Board of Zoning Appeals
Regular MeetingMurfreesboro, TN · July 27, 2016
Agenda
CITY OF MURFREESBORO
BOARD OF ZONING APPEALS
Regular Meeting, July 27, 2016, at 1:00 p.m.
City Hall, 111 West Vine Street, Council Chambers, 1st Floor
AGENDA (REVISED 7/19/16)
1. Call to order
2. New Business
Sign Variance Request
a. Application S-16-046 by Ian Phillips of Everwood at the Avenue LLC,
requesting a Variance from Section 25¼-24(A)(22) of the Murfreesboro Sign
Ordinance, which prohibits a sign from being placed in or over a public utility
or drainage easement, for property in the Mixed Use (MU) district located at
915 Robert Rose Drive.
Variance Requests
b. Application Z-16-047 by Sean Guth of Lose and Associates Inc.,
representing the Murfreesboro Parks and Recreation Department,
requesting a forty (40) foot Variance from Section 18(G)(4) of the
Murfreesboro Zoning Ordinance, which prohibits lighting fixtures from
exceeding twenty (20) feet in height in nonresidential developments with
structures thirty-five (35) feet or less in height, for property in the Park (P)
district located at 1007 Golf Lane.
c. Application Z-16-048 by Sean Guth of Lose and Associates Inc.,
representing the Murfreesboro Parks and Recreation Department,
requesting the following two Variances for property in the Park (P) district
located at 515 Cherry Lane:
i. A seventy (70) foot Variance from Section 18(G)(4) of the
Murfreesboro Zoning Ordinance, which prohibits lighting fixtures from
exceeding twenty (20) feet in height in nonresidential developments
with structures thirty-five (35) feet or less in height; and
1
ii. A Variance from Section 18(G)(d) of the Murfreesboro Zoning
Ordinance, which requires outdoor lighting to be designed such that
illumination does not exceed one-half (0.5) footcandle beyond the
property line.
d. Application Z-16-049 by Clyde Rountree of Huddleston Steele
Engineering Inc. representing Deep River Development, requesting a nine
(9) foot Variance from Chart 2 (Minimum Lot Requirements, Minimum Yard
Requirements, and Land Use Intensity Ratios) of the Murfreesboro Zoning
Ordinance, which requires a twenty-five (25) foot minimum rear yard setback,
for property in the Multi-Family Residential (RM-16) district located at 1019
North Maple Street.
Variance and Special Use Permit Request
e. Application Z-16-050 by David Beiter of Goodwill Industries, making the
following requests for property in the Highway Commercial (CH) district
located at 1825 Old Fort Parkway:
i. A Special Use Permit to allow a Temporary Mobile Recycling Center
in the CH district; and
ii. An eight (8) foot Variance from Section 31(C)(1) of the Murfreesboro
Zoning Ordinance, which limits the length of Temporary Mobile
Recycling Center receptacles to forty (40) feet.
f. Application Z-16-051 by David Beiter of Goodwill Industries, making the
following requests for property in the Highway Commercial (CH) district
located at 1114 Mercury Boulevard:
i. A Special Use Permit to allow a Temporary Mobile Recycling Center
in the CH district;
ii. An eight (8) foot Variance from Section 31(C)(1) of the Murfreesboro
Zoning Ordinance, which limits the length of Temporary Mobile
Recycling Center receptacles to forty (40) feet; and
iii. A 175-foot Variance from Section 31(C)(6) of the Murfreesboro
Zoning Ordinance, which requires a 300-foot minimum distance
between receptacle and residentially-zoned property.
g. Application Z-16-052 by Clyde Rountree of Huddleston Steele
Engineering Inc., representing Mountain Star Properties LLC, making the
following requests for property in the Highway Commercial (CH) district
located along the east side of John R. Rice Boulevard:
i. A Special Use Permit to allow a Self-Service Storage Facility in the CH
district; and
2
ii. A Variance from Section 27(K)(3)(a) of the Murfreesboro Zoning
Ordinance, which requires a three (3) foot minimum landscape strip
adjacent to the base of a building along the building’s sides.
3. Staff Reports and Other Business
4. Adjourn
3
MURFREESBORO BOARD OF ZONING APPEALS
STAFF REPORT
JULY 27, 2016
Application: S-16-046
Location: 915 Robert Rose Drive
Applicant: Ian Phillips of Everwood at the Avenue LLC
Zoning: Mixed Use (MU) District
Request: A Variance from Section 25¼-24 (A)(22) of the Murfreesboro Sign
Ordinance, which prohibits a sign placed in or over a public utility or
drainage easement
1
The applicant, Ian Phillips with CIP Construction Company representing Everwood at the
Avenue, is requesting a variance from Section 25 ¼-24 (A)(22) of the City of Murfreesboro Sign
Ordinance which prohibits a foundation or signs placed in or over a public utility or drainage
easement without consent of the easement holder and Board of Zoning Appeals approval. The
sign location proposed at 915 Robert Rose Dr. is within a Gateway Design Overlay (GDO-1)
zone.
The applicant is requesting permission to erect one (1) internally illuminated freestanding wall
sign with 38 sq. ft. display area and an overall height of 7’. The sign will be located within a 40’
Public Utility Easement.
The Agreement for a Sign in a City of Murfreesboro Easement has been signed by the
Murfreesboro Electric Dept (MED), Murfreesboro Water and Sewer Department (MWSD), the
Director of Building and Codes and the City Engineer. An agreement for a sign in an easement
letter has also been submitted from AT&T and Atmos Energy with no objections to the sign
placement. Consolidated Utility District (CUD) submitted an agreement for the sign to be
installed in the easement with the requirement of a 10’ minimum separation from waterlines.
Due to the sensitivity of placement of the sign in regards to easements, staff requires that the sign
be located on site by a Tennessee registered engineer or surveyor and that a form for
Certification of sign placement be provided prior to permitting.
The applicant will comply with all other setbacks and regulations.
2
3
4
5
6
7
8
9
10
11
12
MURFREESBORO BOARD OF ZONING APPEALS
STAFF REPORT
JULY 27, 2016
Application: Z-16-047
Location: 1007 Golf Lane
Applicant: Sean Guth of Lose and Associates Inc., representing the Murfreesboro Parks
and Recreation Department
Zoning: Park (P) District
Request: A forty (40) foot Variance from Section 18(G)(4) of the Murfreesboro Zoning
Ordinance, which prohibits lighting fixtures from exceeding twenty (20) feet
in height in nonresidential developments with structures thirty-five (35) feet
or less in height
1
Request Overview
The Murfreesboro Parks and Recreation Department wishes to install new lighting fixtures to
illuminate eight tennis courts at Old Fort Park, located at 1007 Golf Lane. The subject property
lies within the Park (P) zoning district. The affected courts are identified as courts 5, 6, 9, 10,
and 13-16 on the attached site electrical plan.
The applicant plans to install a total of 16 new lighting poles, which will allow the eight affected
tennis courts to be illuminated during evening hours. The lighting poles range from 50 feet to 60
feet in height; these heights exceed the maximum height of 20 feet allowed by Section 18(G)(4)
of the Murfreesboro Zoning Ordinance. The applicant requests that the Board vary the 20-foot
maximum lighting height requirement by 40 feet to allow the installation of 16 lighting poles
ranging from 50 to 60 feet in height.
Relevant Zoning Ordinance Section
Section 18(G)(4):
On-site lighting fixtures in residential developments shall not exceed sixteen feet in height.
For nonresidential developments with structures thirty-five feet or less in height, fixtures
shall not exceed twenty feet in height. For nonresidential developments with structures
greater than thirty-five feet in height, fixtures shall not exceed a height of thirty feet.
Shoebox-style lighting fixtures shall not be used for poles of sixteen feet or less in height.
In areas zoned H-I (Heavy Industrial) or L-I (Light Industrial) to be developed with large
parking lots that will occasion maneuvering areas for large trucks, lighting poles and
fixtures may be a maximum height of 75 feet.
Staff Comments
The applicant’s request letter addresses each of the three standards for granting a Variance.
First, the applicant attests that the lighting height restriction imposed by the Zoning Ordinance
poses a practical difficulty for this project. The applicant contends that for a field to be properly
lighted, poles must exceed the 20-foot maximum height; further, poles must be physically
situated in such a way that they do not interfere with players’ sightlines. Second, the applicant
indicates that the very nature of Old Fort Park—an active park with multiple recreation facilities
that include lighting poles exceeding Zoning Ordinance height maximums—creates unusual
characteristics when compared to other properties in the City. Third, the applicant attests that
this situation is not self-created. Planning staff visited Old Fort Park and noted the presence of
several lighting poles that exceeded 20 feet.
Staff is unaware of any complaints from neighboring residents or motorists regarding existing
lighting pole heights. Based on a site visit and review of aerial photography, it appears that no
residential properties would be affected by the proposed lighting. The tennis courts are interior
2
to Old Fort Park. The nearest neighboring property to the tennis courts is Stones River Mall,
approximately 1,100 feet to the west.
Representatives of the Franklin Parks and Recreation Department will be in attendance at the
meeting to discuss the project and answer any questions the Board may have.
Attached Exhibits
1. BZA Application
2. Applicant’s Request Letter
3. Site Photographs
4. Applicant’s Supporting Materials
3
4
5
1007 Golf Lane
Aerial Photographs
Aerial photograph of 1007 Golf Lane. The affected tennis courts lie internal to Old Fort Park.
6
Aerial photograph of 1007 Golf Lane. The southernmost four tennis courts are not included in the
Variance request.
7
8
9
10
11
MURFREESBORO BOARD OF ZONING APPEALS
STAFF REPORT
JULY 27, 2016
Application: Z-16-048
Location: 515 Cherry Lane
Applicant: Sean Guth of Lose and Associates Inc., representing the Murfreesboro Parks
and Recreation Department
Zoning: Park (P) District
Requests: 1) A seventy (70) foot Variance from Section 18(G)(4) of the Murfreesboro
Zoning Ordinance, which prohibits lighting fixtures from exceeding
twenty (20) feet in height in nonresidential developments with structures
thirty-five (35) feet or less in height, and
2) A Variance from Section 18(G)(d) of the Murfreesboro Zoning
Ordinance, which requires outdoor lighting to be designed such that
illumination does not exceed one-half (0.5) footcandle beyond the
property line.
1
Request Overview
The Murfreesboro Parks and Recreation Department wishes to install new lighting fixtures to
illuminate four recreation fields at Richard Siegel Park, located at 515 Cherry Lane. The subject
property lies within the Park (P) zoning district.
The applicant plans to install a total of 16 new lighting poles, which will allow the recreation
fields to be illuminated during evening hours. The lighting poles range from 70 feet to 90 feet in
height; these heights exceed the maximum height of 20 feet allowed by Section 18(G)(4) of the
Murfreesboro Zoning Ordinance.
Additionally, the photometric plot submitted by the applicant indicates that the proposed lighting
would generate illumination levels of up to 2.1 footcandles along the western property boundary.
Section 18(G)(d) of the Murfreesboro Zoning Ordinance restricts illumination levels to 0.5
footcandle at all property lines.
The applicant seeks two Variances from the Board. The first request is to vary the 20-foot
maximum lighting height requirement by 70 feet to allow the installation of 16 lighting poles
ranging from 70 to 90 feet in height. The second request is the vary the 0.5 footcandle maximum
illumination requirement by 1.6 footcandles along the western property line to allow illumination
levels of up to 2.1 footcandles along the western property line as shown on the applicant’s
exhibit.
Relevant Zoning Ordinance Sections
Section 18(G)(4):
On-site lighting fixtures in residential developments shall not exceed sixteen feet in height.
For nonresidential developments with structures thirty-five feet or less in height, fixtures
shall not exceed twenty feet in height. For nonresidential developments with structures
greater than thirty-five feet in height, fixtures shall not exceed a height of thirty feet.
Shoebox-style lighting fixtures shall not be used for poles of sixteen feet or less in height.
In areas zoned H-I (Heavy Industrial) or L-I (Light Industrial) to be developed with large
parking lots that will occasion maneuvering areas for large trucks, lighting poles and
fixtures may be a maximum height of 75 feet.
Section 18(G)(d):
Lighting shall be designed so that illumination does not exceed one-half (1/2) foot candle
beyond the property line. All lighting shall have the intensities and uniformity ratio consistent
with the Lighting Handbook of the Illuminations Engineering Society of North America
(IESNA).
2
Staff Comments
The applicant’s request letter addresses each of the three standards for granting a Variance.
First, the applicant attests that the lighting height and illumination level maximums imposed by
the Zoning Ordinance pose a practical difficulty for this project. The applicant contends that for
a field to be properly lighted, poles must exceed the 20-foot maximum height; further, poles
must be physically situated in such a way that they do not interfere with players’ sightlines.
Second, the applicant indicates that the very nature of Richard Siegel Park—an active park with
multiple recreation fields that include lighting poles exceeding Zoning Ordinance height
maximums—creates unusual characteristics when compared to other properties in the City.
Third, the applicant attests that this situation is not self-created.
Planning staff visited Richard Siegel Park and noted the presence of several lighting poles that
exceeded 20 feet. Staff is unaware of any complaints from neighboring residents or motorists
regarding current lighting pole heights or illumination levels. The proposed lights on the west
side of the soccer complex would be located closer to residential properties than any existing
lights. Staff recommends that the applicant take all necessary steps to ensure that neighboring
residential properties are not inconvenienced by the new lighting or the applicant’s ability to host
nighttime activities. Such steps may include setting a firm ending time for all activities.
Representatives of the Franklin Parks and Recreation Department will be in attendance at the
meeting to discuss the project and answer any questions the Board may have.
Attached Exhibits
1. BZA Application
2. Applicant’s Request Letter
3. Site Photographs
4. Applicant’s Supporting Materials
3
4
5
515 Cherry Lane
Aerial Photographs
Aerial photograph of 515 Cherry Lane. The affected area is located on the west side of Richard Siegel
Park.
6
Aerial photograph of 515 Cherry Lane. The area affected by excess illumination is located along the
western property line, near the left-center of the photograph.
7
8
9
10
11
12
13
MURFREESBORO BOARD OF ZONING APPEALS
STAFF REPORT
JULY 27, 2016
Application: Z-16-049
Location: 1019 North Maple Street
Applicant: Clyde Rountree of Huddleston-Steele Engineering Inc. representing Deep
River Development
Zoning: Multi-Family Residential (RM-16) District
Request: A nine (9) foot Variance from Chart 2 of the Murfreesboro Zoning
Ordinance, which requires a twenty-five (25) foot minimum rear yard setback
in the RM-16 district
1
Request Overview
The applicant, Clyde Rountree of Huddleston-Steele Engineering Inc. representing Deep River
Development, wishes to construct a nine-unit residential development at 1019 North Maple
Street, near the intersection of North Maple Street and West Hembree Street. One structure
housing four of the proposed units would be constructed on the east side of the property. A
second structure housing five of the proposed units would be constructed on the west side of the
property. The property is zoned RM-16. Minimum setbacks for two-story, multiple-family
dwellings in the RM-16 district are 30 feet on the front, 25 feet on the rear, and 20 feet on the
sides. The applicant requests a nine foot Variance from the required 25-foot minimum rear yard
setback for the structure on the west side of the property.
Relevant Zoning Ordinance Section
See Chart 2 of the Zoning Ordinance for minimum setback requirements in the RM-16 district.
Staff Comments
As shown on the attached aerial photograph, the subject property was previously used for a
single-family residence. A vacant house currently sits on the property. The property is situated
to the north of a fenced-in parking lot used by O’Charley’s restaurant, which fronts Memorial
Boulevard. The subject property shares a rear property line with the Koji Express restaurant,
which also fronts Memorial Boulevard. The Koji Express property would appear to be the
property most directly affected by the proposed setback encroachment. The portion of the Koji
Express property that adjoins the subject property is currently used as a parking area. The
proposed setback encroachment would appear to have minimal—if any—effects on residential
properties or public right-of-way.
As shown on the attached exhibit, the northern and western property lines are angled, giving the
property a slightly irregular shape. In the attached request letter, the applicant indicates that the
irregularity of the rear (western) property line in particular poses a practical difficulty for this
development.
The applicant will be in attendance at the meeting to discuss the project and answer any
questions the Board may have.
Attached Exhibits
1. Murfreesboro Zoning Ordinance, Chart 2
2. BZA Application
3. Applicant’s Request Letter
4. Site Photographs
5. Applicant’s Supporting Materials
2
APPENDIX A - CHART 2
Minimum Lot Minimum Yard Land Use
Requirements Requirements5, 17 Intensity Ratios
Maximum Maximum
Maximum Gross Lot
16
Area Width Front Side Rear Height Density2 Maximum Minimum Minimum Coverage
DISTRICT AND USE (Sq. Ft.) (Ft.) (Ft.) (Ft.) (Ft.) (Ft.) (D.U./Acre) F.A.R. L.S.R. O.S.R. (percent)
RM-16 DISTRICT
1. Single-family detached dwellings and
[12]
other uses permitted except 6,000 50 30[1] 5[10] 25 35 7.3 none none none 35
[12]
2. Two-family dwellings 6,000 50 30[1] 5[10] 25 35 14.5 none none none 35
MURFREESBORO CITY CODE
[12]
3. Three-family dwellings 9,000 50 30[1] 5[10] 25 35 14.5 none none none 30
[12]
4. Four-family dwellings 12,000 50 30[1] 5[10] 25 35 14.5 none none none 30
[12] [1] [7]
5. Single-family with zero lot line7 3,000 18 30 10 25 35 14.5 none none none none
6. Multiple-family dwellings FN[9] 50[12] 30[1] FN[3] 25 45
[11]
FN[9] none none none none
RM-22 DISTRICT
1. Single-family detached dwellings and
A-275
[12]
other uses permitted except 5,000 50 30[1] 5[10] 25 35 8.7 none none none 35
[12] [1] [10]
2. Two-family dwellings 5,000 50 30 5 25 35 17.4 none none none 35
[12]
3. Three-family dwellings 7,500 50 30[1] 5[10] 25 35 17.4 none none none 30
[12]
4. Four-family dwellings 10,000 50 30[1] 5[10] 25 35 17.4 none none none 30
[12]
5. Single-family with zero lot line7 2,500 18 30[1] 10[7] 25 35 17.4 none none none none
6. Multiple-family dwellings FN[8] 50[12] 30[1] FN[3] 25 60 FN
[8]
none none none none
RZ DISTRICT
1. Single-family detached and single-family
with zero-lot line attached or detached
3,000 30[12] 30[1] 5 20 35 14.5 0.3 0.48 0.7 none
[12]
2. Other uses permitted 6,000 30 30[1] 10 20 35 none none none none 35
R-MO DISTRICT
[12]
1. Mobile homes 4,000 40 25[1] 10 15 12 10.9 none none none none
3
4
5
6
1019 North Maple Street
Aerial Photographs
Aerial photograph of 1019 North Maple Street. The Koji Express restaurant is visible on the west (left) of
the subject property.
7
Aerial photograph of 1019 North Maple Street. An existing single-family house and accessory structure
are visible in the photograph.
8
9
MURFREESBORO BOARD OF ZONING APPEALS
STAFF REPORT
JULY 27, 2016
Application: Z-16-050
Location: 1825 Old Fort Parkway
Applicant: David Beiter of Goodwill Industries
Zoning: Highway Commercial (CH) District
Requests: 1) A Special Use Permit to allow a Temporary Mobile Recycling Center in
the CH district; and
2) An eight (8) foot Variance from Section 31(C)(1) of the Murfreesboro
Zoning Ordinance, which limits the length of Temporary Mobile
Recycling Center receptacles to forty (40) feet
1
Request Overview
The applicant, David Beiter, seeks both a Special Use Permit and a Variance from the Board.
Chart 1 (Uses Permitted by Zoning District) of the Murfreesboro Zoning Ordinance identifies
Temporary Mobile Recycling Center as a use allowed in the CH zone by Special Use Permit.
Section 31(A) of the Zoning Ordinance places a one-year limitation on the duration of Special
Use Permits granted for this use. Section 31(C)(1) of the Zoning Ordinance limits the length of
Temporary Mobile Recycling Center receptacles to 40 feet.
The applicant wishes to continue using a trailer (48 feet in length) for the collection of clothes,
furniture, and miscellaneous household items at the Towne Center Shopping Center at 1825 Old
Fort Parkway. The applicant has obtained permission from shopping center management to
continue operating the trailer. In the attached letter of application, the applicant indicates that the
trailer at 1825 Old Fort Parkway is visited by an average of 79 donors per day.
Relevant Zoning Ordinance Section
Section 31(C)(1):
No receptacle shall exceed forty feet in width.
Staff Comments
With regard to the Special Use Permit, the applicant attests that—with the exception of
receptacle length—the requirements listed in Section 9(C) and Section 31(C) of the Zoning
Ordinance have been satisfied. Specifically, the attached letter of application indicates that the
Temporary Mobile Recycling Center: is reasonably compatible with adjoining properties; has
limited signage; is kept in a clean, safe, and sanitary condition; does not impair traffic flow; is
located at least 300 feet from residential districts; has no processing equipment; and upholds
minimum required setbacks. The Board has previously granted a Special Use Permit to this
applicant for this use; the applicant’s current Special Use Permit expires on July 31, 2015.
With regard to the Variance request, the applicant wishes to continue using a 48-foot trailer,
which exceeds the 40-foot limitation by eight (8) feet. The letter of application indicates that
adhering to the 40-foot trailer limitation when Goodwill Industries employs standard 48-foot
trailers would create a hardship and practical difficulty for the applicant. The Board has
previously granted a Variance to the applicant for a trailer 48 feet in length.
Each request will require a separate motion.
The applicant will be in attendance at the meeting to discuss the project and answer any
questions the Board may have.
2
Recommended Conditions
1) The semi-trailer shall not be located within a driveway aisle.
2) All parts of the semi-trailer shall comply with the minimum 42-foot front setback requirement
of the CH zone.
3) The Special Use Permit shall be valid from August 1, 2016, until July 31, 2017.
Attached Exhibits
1. BZA Application
2. Applicant’s Request Letter
3. Site Photographs
4. Applicant’s Supporting Materials
3
4
5
6
7
1825 Old Fort Parkway, aerial showing trailer location
8
1825 Old Fort Parkway, view from east looking westward (Photo taken by Staff, 7/16/15)
9
10
11
12
13
14
MURFREESBORO BOARD OF ZONING APPEALS
STAFF REPORT
JULY 27, 2016
Application: Z-16-051
Location: 1114 Mercury Boulevard
Applicant: David Beiter of Goodwill Industries
Zoning: Highway Commercial (CH) District
Requests: 1) A Special Use Permit to allow a Temporary Mobile Recycling Center in
the CH district;
2) An eight (8) foot Variance from Section 31(C)(1) of the Murfreesboro
Zoning Ordinance, which limits the length of Temporary Mobile
Recycling Center receptacles to forty (40) feet; and
3) A 175-foot Variance from Section 31(C)(6) of the Murfreesboro Zoning
Ordinance, which requires a 300-foot minimum distance between
receptacle and residentially-zoned property
1
Request Overview
The applicant, David Beiter of Goodwill Industries, seeks a Special Use Permit and two
Variances from the Board. Chart 1 (Uses Permitted by Zoning District) of the Murfreesboro
Zoning Ordinance identifies Temporary Mobile Recycling Center as a use allowed in the CH
zone by Special Use Permit. Section 31(A) of the Zoning Ordinance places a one-year limitation
on the duration of Special Use Permits granted for this use. Section 31(C)(1) of the Zoning
Ordinance limits the length of Temporary Mobile Recycling Center receptacles to 40 feet.
Section 31(C)(6) requires a minimum distance of 300 feet between a Temporary Mobile
Recycling Center and any residentially-zoned property.
The applicant wishes to continue using a trailer (48 feet in length) for the collection of clothes,
furniture, and miscellaneous household items at the Mercury Plaza shopping center at 1114
Mercury Boulevard, approximately 125 feet from the nearest residentially-zoned property. The
applicant has obtained permission from shopping center management to continue operating the
trailer. In the attached letter of application, the applicant indicates that the trailer at 1114
Mercury Boulevard is visited by an average of 38 donors per day.
Relevant Zoning Ordinance Sections
Section 31(C)(1):
No receptacle shall exceed forty feet in width.
Section 31(C)(6):
No receptacle shall be located closer than three hundred feet from residentially zoned
property.
Staff Comments
With regard to the Special Use Permit, the applicant attests that—with the exception of
receptacle length and distance to residential properties—the requirements listed in Section 9(C)
and Section 31(C) of the Zoning Ordinance have been satisfied. Specifically, the attached letter
of application indicates that the Temporary Mobile Recycling Center: is reasonably compatible
with adjoining properties; has limited signage; is kept in a clean, safe, and sanitary condition;
does not impair traffic flow; has no processing equipment; and upholds minimum required
setbacks. The Board has previously granted a Special Use Permit to this applicant for this use;
the applicant’s current Special Use Permit expires on July 31, 2016.
With regard to the first Variance request, the applicant wishes to continue using a 48-foot trailer,
which exceeds the 40-foot limitation by eight (8) feet. The letter of application indicates that
adhering to the 40-foot trailer limitation when Goodwill Industries employs standard 48-foot
2
trailers would create a hardship and practical difficulty for the applicant. The Board has
previously granted a Variance to the applicant for a trailer 48 feet in length.
With regard to the second Variance request, the applicant wishes to continue using a trailer that
is situated 125 feet from the nearest residentially-zoned property. Section 31(C)(6) of the
Zoning Ordinance requires a minimum separation of 300 feet between a Temporary Mobile
Recycling Center and any residentially-zoned property. Thus, the applicant seeks a 175-foot
variance from this requirement. The western side of Second Avenue is zoned RS-10 and is
currently used for residential purposes. Staff is not aware of any complaints pertaining to the
trailer from neighboring residents. The Board has previously granted a Variance to the applicant
to allow a 125-foot separation between the trailer and the nearest residentially-zoned property.
Each request will require a separate motion.
The applicant will be in attendance at the meeting to discuss the project and answer any
questions the Board may have.
Recommended Conditions
1) The semi-trailer shall not be located within a driveway aisle.
2) All parts of the semi-trailer shall comply with the minimum 42-foot front setback requirement
of the CH zone.
3) The Special Use Permit shall be valid from August 1, 2016, until July 31, 2017.
Attached Exhibits
1. BZA Application
2. Applicant’s Request Letter
3. Site Photographs
4. Applicant’s Supporting Materials
3
102D M 35 CH
CH
4
5
6
7
1114 Mercury Boulevard, aerial showing trailer location
8
1114 Mercury Boulevard, view from west looking eastward (Photo taken by Staff, 7/17/15)
9
10
11
12
13
MURFREESBORO BOARD OF ZONING APPEALS
STAFF REPORT
JULY 27, 2016
Application: Z-16-052
Location: Along the east side of John R. Rice Boulevard
Applicant: Clyde Rountree of Huddleston-Steele Engineering Inc., representing
Mountain Star Properties LLC
Zoning: Highway Commercial (CH) District
Requests: 1) A Special Use Permit to allow a Self-Service Storage Facility in the CH
district; and
2) A Variance from Section 27(K)(3)(a) of the Murfreesboro Zoning
Ordinance, which requires a three (3) foot minimum landscape strip
adjacent to the base of a building along the building’s sides
1
Request Overview
The applicant, Clyde Rountree of Huddleston-Steele Engineering Inc., representing Mountain
Star Properties LLC, wishes to construct an enclosed Self-Service Storage Facility on property
located along the east side of John R. Rice Boulevard. The attached site plan indicates that the
building’s dimensions would be approximately 180 feet by 190 feet. The subject property is a
7.48-acre parcel and is zoned CH. The southern portion of the subject property is being
redeveloped as a Texas Roadhouse restaurant. Chart 1 of the Murfreesboro Zoning Ordinance
indicates that Self-Service Storage Facilities are allowed in the CH district by Special Use
Permit.
In addition to the Special Use Permit request, the applicant also seeks a Variance from Section
27(K)(3)(a) of the Murfreesboro Zoning Ordinance, which requires a three (3) foot minimum
landscape strip adjacent to the base of a building along the building’s sides. As shown on the
site layout exhibit provided by the applicant, the proposed structure would have a landscape strip
only along its John R. Rice Boulevard frontage.
Relevant Zoning Ordinance Section
Section 27(K)(3)(a):
A three (3) foot minimum width landscape strip planted with shrubs, trees, and other
landscape materials in accordance with this Section 27 shall be provided along the front
and sides adjacent to the base of the buildings or separated from buildings by sidewalk.
The landscape area may be used for menu boards to the extent otherwise permitted by this
article and other regulations of the City.
Staff Comments
With regard to the Special Use Permit request, Section 9(D)(2)(uuu) of the Zoning Ordinance
lists five specific standards for Self-Service Storage Facilities. The first standard prohibits
certain activities; the applicant is required to follow these restrictions. The second standard
relates to Self-Service Storage Facilities that share property lines with residential properties. The
proposed facility abuts other CH-zoned properties on all sides. The third standard is a
requirement that a ten-foot landscape strip be planted along the front property line abutting all
public rights-of-way. As shown on the applicant’s site layout exhibit, sufficient space exists
along the front property line to provide a ten-foot landscape strip. In addition to a ten-foot
landscape strip along the right-of-way, the exhibit shows an additional landscape area of
approximately ten feet in width along a portion of the front of the building. The fourth standard
relates to the screening of outdoor storage areas from residential properties. The attached site
plan shows a truck rental area on the north side of the proposed structure; the truck rental area
does not appear to lie adjacent to any residential properties. The fifth standard relates to the
Board’s ability to impose additional screening, lighting, and security measures on the site.
2
Because the proposed structure is completely enclosed, staff does not recommend any additional
measures.
With regard to the Variance request, Section 27(K)(3)(a) of the Zoning Ordinance requires a
three-foot landscape strip along the front and sides of a building. As shown on the site plan, the
applicant intends to install a landscape area across the center portion of the front of the proposed
building. The remaining portions of the building’s base would not have landscape strips. A
review of the building’s elevations indicates that the sides of the structure will include several
garage-type doors; presumably, a landscape strip would prohibit access to these doors. In the
attached request letter, the applicant indicates that additional landscaping along John R. Rice
Boulevard will improve the site’s appearance from the public right-of-way.
The applicant will be in attendance at the meeting to discuss the project and answer any
questions the Board may have.
Attached Exhibits
1. BZA Application
2. Applicant’s Request Letter
3. Site Photographs
4. Applicant’s Supporting Materials
3
4
5
6
John R. Rice Boulevard
Aerial Photographs
Aerial photograph of John R. Rice site. Proposed storage building would be located north of the future
Texas Roadhouse restaurant.
7
Closer view of proposed self-service storage facility site on John R. Rice Boulevard.
8
9
10
Get email alerts for Murfreesboro
A daily email when new agendas and minutes are posted.