Planning & Zoning
Regular MeetingFarmington, NM · January 28, 2021
Agenda
AGENDA
Planning & Zoning Commission
City Council Chambers – 800 Municipal Drive
January 28, 2021 - 3:00 p.m.
This meeting will be held virtually using Zoom at:
https://us02web.zoom.us/j/83289559856
Item
1 Call Meeting to Order
2 Approval of the Agenda
3 Approval of the Minutes of the January 14, 2021 P&Z Meeting
4 Petition No. PP 20-59 (Discussion/Possible Action) - a request
from Mike Smith, property owner, represented by Alex Johnson of
Johnson Mapping and Surveying, for a preliminary plan review of a
six-lot subdivision in Tier 2 of the Planning & Platting Jurisdiction of
the City of Farmington. Property is located in Flora Vista, and
unincorporated city within San Juan County. (Beth Escobar)
5 Business From:
Floor:
Chairman:
Members:
Staff:
6 Adjournment
The recommendation of the Planning and Zoning Commission is scheduled to be considered at
the City Council Meeting on Tuesday, February 9, 2021.
ATTENTION PERSONS WITH DISABILITIES:
The meeting room and facilities are fully accessible to persons with mobility disabilities. If you plan to attend a
meeting and need an auxiliary aid or service, please contact the City Clerk's office at 599-1101 or 599-1106, prior to
the meeting so arrangements can be made.
Meeting Minutes
Planning & Zoning Commission
January 14, 2021
The Planning & Zoning Commission met in a regular session on January 14, 2020 at 3:00
p.m. in the City Council Chambers, 800 Municipal Drive, Farmington, New Mexico via Zoom
at https://us02web.zoom.us/j/86060354302.
P&Z Members Present: Chair-Joyce Cardon
Vice Chair-Clint Freeman
Ryan Brown (via Zoom)
Shay Davis
Elizabeth Lockmiller
Cheryl Ragsdale
Mitch Sewell
Gary Smouse (via Zoom)
P&Z Members Absent: Cody Waldroup
Staff Present: Andrea Jones
Beth Escobar
Elizabeth Sandoval
Others Who Addressed the Commission (Via Zoom Virtual Platform): Robert Echols
Call to Order
Chair Joyce Cardon called the meeting to order at 3:00 p.m. There being a quorum present
the following proceedings were duly had and taken.
Presentation & Approval of the Agenda
There were no changes to the agenda. A motion was made by Vice Chair Freeman and
seconded by Commissioner Sewell. A roll call vote was taken and this motion was approved
unanimously by a 7-0 vote.
Approval of the Minutes
A motion was made by Commissioner Sewell and seconded by Commissioner Davis to
approve the minutes of the December 10, 2020 P&Z Meeting. A roll call vote was taken and
this motion was approved unanimously by a 7-0 vote.
Swearing in of Witnesses
Witnesses were sworn in by Elizabeth Sandoval, Administrative Assistant.
Note
Commissioner Smouse joined the meeting via Zoom.
Petition No. PP 20-56
Beth Escobar, Planning Manager, presented Petition No. PP 20-56, Little Creek Subdivision
Phase VII.
Petition from Joe & Stan, LLC - Joe Kozimor, Manager
Representative: Robert Echols, Cheney-Walters-Echols
Location: Parcel No. 2080172214410, located at the north terminus of Sparrowhawk Dr.
and Soaring Eagle Dr.
Existing Zoning: SF-7, Single-family residential
The applicant is requesting Preliminary Plan approval per Section 8.8.9.D of the Unified
Development Code. The Preliminary Plan review provides for identification of any issues
and determination of compliance with all regulations. The Planning & Zoning Commissions
is being asked to make a recommendation. Council provides final approval of a Preliminary
Plan. The Final Plat may then be submitted.
The petitioner is requesting preliminary plan approval for the Little Creek Subdivision Phase
VII, Class 1, a 13-lot subdivision on a 24.15-acre undeveloped parcel located north of the
terminus of Sparrowhawk Drive in West Farmington. Lot sizes for Phase VII range from
1.23 acres to 2.31 acres.
The proposed subdivision is an addition to previous Little Creek Subdivisions developed on
properties to the south.
Phase VII includes two non-buildable lots, numbers 11 and 12. Lot 12 has an existing gas
well and supporting infrastructure as well as a solar array. The topography of Lot 11 is too
challenging to support development.
Lot numbers 3, 4 & 6 are impacted by an existing gas line. Buildings must be set back 30
feet from the gas line easement.
Standard review agencies have commented on the plat. Majority of comments have been
addressed. Discussion regarding drainage is ongoing.
Staff concludes approval of Petition 20-56, a preliminary plan for Little Creek Subdivision
Phase VII, is appropriate, subject to technical and corrective changes as identified.
Staff Recommendation
The Community Works Department recommends approval of Petition 20-56, a request from
Joe and Stan, LLC (Joe Kozimor, Manager) represented by Robert Echols of Cheney-
Walters-Echols, Inc. for a preliminary plan of a Class 1, 13-lot subdivision on a 24.15-acre
undeveloped parcel located north of the terminus of Sparrowhawk Drive in West
Farmington. The lot sizes for Phase VII range from 7,000 square feet to 2.53 acres.
All technical corrections to the plat and construction drawings will be finalized and approved
prior to submittal of the final plat, including the drainage report.
Discussion
Chair Cardon asked the Commissioners if they had questions of staff.
Commissioner Sewell asked if the easement for the gas line was from the edge of the
easement.
Planning Manager Escobar stated that since it is centered it is from both sides.
Commissioner Freeman asked if was it is 30 feet from the gas line or 30 feet easement.
Planning Manager Escobar stated 30 feet from the edge of the easement. The plat does
include the setbacks for the lots that are impacted by the gas line. All lots are buildable,
except for lot eleven.
Chair Cardon asked if the petitioner or the petitioner’s representative were present.
Robert Echols, the petitioner’s representative, stated that he is representing Joe and Stan
Kozimor and agrees with staff’s recommendation for approval.
Chair Cardon asked if the Commissioners had any questions for Mr. Echols.
Chair Cardon asked if there were any interested parties that would like to speak.
There were none.
Chair Cardon asked if there was a Commissioner prepared to make a motion regarding PP
20-56.
A motion was made by Vice Chair Freeman and seconded by Commissioner Ragsdale
to approve Petition No. PP 20-56, a request from Joe and Stan, LLC (Joe Kozimor,
Manager) represented by Robert Echols of Cheney-Walters-Echols, Inc. for a preliminary
plan of a Class 1, 13-lot subdivision on a 24.15-acre undeveloped parcel located north of
the terminus of Sparrowhawk Drive in West Farmington. The lot sizes for Phase VII range
from 7,000 square feet to 2.53 acres. Also including that all technical corrections to the plat
and construction drawings will be finalized and approved prior to submittal of the final plat,
including the drainage report.
A roll call vote was taken and this motion was approved unanimously by an 8-0 vote.
Chair Cardon stated that this petition will move forward to City Council and will be heard at
the January 26, 2021 City Council meeting.
Business from the Floor: There was no business from the Floor.
Business from the Chair: There was no business from the Chair.
Business from the Members: There was no business from the Members.
Business from Staff: Planning Manager Escobar stated that two more preliminary plans
have been submitted to the Planning Division and will be brought forward to the Planning &
Zoning Commission.
Adjournment: With no further business and a motion by Commissioner Sewell and
seconded by Commissioner Ragsdale, the Planning & Zoning Commission meeting of
January 14, 2021 was adjourned at 3:18 p.m. A roll call vote was taken and this motion to
adjourn was approved by an 8-0 vote.
_________________________________ _______________________________________
Joyce Cardon Elizabeth Sandoval
Chair Administrative Assistant
COMMUNITY WORKS
STAFF REPORT
SCALES SUBDIVISION
Petition No. PP 20-59
A. STAFF REPORT, January 28, 2021
PROJECT INFORMATION
Applicant Michael L. Smith
Representative Alex Johnson with Johnson Mapping and Surveying
Date of Application December 17, 2020
Requested Action Preliminary Plan Approval
Location Parcel # R0010977, Flora Vista. West of County Road 3450
Existing Zoning Unincorporated San Juan County
Surrounding N/A
Surrounding properties are developed as
Zoning and Land
residential
Use
Subdivision Class Class 3, Tier 2
Notice Preliminary Plans do not require notice
Staff Planner Beth Escobar, Planning Manager
SUBDIVISION INFORMATION
Number of Lots 6 lots
Acres of Land 8.67 acres
Minimum Lot Size 1 acre
Utilities Water: Flora Vista Mutual Domestic Water Association
Sewer: Private Septic Systems
Electric: Per FEUS Engineering
Access &
Per City Standards
Circulation
Street Lights Per City Standards
Street Sign Per City Standards
Fire Hydrants Per City Standards
Drainage Per City Standards
P & R’s Fees Per City Standards
NBU Mail Box Coordinate with USPS
1
Staff Report PP 20-59 Scales Subdivision Page 2
GENERAL INFORMATION
The petitioner is requesting preliminary plan approval for the Scales Subdivision, a
proposed subdivision of an 8.67-acre parcel located in Flora Vista, an unincorporated
area of San Juan County.
The petitioner is submitting this as an exemption plat to San Juan County. Newly
created lots will be transferred to family members of the petitioner in accordance with
New Mexico Statute 47-6-2.L.9.
The subject property is located in Tier 2 of the City of Farmington’s Planning and Platting
Jurisdiction. Subdivisions in Tier 2 are subject to all of the regulations in Chapter 6 –
Subdivision Standards of the UDC except for the following:
The requirements of section 6.4, subdivision design standards, shall apply to all rural
residential subdivisions, with the following modifications.
6.5.2 Blocks. Block length shall not exceed 1,500 feet in rural residential subdivisions. In
blocks over 800 feet in length, accessways, as defined herein, may be required near the
center of the block and at the end of a cul-de-sac to facilitate pedestrian traffic
movement.
6.5.3 Streets and alleys.
A. Streets shall comply with the requirements of section 6.4.7; provided, however,
that streets Class 2 and 3 subdivisions shall have:
(1)All weather, gravel or crushed stone base;
(2)Road surfaces with not less than a double penetration chip seal surface; and
(3)Road surface width of not less than 24 feet; and
(4)Eight-foot shoulder on each side.
B. Minimum rights-of-way width shall be 52 feet; provided, however, that minimum
rights-of-way for all thoroughfares, as shown on the City of Farmington Major
Thoroughfare Plan, which cross or form a subdivision boundary, shall be in
accordance with the requirements of subsection 6.4.7J., geometric standards—
street design criteria.
6.5.4 Pedestrian, biking and multi-use facilities.
A. Sidewalks are not required on residential and collector streets that are wholly
contained within rural residential subdivisions. If sidewalks are provided or
required, they shall meet all regulations in section 6.4.8, pedestrian, biking and
multi-use facilities, and shall be constructed away from the roadway surface to
provide adequate safety for pedestrians.
B. Sidewalks are required on all collectors and arterials that will continue beyond the
rural residential subdivision(s) and are required to be constructed in accordance
with the requirements of section 6.4.7, streets and alleys. Sidewalks on these
streets shall comply with the requirements of section 6.4.8, pedestrian facilities.
C. Biking facilities are not required.
2
Staff Report PP 20-59 Scales Subdivision Page 3
Lots #5 and #6, as shown on the Preliminary Plan, are encumbered by a ditch easement
and gas well infrastructure including a wellhead and gas pipeline for Lumen
Technologies.
The plat shows potential building envelopes for these lots.
Tier 2 properties are within 3 miles of the City boundaries. Although no specific study for
potential annexation in this area has been conducted, it is reasonable to assume that
annexation of the Flora Vista area is a possibility. It is important therefore to control
development to prevent the inheritance of problem areas. This is the purpose of the
State assigned Planning and Platting Jurisdiction (PP & J).
Both the 2002 Farmington Comprehensive Plan and the 2040 Draft Comprehensive Plan
reflect concerns about development in fringe areas that do not provide adequate
infrastructure.
ISSUES IDENTIFIED DURING INITIAL REVIEW
Fire Department – Kipp Rix: (505) 566-2361 and krix@firenet.org
• International Fire Code (IFC)
• 503.2.1 - Fire access roads shall have width of not less than 20' and a vertical
clearance of not less than 13' 6"
• Appendix "D"
• D103 - Drive surface capable of supporting at least 75,000 lbs
• D103.2 - Roads not exceed 10 percent grade
• D103.4 - Dead end roads in excess of 150' shall have an approved turn around
Engineering Staff –Toni Sitta: 599-1399 and tsitta@fmtn.org
• The proposed preliminary plan does not meet City of Farmington Subdivision
standards for a Class 3, Major Subdivision in the Tier II Planning and Platting
Jurisdiction (UDC 6.4.5; 6.4.3; 13.1.12, etc.).
• Each lot must front upon a public street with a right of way width of not less than
50 feet (UDC 6.4.5).
• Streets that serve Class 2 and Class 3 subdivisions shall have: All weather,
gravel or crushed stone base; road surfaces with not less than a double
penetration chip seal surface; and road surface width of not less than 24 feet;
and eight foot shoulder on each side.
• Minimum right of way shall be 52 feet in rural residential subdivisions (Tier 2).
• Please submit a contour map of the proposed subdivision and a drainage report
in accordance with UDC 13.2.12 (F) & (L). (This has been received.)
• The existing 25-foot Hillside Dr. public street has not been constructed. The City
requires that the developer construct the access and street (Walnut Ave and
Hillside Dr.) in accordance to subdivision standards per the City UDC.
• What is the feasibility of Lots 5 and 6 for development? It appears that the
fenced area is all wellsite, with wellsite equipment. Has this equipment been
removed? Please show the building envelope and area on the two lots. (These
building envelopes are indicated in the revised plan.)
3
Staff Report PP 20-59 Scales Subdivision Page 4
Water/Wastewater-Manuel Tso 599-1315 and mtso@fmtn.org
• Recommend showing Access and Utility Easement for Lot 5 & 6. (This comment
is addressed in the revised version of the Preliminary Plan.)
Per Section 8.8.4 of the Unified Development Code, all subdivisions shall comply with
the following minimum standards:
A. Design and improvement standards. All subdivisions shall be designed and
constructed in accordance with applicable requirements of:
(1) Article 5, development standards; and
(2) Article 6, subdivision design and improvements.
Staff Comments: Through staff review, the plat as presented does not meet the
following development standards and design and improvement requirements of
the UDC:
1. Section 6.4.5.2: Each lot must front upon a public street with a right-of-way
width of not less than 50 feet.
a. Lots 1, 2, 3 & 4 front South Hillside a 25-foot wide public street.
b. Lots 5 and 6 front an undedicated portion of County Road 3450.
2. Section 6.5.3.A: Streets in Tier 2 for Class 3 subdivisions shall be all
weather, gravel or crushed stone base. Double penetration chip seal
surface with a road surface width of not less than 24 feet and an eight-foot
shoulder on each side.
a. South Hillside is currently undeveloped, with a dirt surface.
B. Waivers. The commission may recommend and the council may approve,
approve with conditions, or deny waivers of the standards in section 6.4,
subdivision design standards, during the platting process.
Staff Comments: The petitioner is requesting waivers to the above listed
requirements of Section 6.4.5.2 & 6.5.3.A of the UDC.
The proposed access for lots 1-4, Hillside Drive, is 25 feet wide which does meet
fire code requirements. The southern terminus of Hillside Drive would be required
to have an approved turnaround.
County Road 3450, providing access to lots 5 & 6, is also 25 feet wide.
Surfaces for both roads would need to be confirmed for adequacy by the Fire
Department.
C. Zoning consistency. All subdivisions and the resulting lots shall be consistent
with the requirements of the applicable underlying zone district.
Staff Comments: San Juan County does not have zoning regulations. Single-
family residential development is consistent with existing zoning in the area.
4
5
Staff Report PP 20-59 Scales Subdivision Page 6
6
Staff Report PP 20-59 Scales Subdivision Page 7
Subject Property
7
Preliminary Plat Sheet 1
8
9
Staff Report PP 20-59 Scales Subdivision Page 10
STAFF CONCLUSION
Staff concludes approval of Petition 20-59, Scales Subdivision is not appropriate as the
application is not in compliance with the City of Farmington development standards,
subdivision regulations and fire code requirements.
STAFF RECOMMENDATION
The Community Works Department recommends denial of Petition 20-59, a request
from Michael Smith for preliminary plan approval for the Scales Subdivision, a proposed
subdivision of a 8.67-acre lot located in Flora Vista, and unincorporated area of San
Juan County.
10
Staff Report PP 20-59 Scales Subdivision Page 11
PLANNING MEMO COMMENTS SUMMARY
PP 20-59 SCALES SUBDIVISION
Deadline: 12-29-2020
City of Farmington Departments
CW Planning Manager – B. Escobar
CW Addressing – Planning Division
CW Chief Building Official – D. Childers No Comment
CW Long Range Planner
CW MPO
CW Oil & Gas Inspector
CITY City Manager’s Office – J. Baird No Comment
Customer Care Manager – L.
ELEC
Richardson
"The plat does not show Overhead Electrical (OHE)
ELEC
line easements. I will send you my final comment on
the "Comment Page" as soon as I receive the plats
Electrical Engineering –Roberto Ga
showing those OHE lines.
1/19/21 – No Comment
ELEC T & D – Field Op – L. Lugenbeel
International Fire Code (IFC)
FIRE
503.2.1 - Fire access roads shall have width of not
less than 20' and a vertical clearance of not less than
13' 6"
Fire Captain – K. Rix Appendix "D"
D103 - Drive surface capable of supporting at least
75,000 lbs
D103.2 - Roads not exceed 10 percent grade
D103.4 - Dead end roads in excess of 150' shall have
an approved turn around
FIRE Fire Marshall – B. Vega
LEGAL City Attorney – J. Breakell
LEGAL Deputy City Attorney – E. Wayne No Comment
POLICE Code Compliance – M. Romero No Comment
POLICE Sergeant – S. Goodsell
PRCA S. Reeves / R. Crosby No Comment
PRCA ORII – W. Unsicker
CW City Engineer – N. Westerling
CW 1) The proposed preliminary plan does not meet
City of Farmington Subdivision standards for a
Engineering – T. Sitta Class 3, Major Subdivision in the Tier II
Planning and Platting Jurisdiction (UDC 6.4.5;
6.4.3; 13.1.12, etc.).
11
Staff Report PP 20-59 Scales Subdivision Page 12
a. Each lot must front upon a public street
with a right of way width of not less than
50 feet (UDC 6.4.5).
b. Streets that serve Class 2 and Class 3
subdivisions shall have: All weather ,
gravel or crushed stone base; road
surfaces with not less than a double
penetration chip seal surface; and road
surface width of not less than 24 feet;
and eight foot shoulder on each side.
c. Minimum right of way shall be 52 feet in
rural residential subdivisions (Tier 2).
d. Please submit a contour map of the
proposed subdivision and a drainage
report in accordance with UDC 13.2.12
(F) & (L).
2) The existing 25 foot Hillside Dr. public street has
not been constructed. The City requires that the
developer construct the access and street (Walnut
Ave and Hillside Dr.) in accordance to
subdivision standards per the City UDC.
3) What is the feasibility of Lots 5 and 6 for
development? It appears that the fenced area is
all wellsite, with wellsite equipment. Has this
equipment been removed? Please show the
building envelope and area on the two lots.
CW Streets Superintendent – C. Fuller
CW Traffic Engineer – I. BlueEyes
1) Recommend showing Access and Utility
CW Water/Waste Water – M. Tso
Easement for Lot 5 & 6.
Other Entities
New Mexico Gas Company – R. Castillo
CenturyLink – D. Willato No Comment
Enterprise Field Services – M. Waszut
Comcast Cable – M. Johnson
JACOBS CH2MHILL OMI
Surface Land Negotiator for BP – M. Venzara
Farmington School District – C. Lyons
12
Get email alerts for Farmington
A daily email when new agendas and minutes are posted.