Muyni
← Back to Vienna

Board of Architectural Review Work Session

Regular Meeting

Vienna, VA · January 9, 2024

AgendaMinutes

Minutes

Town of Vienna 127 Center Street South Vienna, VA. 22180 p: 703-255-6300 TTY 7111 Meeting Minutes Board of Architectural Review Work Session Tuesday, January 9, 2024 8:00 AM Charles Robinson Jr. Town Hall, 127 Center St. South Work Session Town of Vienna Page 1 Printed on 1/22/2024 Board of Architectural Review Work Meeting Minutes January 9, 2024 Session BARWS24-07 400 Courthouse Road SW - Meadow Lane Park - Exterior Modifications - Work 8 Session The Board of Architectural Review met for a work session in Town Hall, 127 Center St S. Vienna, Virginia, on Tuesday, January 9, 2024. The following members were present: Ms. Hanley, Ms. van Doorn, Mr. Layer, and Mr. Cheselka. Absent members: Mr. Baldwin. Staff present: Planner Sharmaine Abaied and Clerk to the Board Yaska Camacho Castillo. Applicants present: Director of Parks and Recreation Leslie Herman, Deputy Director of Parks and Recreation Nicole Falceto, Landscape Architect Jeffrey Holzer, and Roberto Gonzalez from Smith-Midland Sales. At the Board of Architectural Review meeting on November 16, 2023, Ms. Herman presented the Meadow Lane bathroom exterior modifications. The exterior modifications consisted of demolishing and replacing the existing bathroom with a prefab building built by Smith-Midland. During the meeting, the board voiced their concerns regarding the roof, lights, overhangs, gutters, ventilation, drainage, and colors. The board recommended a work session to allow the applicants to incorporate the board's thoughts and recommendations and present a new proposal during the work session. In the work session, Ms. Herman stated that she, along with Paul Layer and Patty Hanley, visited a few sites with installations similar to what is proposed for the Meadow Lane Park bathroom. The board was presented with the following possible changes: 1. Embossed concrete roof with cedar shake pattern to remain. 2. Section of embossed concrete walls with lap siding patterns to remain as is. 3. Section of embossed concrete walls with stone pattern to include a four-inch band board pattern at the top of the stone. The height of the base stone pattern, including the band board, is 32 inches above the concrete apron. 4. Add natural light panels to the side walls. 5. Add louver grille protection similar to the Lovettsville facility. Add flat louver grille protection on the interior and exterior of the lower louvers. The color will match the doors. The louvers will be stainless steel or anodized aluminum. 6. Reduce the width of the privacy panel between the sink and urinal to 1’- 6”. Install an aluminum channel at the back wall and the outside of the panel from floor to ceiling. Use only stainless or non-corroding fasteners and receivers. 7. Revise the wall height to 8 feet, increasing the roof overhang front and back to 1 foot and 8 inches on the side, and increase the roof slope to a 5-inch rise and 12-inch run. 8. Provide and install cap flashing over the ridge joint of the roof and the sealant at the joint – color to match the roof color. 9. Delete gutter and downspouts if the embossed concrete roof is selected. Provide conventional roof overlay if gutter and downspout are chosen. If the gutter and downspouts are selected in conjunction with the embossed concrete roof, providing connection detail for connecting the gutter to the concrete edge. 10. Slope and concrete apron surrounding the building to drain water away from the building on all sides a minimum of quarter inch rise to 12-inch run and add the landscape swales to keep the water further away. 11. Presented two options for colors: o Option # 1: Embossed concrete roof – Silver Grey (HC124); concrete embossed lap Town of Vienna Page 2 Printed on 1/22/2024 Board of Architectural Review Work Meeting Minutes January 9, 2024 Session siding – Galvano (SW 4027); embossed band board and stone embossed base – Slate Gray (SW 4026); metal doors, frames, and protection grilles – Tower Grey (SW 4018); interior surfaces: floors – Structural Grey (SW 4031); walls – Cirrus White (SW 4012); Ceiling - Pillar White (SW 4029). Note: all pertinent concrete surfaces will receive concrete stain as submitted, and all pertinent metals will receive Protective & Marine Coatings as submitted – unless noted otherwise. Colors are interchangeable. o Option # 2: Embossed concrete roof – Charred Walnut (HC109); concrete embossed lap siding – Tannery (SW 4004); embossed band board and stone embossed base – Corrugate Brown (SW 4016); metal doors, frames, and protection grilles – Bolt Brown (SW – 4001); interior surfaces: floors - Structural Grey (SW 4031), walls – Cirrus White (SW 4012); Ceiling - Pillar White (SW 4029). Note: all pertinent concrete surfaces will receive concrete stain as submitted, and all pertinent metals will receive Protective & Marine Coatings as submitted – unless noted otherwise. Colors are interchangeable – The board supported most of the changes and made the following recommendations: • The embossed concrete roof with a cedar shake pattern will be replaced with a standing seam roof. • The embossed concrete wall with lap siding pattern remain as is. • The section of embossed concrete wall with stone pattern to include a 4” band with the height of the pattern and band board be 32” above the concrete apron. • Add natural light panels to the side walls. • Add the louvered grill protection on the facility for the interior and exterior. • Verify that the louvers are anodized aluminum or stainless steel. If so, they can stay as is. If not, they must be finished in the same colors as the door. No louvers on the door. • Revise the wall height to 8’, increasing the overhang front and back to 1’ with 8” on the side • Increase the roof slope 5” rise and 12” run. • Slope of the concrete apron on all sides for drainage be a minimum ¼” rise to 12” run. • Add landscape swales (for drainage) discussed at meeting. • Delete- number 8 and 9 on the list since the concrete roof will be replaced with a standing seam roof. • Please submit the color and specification for the standing seam roof. • The board recommended option 1 for the colors, excluding the color option for the roof. • Lighting- LED fixtures, 3000 kelvins, lockable dimmer switch, the light lumens should be equivalent to 100 watts incandescent lamp, or the light lumens should be equivalent to 75 watts incandescent lamp if there are no dimmers. • Location for lights: two on the front side adjacent to the doors, no higher than the door height, and centered above the plaque that says, " Men and Women. " Similar placement for the backlight. • Provide the details on the warranty of the water fountain. • Eliminate the gutter. It was noted that the Board of Architectural Review only reviews exterior modifications, not interior modifications. Interior recommendations: • Interior integrity of the privacy wall Yaska Camacho Castillo Board Clerk Meeting Adjournment Town of Vienna Page 3 Printed on 1/22/2024 Board of Architectural Review Work Meeting Minutes January 9, 2024 Session THE TOWN OF VIENNA IS COMMITTED TO FULL COMPLIANCE WITH THE AMERICANS WITH DISABILITIES ACT STANDARDS. TRANSLATION SERVICES, ASSISTANCE OR ACCOMMODATION REQUESTS FROM PERSONS WITH DISABILITIES ARE TO BE REQUESTED NOT LESS THAN 3 WORKING DAYS BEFORE THE DAY OF THE EVENT. PLEASE CALL (703) 255-6304, OR 711 VIRGINIA RELAY SERVICE FOR THE HEARING IMPAIRED. Town of Vienna Page 4 Printed on 1/22/2024

Agenda

Town of Vienna 127 Center Street South Vienna, VA. 22180 p: 703-255-6300 TTY 7111 Meeting Agenda Board of Architectural Review Work Session Tuesday, January 9, 2024 8:00 AM Charles Robinson Jr. Town Hall, 127 Center St. South Work Session BARWS24-078 400 Courthouse Road SW - Meadow Lane Park - Exterior Modifications - Work Session Attachments: 01 - Staff Memo -400 Courthouse Rd SW - Meadow Lane Park - Exterior Modifications 02 - 400 Courthouse Rd SW - Parks & Rec - Narrative 03 - 400 Courthouse Rd SW - Meadow Lane Park - Application & Authorization 04 - 400 Courthouse Rd SW - Meadow Lane Park - Bathroom Rendering 05 - 400 Courthouse Road - 1222 Custom Restroom - Budgetary Proposal 06 - 400 Courthouse Road - Meadow Lane Park - Topo Survey 07 - 400 Courthouse Road - Meadow Lane Park - Vienna Building Layout 08 - 400 Courthouse Road - Meadow Lane Park - Vienna Building Materials 09 - 400 Courthouse Road - Meadow Lane Park - Concrete Stain chart 10 - 400 Courthouse Road - Meadow Lane Park - Shiplap SW Color System 11 - 400 Courthouse Road - Meadow Lane Park - Exterior Light Specifications 12 - 400 Courthouse Road - Meadow Lane Park - Site Plan 13 - 400 Courthouse Road - Meadow Lane Park Bathroom -Existing Condi Meeting Adjournment THE TOWN OF VIENNA IS COMMITTED TO FULL COMPLIANCE WITH THE AMERICANS WITH DISABILITIES ACT STANDARDS. TRANSLATION SERVICES, ASSISTANCE OR ACCOMMODATION REQUESTS FROM PERSONS WITH DISABILITIES ARE TO BE REQUESTED NOT LESS THAN 3 WORKING DAYS BEFORE THE DAY OF THE EVENT. PLEASE CALL (703) 255-6304, OR 711 VIRGINIA RELAY SERVICE FOR THE HEARING IMPAIRED. Page 1 Printed on 1/4/2024

Get email alerts for Vienna

A daily email when new agendas and minutes are posted.

Report an issue with this meeting