Planning Commission
Regular MeetingCookeville, TN · December 13, 2021
Minutes
Cookeville Planning Commission Minutes
December 13th, 2021
Rescheduled from December 27th, 2021
The Cookeville Planning Commission met on Monday, December 13th, 2021, at 5:30 p.m., in the
Council Chambers, 45 E. Broad Street, Cookeville, Tennessee.
MEMBERS PRESENT: Jim Cobb, Chad Gilbert, Judy Jennings, Lauren Metts, Jim Stafne, Kay
Starkweather & Jim Woodford.
MEMBERS ABSENT: Leslie Sullins & Eric Walker.
STAFF MEMBERS PRESENT: Jon Ward, Christopher Phillips, Ken Young & Haley Dickson.
STAFF MEMBERS ABSENT: James Mills
OTHERS PRESENT: Betsy Scarsisbrick, Lindsay Pride
ESTABLISHMENT OF QUORUM: Chairman Stafne announced that a quorum was present for the
meeting.
CONSIDER FOR APPROVAL THE AGENDA AS SUBMITTED. Kay Starkweather made the
motion to approve the agenda as submitted. Jim Woodford seconded the motion and the motion
carried unanimously. APPROVED.
CONSIDER FOR APPROVAL THE MINUTES OF NOVEMBER 22ND, 2021. Jim Woodford
made the motion to approve the minutes of November 22nd, 2021. Kay Starkweather seconded the
motion and the motion carried unanimously. APPROVED.
CONSIDER FOR ACTION THE PRELIMINARY PLAT OF HIGHBURY SUBDIVISION,
147 LOTS LOCATED ON NEAL STREET & EAST VETERANS DRIVE. REQUEST
SUBMITTED BY CHAD GILBERT OF PUTNAM CONTRACTING SERVICES, LLC ON
BEHALF OF JARED SMITH & JEANETTE GAW. Jon Ward stated that Mr. Chad Gilbert with
Putnam Properties, on behalf of Jared Smith and Jeanette Gaw, has submitted for approval a
preliminary plat for Highbury Subdivision, a 147-lot single-family cluster development located on
Neal Street and East Veterans Drive.
Analysis: The subject property is identified as a portion of Tax Map 066, Parcel 032.00 and contains
approximately 18.81 acres. The property is zoned CG, “General Commercial” as are the adjacent
properties to the east, south, and west. The adjacent properties to the north are zoned CR, “Regional
Commercial.” Section 222.3A of the Zoning Code stipulates single-family detached cluster
developments are allowed in the CG zone as a use permitted on review, subject to the submission of a
plat in accordance with the Cookeville Subdivision Regulations.
The development consists of 146 single-family detached building lots and the construction of three
(3) private streets and installation of utilities. New five (5) foot wide ADA compliant sidewalks will
be required along Neal Street and East Veterans Drive. New four (4) foot wide sidewalks will be
constructed along each side of the new streets that will be constructed, with single connections to
proposed sidewalks to East Veterans Drive and Neal Street. The remaining lot consists of common
area and is not a building lot.
Three (3) new private streets are proposed as Belfair Street, Meridian Street, and Corsair Way.
Corsair way will provide access off Neal Street and ingress/egress will be restricted to right-in/right-
out. Meridian Street will provide access off East Veterans Drive. Belfair Street will connect Meridian
Street and Corsair Way. Meridan Street extends approximately 1,080 feet from the intersection with
Belfair Street, and ends in a cul-de-sac, with 81 cluster homes proposed along this segment of the
private street. Belfair Street extends approximately 730 feet from the intersection with Corsair Street
and also terminates in a cul-de-sac with 41 cluster homes along this segment of the private street.
Article V, Section J of the Subdivision Regulations restricts dead-end streets to 1,200 feet in length,
Cookeville Planning Commission 2
December 13th, 2021
or twenty (20) lots, whichever is less, unless specifically authorized as a variance by the Planning
Commission. Relative to the number of units, Highbury is proposed as a Cluster Development, which
is not a traditional single-family detached development. The developer must submit grading,
drainage, and street construction plans to Public Works. Public Works also notes the horizontal curve
radius of Meridian Street exceeds the minimum 150 feet and suggests the developer apply for a
variance. Upon consultation with Public Works, the minimum radius requirement is applicable to
speed limits of 30 miles per hour and is not an issue at lesser speeds. The developer does plan to
restrict speed to less than 30 miles per hour. Signage should be installed to reflect the appropriate
design speeds. Public Works also has concerns with how the developer will handle grading at the
northwest corner of the adjacent Cappo Management property.
Water Quality Control notes that the current design of the development should allow all meters to
have at least 20 PSI while the fire hydrant is flowing. Meters are not normally allowed above 1150’
Elevation, but the development is situated adjacent to the water tank. The engineer for the
development may do calculations that show the increased elevation will still have adequate pressure.
If calculations show that all lots will have adequate pressure at the meters (a minimum pressure of 40
PSI) but will not have adequate pressure at the top floor of the dwelling, there must be a note that
those lots without adequate pressure will require a booster pump. Public water will connect to the
existing 12-inch water line located in the East Veterans Drive right-of-way and should also connect to
the eight (8) inch water line located in the Neal Street right-of-way. Private sewer will connect to the
existing eight (8) inch gravity sewer main also located in the Neal Street right-of-way. The developer
must submit state approved water plans to the Department of Water Quality Control for review and
approval prior to construction. Water Quality Control has agreed to allow the water line to be
installed in the center of one (1) of the travel lanes, which will allow one (1) lane to remain open for a
necessary water line repairs. The final plat and the HOA agreement must include a note regarding
property restoration as required by Water Quality Control for maintenance and repairs of the water
line. Existing fire hydrants are located on Neal Street and East Veterans Drive and the construction of
four (4) new fire hydrants is depicted on the plat. All dwelling units will have 303D residential
sprinkler systems.
The Electric Department requires six (6) feet of separation from all other utilities. All transformers
and SEC boxes must be sited per CED requirements. The developer must install all lighting two (2)
feet behind sidewalks. A 10-foot utility or other adequate easement will also be required by the
Electric Department. All utilities must be shown on the plat and the Cookeville Electric Department
will provide the utility layout. All electrical services must be placed on the front or front corner of all
dwellings. The Gas Department states that gas is available for the development, if requested.
The Planning Department notes that under current zoning, this property could accommodate 327 total
units by right. The developer is proposing 146 units including the common area, or 44.6 percent of
the total units allowed. There are concerns with the grading for this development. The Subdivision
Regulations require local street grades to be a maximum of 10 percent, and the Planning Commission
may allow up to 12 percent if there are topographic or other special conditions. The plat depicts areas
within the proposed development limits of the site with grades of up to 18 percent. The developer has
indicated they will achieve a maximum seven (7) percent grade within the proposed private street and
parking areas.
The developer has advised that Scott Nicholson with CES is in the process of preparing all required
engineering plans for the development including stormwater drainage features after the plat is
considered by the Planning Commission. A dumpster will be sited on the property for trash pick-up.
All common areas, sewer, and other infrastructure improvements will be maintained by a Homeowner
Association Agreement that will be required upon final plat recording. No portion of the subject
Cookeville Planning Commission 3
December 13th, 2021
property is in a Special Flood Hazard Area according to the Flood Insurance Rate Maps for the
area,nor is there any indication of Sinkhole Retention Areas according to the available GIS data. The
developer must coordinate Centralized Delivery Unit locations with the United States Postal Service.
Recommendation: Approval of a variance to the minimum curve radius exceeding 150 feet, subject
to speed limit signage reflecting the appropriate design speed as approved by Public Works and
approval of the plat subject to the following:
Plat shall be revised to add typical street cross section
Plat shall be revised to depict utilities per Public Works
Plat shall be revised to depict stormwater detention and stormwater facilities per Public Works
Developer must schedule a pre-construction meeting with all the appropriate city departments
Developer must submit a roadway plan and profile with storm sewer and sidewalk details to the
Department of Public Works. Plan shall include typical road section, subgrade, base width,
asphalt width, and 3:1 maximum slope
Developer shall submit grading plans including drainage plans, storm water detention and water
quality upon request to the Department of Public Works
Developer must coordinate dumpster location for trash pick-up with Public Works
Developer must submit state approved water plans to the Water Quality Control Department
Developer must submit calculations showing adequate water pressure or provide note stating
booster pumps will be necessary
Developer shall submit plans for the installation of underground electric per the Electric
Department design requirements
Developer shall provide all conduit for underground communications, CAD files, and electrical
layout plan to Frontier Communications
Developer shall provide all utility easements as required by the Electric and Water Quality
Control Departments
Completion of corrections or additions to the plat as determined necessary by the Planning
Department and/or other appropriate city departments
Jim Cobb asked if the booster water pump is for domestic water or sprinkler pressure.
Jon Ward stated that the booster pump meets the PSI (40 PSI) and the sprinkler system is compliant
either way.
Kay Starkweather asked if developers have used booster pumps on any other developments before.
Jon Ward stated that he will have to review other plans and he believes that with the proximity to the
water tank, that the pressure will be sufficient.
Jim Cobb asked since the streets are private, if the police have any jurisdiction on enforcing the speed
limit.
Jon Ward stated that the speed limit signs will be a suggestion and the streets will be treated as a
parking lot since parking will be on both sides of the road.
Jim Woodford asked if there is a common area for additional parking.
Jon Wards stated that the proposed parking spaces exceed the requirement. The developers have not
finalized the number of bedrooms in each of the dwelling units but there was a surplus on the
Cookeville Planning Commission 4
December 13th, 2021
preliminary plat for additional parking. The number of parking spaces will be finalized when the
number of bedrooms are finalized.
Keith Lilly, who lives on South Maple Avenue, stated that the photo in newspaper listed number of
dwellings. Mr. Lilly is concerned with the traffic that this development will create. He states that
traffic is already busy on the intersection where this development is going. He believes that since
more people will be living in that area, he wants to make sure all of sidewalks and bike paths will be
implemented from the 2019 Pedestrian & Bicycle Plan to help keep people off the road.
Mr. Lilly asked if traffic signals have been thought of for the intersection of where this development
will connect to East Veterans Drive since traffic often gets backed up on that road.
Jon Ward stated that single-family development doesn’t typically cause high traffic volumes and we
haven’t seen problems that far west on East Veterans Drive.
Mr. Lilly stated that he is in favor of development, but he wants to make sure the 2019 Pedestrian &
Bicycle Plan is thought of during the construction.
Jim Cobb made the motion to approve the request submitted by staff. Jim Woodford seconded the
motion and the motion carried unanimously. Votes: Jim Cobb – aye, Chad Gilbert – abstain, Judy
Jennings – aye, Lauren Metts – aye, Jim Stafne – aye, Kay Starkweather – aye & Jim Woodford –
aye. CONDITIONAL APPROVAL.
Study Items:
(1) Consider for study the rezoning of 5250 Tennessee Avenue (Tax Map 064 Parcel 032.00) from
RS-20 (Single-Family Residential) to CI (Commercial-Industrial Mixed Use). Request
submitted by Curtis Williams.
Kay Starkweather made the motion to approve the request submitted by staff. Jim Woodford
seconded the motion and the motion carried unanimously. APPROVED.
Staff Reports:
(1) Minor Plats Approved & Recorded:
West Cookeville Subdivision, two (2) lots located at 555 & 559 West Broad Street – Gregory
Cooper
Walter Whitson Carlen Jr. Combination Plat, one (1) lot located at 357 & 369 Hughes Street –
Walter Whitson Carlen, Jr.
ADJOURNMENT: 6:11 P.M.
SUBMITTED FOR APPROVAL SUBMITTED FOR RECORDING
____________________________ _________________________________
Haley Dickson Jim Stafne, Chairman
Planning Assistant Cookeville Planning Commission
Get email alerts for Cookeville
A daily email when new agendas and minutes are posted.