio Design
312.401.4025
Page 5 of 16
Page 6 of 16
CT
PE
OS
PR
UE
EN
AV
40
.1
0' ps
PAUL STUDIO DESIGN
845 WEST FULLERTON
/4" RD
CHICAGO, IL 60614
1 PAULSTUDIO@ME.COM
'-8 YA 312.401.4025
40 NT CK
O BA
FR SET
0 '
0 .0
15
EXISTING SECOND
FLOOR AREA: 971.74 SF
"
'-0 RD
12 YA K
DE AC EXISTING BLDG
SI ETB COVERAGE: 3,047.6 SF
S
6'-
3
1/
2" PROPOSED ADDITON
COVERAGE: 59.3 SF CORN 29
ER FR'-0"
16
"
'-6 ARD
'-2 " 4'-
7 O
N 2 SETB NT YARD
1/
2 Y K 2" 6"
3 SECOND FLOOR AREA DIAGRAM AR BAC ACK
7'-
scale: 3/32" = 1'-0" E
R ET
O
TI
8"
8'-
S NE
PA
O '-2 "
ST 12
IMPERMEABLE PATIO
AND WALKWAY
EXISTING TO BE REBUILT
COVERAGE: 886 SF
' -5" . 6'-8" FLOOR AREA: 120.7 SF
12 IST K
EX BAC IVE
T
SE K DR
ST BRIC
O
NE
W
AL
.69'
K
185
E
DRI
V ISSUED FOR: DATE:
BLE
PROPOSED ADDITON ST
O MEA DD REVIEW 06.23.23
FLOOR AREA: 59.3 SF NE PER
EXISTING FIRST W
AL N
K
FLOOR AREA: 3,047.6 SF AP
O
14 ET
E
R
UE
NC
0 R
VEN
6.7
CO
'
EXISTING TO BE REBUILT TA
FLOOR AREA: 120.7 SF
OLD PRIVATE
MB
RESIDENCE
789 HUMBOLDT AVE
HU WINNETKA, IL 60093
IVE
DR
ICK
BR
SITE
PLAN
FIRST FLOOR AREA DIAGRAM
2 scale: 3/32" = 1'-0"
N
SITE PLAN
1 scale: 3/32" = 1'-0"
N
A1.1
Page 7 of 16
LEGEND
EXISTING WALL TO REMAIN
EXISTING TO BE REMOVED
GENERAL DEMO NOTES
A. REMOVE ALL ITEMS INDICATED.
CONTRACTOR IS RESPONSIBLE FOR
SHORING OF EXISTING
CONSTRUCTION AS REQUIRED
DURING DEMOLITION AND
CONSTRUCTION.
B. PROTECT ALL EXISTING STRUCTURE
TO REMAIN FROM DAMAGE & DEBRIS
DURING DEMOLITION &
CONSTRUCTION
C. REMOVE INSULATION AND ANY
ELECTRICAL AND PLUMBING
3 3
SERVICES AS REQUIRED.
D. REMOVE ALL ABANDONED WATER,
WASTE, VENT, ELECTRIC AND GAS
LINES AS REQUIRED.
E. CAP ALL WATER, WASTE , GAS AND
ELECTRICAL SERVICES AS REQUIRED.
ps
PAUL STUDIO DESIGN
F. REMOVE ALL INTERIOR FINISHES. 845 WEST FULLERTON
CHICAGO, IL 60614
PAULSTUDIO@ME.COM
1 .401.40 5
DEMO NOTES
1. REMOVE PORTION OF EXISTING WALL
& PREPARE AREA FOR NEW OPENING
2. REMOVE EXISTING EXTERIOR WALL
AND WINDOWS/DOOR FOR ADDITION
3. REMOVE EXISTING WINDOW/DOOR &
3 PREPARE AREA AS REQUIRED FOR
NEW WINDOW/DOOR
4. REMOVE EXISTING INTERIOR
3 PARTITION & TRIM
5. REMOVE EXISTING STAIR
CONSTRUCTION
3 6. REMOVE EXISTING DOOR & CASING
GARAGE
7. REMOVE EXISTING CABINETRY &
3 3 --- COUNTERTOP
8. REMOVE EXISTING PLUMBING
FIXTURES
UP 9. REMOVE EXISTING APPLIANCES
10. REMOVE EXISTING SKYLIGHT & ROOF
11. REMOVE EXISTING DECK & ROOF
3
UP
3 3 3 3 3 3 6
4
3
DINING D W 8
3 3 3
---
3 9 9
3 7
3 4
3 1 1 LAUNDRY MUDROOM
--- ---
6 3
SUNROOM 4 4
---
ELEC
3
FURN. W.H. 4
UP 6 9
ENTRY
3 FOYER 3
3 4 6
--- 6
8
3 1
1 1 7 4 7
UP
3 LIVING
ROOM PANTRY 6
--- KITCHEN
--- 8
3
5 4
6 KITCHEN 8
7 ---
7 3
STUDY 6 6
--- 8 4
4
6
4 4 1
9
BATH
ISSUED FOR: DATE:
8 8 9
--- GUEST 4
BEDROOM
SD REVIEW 05.26.23
6 3
W/C --- ZONING REVIEW 06.19.23
4 6 ---
3 3 2 2
8 8
BREAKFAST
1 NOOK
2
---
3 1 3
LIBRARY 2 2
---
10 10
PRIVATE
3 RESIDENCE
10 3 789 HUMBOLDT AVE
WINNETKA, IL 60093
3
FIRST FLOOR
DEMOLITION
FIRST FLOOR DEMOLITION PLAN
PLAN
1 scale: 1/4" = 1'-0"
N
D2.1
Page 8 of 16
LEGEND
EXISTING WALL TO REMAIN
EXISTING TO BE REMOVED
GENERAL DEMO NOTES
A. REMOVE ALL ITEMS INDICATED.
CONTRACTOR IS RESPONSIBLE FOR
SHORING OF EXISTING
CONSTRUCTION AS REQUIRED
DURING DEMOLITION AND
CONSTRUCTION.
B. PROTECT ALL EXISTING STRUCTURE
TO REMAIN FROM DAMAGE & DEBRIS
DURING DEMOLITION &
CONSTRUCTION
C. REMOVE INSULATION AND ANY
ELECTRICAL AND PLUMBING
SERVICES AS REQUIRED.
D. REMOVE ALL ABANDONED WATER,
WASTE, VENT, ELECTRIC AND GAS
LINES AS REQUIRED.
E. CAP ALL WATER, WASTE , GAS AND
ELECTRICAL SERVICES AS REQUIRED.
ps
PAUL STUDIO DESIGN
F. REMOVE ALL INTERIOR FINISHES. 845 WEST FULLERTON
CHICAGO, IL 60614
PAULSTUDIO@ME.COM
1 .401.40 5
DEMO NOTES
1. REMOVE PORTION OF EXISTING WALL
& PREPARE AREA FOR NEW OPENING
2. REMOVE EXISTING EXTERIOR WALL
AND WINDOWS/DOOR FOR ADDITION
3. REMOVE EXISTING WINDOW/DOOR &
PREPARE AREA AS REQUIRED FOR
NEW WINDOW/DOOR
4. REMOVE EXISTING INTERIOR
PARTITION & TRIM
5. REMOVE EXISTING STAIR
CONSTRUCTION
6. REMOVE EXISTING DOOR & CASING
7. REMOVE EXISTING CABINETRY &
COUNTERTOP
3
8. REMOVE EXISTING PLUMBING
FIXTURES
9. REMOVE EXISTING APPLIANCES
10. REMOVE EXISTING SKYLIGHT & ROOF
11. REMOVE EXISTING DECK & ROOF
W.I.C.
---
4
6
4
PRIMARY
BEDROOM
3 ---
3
3
4
8
PRIMARY 6
BATH
---
8
4 4
6 6
8 6
4 4
4
4
6
4 4
3
STAIR 4
5 HALL BEDROOM
--- --- 3
6
8 3
8 8 6
BATH ISSUED FOR: DATE:
---
4
7 7 SD REVIEW 05.26.23
ZONING REVIEW 06.19.23
7
3
1 3 1
11
11
PRIVATE
10 10
RESIDENCE
789 HUMBOLDT AVE
WINNETKA, IL 60093
SECOND FLOOR
DEMOLITION
SECOND FLOOR DEMOLITION PLAN
PLAN
1 scale: 1/4" = 1'-0"
N
D2.2
Page 9 of 16
LEGEND
EXISTING WALL TO REMAIN
EXISTING TO BE REMOVED
GENERAL DEMO NOTES
A. REMOVE ALL ITEMS INDICATED.
CONTRACTOR IS RESPONSIBLE FOR
SHORING OF EXISTING
CONSTRUCTION AS REQUIRED
DURING DEMOLITION AND
CONSTRUCTION.
B. PROTECT ALL EXISTING STRUCTURE
TO REMAIN FROM DAMAGE & DEBRIS
13
DURING DEMOLITION &
CONSTRUCTION
12 C. REMOVE INSULATION AND ANY
ELECTRICAL AND PLUMBING
VIF
CENTER ON INTERIOR SPACE
SERVICES AS REQUIRED.
D. REMOVE ALL ABANDONED WATER,
WASTE, VENT, ELECTRIC AND GAS
LINES AS REQUIRED.
E. CAP ALL WATER, WASTE , GAS AND
ELECTRICAL SERVICES AS REQUIRED.
ps
PAUL STUDIO DESIGN
F. REMOVE ALL INTERIOR FINISHES. 845 WEST FULLERTON
CHICAGO, IL 60614
PAULSTUDIO@ME.COM
1 .401.40 5
3
DEMO NOTES
1 3 1
3
1. REMOVE PORTION OF EXISTING WALL
& PREPARE AREA FOR NEW OPENING
2. REMOVE EXISTING EXTERIOR WALL
AND WINDOWS/DOOR FOR ADDITION
10 10 3. REMOVE EXISTING WINDOW/DOOR &
T/EXIST. SECOND FLR PREPARE AREA AS REQUIRED FOR
11 +9'-3" (V.I.F.) NEW WINDOW/DOOR
11 4. REMOVE EXISTING INTERIOR
2 PARTITION & TRIM
5. REMOVE EXISTING STAIR
CONSTRUCTION
ALIGN HEADS 6. REMOVE EXISTING DOOR & CASING
3 7. REMOVE EXISTING CABINETRY &
3 3 3 2 COUNTERTOP
8. REMOVE EXISTING PLUMBING
3 1 3 7'-8" FIXTURES
EQUAL EQUAL 3 9. REMOVE EXISTING APPLIANCES
1
ALIGN SILLS 7'-0" VIF 10. REMOVE EXISTING SKYLIGHT & ROOF
MODIFY 11. REMOVE EXISTING DECK / ROOF
12. REMOVE EXISTING ROOF FOR NEW
EQUAL EQUAL
NEW DR T/EXIST. FIRST FLR
1 SKYLIGHT
0'-0" (V.I.F.)
13. REMOVE VENT AND STACK
8" GRADE
-1'-5" (V.I.F.)
NORTH DEMOLITION ELEVATION
2 scale: 1/4" = 1'-0"
12
ISSUED FOR: DATE:
SD REVIEW 05.26.23
ZONING REVIEW 06.19.23
3
3
T/EXIST. SECOND FLR
+9'-3" (V.I.F.)
PRIVATE
RESIDENCE
ALIGN ALIGN
789 HUMBOLDT AVE
3 3 3 3
3 3 3 3 3 3 WINNETKA, IL 60093
3 3 3
1'-0" 1'-0"
3 3
1 1
ALIGN ALIGN T/EXIST. FIRST FLR
0'-0" (V.I.F.)
GRADE
-1'-5" (V.I.F.)
DEMOLITION
EXTERIOR
ELEVATIONS
SOUTH DEMOLITION ELEVATION
1 scale: 1/4" = 1'-0"
D3.0
Page 10 of 16
LEGEND
EXISTING WALL TO REMAIN
EXISTING TO BE REMOVED
GENERAL DEMO NOTES
A. REMOVE ALL ITEMS INDICATED.
CONTRACTOR IS RESPONSIBLE FOR
SHORING OF EXISTING
CONSTRUCTION AS REQUIRED
DURING DEMOLITION AND
CONSTRUCTION.
B. PROTECT ALL EXISTING STRUCTURE
13 TO REMAIN FROM DAMAGE & DEBRIS
DURING DEMOLITION &
CONSTRUCTION
C. REMOVE INSULATION AND ANY
ELECTRICAL AND PLUMBING
SERVICES AS REQUIRED.
D. REMOVE ALL ABANDONED WATER,
WASTE, VENT, ELECTRIC AND GAS
LINES AS REQUIRED.
E. CAP ALL WATER, WASTE , GAS AND
ELECTRICAL SERVICES AS REQUIRED.
ps
PAUL STUDIO DESIGN
F. REMOVE ALL INTERIOR FINISHES. 845 WEST FULLERTON
CHICAGO, IL 60614
PAULSTUDIO@ME.COM
1 .401.40 5
DEMO NOTES
3 3 3 3
11 1. REMOVE PORTION OF EXISTING WALL
& PREPARE AREA FOR NEW OPENING
2. REMOVE EXISTING EXTERIOR WALL
AND WINDOWS/DOOR FOR ADDITION
3. REMOVE EXISTING WINDOW/DOOR &
T/EXIST. SECOND FLR PREPARE AREA AS REQUIRED FOR
+9'-3" (V.I.F.) NEW WINDOW/DOOR
10 4. REMOVE EXISTING INTERIOR
13 PARTITION & TRIM
5. REMOVE EXISTING STAIR
CONSTRUCTION
6. REMOVE EXISTING DOOR & CASING
1 3 3 7. REMOVE EXISTING CABINETRY &
2
3 COUNTERTOP
3
8. REMOVE EXISTING PLUMBING
3 FIXTURES
9. REMOVE EXISTING APPLIANCES
10. REMOVE EXISTING SKYLIGHT & ROOF
3'-0" 11. REMOVE EXISTING DECK / ROOF
12. REMOVE EXISTING ROOF FOR NEW
T/EXIST. FIRST FLR
SKYLIGHT
0'-0" (V.I.F.)
13. REMOVE VENT AND STACK
GRADE
-1'-5" (V.I.F.)
WEST DEMOLITION ELEVATION
2 scale: 1/4" = 1'-0"
13
ISSUED FOR: DATE:
SD REVIEW 05.26.23
ZONING REVIEW 06.19.23
3
10
T/EXIST. SECOND FLR
+9'-3" (V.I.F.)
PRIVATE
RESIDENCE
789 HUMBOLDT AVE
3
3 3 3
3 WINNETKA, IL 60093
3 3 3 3 3
T/EXIST. FIRST FLR
0'-0" (V.I.F.)
GRADE
-1'-5" (V.I.F.)
DEMOLITION
EXTERIOR
ELEVATIONS
EAST DEMOLITION ELEVATION
1 scale: 1/4" = 1'-0"
D3.1
Page 11 of 16
GENERAL NOTES
1. ALL WORK TO CONFORM TO THE VILLAGE OF
WINNETKA BUILDING AND ZONING CODE.
2. CONTRACTOR SHALL IMMEDIATELY INFORM THE
ARCHITECT OF DISCREPANCIES INDICATED ON THE
PERMITTED DOCUMENTS.
3. ALL NEW INTERIOR FINISHES TO MEET CLASS I FLAME
SPREAD RATING.
4. HARDWIRED SMOKE DETECTORS WITH BATTERY
BACKUP LOCATED IN ALL SLEEPING ROOMS &
OUTSIDE EACH SLEEPING AREA. MINIMUM ONE PER
FLOOR.
5. HARDWIRED CARBON MONOXIDE DETECTOR WITH
BATTERY BACKUP; MINIMUM ONE PER FLOOR.
WINDOW & DOOR NOTES
1. SAFETY GLAZING SHALL BE PROVIDED FOR ALL
SWINGING/SLIDING DOORS, WINDOWS ADJACENT TO
ps
DOORS, EXPOSED PANES GREATER THAN 9 SF,
BOTTOM EDGE LESS THAN 18" A.F.F. AND WITHIN 36"
OF A WALKING SURFACE.
2. ALL NEW INTERIOR DOORS TO BE SOLID CORE, 1 3/4"
THICK. ALL BEDROOMS TO HAVE 1 3/4" THICK SOLID
116.2 116.3 CORE DOORS WITH 1 3/4" RABETTED DOOR JAMBS
3. EMERGENCY ESCAPE OPENINGS SHALL HAVE MAX. PAUL STUDIO DESIGN
845 WEST FULLERTON
SILL HT. 44" A.F.F., CLEAR WIDTH 20" MIN., CLEAR HT. CHICAGO, IL 60614
24" MIN. AND CLEAR OPENING 5.7sf MIN. PAULSTUDIO@ME.COM
4. EXIT DOORS SHALL BE NOT LESS THAN 32" IN WIDTH 312.401.4025
5. ALL DOORS AND WINDOWS DIMENSIONED FROM THE
FACE OF THE WALL TO THE CENTERLINE OF THE DOOR
OR WINDOW. UNLESS NOTED OTHERWISE.
STAIR NOTES LEGEND
Stairways - IRC Section 311.7 and 312:
X WINDOW TAG
E · Width: Stairways shall be not less than 36 inches in clear width at all points above the permitted handrail height and below the
required headroom height. Handrails shall not project more than 4-1/2 inches on either side of the stairway and the clear width (SEE SCHEDULE)
of the stairway at and below the handrail height, including treads and landings, shall be not less than 31-1/2 inches where a
handrail is installed on one side and 27 inches where handrails are provided on both sides.
· Headroom: The headroom in stairways shall be not less than 6 feet 8 inches measured vertically from the sloped line adjoining
the tread nosing or from the floor surface of the landing or platform on that portion of the stairway. XXX.1 DOOR TAG
1 D ·
·
Vertical rise: A flight of stairs shall not have a vertical rise larger than 147 inches between floor levels or landings.
Stair treads and risers: The riser height shall be not more than 7-3/4 inches. Open risers are permitted provided that the
(SEE SCHEDULE)
openings do not permit the passage of a 4-inch-diameter sphere. The tread depth shall be not less than 10 inches.
A3.0 · Nosings: A nosing projection not less than 3/4 inch and not more than 1-1/4 inches shall be provided on stairways with solid
risers. Beveling of nosings shall not exceed 1/2 inch. 1 PLUMBING FIXTURE
C · Landings for stairways: There shall be a floor or landing at the top and bottom of each stairway. The width perpendicular to the
direction of travel shall be not less than the width of the flight served. Where the stairway has a straight run, the depth in the (SEE SCHEDULE)
GARAGE direction of travel shall be not less than 36 inches.
B1 · Stairway walking surface: The walking surface of treads and landings of stairways shall be sloped not steeper than one unit
B 116 vertical in 48 inches horizontal (2-percent slope).
· Handrails: Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more
risers. Handrail height, measured vertically from the sloped plane adjoining the tread nosing, shall be not less than 34 inches 4 A6.0 3 INTERIOR ELEVATION
8'-0" and not more than 38 inches. Handrails for stairways shall be continuous for the full length of the flight, from a point directly TAG
above the top riser of the flight to a point directly above the lowest riser of the flight. Handrail ends shall be returned or shall
terminate in newel posts or safety terminals. Handrails adjacent to a wall shall have a space of not less than 1-1/2 inches
between the wall and the handrails. 5
UP · Grip-size: Required handrails shall be of one of the following types or provide equivalent graspability. Type I. Handrails with a
circular cross section shall have an outside diameter of not less than 1-1/4 inches and not greater than 2 inches. If the handrail
is not circular, it shall have a perimeter dimension of not less than 4 inches and not greater than 6-1/4 inches with a cross CO CARBON DIOXIDE/
NEW STOOP (GRADE TO 1ST FLOOR): section dimension of not more than 2-1/4 inches. Edges shall have a radius of not less than 0.01 inch. Type II. Handrails with a SD SMOKE DETECTOR
perimeter greater than 6-1/4 inches shall have a graspable finger recess area on both sides of the profile. The finger recess shall
3 RISERS @ 6" A BEDROOM EGRESS
2'-8"
begin within a distance of 3/4 inch measured vertically from the tallest portion of the profile and achieve a depth of not less than
5/16 inch within 7/8 inch below the widest portion of the profile. The width of the handrail above the recess shall be not less than
2 TREADS @ 16" + 1" NOSING = 17" UNIT DIMENSIONS ARE 116.4 1-1/4 inchesand not more than 2-3/4 inches. Edges shall have a radius of not less than 0.01 inch. EXTERIOR FROST FREE
· Guards: Guards shall be located along open-sided walking surfaces, including stairs, ramps and landings, that are located
2R + 1T = 28" 3'-4" WIDE x 5'-8" HIGH 116.1 more than 30 inches measured vertically to the floor or grade below at any point within 36 inches horizontally to the edge of the HOSE BIB
UP EX
open side. Required guards shall be not less than 36 inches in height as measured vertically above the adjacent walking
STAIR WIDTH = 8'-0" CASEMENT WINDOW surface or the line connecting the leading edges of the treads. Guards on the open sides of stairs shall have a height not less
1'-4"
A than 34 inches measured vertically from a line connecting the leading edges of the treads. Where the top of the guard serves as
HANDRAIL @ 34" MIN. AFF a handrail on the open sides of stairs, the top of the guard shall be not less than 34 inches and not more than 38 inches as
±9'-0"
44" MAX SILL HEIGHT measured vertically from a line connecting the leading edges of the treads. Required guards shall not have openings from the
walking surface to the required guard height that allow passage of a sphere 4 inches in diameter. The triangular openings at the
P S S P open side of stair, formed by the riser, tread and bottom rail of a guard, shall not allow passage of a sphere 6 inches in diameter
BEDROOM
P
3'-8" W 3'-8" 112 3'-0" W.H.
P
D W ROOFING NOTES
V1 101.1 115.1
T V 1. CONTRACTOR TO PROVIDE FOR SEPARATION OF
±3'-3" ±9'-6" 1'-9" ±2'-8" 1'-9" 4'-0" ±7'-6"
U U DISSIMILAR METALS (SUCH AS BETWEEN ZINC AND
±3'-0"
ALUMINUM) WHEN REQUIRED TO PREVENT GALVANIC
R MUD ROOM LAUNDRY
112.2 ACTION.
114 115 F
2'-7" 115.2 2. ANY VENT OR STACK FROM AN APPLIANCE,
SUNROOM 2'-1" 2'-3" 1'-3" 2'-8"
MECHANICAL OR PLUMBING COMPONENT TO BE
103
5'-0" VENTED IN ACCORDANCE WITH ALL APPLICABLE
ENTRY ELEC 3'-0" CODES. ALL VENTS AND CAPS TO RISE ABOVE THE
EQ. UP FOYER FURN.
±2'-10"
113.1 BATH 113.2 ROOF WITH THE REQUIRED CLEARANCES AND TO BE
101 114.1 FLASHED.
113
G 3. VERIFY LOCATION OF ANY AND ALL ROOF OR WALL
Q EQ. EQ. 1'-7" PENETRATIONS WITH ARCHITECT PRIOR TO
INSTALLATION.
2'-0 1/2"
103.1 4. PROVIDE PRE-FINISHED METAL GUTTER AND
UP 112.1
P 103.2 ovens DOWNSPOUT SYSTEM (MATCH WINDOW CLAD COLOR)
ref/frz
PER DRAWINGS U.N.O. CONTRACTOR RESPONSIBLE
1'-8 1/2"
LIVING
ROOM EQ. FOR VERIFYING SIZE, QUANTITIES AND LOCATIONS OF
±7'-11"
1'-3"
GUTTERS, SCUPPERS, DOWNSPOUTS, ETC., AS
built-in 8'-0" built-in 102 4'-2" 101.2 3'-8" 3'-3" KITCHEN 2'-1"
H2 REQUIRED FOR A COMPLETE INSTALLATION.
3'-8" ±4'-2" 3'-3" 111.1 111
EQ. COORDINATE WITH LOCATIONS INDICATED IN
DRAWINGS AND REVIEW ANY CHANGES/ADDITIONS
WITH ARCHITECT PRIOR TO INSTALLATION. ALL
3'-7" DOWNSPOUTS TO DRAIN TO UNDERGROUND STORM
WATER COLLECTION SYSTEM PER CIVIL DRAWINGS,
3'-8" H1 UNLESS NOTED OTHERWISE. COORDINATE DETAILS
104.1 6'-0" ±13'-1 1/2" WITH CIVIL AND LANDSCAPE DESIGN TO ENSURE
ALIGNMENT OF DOWNSPOUTS WITH BELL
V.I.F.
CONNECTION LOCATIONS TO UNDERGROUND SYSTEM
EQ.
ice 3'-7" - NO OFFSETS WILL BE ACCEPTED.
H 5. PROVIDE CONTINUOUS WATERPROOF UNDERLAYMENT
2'-0 1/2" 5'-0" 5'-0" 3'-3" 2'-0 1/2" ("ICE & WATER SHIELD" BY W.R. GRACE OR APPROVED
STUDY 1'-6" POWDER RM 2'-6" EQUAL) AT ALL ROOF VALLEYS, HIPS, EAVES, RAKES,
102.1
104 109 3'-3" LOW SLOPE AND FLAT ROOFS AND CHANGES IN ROOF ISSUED FOR: DATE:
3'-10 1/2"
PITCH.
2
1'-9" EQ. 12'-0" EQ.
109.1
110.1 6. AT EAVES, WATERPROOF UNDERLAYMENT TO EXTEND DD REVIEW 06.23.23
A3.1
3'-0"
±3"
1 2'-0" 24" (MIN.) HORIZONTALLY INTO HEATED SPACE WHEN
±1'-9"
A3.1 ROOF PITCH IS 4:12 OR GREATER. EXTEND
105.1
N BATH WATERPROOF UNDERLAYMENT 36" (MIN.)
1'-0" 1'-0"
±8'-1"
105 HORIZONTALLY INTO HEATED SPACE WHEN ROOF
J
±2'-7"
EQ. ±8'-7" EQ. ±14'-4" ±6'-11" 1'-9" 3'-6" 5'-0" EQ. 12'-0" EQ. 3'-4" PITCH IS LESS THAN 4:12.
7. INSTALL WATERPROOF UNDERLAYMENT AT EAVES PER
1'-2" 7" 3'-0" UP MANUFACTURER'S STANDARD INSTALLATION DETAILS
VESTIBULE
5'-6" 6'-8" FOR "HIGH SNOW AREAS".
108
BREAKFAST
N1 N F
DINING 110 3'-4"
ALCOVE
3'-9" 9'-8" 3'-8"
ROOM
107
M 106
106.1
2'-10" 4'-7"
J
4'-5" 3" 5'-0 1/2"
K
9'-3"
K
5'-0 1/2"
PRIVATE
3'-0"
9'-0" 19'-4"
RESIDENCE
±8'-1"
F
±7'-1"
1'-0" 1'-0"
789 HUMBOLDT AVE
V.I.F. ±5'-7"
V.I.F. WINNETKA, IL 60093
2'-0"
2
L A3.0
±8'-0" 15'-4"
V.I.F. V.I.F.
±23'-4"
V.I.F. PROPOSED
FIRST FLOOR
PROPOSED FIRST FLOOR PLAN
PLAN
1 scale: 1/4" = 1'-0"
N
A2.1
Page 12 of 16
GENERAL NOTES
1. ALL WORK TO CONFORM TO THE VILLAGE OF
WINNETKA BUILDING AND ZONING CODE.
2. CONTRACTOR SHALL IMMEDIATELY INFORM THE
ARCHITECT OF DISCREPANCIES INDICATED ON THE
PERMITTED DOCUMENTS.
3. ALL NEW INTERIOR FINISHES TO MEET CLASS I FLAME
SPREAD RATING.
4. HARDWIRED SMOKE DETECTORS WITH BATTERY
BACKUP LOCATED IN ALL SLEEPING ROOMS &
OUTSIDE EACH SLEEPING AREA. MINIMUM ONE PER
FLOOR.
5. HARDWIRED CARBON MONOXIDE DETECTOR WITH
BATTERY BACKUP; MINIMUM ONE PER FLOOR.
WINDOW & DOOR NOTES
1. SAFETY GLAZING SHALL BE PROVIDED FOR ALL
SWINGING/SLIDING DOORS, WINDOWS ADJACENT TO
ps
DOORS, EXPOSED PANES GREATER THAN 9 SF,
BOTTOM EDGE LESS THAN 18" A.F.F. AND WITHIN 36"
OF A WALKING SURFACE.
2. ALL NEW INTERIOR DOORS TO BE SOLID CORE, 1 3/4"
THICK. ALL BEDROOMS TO HAVE 1 3/4" THICK SOLID
CORE DOORS WITH 1 3/4" RABETTED DOOR JAMBS
3. EMERGENCY ESCAPE OPENINGS SHALL HAVE MAX. PAUL STUDIO DESIGN
845 WEST FULLERTON
SILL HT. 44" A.F.F., CLEAR WIDTH 20" MIN., CLEAR HT. CHICAGO, IL 60614
24" MIN. AND CLEAR OPENING 5.7sf MIN. PAULSTUDIO@ME.COM
4. EXIT DOORS SHALL BE NOT LESS THAN 32" IN WIDTH 312.401.4025
5. ALL DOORS AND WINDOWS DIMENSIONED FROM THE
FACE OF THE WALL TO THE CENTERLINE OF THE DOOR
OR WINDOW. UNLESS NOTED OTHERWISE.
STAIR NOTES LEGEND
Stairways - IRC Section 311.7 and 312:
X WINDOW TAG
· Width: Stairways shall be not less than 36 inches in clear width at all points above the permitted handrail height and below the
required headroom height. Handrails shall not project more than 4-1/2 inches on either side of the stairway and the clear width (SEE SCHEDULE)
of the stairway at and below the handrail height, including treads and landings, shall be not less than 31-1/2 inches where a
handrail is installed on one side and 27 inches where handrails are provided on both sides.
· Headroom: The headroom in stairways shall be not less than 6 feet 8 inches measured vertically from the sloped line adjoining
the tread nosing or from the floor surface of the landing or platform on that portion of the stairway. XXX.1 DOOR TAG
1
·
·
Vertical rise: A flight of stairs shall not have a vertical rise larger than 147 inches between floor levels or landings.
Stair treads and risers: The riser height shall be not more than 7-3/4 inches. Open risers are permitted provided that the
(SEE SCHEDULE)
openings do not permit the passage of a 4-inch-diameter sphere. The tread depth shall be not less than 10 inches.
A3.0 · Nosings: A nosing projection not less than 3/4 inch and not more than 1-1/4 inches shall be provided on stairways with solid
risers. Beveling of nosings shall not exceed 1/2 inch. 1 PLUMBING FIXTURE
· Landings for stairways: There shall be a floor or landing at the top and bottom of each stairway. The width perpendicular to the
direction of travel shall be not less than the width of the flight served. Where the stairway has a straight run, the depth in the (SEE SCHEDULE)
direction of travel shall be not less than 36 inches.
· Stairway walking surface: The walking surface of treads and landings of stairways shall be sloped not steeper than one unit
vertical in 48 inches horizontal (2-percent slope).
Z · Handrails: Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more
risers. Handrail height, measured vertically from the sloped plane adjoining the tread nosing, shall be not less than 34 inches 4 A6.0 3 INTERIOR ELEVATION
and not more than 38 inches. Handrails for stairways shall be continuous for the full length of the flight, from a point directly
above the top riser of the flight to a point directly above the lowest riser of the flight. Handrail ends shall be returned or shall
TAG
terminate in newel posts or safety terminals. Handrails adjacent to a wall shall have a space of not less than 1-1/2 inches
between the wall and the handrails. 5
· Grip-size: Required handrails shall be of one of the following types or provide equivalent graspability. Type I. Handrails with a
circular cross section shall have an outside diameter of not less than 1-1/4 inches and not greater than 2 inches. If the handrail
is not circular, it shall have a perimeter dimension of not less than 4 inches and not greater than 6-1/4 inches with a cross CO CARBON DIOXIDE/
section dimension of not more than 2-1/4 inches. Edges shall have a radius of not less than 0.01 inch. Type II. Handrails with a SD SMOKE DETECTOR
perimeter greater than 6-1/4 inches shall have a graspable finger recess area on both sides of the profile. The finger recess shall
W.I.C. begin within a distance of 3/4 inch measured vertically from the tallest portion of the profile and achieve a depth of not less than
±5'-7"
5/16 inch within 7/8 inch below the widest portion of the profile. The width of the handrail above the recess shall be not less than
205 ·
1-1/4 inchesand not more than 2-3/4 inches. Edges shall have a radius of not less than 0.01 inch.
Guards: Guards shall be located along open-sided walking surfaces, including stairs, ramps and landings, that are located
EXTERIOR FROST FREE
more than 30 inches measured vertically to the floor or grade below at any point within 36 inches horizontally to the edge of the
open side. Required guards shall be not less than 36 inches in height as measured vertically above the adjacent walking
HOSE BIB
surface or the line connecting the leading edges of the treads. Guards on the open sides of stairs shall have a height not less
than 34 inches measured vertically from a line connecting the leading edges of the treads. Where the top of the guard serves as
a handrail on the open sides of stairs, the top of the guard shall be not less than 34 inches and not more than 38 inches as
measured vertically from a line connecting the leading edges of the treads. Required guards shall not have openings from the
205.1 walking surface to the required guard height that allow passage of a sphere 4 inches in diameter. The triangular openings at the
open side of stair, formed by the riser, tread and bottom rail of a guard, shall not allow passage of a sphere 6 inches in diameter
3'-4" 3'-4" ±17'-7"
ROOFING NOTES
4'-0"
X 1. CONTRACTOR TO PROVIDE FOR SEPARATION OF
204.2
Y X DISSIMILAR METALS (SUCH AS BETWEEN ZINC AND
PRIMARY ALUMINUM) WHEN REQUIRED TO PREVENT GALVANIC
6" BEDROOM ACTION.
206.1
204 X BEDROOM EGRESS 2. ANY VENT OR STACK FROM AN APPLIANCE,
UNIT DIMENSIONS ARE MECHANICAL OR PLUMBING COMPONENT TO BE
3'-0" 3'-0" WIDE x 4'-4" HIGH VENTED IN ACCORDANCE WITH ALL APPLICABLE
CASEMENT WINDOW CODES. ALL VENTS AND CAPS TO RISE ABOVE THE
PRIMARY
BATH ROOF WITH THE REQUIRED CLEARANCES AND TO BE
44" MAX SILL HEIGHT
±8'-7"
204.1 FLASHED.
206.3 206.2 206
3. VERIFY LOCATION OF ANY AND ALL ROOF OR WALL
STAIR (1ST FLOOR TO 2ND FLOOR): PENETRATIONS WITH ARCHITECT PRIOR TO
±5'-1"
15 RISERS @ 7.40" INSTALLATION.
4'-8"
3'-6"
14 TREADS @ 10" + 1" NOSING = 11" 4. PROVIDE PRE-FINISHED METAL GUTTER AND
2R + 1T = 24.8" 4'-6" 2'-10" 6'-8" 202.2 202.3 DOWNSPOUT SYSTEM (MATCH WINDOW CLAD COLOR)
STAIR WIDTH = 3'-8"; MIN. HEADROOM = 6'-8" PER DRAWINGS U.N.O. CONTRACTOR RESPONSIBLE
HANDRAIL @ 34" MIN. AFF 202.1 FOR VERIFYING SIZE, QUANTITIES AND LOCATIONS OF
GUTTERS, SCUPPERS, DOWNSPOUTS, ETC., AS
EQ. 6'-0" EQ. REQUIRED FOR A COMPLETE INSTALLATION.
±2'-5" EQ. ±3'-1"
COORDINATE WITH LOCATIONS INDICATED IN
STAIR DRAWINGS AND REVIEW ANY CHANGES/ADDITIONS
HALL 201.1 AA
SKYLIGHT WITH ARCHITECT PRIOR TO INSTALLATION. ALL
201 DOWNSPOUTS TO DRAIN TO UNDERGROUND STORM
ABOVE
WATER COLLECTION SYSTEM PER CIVIL DRAWINGS,
3'-8" DN
EQ. UNLESS NOTED OTHERWISE. COORDINATE DETAILS
3'-8" 5'-10" ±5'-2" WITH CIVIL AND LANDSCAPE DESIGN TO ENSURE
BB ALIGNMENT OF DOWNSPOUTS WITH BELL
SITTING
±7'-2"
CONNECTION LOCATIONS TO UNDERGROUND SYSTEM
202 - NO OFFSETS WILL BE ACCEPTED.
EQ. EQ. 5. PROVIDE CONTINUOUS WATERPROOF UNDERLAYMENT
3'-0" 1'-6" 3'-6" ±4'-1" AA
("ICE & WATER SHIELD" BY W.R. GRACE OR APPROVED
EQUAL) AT ALL ROOF VALLEYS, HIPS, EAVES, RAKES,
BATH 203.1 202.4 LOW SLOPE AND FLAT ROOFS AND CHANGES IN ROOF ISSUED FOR: DATE:
203 PITCH.
2 6. AT EAVES, WATERPROOF UNDERLAYMENT TO EXTEND DD REVIEW 06.23.23
±2'-11"
A3.1 24" (MIN.) HORIZONTALLY INTO HEATED SPACE WHEN
1
A3.1 ROOF PITCH IS 4:12 OR GREATER. EXTEND
WATERPROOF UNDERLAYMENT 36" (MIN.)
DD HORIZONTALLY INTO HEATED SPACE WHEN ROOF
PITCH IS LESS THAN 4:12.
CC
7. INSTALL WATERPROOF UNDERLAYMENT AT EAVES PER
MANUFACTURER'S STANDARD INSTALLATION DETAILS
FOR "HIGH SNOW AREAS".
PRIVATE
RESIDENCE
789 HUMBOLDT AVE
WINNETKA, IL 60093
2
A3.0
PROPOSED
SECOND FLOOR
PROPOSED SECOND FLOOR PLAN
PLAN
1 scale: 1/4" = 1'-0"
N
A2.2
Page 13 of 16
GENERAL NOTES
1. ALL WORK TO CONFORM TO THE VILLAGE OF
WINNETKA BUILDING AND ZONING CODE.
2. CONTRACTOR SHALL IMMEDIATELY INFORM THE
ARCHITECT OF DISCREPANCIES INDICATED ON THE
PERMITTED DOCUMENTS.
3. ALL NEW INTERIOR FINISHES TO MEET CLASS I FLAME
SPREAD RATING.
4. HARDWIRED SMOKE DETECTORS WITH BATTERY
BACKUP LOCATED IN ALL SLEEPING ROOMS &
OUTSIDE EACH SLEEPING AREA. MINIMUM ONE PER
FLOOR.
5. HARDWIRED CARBON MONOXIDE DETECTOR WITH
BATTERY BACKUP; MINIMUM ONE PER FLOOR.
WINDOW & DOOR NOTES
1. SAFETY GLAZING SHALL BE PROVIDED FOR ALL
SWINGING/SLIDING DOORS, WINDOWS ADJACENT TO
ps
DOORS, EXPOSED PANES GREATER THAN 9 SF,
BOTTOM EDGE LESS THAN 18" A.F.F. AND WITHIN 36"
OF A WALKING SURFACE.
2. ALL NEW INTERIOR DOORS TO BE SOLID CORE, 1 3/4"
THICK. ALL BEDROOMS TO HAVE 1 3/4" THICK SOLID
CORE DOORS WITH 1 3/4" RABETTED DOOR JAMBS
3. EMERGENCY ESCAPE OPENINGS SHALL HAVE MAX. PAUL STUDIO DESIGN
845 WEST FULLERTON
SILL HT. 44" A.F.F., CLEAR WIDTH 20" MIN., CLEAR HT. CHICAGO, IL 60614
24" MIN. AND CLEAR OPENING 5.7sf MIN. PAULSTUDIO@ME.COM
4. EXIT DOORS SHALL BE NOT LESS THAN 32" IN WIDTH 312.401.4025
5. ALL DOORS AND WINDOWS DIMENSIONED FROM THE
FACE OF THE WALL TO THE CENTERLINE OF THE DOOR
OR WINDOW. UNLESS NOTED OTHERWISE.
SLOPE SLOPE
EXIST RIDGE EXIST
STAIR NOTES LEGEND
LINE
Stairways - IRC Section 311.7 and 312:
X WINDOW TAG
· Width: Stairways shall be not less than 36 inches in clear width at all points above the permitted handrail height and below the
required headroom height. Handrails shall not project more than 4-1/2 inches on either side of the stairway and the clear width (SEE SCHEDULE)
of the stairway at and below the handrail height, including treads and landings, shall be not less than 31-1/2 inches where a
handrail is installed on one side and 27 inches where handrails are provided on both sides.
· Headroom: The headroom in stairways shall be not less than 6 feet 8 inches measured vertically from the sloped line adjoining
the tread nosing or from the floor surface of the landing or platform on that portion of the stairway. XXX.1 DOOR TAG
1
·
·
Vertical rise: A flight of stairs shall not have a vertical rise larger than 147 inches between floor levels or landings.
Stair treads and risers: The riser height shall be not more than 7-3/4 inches. Open risers are permitted provided that the
(SEE SCHEDULE)
A3.0 EXIST CEDAR SHAKE ·
openings do not permit the passage of a 4-inch-diameter sphere. The tread depth shall be not less than 10 inches.
Nosings: A nosing projection not less than 3/4 inch and not more than 1-1/4 inches shall be provided on stairways with solid
ROOFING - PATCH AS risers. Beveling of nosings shall not exceed 1/2 inch. 1 PLUMBING FIXTURE
· Landings for stairways: There shall be a floor or landing at the top and bottom of each stairway. The width perpendicular to the
REQ'D direction of travel shall be not less than the width of the flight served. Where the stairway has a straight run, the depth in the (SEE SCHEDULE)
direction of travel shall be not less than 36 inches.
· Stairway walking surface: The walking surface of treads and landings of stairways shall be sloped not steeper than one unit
vertical in 48 inches horizontal (2-percent slope).
· Handrails: Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more
risers. Handrail height, measured vertically from the sloped plane adjoining the tread nosing, shall be not less than 34 inches 4 A6.0 3 INTERIOR ELEVATION
and not more than 38 inches. Handrails for stairways shall be continuous for the full length of the flight, from a point directly
above the top riser of the flight to a point directly above the lowest riser of the flight. Handrail ends shall be returned or shall
TAG
terminate in newel posts or safety terminals. Handrails adjacent to a wall shall have a space of not less than 1-1/2 inches
between the wall and the handrails. 5
· Grip-size: Required handrails shall be of one of the following types or provide equivalent graspability. Type I. Handrails with a
circular cross section shall have an outside diameter of not less than 1-1/4 inches and not greater than 2 inches. If the handrail
is not circular, it shall have a perimeter dimension of not less than 4 inches and not greater than 6-1/4 inches with a cross CO CARBON DIOXIDE/
section dimension of not more than 2-1/4 inches. Edges shall have a radius of not less than 0.01 inch. Type II. Handrails with a SD SMOKE DETECTOR
perimeter greater than 6-1/4 inches shall have a graspable finger recess area on both sides of the profile. The finger recess shall
begin within a distance of 3/4 inch measured vertically from the tallest portion of the profile and achieve a depth of not less than
EXIST. PREFINISHED 5/16 inch within 7/8 inch below the widest portion of the profile. The width of the handrail above the recess shall be not less than
EXTERIOR FROST FREE
SLOPE
1-1/4 inchesand not more than 2-3/4 inches. Edges shall have a radius of not less than 0.01 inch.
METAL GUTTER SLOPE SLOPE · Guards: Guards shall be located along open-sided walking surfaces, including stairs, ramps and landings, that are located
EXIST EXIST
more than 30 inches measured vertically to the floor or grade below at any point within 36 inches horizontally to the edge of the HOSE BIB
EXIST
open side. Required guards shall be not less than 36 inches in height as measured vertically above the adjacent walking
surface or the line connecting the leading edges of the treads. Guards on the open sides of stairs shall have a height not less
than 34 inches measured vertically from a line connecting the leading edges of the treads. Where the top of the guard serves as
a handrail on the open sides of stairs, the top of the guard shall be not less than 34 inches and not more than 38 inches as
measured vertically from a line connecting the leading edges of the treads. Required guards shall not have openings from the
walking surface to the required guard height that allow passage of a sphere 4 inches in diameter. The triangular openings at the
open side of stair, formed by the riser, tread and bottom rail of a guard, shall not allow passage of a sphere 6 inches in diameter
RIDGE
EXIST. PREFINISHED
METAL GUTTER
EXIST CEDAR SHAKE
ROOFING - PATCH AS
LINE ROOFING NOTES
REQ'D 1. CONTRACTOR TO PROVIDE FOR SEPARATION OF
DISSIMILAR METALS (SUCH AS BETWEEN ZINC AND
ALUMINUM) WHEN REQUIRED TO PREVENT GALVANIC
ACTION.
SLOPE 2. ANY VENT OR STACK FROM AN APPLIANCE,
MECHANICAL OR PLUMBING COMPONENT TO BE
EXIST
RIDGE VENTED IN ACCORDANCE WITH ALL APPLICABLE
CODES. ALL VENTS AND CAPS TO RISE ABOVE THE
LINE ROOF WITH THE REQUIRED CLEARANCES AND TO BE
FLASHED.
3. VERIFY LOCATION OF ANY AND ALL ROOF OR WALL
SLOPE PENETRATIONS WITH ARCHITECT PRIOR TO
EXIST INSTALLATION.
4. PROVIDE PRE-FINISHED METAL GUTTER AND
EXIST. CHIMNEY CAP AND DOWNSPOUT SYSTEM (MATCH WINDOW CLAD COLOR)
FLUE TERMINATION PER DRAWINGS U.N.O. CONTRACTOR RESPONSIBLE
EXIST CEDAR SHAKE
SLOPE FOR VERIFYING SIZE, QUANTITIES AND LOCATIONS OF
ROOFING - PATCH AS
GUTTERS, SCUPPERS, DOWNSPOUTS, ETC., AS
REQ'D RIDGE EXIST REQUIRED FOR A COMPLETE INSTALLATION.
LINE COORDINATE WITH LOCATIONS INDICATED IN
EXIST. CHIMNEY CAP AND DRAWINGS AND REVIEW ANY CHANGES/ADDITIONS
FLUE TERMINATION WITH ARCHITECT PRIOR TO INSTALLATION. ALL
skylight DOWNSPOUTS TO DRAIN TO UNDERGROUND STORM
WATER COLLECTION SYSTEM PER CIVIL DRAWINGS,
SLOPE UNLESS NOTED OTHERWISE. COORDINATE DETAILS
RIDGE WITH CIVIL AND LANDSCAPE DESIGN TO ENSURE
EXIST LINE EXIST CEDAR SHAKE ALIGNMENT OF DOWNSPOUTS WITH BELL
ROOFING - PATCH AS CONNECTION LOCATIONS TO UNDERGROUND SYSTEM
REQ'D - NO OFFSETS WILL BE ACCEPTED.
EXIST. CHIMNEY CAP AND 5. PROVIDE CONTINUOUS WATERPROOF UNDERLAYMENT
SLOPE
SLOPE
FLUE TERMINATION RIDGE ("ICE & WATER SHIELD" BY W.R. GRACE OR APPROVED
EXIST EXIST. PREFINISHED EQUAL) AT ALL ROOF VALLEYS, HIPS, EAVES, RAKES,
LINE
METAL GUTTER LOW SLOPE AND FLAT ROOFS AND CHANGES IN ROOF ISSUED FOR: DATE:
PITCH.
SLOPE SLOPE 2 6. AT EAVES, WATERPROOF UNDERLAYMENT TO EXTEND DD REVIEW 06.23.23
EXIST EXIST A3.1
1 24" (MIN.) HORIZONTALLY INTO HEATED SPACE WHEN
A3.1 ROOF PITCH IS 4:12 OR GREATER. EXTEND
WATERPROOF UNDERLAYMENT 36" (MIN.)
HORIZONTALLY INTO HEATED SPACE WHEN ROOF
RIDGE PITCH IS LESS THAN 4:12.
LINE 7. INSTALL WATERPROOF UNDERLAYMENT AT EAVES PER
NEW CEDAR SHAKE MANUFACTURER'S STANDARD INSTALLATION DETAILS
SLOPE 1/4"
ROOFING TO MATCH FOR "HIGH SNOW AREAS".
SLOPE SLOPE PER FT.
EXISTING LOW-SLOPE BITUMINOUS
6.5:12 6.5:12
ROOFING MEMBRANE UNDER
COMPOSITE DECKING
EXIST. PREFINISHED
METAL GUTTER NEW CEDAR SHAKE
ROOFING TO MATCH
EXISTING
PRIVATE
RESIDENCE
PREFINISHED METAL
PREFINISHED METAL
GUTTER, MATCH EXIST. 789 HUMBOLDT AVE
GUTTER, MATCH EXIST. WINNETKA, IL 60093
SLOPE
SLOPE
6.5:12
2
A3.0
PROPOSED
ROOF
PROPOSED ROOF PLAN
PLAN
1 scale: 1/4" = 1'-0"
N
A2.3
Page 14 of 16
NEW CEDAR SHAKE
ROOFING TO MATCH EXIST CEDAR SHAKE
EXISTING ROOFING - PATCH AS
REQ'D
NEW WOOD SIDING -
FINISH TO MATCH
EXISTING HOUSE
NEW EAVE TRIM TO
MATCH EXISTING DETAIL
EXIST WOOD SIDING
AND TRIM - PRIME
FOR NEW PAINT
FINISH
ps
PAUL STUDIO DESIGN
845 WEST FULLERTON
CHICAGO, IL 60614
PAULSTUDIO@ME.COM
EXIST CEDAR SHAKE 1 .401.40 5
12 12 NEW METAL RAILING
ROOF - PATCH AS REQ'D
6.5 6.5 PAINTED FINISH
DD
CC
12 12 EXIST WOOD SIDING
EXIST WOOD TRIM - AND TRIM - PRIME
6.5 6.5
PRIME FOR NEW PAINT FOR NEW PAINT
FINISH FINISH
T/EXIST. SECOND FLR
+9'-3" (V.I.F.)
EXIST MASONRY
TUCKPOINT AS REQ'D
EXIST WOOD TRIM
F PRIME FOR NEW
N1 N PAINT FINISH
L
G
J K K
T/EXIST. FIRST FLR
0'-0" (V.I.F.)
GRADE
-1'-5" (V.I.F.)
NEW M.O. WITH ALUM CLAD NEW M.O. WITH ALUM CLAD EXISTING BRICK WITH
WINDOW UNIT AND LIMESTONE WINDOW UNITS AND LIMESTONE TOOTHED IN BRICK INFILL NEW MASONRY EXIST MASONRY
SILL TO MATCH EXISTING SILL TO MATCH EXISTING WITH NEW M.O. AND TUCKPOINT AS REQ'D
EXIST CONSTRUCTION NEW CONSTRUCTION NEW CONSTRUCTION LIMESTONE SILL TO NEW CONSTRUCTION
NEW CONSTRCUTION EXIST CONSTRCUTION
OVER EXISTING OVER EXISTING MATCH EXISTING NEW WOOD SIDING/TRIM -
FOUNDATION FOUNDATION PRIME FOR NEW PAINT
FINISH TO MATCH EXISTING
NORTH ELEVATION
2 scale: 1/4" = 1'-0"
TYPICAL NOTE: EXIST GENERAL NOTES:
MASONRY CHIMNEYS (3) 1. REPLACE ALL WINDOWS - VIF OPENINGS - SIZE TO FIT (BRICKMOLD IN M.O. )
- TUCKPOINT AS REQ'D 2. REPAIR EXISTING SHAKE ROOF
3. REPAIR (OR REPLACE IN KIND) EXISTING METAL ROOF AT FRONT BAY
NEW SKYLIGHT 4. REPAIR OR REPLACE IN KIND EXISTING SIDING AND TRIM - PREPARE WITH PRIME
FOR NEW PAINT FINISH
5. REPAIR AND TUCKPOINT EXISTING BRICK
TYPICAL NOTE: EXIST
6. AREAS OF NEW BRICK TO MATCH EXISTING - DO NOT USE SALVAGED BRICK
TYPICAL NOTE: EXIST CEDAR SHAKE ROOFING
7. NEW WINDOW SILLS TO MATCH EXISTING IN MATERIAL, DIMENSION AND PROFILE
CEDAR SHAKE ROOFING - PATCH AS REQ'D
8. NEW TRIM TO MATCH EXISTING MATERIAL AND DETAIL
- PATCH AS REQ'D 9. NEW ROOF TO MATCH EXISTING SHAKE ROOF
10. REPLACE OVERHEAD GARAGE DOORS ISSUED FOR: DATE:
TYPICAL NOTE: EXIST WOOD 11. REPLACE EXISTING FRONT DOOR - FIT TO EXISTING OPENING
SIDING AND TRIM - PRIME 12. AREAS OF NEW EXTERIOR WALL CONSTRUCTION TO BE SET ON FROST FOOTING
FOR NEW PAINT FINISH SD REVIEW 05.26.23
ZONING REVIEW 06.19.23
TYPICAL NOTE: EXIST Y
WOOD SIDING AND
TRIM - PRIME FOR NEW Z
PAINT FINISH
T/EXIST. SECOND FLR
+9'-3" (V.I.F.)
PRIVATE
EXIST CEDAR SHAKE
ROOFING - PATCH AS
REQ'D
RESIDENCE
EXIST WOOD TRIM 789 HUMBOLDT AVE
PRIME FOR NEW
PAINT FINISH
WINNETKA, IL 60093
B1 C B
U V1 W V U P S S P T/EXIST. FIRST FLR
0'-0" (V.I.F.)
GRADE
NEW STEEL RAIL AND TYPICAL NOTE: EXIST NEW STEEL STILE AND NEW STONE CLAD EXIST MASONRY
NEW M.O. WITH ALUM CLAD TYPICAL NOTE: NEW ALUM CLAD NEW M.O. WITH ALUM CLAD
-1'-5" (V.I.F.)
PROPOSED
WINDOW UNIT AND LIMESTONE WINDOW UNIT IN EXIST WINDOW UNIT AND LIMESTONE
PANEL SECTIONAL
OVERHEAD GARAGE
MASONRY
TUCKPOINT AS REQ'D
RAIL DOOR+ MUNTIN W/
TEMPERED GLASS PANELS
TREADS AND RISERS
AND NEW METAL
TUCKPOINT AS REQ'D SILL TO MATCH EXISTING OPENING/EXIST SILL (NEW
BRICKMOLD OR TRIM AS REQ'D)
SILL TO MATCH EXISTING
EXIST WOOD TRIM -
EXTERIOR
DOORS IN EXIST IN EXIST OPENING RAILING
OPENINGS
PRIME FOR NEW
PAINT FINISH ELEVATIONS
SOUTH ELEVATION
1 scale: 1/4" = 1'-0"
A3.0
Page 15 of 16
EXIST CEDAR SHAKE
ROOFING - PATCH AS
REQ'D
EXIST WOOD TRIM -
PRIME FOR NEW
ps
PAUL STUDIO DESIGN
PAINT FINISH 845 WEST FULLERTON
CHICAGO, IL 60614
PAULSTUDIO@ME.COM
1 .401.40 5
NEW CEDAR SHAKE
ROOFING TO MATCH EXIST WOOD SIDING -
EXISTING PRIME FOR NEW
PAINT FINISH
AA BB AA X
NEW METAL RAILING
PAINTED FINISH
12
6.5 T/EXIST. SECOND FLR
+9'-3" (V.I.F.)
NEW EAVE TRIM TO
MATCH EXISTING DETAIL
EXIST CEDAR SHAKE
NEW WOOD SIDING - ROOFING - PATCH AS
FINISH TO MATCH REQ'D
EXISTING HOUSE
SALVAGE AND REUSE H H1 H2 F EXIST WOOD TRIM
EXISTING LIMESTONE SILL E PRIME FOR NEW
F
PAINT FINISH
EXISTING BRICK WITH
TOOTHED IN BRICK INFILL
J EX
T/EXIST. FIRST FLR
0'-0" (V.I.F.)
GRADE
-1'-5" (V.I.F.)
NEW M.O. WITH STEEL LINTEL IN EXIST EXIST MASONRY EXIST MASONRY
MASONRY WITH LIMESTONE SILL TO TUCKPOINT AS REQ'D TUCKPOINT AS REQ'D
NEW CONSTRUCTION NEW CONSTRUCTION EXIST CONSTRCUTION
MATCH EXISTING
OVER EXISTING
TUCKPOINT AS REQ'D EXIST WOOD SIDING -
FOUNDATION
PRIME FOR NEW
PAINT FINISH
WEST ELEVATION
2 scale: 1/4" = 1'-0"
GENERAL NOTES:
1. REPLACE ALL WINDOWS - VIF OPENINGS - SIZE TO FIT (BRICKMOLD IN M.O. )
2. REPAIR EXISTING SHAKE ROOF
3. REPAIR (OR REPLACE IN KIND) EXISTING METAL ROOF AT FRONT BAY
4. REPAIR OR REPLACE IN KIND EXISTING SIDING AND TRIM - PREPARE WITH PRIME
FOR NEW PAINT FINISH
5. REPAIR AND TUCKPOINT EXISTING BRICK
6. AREAS OF NEW BRICK TO MATCH EXISTING - DO NOT USE SALVAGED BRICK
7. NEW WINDOW SILLS TO MATCH EXISTING IN MATERIAL, DIMENSION AND PROFILE
EXIST CEDAR SHAKE
8. NEW TRIM TO MATCH EXISTING MATERIAL AND DETAIL
ROOFING - PATCH AS
9. NEW ROOF TO MATCH EXISTING SHAKE ROOF
REQ'D
10. REPLACE OVERHEAD GARAGE DOORS
11. REPLACE EXISTING FRONT DOOR - FIT TO EXISTING OPENING
12. AREAS OF NEW EXTERIOR WALL CONSTRUCTION TO BE SET ON FROST FOOTING
EXIST WOOD SIDING
AND TRIM - PRIME
FOR NEW PAINT
FINISH
EXIST CEDAR SHAKE
ROOFING - PATCH AS
REQ'D
EXIST WOOD TRIM ISSUED FOR: DATE:
AND SIDING - PRIME
FOR NEW PAINT
NEW CEDAR SHAKE SD REVIEW 05.26.23
FINISH
ROOFING TO MATCH ZONING REVIEW 06.19.23
EXISTING
NEW EAVE TRIM TO
MATCH EXISTING DETAIL
X
EXIST CEDAR SHAKE
ROOFING - PATCH AS
REQ'D T/EXIST. SECOND FLR
+9'-3" (V.I.F.)
EXIST WOOD TRIM -
PRIME FOR NEW
PAINT FINISH
PRIVATE
RESIDENCE
789 HUMBOLDT AVE
A N
WINNETKA, IL 60093
D T/EXIST. FIRST FLR
M
P R Q P 0'-0" (V.I.F.)
GRADE
EXIST MASONRY
EXIST WOOD TRIM -
EXIST MASONRY
-1'-5" (V.I.F.)
EXISTING BRICK WITH PROPOSED
PRIME FOR NEW TOOTHED IN BRICK INFILL
TUCKPOINT AS REQ'D PAINT FINISH TUCKPOINT AS REQ'D
EXIST CONSTRUCTION NEW CONSTRUCTION
EXTERIOR
OVER EXISTING
FOUNDATION ELEVATIONS
EAST ELEVATION
1 scale: 1/4" = 1'-0"
A3.1
Page 16 of 16