MINUTES OF THE GILBERT COUNCIL SUBCOMMITTEE ON BUILDING CODES, FEBRUARY
6, 2019, AT 4:30 P.M., ROOM 100, 90 EAST CIVIC CENTER DRIVE, GILBERT, ARIZONA
COUNCIL PRESENT: Chair Jared Taylor and Councilmembers Scott Anderson
and Aimee Yentes
COUNCIL ABSENT: none
STAFF PRESENT: Town Clerk Lisa Maxwell, Development Services
Director Kyle Mieras, Plan Review and Inspection Manager
Larry Taylor, Fire Marshal Dan DuBois
CALL TO ORDER
Chair Taylor called the meeting to order at 4:34 p.m.
AGENDA ITEMS
1. Approval of the minutes of the January 15, 2019 meeting.
A MOTION was made by Councilmember Anderson, seconded by Chair Taylor, to
approve the minutes of the January 15, 2019 meeting. Motion carried 2-0 with
Councilmember Yentes not present for the vote.
2. Report on presentation to the Gilbert Chamber of Commerce.
Plan Review and Inspection Manager Taylor met with the Gilbert Chamber of Commerce
a couple of weeks ago. He gave a presentation on the Commercial Building Codes. He
reported the feedback he received was positive. The 2018 Building Codes are viewed as
being pro-business friendly.
3. Presentation of significant changes to the 2018 Building Codes.
2018 International Residential Code (IRC):
R101.2 Scope/R202 Definitions: This update allows accessory structures to be three
stories with no size limitation. The previous IRC only allowed a two story structure of
3,000 square feet.
R301.2(4)A & B Ultimate Design Speeds: The wind speed maps were changed to match
the International Building Code (IBC). It was 90 miles per hour and it changed to 115
miles per hour.
Table R302.1(1) Exterior Walls: This update allows building to be located closer to the
lot line if fireblocking is installed between the wall top plate and roof sheathing.
Fireblocking is slow burning and it gives the fire department time to get to scene.
Table R302.1(1) Exterior Walls: Penetrations are permitted a minimum of three feet
from the property line without special treatment.
R304.1 Minimum Area: The requirement for one habitable room with a minimum of 120
square feet was removed.
R305.1 Ceiling Height: The ceiling height for bathrooms, toilet rooms and laundry rooms
was to a minimum of 6 feet eight inches. Obstructions such as beams are ducts are now
allowed at a minimum height of six feet four inches from the finished floor.
R308.4.2 Glazing: The location of glass with safety glazing was defined.
R308.4.4.1 Structural Glass Baluster Panels: A top rail is required.
R310.1 Emergency Escape and Rescue Openings: These are no longer required for
bedrooms in basements if there are fire sprinklers and there is at least one emergency
escape and rescue opening in the basement.
R311.7.3 Stairways: The maximum vertical rise between floor levels or landings
increased to twelve feet seven inches.
311.7.8.2 Handrail Projections: A new exception allows handrails to project a maximum
of 6 feet six inches into a stairway in certain circumstances.
R311.7.10.1 Spiral Stairways: The requirement for a center post was removed.
R311.7.11 Alternating Tread Devices and R311.7.12 Ships Ladders: These are now
permitted as access to lofts and mezzanines that are no more than 200 square feet.
R311.8 Ramps: The grade can be steeper the ramp is not serving the egress door.
R312.1.2 Guards: The height of the rail would now be measured from floor.
R314 Smoke Alarms: The exception for interconnecting additional smoke alarms was
removed. Wireless smoke alarms are allowed.
R315.3 Carbon Monoxide Alarm Location: Required in bedrooms where a fuel-burning
appliance is present in the bedroom or attached bathroom.
R315.5 Carbon Monoxide Alarm Interconnectivity: Whenever more than one alarm is
required they must be interconnected.
R315.6 Power Source: Carbon monoxide alarms must be connected to the building’s
wiring.
R324.6.2.2 Solar Panel Installation: Panels cannot be located below an escape or rescue
opening.
R325 Mezzanines: New addition to IRC with provisions for mezzanines.
R327 Stationary Storage Battery Systems: New addition to the IRC gives provisions for
battery storage. They may be installed in non-habitable spaces and ventilation
requirements must be followed.
Table R502.3.1 Floor Joist Spans, Table R802.4 Ceiling Joist Spans, and Table R802.5
Rafter Spans: There are minor changes to span length.
Energy Efficency:
N1101.13 Compliance: This update provides three paths for compliance.
N1102.1.3 R-value Computation: Insulated siding can be used in the calculation for
satisfying the insulation R-value.
N1103.3 Duct Sealing and Testing: Leakage rates are no longer mandatory.
1104.1 Lighting Systems: The percentage of high efficacy light bulbs in permanently
installed light fixtures increased to 90 percent.
Table N1106.4 Maximum Energy Rating Index: This increased to 57 becoming less
restrictive.
Mechanical:
M1305.1.1. Furnaces and Air Handlers: The requirement for specific clearances for
equipment installed in closets or compartments was removed.
M1502.4.4 Dryer Exhaust Duct Power Ventilators: Now recognized in the IRC.
M1502.4.5.3: The length of power ventilator duct is determined by the manufacturer.
M1502.4.6: A label is required when the exhaust duct exceeds 35 feet in length.
M1503.6 Range Hoods: Now only requires makeup air when natural draft gas appliances
are present.
Fuel Gas:
G2404.11 Condensate Pumps: Pumps located in uninhabitable spaces must be
connected to equipment in such a way the equipment turns off if the pump fails.
Table G2413.2 Approximate Gas Input for Typical Appliances: This was removed.
G2414.4.2 Steel: Steel pipe is now allowed to be used for fuel-gas piping.
G2414.6 Plastic Pipe: PVC and CPVC pipe is not permitted for use as gas piping.
G2415.7.1 Piping Through Bored Holes or Notches: Protection must extend four inches
on both sides of a stud wherever protection is required. There is an exception for steel
piping.
G2427.4.1 Plastic Piping: This is only allowed when it is approved the venting when the
appliance is listed for its use.
Plumbing:
P2503.7 Water Supply System Testing: An exception was added so PEX piping can be air
tested
P2603.2.1 Protection Against Physical Damage: The minimum distance concealed piping
can be to the face of a stud without protection was reduced.
P2713.1 Bathtub Overflows: Would no longer be required.
P2801.6 Required Pan: These can now be plastic.
P2903.5 Water Hammer: This was added back to the IRC and they allow for quick closing
valves.
Some new sections added to plumbing will probably be removed from the Gilbert Code
as they are monitored by Maricopa County.
P3010 and P3011.1 Trenchless Sewer Replacement: This is new technology for
replacement of sewers and piping.
P3103.1.3 – Vent Terminals: Plumbing vents can be terminated at two inches instead of
the current six inches of they are covered.
Electrical:
E3702.13 Electric Vehicle Branch Circuit: This must be a dedicated circuit for vehicle
charging stations and it cannot supply other outlets.
E3703.5 Garage Branch Circuits: There must be one dedicated 20 amp circuit for the
garage.
E3901.9 Garage Receptacles: A receptacle is now required in each car bay.
E3901.2 Wall Space: Cabinets with counter tops are considered wall space when spacing
electrical outlets.
E3901.4.3 Peninsular Countertop Space: The required outlet spacing is now measured
from the perpendicular wall.
E3902.8 Ground-Fault Circuit Interrupter (GFCI) in Bathrooms: GFCI is required within six
feet of bathtubs and showers.
E3902.9 Laundry Areas: All receptacles in laundry areas must be GFCI protected.
E3902.10 Kitchen Dishwasher Branch-Circuit: GFCI protection required.
E3902.16 Arc-Fault Circuit Interrupter (AFCI) Protection: Kitchen and laundry rooms now
require AFCI protection.
E4002.9 Wet Locations: Outlet box hoods have to be extra duty which the exception for
locations where a pressure washer routinely used.
Appendices are not part of code unless they are specifically adopted
There is an Appendix A regarding Tiny houses. This section relaxes a lot of the IRC codes.
Many times these homes are built somewhere else and moved to a different location.
They would not be subject to Gilbert Building Codes.
4. Discussion of next steps.
Chair Taylor said many of the comments received on the website repeats. He asked if
the form should be closed. If anyone has any comments they can email members of the
subcommittee. Development Services Director Mieras said the department has been
active in contacting interested parties.
Plan Review and Inspection Manager Taylor noted changes in IRC and application of
those codes are two different issues. He said he thought about removing the sections
that do not pertain to this region but it would not make the Town’s Building Code any
smaller as there would be more amendments about disregarding different sections.
Councilmember Anderson said he thinks some builders believe the Town only uses what
is found in the amendments. They think if the entire IRC is adopted the Town will go
through the IRC trying to find things wrong with buildings. Plan Review and Inspection
Manager Taylor said that may be been true many years ago but it is not true today.
The next meeting will be March 6, 2019 at 4:00 p.m.
ADJOURN
Chair Taylor adjourned the meeting at 5:17 p.m.
ATTEST:
___________________________ ___________________________________
Chair Jared Taylor Lisa Maxwell, MMC, Town Clerk
Agenda
Subcommittee on Building Codes
2/6/2019 4:30:00 PM
Municipal Center II, Room 100
Gilbert, Arizona
MEMBERS MAY ATTEND IN PERSON OR BY TELEPHONE
CALL TO ORDER
AGENDA ITEMS
1. Approval of the minutes of the January 15, 2019 meeting.
2. Report on presenation to the Gilbert Chamber of Commerce.
3. Presentation of significant changes to the 2018 Building Codes.
4. Discussion of next steps.