Planning Commission
Regular MeetingMinot, ND · August 26, 2019
Minutes
PLANNING COMMISSION MINUTES
Regular Meeting
August 26, 2019
Page 1 of 11
Regular Meeting: Planning Commission
Location: City Hall, Council Chambers, 515 2nd Avenue SW, City of Minot, ND
Meeting Called to Order: Monday, August 26, 2019 at 5:30 p.m.
Presiding Official: Chairman, Jon Hanson
Members in Attendance: Baumann, Bullinger, DeMakis, Hanson, Hochhalter, Koop, Larshus,
Sivertson (Commissioner Barnett joined the meeting after Approval of Minutes)
Members Absent: Bartsch, Keller, Offerdahl, Wegenast
City Staff Present: Brian Billingsley (Community & Economic Development), Lance Lang
(Principal Planner), Kelly Hendershot (City Attorney), Lance Meyer (City Engineer), Alderman
Podrygula, Officer Wheeler, Kelli Kronschnabel (Fire Chief), Jess Sinerius (Minot Rural Fire
Department), Glenda Sorensen (Planning Assistant)
Others Present: Rianne Kuhn & Megan Laudenschlager (Visit Minot), Jason Cullen & Ken
Burndt (Ferrellgas), Todd Berning (Epic), Karen Jensen
Meeting Called to Order by Chairman Jon Hanson
Approval of the July 29, 2019 Regular Meeting Minutes.
Motion by Commissioner DeMakis to approve without edits, second by Commissioner Koop,
and was carried by the following roll call vote: ayes: Baumann, Bullinger, DeMakis, Hanson,
Hochhalter, Koop, Larshus, Sivertson, nays: none
Motion carries
The following are the recommendations of the Planning Commission:
Item #1:
It is recommended the City Council adopt a resolution approving a request by Ferrellgas, L.P.
for a Conditional Use Permit to construct a propane storage and distribution facility on a site
replacing an existing industrial use. This property is located at 1001 46th Avenue, NE.
Finding of Facts:
1|Page
PLANNING COMMISSION MINUTES
Regular Meeting
August 26, 2019
Page 2 of 11
1. A natural gas company had been looking for a site to establish a storage and
distribution facility in the Minot area. The former site was compromised during the
2011 flood.
2. The applicant found two (2) parcels next to one another that have good
transportation access and are commercially zoned.
3. The two sites selected are zoned C2, General Commercial which requires a
Conditional Use Permit (CUP) for “storage or handling of hazardous materials.” A
separate CUP is required for each parcel unless they are combined. The applicant
chose not to combine them.
4. The applicant has applied for a CUP for each lot and submitted all required materials
including a Site Plan.
5. Commercial development standards apply to C2 zones.
Staff Recommendations and Conditions:
Staff recommends approval of this Conditional Use Permit subject to the following conditions:
1) Storm Water Management Plan is required.
2) Site shall meet C2 requirements for number of parking spaces, curbing and hard surface
parking area, and hard surface storage area with screening.
3) No additional access points on 46th Ave NE will be allowed.
4) This project must comply with commercial landscaping requirements for C2 zoning.
a. Street trees are required for the length of frontage along 46th Avenue NE in a ten
(10) foot wide strip of grass abutting the public right-of-way. Said trees shall be
a minimum size of 1 ½-inch caliper and shall be deciduous canopy or ornamental
trees. The quantity of trees shall be determined by dividing the length of
frontage by fifty (50) resulting in one (1) tree per each fifty (50) lineal feet of
frontage. The trees need not be spaced exactly fifty feet apart. The trees can be
grouped, evenly spaced, staggered, etc. as long as the size and quantity
requirements are met.
b. Street tree requirements along the frontage of 10th Street NE right-of-way are
waived to a later date to coincide with future construction of the street.
c. Interior parking lot landscaping is required for the customer/employee parking
lot.
d. Parking lot landscaping is not required for ancillary truck parking north of the
building or outdoor storage areas.
e. Foundation plantings are required along the front façade facing 46 Avenue NE.
Chairman Hanson asked the Principal Planner for staff comments. Principal Planner Lance Lang
stated that this property and the adjacent lot to the east will both be developed to
accommodate this propane facility, assuming the CUP’s are approved. CUP’s are tied to the
land, so two separate CUP’s are required in this case, one for this parcel and one for the east
parcel which is item # 2 on the agenda.
2|Page
PLANNING COMMISSION MINUTES
Regular Meeting
August 26, 2019
Page 3 of 11
These properties are zoned C2, General Commercial. There has been an oil field service
company operating from this property in recent years. The use type; “Sales, rental or storage
of oil and gas well drilling equipment is not an allowable use in this zoning district. It is an
industrial use, not a commercial use. The site should be developed to commercial standards,
but it is not. Not sure how this was allowed to happen? The good news is that the proposed
propane facility does fit in C2 zoning as a conditional use, hence the requirement for the CUP’s.
The use type is defined as “storage and handling of hazardous materials.”
Principal Planner Lang continued, stating that the proposed facility will need to meet
commercial development standards such as paving, stormwater management, and landscaping.
These concerns were summarized and are listed in the conditions required for each permit.
Chairman Hanson opened up comments from the commissioners.
Chairman Bauman asked Principal Planner Lang what he foresees for that corner of the city.
Lang stated that he cannot answer with confidence as there are too many unknowns. This area
is on the fringe of development and located along the north by-pass. The pace of development
across the community has been slow in recent times, and developers determine the type,
location and timing of development ultimately. The future land use map shows large areas of
“Business Park/Office” and “Medium Density Residential” which may be a stretch.
“Neighborhood Commercial is depicted at the intersection of 46th Avenue to the east which
makes some sense transitioning down from more intensive general commercial to local
commercial. The higher density residential is questionable, there may be some, but the area is
more likely to be predominantly lower density single-family and rural residential. Overriding
large-scale planning concerns like these will be addressed with the next update to the
comprehensive development plan.
Chairman Hanson asked Jason Cullen, representing Ferrellgas LLC, if he was accepting of the
noted conditions, and Mr. Cullen confirmed that they are.
Chairman Hanson opened up comments from the public.
Mr. Cullen gave a background summary of the company and the project. He cited three (3)
main points:
1. Ferrellgas are good neighbors for the city.
2. Ferrellgas helped to handle the Trinity gas explosion.
3. Ferrellgas has two (2) existing locations that will be closing and all facilities will be
relocating to the subject sites.
Motion by Commissioner Koop to approve based on the terms & conditions and findings of fact,
second by Commissioner Hochhalter, and was carried by the following roll call vote: ayes:
3|Page
PLANNING COMMISSION MINUTES
Regular Meeting
August 26, 2019
Page 4 of 11
Barnett, Baumann, DeMakis, Hanson, Hochhalter, Koop, Larshus, Sivertson, nays: none,
abstained: Bullinger.
Motion carries
Item #2
It is recommended the City Council adopt a resolution approving a request by Ferrellgas, L.P.
for a Conditional Use Permit to construct a propane storage and distribution facility on
undeveloped property. This property is located at 1011 46th Avenue, N.E. (adjacent to
property listed above).
Finding of Facts:
1. A natural gas company had been looking for a site to establish a storage and
distribution facility in the Minot area. The former site was compromised during the
2011 flood.
2. The applicant found two (2) parcels next to one another that have good
transportation access and are commercially zoned.
3. The two sites selected are zoned C2, General Commercial which requires a
Conditional Use Permit (CUP) for “storage or handling of hazardous materials.” A
separate CUP is required for each parcel unless they are combined. The applicant
chose not to combine them.
4. The applicant has applied for a CUP for both parcels and submitted all required
materials including a Site Plan.
5. Commercial development standards apply to this site as with any other commercial
site.
Staff Recommendations and Conditions:
Staff recommends approval of this Conditional Use Permit subject to the following conditions:
1) Storm Water Management Plan is required.
2) No additional access points on 46th Ave NE will be allowed.
3) All ancillary parking and outdoor storage areas to be hard-surfaced with portland
cement concrete or asphaltic concrete.
4) Street trees are required for the length of frontage along 46th Avenue NE in a ten (10)
foot wide strip of grass abutting the public right-of-way. Said trees shall be a minimum
size of 1 ½-inch caliper and shall be deciduous canopy or ornamental trees. The
quantity of trees shall be determined by dividing the length of frontage by fifty (50)
resulting in one (1) tree per each fifty (50) lineal feet of frontage. The trees need not be
spaced exactly fifty feet apart. The trees can be grouped, evenly spaced, staggered, etc.
as long as the size and quantity requirements are met.
5) A landscaped buffer yard is required along the east property line. The buffer yard
shall be twenty (20) feet in width, planted to grass with one (1) tree for each
4|Page
PLANNING COMMISSION MINUTES
Regular Meeting
August 26, 2019
Page 5 of 11
twenty (20) lineal feet of buffer yard. The trees shall be at least fifty percent (50%)
conifers (evergreens) at least five (5) feet in height, not including the container or
root ball. The remaining trees can also be conifers, or deciduous or ornamental
trees can be used to fulfill this requirement, 1 ½-inch caliper minimum size. The
buffer yard shall not be paved or rocked, shall not be used for parking or outdoor
storage of equipment or materials.
Chairman Hanson requested staff comments.
Principal Planner Lang said this CUP request is basically the other half of the project. The
conditions of approval are somewhat different for each one.
Chairman Hanson opened up comments from the commissioners. None were presented.
Chairman Hanson opened up comments from the public.
Jason Cullen, representative for Ferrellgas, came forward to clarify that this eastern area of
the site will only hold “dead steel” storage, which means propane tanks will not be
pressurized. The only pressurized tanks will be the two 30,000 gallon tanks to the west
with the first CUP.
Motion by Commissioner DeMakis to approve based on the terms & conditions and findings of
fact, second by Commissioner Koop, and was carried by the following roll call vote: ayes:
Barnett, Baumann, DeMakis, Hanson, Hochhalter, Koop, Larshus, Sivertson, nays: none,
abstained: Bullinger.
Motion carries
Item #3
It is recommended the City Council adopt a resolution to approve a request by Blu on
Broadway, LLC for consideration of a Planned Unit Development (PUD) submittal for a mixed-
use project containing commercial uses on the ground floor and affordable housing on upper
floors, to consider an increase in proposed density and also deviations to landscaping and
parking requirements. This property is located at 1629 S. Broadway.
Finding of Facts:
1. The applicant approached the City with a mixed-use commercial/residential building as
a qualifying project for an infill affordable housing project for 100% Low and Moderate
Income persons for some of the CDBG-NDR grant money available from the City.
5|Page
PLANNING COMMISSION MINUTES
Regular Meeting
August 26, 2019
Page 6 of 11
2. The proposed project does not meet some of the standard development criteria
required in the zoning ordinance:
a) The density of the proposed project exceeds the maximum allowable density
in this zoning district.
b) The number of off-street parking stalls proposed falls short of the number
required by code.
c) There is not sufficient space on the site left over to meet some of the
landscaping requirements once the building, parking, and other site
improvements are accounted for.
3. The applicant has applied for a Planned Unit Development Overlay over the C2 base
zone to request deviations from the strict interpretation of the ordinance be allowed so
that this project may be approved as presented.
Staff Recommendations & Conditions:
Staff recommends approval of the PUD application subject to the following conditions:
1. Storm Water Management Plan required.
2. Developer’s Agreement required.
3. Developer required to improve 1st St SW to serve this project.
a. Install water main in 1st St SW.
b. Reconstruct 1st St SW – including sidewalk and lighting.
c. Additional details will be provided in the Developer’s Agreement.
4. Traffic impact study – eliminate access to Broadway.
5. New fire service required.
6. Sewer connection fees required.
7. Additional addresses will be assigned to each leasable space with its own exterior door.
8. Approval of this PUD authorizes a reduction in off-street parking to 80 parking spaces
from that quantity otherwise required by the Minot zoning ordinance.
9. Approval of this PUD authorizes an increase in allowable density to 30 living units per
acre, well above the maximum that is otherwise enforced in C2 zoning districts.
10. Approval of this PUD and the associated concept Landscape Plan established intent, and
authorizes some deviations in landscaping requirements as it allows the applicant to
work with City staff and the Minot Park District in developing final plans for recreational
amenities and landscaping that will be public amenities.
11. In the event of future problems with inadequate off-street parking for the residents, the
City Council may require a certain quantity of the total parking spaces they deem
reasonable to be signed as “Reserved for Residential Tenants Only.”
12. A minimum of 3,000 square feet of office space shall be provided on the ground floor.
Chairman Hanson requested comments from City staff.
6|Page
PLANNING COMMISSION MINUTES
Regular Meeting
August 26, 2019
Page 7 of 11
Principal Planner Lance Lang described the proposed project as an infill development at the site of the old
Pepsi Bottling Plant on South Broadway between 16th and 17th Street SW. The proposed project is a five (5)
story mixed-use building with commercial retail/office on the ground floor and four stories of residential
apartments above. The apartments will be one hundred percent (100%) restricted to persons that meet low
and moderate income (LMI) thresholds. There is also an underground parking garage for a limited number
of vehicles. The developer is seeking approval from the City to leverage financing of up to $4,750,000 in
CDBG-NDR funds for LMI Housing which will be guaranteed by a forgivable loan. There is
approximately 8,800 square feet of proposed retail/office on the main floor with forty-two (42) living units
for qualified LMI tenants above.
For a mixed-use project such as this, Chapter 11 of the Minot Zoning Ordinance states the
following under Section 11-3, Permitted Uses, paragraph q):
“Residential units (renter or owner occupied) use on the same lot and mixed in the same building
with the residential use located in the floor(s) above the commercial use. All off-street parking
and loading requirements are met for both uses (emphasis added). The height, area, and yard
exceptions of the C2 district must also be met. Any residential units cannot exceed RM
densities.” (emphasis added)
Lang stated that the proposed development exceeds the allowable density and falls short on the
number of required off-street parking spaces. The developer and City staff agreed the best
approach to present the project with the requested deviations is the Planned Unit Development
approach. Although this project is not a large acreage typically associated with a PUD proposal,
such as the recently approved Southwest Crossing PUD, nevertheless this proposal does contain
a mix of commercial retail, office and affordable residential uses.
DENSITY. The maximum density allowed in RM, Medium-Density Residential is sixteen (16)
units per acre. With forty-two (42) residential units proposed on 1.40 acres the proposed density
of this project is thirty (30) units per acre, almost twice the listed maximum density of sixteen
units per acre.
PARKING. The applicant is providing 80 off-street parking stalls, 53 less than the minimum
required by strict application of Chapter 23, Off-Street Parking Regulations in the zoning
ordinance. This due to the fact that the ordinance requirement for apartments is two (2) stalls per
dwelling unit plus .25 stalls for visitor parking. The developer has requested reduction to one (1)
stall per unit with no additional parking for visitors. The developer justified the reduction in
residential parking on the fact that the proposed apartments are 100% reserved for qualified
low/moderate income persons, many of which may not have a car, or if they do, it is unlikely the
parking ratio will exceed one car per unit.
The gap between required and proposed parking is substantial, however staff is in agreement that
the LMI factor reduces the parking demand when compared to market rate apartments. There are
five (5) studio apartments and twenty-seven (27) one bedroom apartments out of the 42 total
units. The studio and one-bedrrom tenants will likely have only one car. There are only ten (10)
7|Page
PLANNING COMMISSION MINUTES
Regular Meeting
August 26, 2019
Page 8 of 11
two-bedroom apartmants out of the 42 total units. There is no leftover space on the site available
for additional parking. If the residential density is deemed to be too high when compared to the
available parking, the only solution is to lower the density and then the project may not qualify
for the financial incentives the developer is seeking.
Staff also required a fixed percentage of the ground floor space be marketed for office use as
opposed to retail because offices have a lower parking demand. The developer has committed to
a minimum of 3,000 square feet of office space on the ground floor.
Staff has agreed that the seven (7) stalls in the proposed drive thru que can also be counted
towards off-street parking.
LANDSCAPING, OPEN SPACE & AMENITIES. The development concept features an outdoor
recreation space. As with the recent Southwest Crossing PUD the exact components and layout
are not fully determined at this point as the developer is working with Minot Park District and
City Staff to determine what type of recreational amenities are most needed in this area. The
final product will be a public amenity that anyone in the community can use as opposed to an
amenity package strictly for the tenants and customers. A Landscape Plan is provided that
establishes a strong baseline for the landscapng of the site. As the project is further developed
the details of the landscaping will be finalized.
Chairman Hanson opened up comments from the commissioners.
Commissioner Hanson noted that density is necessary for grant money.
Commissioner Baumann thanked the applicant for their work and stated that he appreciates
that the project approach represented in the proposal is not reliant on cars to access local sites
in the area.
Commissioner Larshus asked about the green space in the back and what the advantage was.
Larshus also noted that this type of area is usually capped for the residents. Mr. Berning replied
that there would be no monitoring of the green space and that it is open to the public.
Commissioner Hanson opened up comments from the public.
Todd Berning of Epic Properties, the lead developer for the project, cited the following:
This project scored high within HUD sustainablilty metrics, primarily due to its location.
Epic specializes in urban development.
The exterior will be aesthetically pleasing. Brick, decorative block, pre-cast concrete,
EIFS, glass and steel will be used.
When completed, Epic believes that this will be the nicest LMI building in the state.
8|Page
PLANNING COMMISSION MINUTES
Regular Meeting
August 26, 2019
Page 9 of 11
Karen Jensen came forward to state that she owns property adjacent to this site. She has no
objections to the project, but is concerned about the overflow parking and agrees with Principal
Planner’s assessment that more parking is needed.
Commissioner Baumann stated that there is concern in the city for parking and asked if there
would be room to modify. Principal Planner Lance Lang stated that this site is tight and there is
no alternative or additional space available for parking. However, the Zoning Ordinance
Advisory Committee will be looking at potential revisions to the off-street parking chapter in
the near future.
Motion by Commissioner Koop to approve based on the terms & conditions and findings of fact,
second by Commissioner Baumann, and was carried by the following roll call vote: ayes:
Barnett, Baumann, Bullinger, DeMakis, Hanson, Hochhalter, Koop, Larshus, Sivertson, nays:
none.
Motion carries
Item #4
It is recommended the City Council pass an ordinance amending Chapter 2, Definitions and
section 11-3(q) of Chapter 11 of the Zoning Supplement to the Code of Ordinances, City of
Minot, North Dakota to regulate commercial and residential mixed use in hotels and motels
in the C2, General Commercial Zoning District.
Finding of Facts:
1. In recent months some hotels and motels have been emphasizing long-term stays as
opposed to accommodations for typical overnight travelers by using the commercially
zoned properties for what equates to residential apartments.
2. This trend is problematic because:
a. It violates zoning regulations.
b. The facilities were not built to be apartments.
c. There are no staff present.
d. Required exits are often locked or obstructed.
e. The owners are not paying lodging tax.
3. In some cases, lodging establishments offer residential quarters for employees to be on-
site full time. The intent of the ordinance amendments is not to restrict this activity.
4. Language in the definitions chapter has been added to clarify that on-site residential
quarters are permitted for employees. The C2 chapter of the zoning ordinance allows
upper floor residential use if the ground floor is a commercial use which creates an
unintended “loophole” allowing overnight lodging and motel operations on the ground
floor with extend stay apartments above. This option will no longer be allowed unless
9|Page
PLANNING COMMISSION MINUTES
Regular Meeting
August 26, 2019
Page 10 of 11
the motel operator seeks approval of the mixed-use facility as a Planned Unit
Development.
5. Staff has drafted text amendments to address these issues.
Staff Recommendations and Conditions
Staff recommends approval of the proposed ordinance amendments as presented.
Chairman Hanson asked for a staff report.
Principal Planner Lance Lang said staff and the Zoning Ordinance Advisory Committee have
been working on these amendments for the past couple of months with input for several
interest groups. In the last few months there has been media coverage regarding these issues.
Staff felt that the language in C2 zoning permitting residential apartments above retail space on
the ground floor was a potential “loop hole” whereby lodging owners could rent the ground
floor unit for nightly stays as a retail business and the upper floor for long term stays as
apartments. That is not the intent of this section of the code.
Some of the lodging facilities in Minot have been offering long term leases paramount to
apartment use which is causing several concerns. This trend is problematic because:
a. It violates zoning regulations. Residential (apartments included) uses are not
allowed in commercial zones.
b. The lodging facilities were not built to be apartments, and not built to
accommodate long term stays with kitchen facilities for example. Renters then
bring microwaves, hot plates, dorm fridges etc.
c. There are no staff present, no front lobby.
d. Required exits are often locked or obstructed which causes a life safety concern.
e. The Visitors Bureau is concerned about the image these places may project to
visitors staying in Minot
f. The owners are not paying lodging tax.
Chairman Hanson opened up comments from the commissioners. There were none.
Chairman Hanson opened up comments from the public.
Megan Laudenschlager came forward and stated that she has been working with the City and is
in favor of closing the loophole for a better visitor experience. She also thanked the city for
their attention to the issue. Her two primary concerns are health and safety issues and the
potential for a negative visitor experience.
10 | P a g e
PLANNING COMMISSION MINUTES
Regular Meeting
August 26, 2019
Page 11 of 11
Motion by Commissioner DeMakis to approve based on the staff recommendation and findings
of fact, second by Commissioner Larshus, and was carried by the following roll call vote: ayes:
Barnett, Baumann, Bullinger, DeMakis, Hanson, Hochhalter, Koop, Larshus, Sivertson, nays:
none.
Motion carries
Other Business
Free training for Planning Commissioners at the upcoming North Dakota Planners Association
Annual Conference in Bismarck, Thursday, September 19 from 3:50 to 6:00 PM at the end of
the conference. This training is free, if anyone wants to attend other sessions during the
conference they need to register on-line at https://www.ndplanning.org/conference. The
conference will be held at the Bismarck Event Center, 315 S 5th Street. We need to RSVP
numbers, so if you plan to attend please let Glenda know.
Principal Planner Lang thanked Planning Commission Chairman Hanson for his service to the
city. This was greeted by a well-deserved round of applause. As previously nominated and
elected, Commissioner Charles DeMakis will take over as Chairman at the September 2019
meeting.
With no other business before the committee, Chairman Hanson adjourned the meeting at
6:32.
Minutes prepared by: Glenda Sorensen & Lance Lang
11 | P a g e
Get email alerts for Minot
A daily email when new agendas and minutes are posted.