Zoning Board of Appeals
Regular MeetingPeachtree Corners, GA · July 17, 2013
Agenda
ZONING BOARD OF APPEALS AGENDA
July 17, 2013
7:00 PM
CITY HALL
A. Roll Call
B. Approval of April 14, 2013 Minutes
C. Old Business: (None)
D. New Business:
1. Request by QuikTrip Corporation for variances associated with the
development of a gas station facility on property located at 3235
Peachtree Corners Circle, Dist. 6, LL 276, Parcel 019, as follows:
a. increase canopy size from 8 sq.ft. to 20 sq.ft.
b. reduce required Tree Density Units from 20 per acre to 13.5 per acre
c. reduce the front landscape strip from 10 ft. to 1 ft.
d. increase the drive isle from 40ft. to 47ft.
e. increase the maximum drive isle from 14 ft. per travel lane to 17’-6”
per travel lane
f. vary from the architectural requirements of the overlay district that
require a minimum of 1ft. deep cornices along the entire front and
extending at least 10ft down the sides of a building
g. vary from the architectural requirements of the overlay district that
require a minimum of a 1ft. high contrasting base along the entire
front and extending at least 10ft down the sides of a building
E. City Business Items: (None)
F. Comments by Board Members.
G. Adjournment.
DRAFT COPY
CITY OF PEACHTREE CORNERS
ZONING BOARD OF APPEALS
APRIL 17, 2013
The City of Peachtree Corners held a meeting on Tuesday, April 17, 2013 at
7:00pm. The meeting was held at City Hall, 147 Technology Parkway, Suite 200,
Peachtree Corners, GA, 30092. The following were in attendance:
Planning Commission: Wayne Knox, Post B
Marcia Brandes, Post A
Amreeta Regmi, Post C
Eric Christ, Post D
James Blum, Post E
Staff: Diana Wheeler, Community Development Director
Kym Chereck, City Clerk
NEW BUSINESS:
1. Request by Chase Bank for variances associated with the
development of a branch bank facility on property located at
4900-5000 block of Peachtree Corners Circle and 5200 block of
Peachtree Parkway as follows:
i. V2013-0001- Increase allowable parking spaces from 18 to 26
spaces.
ii. V2013-0002- Allow more than 20% of parking to be located in the
front and side of the building.
iii. V2013-0003 – Elimination of 4:12 pitched roof (Architectural
Design) requirement in an overlay district.
Diana Wheeler presented the case to the Board. Mrs. Wheeler provided
background information regarding the applicant’s request and informed the
Board that this item would be heard as one item, but would be vote on as three
individual items. The subject property is located at the northeast corner of
Peachtree Parkway and Peachtree Corners Circle on a 1.10 acre tract, zoned C-2
(General Business District). The site is currently undeveloped and densely
wooded with mature evergreens. The applicant proposes to develop the
property with a Chase Bank. The applicant would like to receive some relief
from the Peachtree Corners Overlay requirements. There are three variances
that they are requesting. The first is to increase the allowable parking from the
18 required to the 26 that they are requesting. The second is to be allowed more
than 20% of parking to be located in the front and side of the building. The third
is to eliminate the 4:12 pitched roof requirement in an overlay district. After
review of the application, Staff determined that V2103-001 and V2103-0002 do
have hardships and recommended approval with the following conditions:
Page | 1
DRAFT COPY
1. No more than seventy-seven percent (77%) of the total number of parking
spaces may be located along Peachtree Parkway.
2. The subject property shall be limited to a maximum number of 26
off-street parking spaces.
Furthermore, Staff did not find hardship with V2013-0003, and therefore,
recommended denial of that particular variance.
Mrs. Michelle Rothmeier, Esquire, represented the applicant. The applicant
stated that she was in agreement with Staff’s decision with the exception of the
denial of V2013-0003. Mrs. Rothmeier stated that the applicant is proposing
the elimination of the 4:12 pitched roof in order to accommodate the HVAC units
on the rooftop as opposed to the ground level. Mrs. Rothmeier stated that the
applicant prefers the HVAC unit on the rooftop instead of the ground due to
safety and esthetic reasons.
Chairman Knox asked for public comment concerning this application. There
was no public comment. Chairman Knox closed the public comment portion of
the meeting and asked the Board for a motion. After further discussion, the
Board took the following action:
MOTION ON V2013-0001
BASED ON A THOROUGH REVIEW OF THE ENTIRE RECORD AND THE
HEARING BEFORE THIS BODY, I MOVE THAT THE ZONING BOARD
OF APPEALS MAKE THE FOLLOWING FINDINGS AND CONCLUSIONS
AND APPROVE THE APPLICATION BEFORE IT WITH STAFF’S
RECOMMENDED CONDITIONS; THERE ARE EXTRAORDINARY OR
EXCEPTIONAL CONDITIONS PERTAINING TO THIS PARTICULAR
PROPERTY; THE CONDITIONS OF THE ZONING RESOLUTION
INVOLVING THIS PROPERTY CREATE AN UNNECESSARY HARDSHIP
TO THE OWNER/APPLICANT; THE CONDITIONS OF THE ZONING
RESOLUTION AS APPLIED TO THIS PROPERTY AFFECT ONLY THIS
PROPERTY; THE CONDITIONS OF THE ZONING RESOLUTION AS
APPLIED TO THIS PROPERTY AFFECT ONLY THIS PROPERTY; THE
CONDITIONS OF THE ZONING RESOLUTION AS APPLIED TO THIS
PROPERTY ARE NOT THE RESULT OF ANY ACTIONS OF THE
PROPERTY OWNER; THE CONDITION OF THE PROPERTY ITSELF IS
NOT THE RESULT OF ACTIONS OF THE PROPERTY OWNER; THE
APPLICATION IF GRANTED WOULD NOT CAUSE SUBSTANTIAL
DETRIMENT TO THE PUBLIC GOOD; GRANTING OF THIS
APPLICATION WOULD NOT CAUSE SUBSTANTIAL DETRIMENT TO
THE PUBLIC GOOD; A LITERAL ENFORCEMENT OF THE ZONING
RESOLUTION WILL RESULT IN UNNECESSARY HARDSHIP TO THE
APPLICANT; GRANTING OF THIS APPLICATION WILL NOT RESULT IN
A DETRIMENT TO THE PUBLIC SAFETY OR WELFARE.
By: Eric Christ
Seconded: Marcia Brandes
Vote: (5-0) (Christ, Brandes, Knox, Regmi, Blum)
Page | 2
DRAFT COPY
MOTION ON V2013-0002
BASED ON A THOROUGH REVIEW OF THE ENTIRE RECORD AND THE
HEARING BEFORE THIS BODY, I MOVE THAT THE ZONING BOARD
OF APPEALS MAKE THE FOLLOWING FINDINGS AND CONCLUSIONS
AND APPROVE THE APPLICATION BEFORE IT WITH STAFF’S
RECOMMENDED CONDITIONS, AS THERE ARE EXTRAORDINARY OR
EXCEPTIONAL CONDITIONS PERTAINING TO THIS PARTICULAR
PROPERTY.
By: Marcia Brandes
Seconded: Eric Christ
Vote: (5-0) (Brandes, Christ, Knox, Regmi, Blum)
MOTION ON V2013-0003
BASED ON A THOROUGH REVIEW OF THE ENTIRE RECORD AND THE
HEARING BEFORE THIS BODY, I MOVE THAT THE ZONING BOARD
OF APPEALS MAKE THE FOLLOWING FINDINGS AND CONCLUSIONS
AND DENY THE APPLICATION BEFORE IT, THE CONDITIONS OF THE
ZONING RESOLUTION INVOLVING THIS PROPERTY DO NOT CREATE
AN UNNECESSARY HARDSHIP TO THE APPLICANT; AND THE
CONDITION OF THE PROPOSED PROPERTY IS THE RESULT OF THE
ACTIONS OF THE PROPERTY OWNER AS RELATED TO THE DESIGN
AESTHETIC THAT THEY ARE SEEKING; AND A LITERAL
ENFORCEMENT OF THE ZONING RESOLUTION WILL NOT RESULT IN
UNNECESSARY HARDSHIP TO THE APPLICATION.
By: Jim Blum
Seconded: Amreeta Regmi
Vote: (5-0) (Blum, Regmi, Knox, Brandes, Christ)
CITY BUSINESS:
Elections of Chairman and Vice Chairman.
NOMINATION OF WAYNE KNOX AS CHAIRMAN.
By: Eric Christ
Accepted by: Wayne Knox
Seconded: Amreeta Regmi
Vote: (5-0) (Christ, Regmi, Knox, Brandes, Blum)
NOMINATION OF ERIC CHRIST AS VICE CHAIRMAN.
By: Jams Blum
Accepted by: Eric Christ
Seconded: Amreeta Regmi
Vote: (Blum, Regmi, Knox, Brandes, Christ)
The Zoning Board of Appeals meeting concluded at 8:15 PM.
Page | 3
DRAFT COPY
Approved, Attest:
_________________________ _______________________________
Wayne Knox, Chairman Kym Chereck, City Clerk
Page | 4
CITY OF PEACHTREE CORNERS
COMMUNITY DEVELOPMENT DEPARTMENT
VARIANCE ANALYSIS
ZBA HEARING DATE: July 17, 2013
CASE NUMBER(S) : V2013-004
ZONING : C-2 (GENERAL BUSINESS DISTRICT)
LOCATION : 3200 BLOCK OF PEACHTREE CORNERS CIRCLE
MAP NUMBER : R6276 019 & R6276 073
PROPOSED DEVELOPMENT : CONVENIENCE STORE WITH FUEL PUMPS
VARIANCE(S) REQUESTED : a) INCREASE CANOPY SIGN SIZE
FROM 8 SQUARE FEET TO 20 SQUARE FEET
b) TO REDUCE THE REQUIRED
TREE DENSITY UNITS FROM 20 UNITS PER
ACRE TO 13.5 UNITS PER ACRE
c) TO REDUCE THE 10-FOOT LANDSCAPE
STRIP TO 1-FOOT
d) INCREASE INTERIOR DRIVEWAY
SURROUNDING GASOLINE PUMP CANOPY
FROM 40 FEET TO 47 FEET
e) INCREASE INTERIOR DRIVEWAYS
PROVIDING PRIMARY ACCESS TO
LOADING/UNLOADING ZONES OR
LOADING DOCKS FOR TRUCK TRAFFIC
FROM 14 FEET TO 17.5 FEET IN WIDTH PER
TRAVEL LANE
f) ELIMINATION OF 1-FOOT DEEP
CORNICES ALONG THE ENTIRE FRONT
AND SIDES OF BUILDINGS
g) ELIMINATION OF 1-FOOT HIGH
CONTRASTING BASE ALONG THE ENTIRE
FRONT AND SIDES OF BUILDINGS
APPLICANT: QUIKTRIP CORPORATION
952 OLD PEACHTREE ROAD NW
LAWRENCEVILLE, GA 30043
CONTACT: PATRICK CONNER
EMAIL: PCONNER@QUIKTRIP.COM
PHONE: 770.325.6721
OWNER: QUIKTRIP CORPORATION
952 OLD PEACHTREE ROAD NW
LAWRENCEVILLE, GA 30043
I. BACKGROUND
The subject property consists of two parcels that will be combined to total 1.463 acres and is
located on the eastern side of Peachtree Corners Circle, northeast of its intersection with
Peachtree Industrial Boulevard. Both parcels are zoned C-2 (General Business District). The site
is currently developed with a coin laundry (converted from a former Waffle House) and a
QuikTrip gas station. The applicant intends to initiate demolition of the existing QuikTrip and
coin laundry buildings and construct in its place a new “Generation III” QuikTrip design concept
that features an updated building and canopy design. The proposed rebuilding would result in a
5,858 square-foot convenience store with 16 fuel pumps and 39 parking spaces.
Directly adjacent to the north of the property is an office building occupied by an embroidery
business and general contractor, zoned M-1 (Light Industry District). Further north and northeast
are existing multi-family developments, zoned RM, RM-10, and RM-13(Multi-Family Residence
District). Adjacent to the east is a small industrial office park incorporating five separate parcels,
zoned M-1. To the south is a Burger King restaurant, office building, and J.R.’s Log House
Restaurant, all zoned C-2. Across Peachtree Corners Circle, to the west, are existing office-
warehouse developments consisting of Bay Colony I Gwinnett Commercial Center and Corners
West Business Center, zoned M-1, and Peachtree Corporate Center, zoned C-2.
II. ANALYSIS
The applicant has requested seven variances for development of a 5,858 square-foot QuikTrip
convenience store with fuel pumps on the eastern side of Peachtree Corners Circle. The applicant
seeks variances to increase the size of the canopy sign from 8 square feet to 20 square feet; to
reduce the Activity Center/Corridor Overlay District required landscaping requirements of 20
Tree Density Units per acre to 13.5 units per acre; to reduce the landscape strip from 10 feet to 1
foot; to increase the interior driveway surrounding gasoline pump canopy to 47 feet from 40 feet;
to increase the width of interior driveways providing access to loading/unloading zones for truck
traffic from 14 feet to 17.5 feet; and eliminate the architectural design requirements of the
Activity Center/Corridor Overlay District requiring 1-foot deep cornices and 1-foot high
contrasting base along the entire width of the front and the sides of the building for at least ten
feet.
The applicant seeks to install a 20 square-foot sign on the north and south ends of the canopy.
The City of Peachtree Corners Sign Ordinance allows convenience stores with fuel pumps to
have two signs per canopy face with each sign limited to 8 square feet in size. Under the existing
Sign Ordinance, a four-sided canopy is permitted a total of 8 canopy signs with an aggregate
total of 64 square feet of signage. Although the applicant’s request would allow for individually
larger signs, the request would limit the site to only two canopy signs and an aggregate square
footage of 40 square feet. The overall reduction in the number and aggregate square footage of
canopy signage would contribute to the applicant’s intent of providing an aesthetically pleasing
and streamlined design. Therefore, if this variance is granted, individual signs would be larger,
however, the number of signs and overall square footage of signs would be reduced.
The subject property lies within the Activity Center/Corridor Overlay District and is required to
provide 20 Tree Density Units per acre; however, the applicant seeks to reduce the tree density to
13.5.units per acre. Staff has compared the as-built survey to the proposed site plan and has
determined that a significant portion of existing vegetation of evergreens/pines located along the
rear property line of both parcels, which could have be counted towards compliance with the tree
density requirement, would be removed and replaced by a minimal landscape plan. The proposed
landscape plan would incorporate a single row of trees along the sides and southeast corner of
the property and within the landscape island located in the right-of-way of Peachtree Corners
Circle. Although the purchase of the adjacent coin laundry site would expand the Quiktrip
property by slightly more than a third of an acre and the proposed redesign of the canopy area
from a double row of fuel pumps to a single row would provide additional space to orient the
larger convenience store footprint closer to the road, the applicant has elected to locate the
building towards the rear property line and to provide circular vehicle access by constructing a
driveway behind the convenience store, further reducing vegetated areas and increasing
impervious surface. By redesigning the layout of the property and eliminating extra parking
spaces (a minimum of 12 spaces are required and 39 are provided), the proposed convenience
store could be relocated towards the northern property line and closer to the road to preserve
existing vegetation and to comply with the landscaping requirements of the overlay district.
Alternatively, the 60 ft. distance from the building to the gas pumps could be reduced to
accommodate the additional landscaping along the front.
QuikTrip seeks to reduce the 10-foot landscape strip along Peachtree Corners Circle as required
by the Activity Center/Corridor Overlay District to 1-foot. The proposed site plan shows that the
distance from the right-of-way to the central point of the gas pump base is 40 feet. With a 10
foot landscape strip incorporated along the road frontage there would be approximately 20 feet of
clearance from the landscape strip to the nearest canopy support column. Per the City’s Zoning
Ordinance interior driveways providing a width of 20 to 22 feet could provide safe travel for
two-way traffic. Providing a full 10-foot landscape strip could also provide additional greenspace
for the site to comply with the tree density requirement of the overlay district. Furthermore,
addition of a 10-foot landscape strip could contribute to the safe ingress/egress of vehicles for the
site by providing additional length for stacking of vehicles exiting the property and could assist
in influencing vehicles entering the site to utilize interior driveways to access fuel pumps and
limit the possibility of vehicles accessing the fueling area by entering diagonally from Peachtree
Corners Circle. While the tree density and landscape strip variances would allow for design
convenience, adjustments could be made to the site plan to accommodate the required trees and
green space.
The underlying justification to seek variances to increase the interior driveway surrounding
gasoline pump canopy from 40 feet to 47 feet and to increase the width of interior driveways
providing access to loading/unloading zones for truck traffic from 14 feet to 17.5 feet, as
expressed by the applicant in their letter of intent, is related to providing patrons the ability to
safely navigate the site. Providing wider interior driveways as requested could help to mitigate
traffic hazards that are typically associated with businesses that generate high traffic volume and
that require sharing of driveways by delivery trucks and passenger vehicles. While the extra
lane widths augment safety, they also reduce green space; therefore, a balance is needed to
preserve both objectives.
QuikTrip also seeks to eliminate the overlay district requirement for incorporation of 1-foot deep
cornices and 1-foot height contrasting base along the entire front façade and the sides of the
building for at least 10 feet. The Burger King restaurant located directly south of the subject
property and within the Peachtree Corners Overlay District, was constructed with cornices
around the entirety of the parapet roof and also a contrasting stone base. The elevations
submitted by the applicant shows that the front of the proposed convenience store building
partially complies with the requirements of the overlay district, as cornices are provided on top
of the flat roof and a base line of bricks is provided underneath the glass windows along the front
façade. Not fully complying with the architectural requirements of the overlay district could
establish a negative precedent; however, the proposed building elevations appear to meet the
intent of the regulations and, in this case, a strict adherence to the standards may result in a
building that looks ‘overly busy’ and, therefore, less attractive.
III. CONCLUSION
In conclusion, several of the requested variances can be justified due to hardship or because they
create an improved condition for the property over the strict application of the code. The
variance to increase the size of canopy signs is justified because the overall number and
aggregate square footage of canopy signage would be reduced. The applicant’s intent to
minimize traffic hazards and to provide for safe flow of traffic internally to the site by increasing
interior driveway widths can also be justified. The architectural style of the building, while not
strictly compliant with the overlay standards, is generally in keeping with the intent of the
regulations. The building design incorporates elements from the overlay standards while
attempting to convey a contemporary style. However, a hardship to support the reduction of tree
density units from 20 units per acre to 13.5 units per acre and the reduction in the landscape strip
from 10 feet to 1-foot has not be demonstrated by the applicant. With the acquisition of the
adjacent coin laundry parcel, the subject property increased its overall size and developable area.
Through some site modifications, the applicant might be able to construct a larger convenience
store as desired while preserving existing vegetation and providing a full landscape strip on the
property.
Therefore, after review of the application, it is recommended V2013-004 (a) and (d) through
(g) be approved with the conditions noted below. It is also recommended that variances (b) and
(c) be denied.
1. The subject property shall be limited to two canopy signs with each sign not to
exceed 20 square feet.
2. Interior driveways immediately surrounding the fuel pump canopy shall be no greater
than 47 feet in width.
3. Interior driveways providing primary access to loading or unloading zones shall be no
greater than 17.5 feet in width per travel lane.
4. Building elevations shall be substantially similar to QuikTrip elevations drawings
dated 5/29/13.
5. Lighting shall be contained in cut-off type luminaries and shall be directed in toward
the property so as not to reflect into adjacent properties. Provide photometric plan at
time of submittal of land disturbance permit to show compliance with this condition.
6. A site plan showing truck turning template to demonstrate the need for additional
pavement shall be submitted at time of submittal of land disturbance permit.
7. Plans shall comply with the Buffer, Landscape and Tree Ordinance requirement of 16
units/ acre and Overlay requirement of 1 tree/ 50 feet of frontage.
8. Shrubs and ornamental ground covers shall be provided along front and side
landscape strips (3’ island minimum) and in landscape islands (instead of grass). The
side shrub planting should extend 80’ minimum from frontage.
9. Except for propane tanks and dispenser machines, there shall be no outdoor storage of
retail products.
APPLICABLE CODE REQUIREMENTS:
City of Peachtree Corners Sign Ordinance; Section 18: Convenience Stores and Service Stations
with Pump Islands.
(a) Convenience stores and service stations with pump islands may have additional
signage subject to the following limitations:
(1) Two signs per canopy face with a maximum of 8 square feet per sign
City of Peachtree Corners Zoning Resolution; Article XIII: Use Provisions; Section 1315:
Activity Center/Corridor Overlay District Requirements; Section 1315.2: Design Requirements;
Subsection 2: Landscaping Requirements.
2.A. Provide, at a minimum, 20 Tree Density Units per acre for all non-residential
development. Type and size of plantings shall be in compliance with City of
Peachtree Corners Buffer, Landscape and Tree Ordinance. At least 50% of
plantings shall consist of trees 3-inches in caliper (dbh) or greater.
2.C. Provide a minimum ten-foot wide landscaped strip between all road rights-of-way
and the back-of-curb of abutting off-street paved parking lots. Landscaped strips
between road rights-of-way and the edge of abutting off-street grassed parking
areas shall be five-feet in width. At a minimum, landscaped strips shall be planted
in accordance with the City of Peachtree Corners Buffer, Landscape and Tree
Ordinance.
City of Peachtree Corners Zoning Resolution; Article X: Off-Street Automobile Parking and
Loading and Unloading Spaces; Section 1001: Plan and Design Standards for Off-Street Parking;
Section 2: Interior Driveways.
d. Interior driveways providing primary access to loading/unloading zones or
loading docks for truck traffic may be increased to 14 feet in width per travel lane.
Adjustments to geometry may be granted, if it can be shown with turn-radius
templates that modifications to the standards are required.
e. Interior driveways surrounding gasoline pump canopies may be increased to 40
feet in total width (as measured from the base of the gasoline pump islands).
City of Peachtree Corners Zoning Resolution; Article XIII: Use Provisions; Section 1315:
Activity Center/Corridor Overlay District Requirements; Section 1315.2: Design Requirements;
Subsection 5: Architectural Design.
5.B.(5) Building design shall include minimum one (1) foot deep cornices,
extending along the entire front of buildings and the sides of buildings at
least (10) ten feet.
5.B.(6) Building design shall include a minimum one (1) foot high contrasting
base, extending along the entire front of buildings and the sides of
buildings at least ten (10) feet.
VARIANCE REQUIREMENTS:
In an effort to assist the Zoning Board of Appeals in considering the application and its merits,
staff has included specific conditions that must be considered for a variance to be granted, as
provided in Section 1605 of the City of Peachtree Corners Zoning Resolution. Those
considerations include:
A. There are extraordinary and exceptional conditions pertaining to the particular property in
question because of its size, shape or topography, and
B. The application of the Resolution to this particular piece of property would create an
unnecessary hardship, and
C. Such conditions are peculiar to the particular piece of property involved, and
D. Such conditions are not the result of any actions of the property owner, and
E. Relief, if granted, would not cause substantial detriment to the public good nor impair the
purposes or intent of this Resolution.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Q SITE LEGEND Q
P P
T
DAP
PROJECT NO.:
A
SITE
N N
M M
0735
L L
PEACHTREE CORNERS CIRCLE
K K
J
ATLANTA, GA. J
H H
G G
ANY UNAUTHORIZED USE, REPRODUCTION,
PUBLICATION, DISTRIBUTION, OR SALE IN
WHOLE OR IN PART, IS STRICTLY FORBIDDEN.
PROTOTYPE: P-70 (02/01/12)
F DIVISION: F
VERSION: 001
DESIGNED BY:
DRAWN BY: KSR
REVIEWED BY:
E E
ORIGINAL ISSUE DATE:
D D
DESCRIPTION
DATE
C C
REV
PEACHTREE CORNERS CIRCLE SHEET TITLE:
B N PRELIMINARY SITE PLAN B
SHEET NUMBER:
A 20 10 0 20 40 A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
2'-8" 104'-8" 2'-8" 8'-4" 50'-8"
2'-8" 104'-8" 2'-8" 50'-8" 8'-4"
13'-1" 25'-8" 25'-8" 25'-8" 25'-8" 25'-8" 25'-8" 25'-8" 13'-1"
West Elevation
205'-10"
18'-6" Min. / 22'-6" Max.
AFF Top of Canopy
15'-0" Min. / 19'-0" Max.
AFF Bottom of Canopy
Trash Enclosure
7'-10"
Finish Floor
9'-6" 13'-0" 9'-6" 9'-6" 13'-0" 9'-6"
North Elevation 14'-0" 12'-8" South Elevation
32'-0" 32'-0"
Front Elevation Side Elevation
1 2 3 4 5 6
N
4705 S. 129th E. Ave - Tulsa, OK 74134-7008
P.O. Box 3475 - Tulsa, OK 74101-3475
p:918.615.7700
M
L
K
MH10-4PGQ REDUCED BASE
Custom Horizontal
J
H
G
Monument Sign
F
CDC 05/22/13
C:\vault_qt\07 Atlanta\07-0735\05 Presentation\07-0735-MH10-4PGQ.dwg - I_#00 May 29, 2013 - 1:09pm - bpettus
E
NOTES DRAWN BY ISSUE DATE
SQUARE FOOTAGE
D 40 90 100
TYPEFACE INSIDE CAN ENTIRE SIGN
C
SCALE:
SPECIFICATIONS:
LOGO 1/4" = 1'-0"
Flat Solar grade, Clear Cyro Face, .177 thickness, painted on 2nd surface to match 3M Cardinal Red Translucent #3632-53, Akzo Nobel, no SERIAL NUMBER:
B embossment.
Pricer MH10-4PGQ
Flat Solar grade, Clear Cyro Face, .177 thickness, painted on 2nd surface, Akzo Noble Black, manual Font Numerals, Clear Helvetica Condensed
font. Product Panels, Cyro, Clear text area, painted 2nd surface Akzo Nobel Opaque Black, Diesel Product Panel painted 2nd surface to match
STORE NUMBER:
PMS 7481C Translucent Green, Akzo Noble.
LOGO Cabinet/Pricer Cabinet/Base
Aluminum Construction, Internally illuminated with GE Tetra PowerStrip DS65/GE PS24 Power Supplies. LOGO Cabinet painted Akzo Noble, QT
A
Red SIGN9141 Low Gloss. Pricer Cabinet and Base painted Akzo Noble Black Low Gloss. Accent Trim section painted 1st surface Akzo Noble
Silver-Low Gloss.
0735
1 2 3 4 5 6
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Landscape Schedule
Q Q
P P
PROJECT NO.:
N N
M M
Applicable Landscape Requirements
0735
L L
PEACHTREE CORNERS CIRCLE
LANDSCAPE REQUIREMENTS - TREE DENSITY CALCULATIONS 1.463 ACRE X 15 TDU/ACRE 4" TREES = 0.6 TDU's
= 29.26 TDU 33 X 0.6 =19.8 TDU's
20 TDU PER ACRE PROVIDED
K LANDSCAPE REQUIREMENTS - LANDSCAPE ISLANDS K
AS SHOWN AS SHOWN
ATLANTA, GA.
STREET TREE CALCULATIONS-PEACHTREE CORNERS OVERLAY
1 NON-ORAMENTAL SHADE TREE SPACED 50 FEET-ON-CENTER PEACHTREE CORNERS CIRCLE 5 TREES PROVIDED
J ALONG THE RIGHT OF WAY 325.5 - 70/50 = 5.10 TREES J
ARCHITECTURAL DESIGN
AS SHOWN AS SHOWN
H H
G G
ANY UNAUTHORIZED USE, REPRODUCTION,
PUBLICATION, DISTRIBUTION, OR SALE IN
WHOLE OR IN PART, IS STRICTLY FORBIDDEN.
PROTOTYPE: P-70 (02/01/12)
F DIVISION: F
VERSION: 001
DESIGNED BY:
DRAWN BY: KSR
REVIEWED BY:
E E
ORIGINAL ISSUE DATE:
D D
DESCRIPTION
DATE
C C
REV
PEACHTREE CORNERS CIRCLE SHEET TITLE:
B N LANDSCAPE PLAN B
SHEET NUMBER:
A 20 10 0 20 40 A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
CITY OF PEACHTREE CORNERS
COMMUNITY DEVELOPMENT
147 Technology Parkway, Suite 200, Peachtree Corners, GA 30092
Tel: 678.691.1200 | www.cityofpeachtreecornersga.com
ZONING BOARD OF APPEALS
QUIKTRIP
CASE NUMBER: V 2013-0004
HEARING DATE: JULY 17 , 2013
147 Technology Pkwy., Suite 200, 7:00PM
PROPERTY ADDRESS: 3225 & 3235 Peachtree Corners Circle
Get email alerts for Peachtree Corners
A daily email when new agendas and minutes are posted.