Hendersonville Planning Commission
Regular MeetingHendersonville, TN · July 2, 2024
Minutes
HPC Minutes
07/02/2024
HENDERSONVILLE PLANNING COMMISSION
MINUTES
Main Meeting Room
Tuesday, July 2, 2024
6:30 PM
Chairman Jeff Coker called the meeting to order at 6:30 PM in the City Hall Main Meeting
Room, 101 Maple Drive North, Hendersonville, TN.
1. OPENING PRAYER (Youtube Link)
Commissioner Hardwick led the opening prayer.
2. ROLL CALL (Youtube Link)
Present: Jeff Coker, John Evans, Barry Hardwick, Charles Hasty, Beth Longmire, Vanessa
Silkwood, and Wendy Slatery.
Absent: Michael Martin
Also Present: Keith Free, Planning Director; Timothy Whitten, Assistant Planning Director; Trey
Lavender, Assistant City Engineer; Chris Willyard, Deputy Fire Marshall; J. Ritterbeck, Economic
Development Coordinator & Community Planner; and Caitlin Shinn, Assistant Planner.
BRIEF ACTION SUMMARY
A. Acceptance of Agenda (Youtube Link)
MOTION by Hasty, seconded by Longmire, to accept the Hendersonville Planning
Commission Meeting Agenda of Tuesday, July 2, 2024.
1
HPC Minutes
07/02/2024
Altizer, Coker, Evans, Hardwick, Hasty, Longmire, Silkwood, and Slatery voted aye.
Nay: None. Absent: Martin.
MOTION PASSED. (8-0-0)
B. Minutes (Youtube Link)
MOTION by Hasty, seconded by Altizer, to accept the Hendersonville Planning Commission
Meeting Minutes of Tuesday, June 4, 2024 with minor errors to be corrected.
Altizer, Evans, Hardwick, Hasty, Longmire, and Slatery voted aye.
Coker and Silkwood abstained. Nay: None. Absent: Martin.
MOTION PASSED. (6-0-2)
C. Consent Agenda (Youtube Link)
MOTION by Longmire, seconded by Altizer, to approve the consent agenda with the following
project with all staff comments:
(1) Molly Walton Industrial – Site Plan
Altizer, Coker, Evans, Hardwick, Hasty, Longmire, Silkwood, and Slatery voted aye.
Nay: None. None abstained. Absent: Martin.
MOTION PASSED. (8-0-0)
D. 24-055-001: Music City Studios – Molly Walton Industrial – CDP Add Use (Light
Manufacturing) (Youtube Link)
MOTION by Coker, seconded by Silkwood, to approve the Music City Studios – Molly Walton
Industrial – CDP Add Use (Light Manufacturing), with all staff comments.
Altizer, Coker, Evans, Hardwick, Hasty, Longmire, Silkwood, and Slatery voted aye.
Nay: None. None abstained. Absent: Martin.
MOTION PASSED. (8-0-0)
E. Adjournment (Youtube Link)
MOTION by Altizer, seconded by Slatery, to adjourn the Hendersonville Planning Commission
Meeting at 7:10 PM.
2
HPC Minutes
07/02/2024
Altizer, Coker, Evans, Hardwick, Hasty, Longmire, Silkwood, and Slatery voted aye.
None voted nay. None abstained. Absent: Martin.
MOTION PASSED. (8-0-0)
3. PUBLIC HEARING (Youtube Link)
Request by Lincoln Property Company, to amend Music City Studios Comprehensive
Development Plan to add Light Manufacturing to the List of Permitted Uses. The property is
located at 157 Molly Walton Drive, on the south side of Molly Walton Drive, and on the north
side of Forest Retreat Road, as identified by Sumner County Tax Map 160 043.01 and 160
043.02.
Public Hearing opened at 6:32 PM.
Richard Markum and Jerry Gray spoke during the Public Hearing.
Public Hearing was closed at 6:36 PM.
4. PUBLIC COMMENT (AGENDA ITEMS ONLY) (Youtube Link)
No one spoke during the public comments.
5. ACCEPTANCE OF AGENDA (Youtube Link)
MOTION by Hasty, seconded by Longmire, to accept the Hendersonville Planning Commission
Meeting Agenda of Tuesday, July 2, 2024.
Altizer, Coker, Evans, Hardwick, Hasty, Longmire, Silkwood, and Slatery voted aye.
Nay: None. Absent: Martin.
MOTION PASSED. (8-0-0)
3
HPC Minutes
07/02/2024
6. MINUTES: (Youtube Link)
MOTION by Hasty, seconded by Altizer, to accept the Hendersonville Planning Commission
Meeting Minutes of Tuesday, June 4, 2024 with minor errors to be corrected.
Altizer, Evans, Hardwick, Hasty, Longmire, and Slatery voted aye.
Coker and Silkwood abstained. Nay: None. Absent: Martin.
MOTION PASSED. (6-0-2)
7. CONSENT AGENDA (Youtube Link)
24-052-001: Molly Walton Industrial – Site Plan
Owner: Lincoln Property Company
Location: 157 Molly Walton Dr, Parcel 160 043.01, 160 043.02
Lead Planning Staff: Timothy Whitten
MOTION by Longmire, seconded by Altizer, to approve the consent agenda with the following
project with all staff comments:
(1) Molly Walton Industrial – Site Plan
Altizer, Coker, Evans, Hardwick, Hasty, Longmire, Silkwood, and Slatery voted aye.
Nay: None. None abstained. Absent: Martin.
MOTION PASSED. (8-0-0)
4
HPC Minutes
07/02/2024
STAFF REPORT
This is the site of the Music City Studio (Stonecutter Capital Management, LLC) media production
facility proposed a couple of years ago on Molly Walton Drive. The site is zoned Industrial – Planned
Development (I-PD). Stonecutter no longer has plans to build at this location. In its place, Lincoln
Property Company (LPC) is proposing to build a facility that will accommodate mainly warehousing
and light manufacturing businesses. Five buildings are proposed, totaling 496,080 square feet. In
comparison, Music City Studios had 4 buildings totaling 678,620 square feet, including a 90-foot-tall
building on the north side of Molly Walton. LCP is proposing a tractor-trailer parking lot on the north
side of Molly Walton instead of a building. The proposed maximum height of the buildings is about 45
feet.
A total of 4 curb cuts are proposed on Molly Walton, vs 5 that were proposed with the Music City
Studios plan. The emergency-only access on Forest Retreat will be retained.
The landscape buffer along the east side of the development will be retained.
5
HPC Minutes
07/02/2024
Old Music City Studios layout Proposed Molly Walton Industrial layout
6
HPC Minutes
07/02/2024
7
HPC Minutes
07/02/2024
STAFF COMMENTS – PLANNING DEPARTMENT:
1. Stamp all plans.
2. Provide a site survey stamped by a registered surveyor.
3. Dumpster facilities do not appear to be adequate for this size development – please address.
4. Provide sample of retaining wall block for review and approval. The retaining wall along Molly
Walton especially will require a decorative type block.
5. Provide a detail of the pedestrian safety fence. Specify finish/color.
6. Provide a detail of the guardrail. Specify finish/color.
7. Revise grading plan along east property line to show no grading or land disturbance within
the required 30ft. buffer.
8. Sheet C4-11 – north arrow shown incorrectly.
9. Sheet C4-12 – slope along Molly Walton shall not exceed 3:1.
10. Provide NES-approved electric service plan.
11. On tree plan, show all trees >10dbh to be removed and saved. Provide calculations showing
required replacement. Provide plan for replacement and/or payment into tree bank. Show
replacement trees in a separate plant schedule from the main schedule, and designate with
8
HPC Minutes
07/02/2024
“R” on planting plan. Required parking lot trees and street trees to not count towards tree
replacement.
12. Provide irrigation plan.
13. Height-to-caliper ratio must meet Am. Standard for Nursery Stock, latest edition.
14. Provide some taller columnar shrubs/trees within building foundation planting beds to help
break up wall expanses.
15. Plants intended to screen the trailer parking area must be of sufficient quantity and height to
substantially screen the parking lot at planting.
16. Detention pond screening should take into account the road elevation about the pond; adjust
heights and locations to provide more effective screening from road. Also, it is not required to
provide screening between the pond and the stream buffer.
17. Indicate proposed light pole heights.
18. Lights closest to residence on Forest Retreat may need glare shields.
19. Show outlines of RTUs on each elevation. Building parapet walls must be at least as tall as
tallest units, or provide sight-line study showing proposed parapet height is sufficient to
screen units from street.
20. Please correct the scale on the building elevations.
Submitted by Timothy Whitten, RLA, AICP, Assistant Planning Director (June 27, 2024)
STAFF COMMENTS –PUBLIC WORKS:
1. See Markups.
2. Site Plan
- Label all easements as indicated on the plat.
- Provide a smooth horizontal alignment at the tie in for the extension of Molly Walton Drive.
Ensure that the horizontal and vertical alignment are designed in accordance with the AASHTO
Policy on Geometric Design of Highways and Street.
- There are several unresolved comments on each ESPC sheet which the engineer has stated will
be addressed in future revisions.
- There are several instances where the invert elevations for proposed headwalls does not tie into
the adjacent proposed grading in the EPSC Plans and in the Grading and Drainage plans. Please
revise.
- Flood Zone AE on the northwest corner of the site currently has no regulatory floodway
designated. Because the stream is upstream and discharges directly into the flood zone, it is
considered an unmapped stream and potentially the floodway for the flood zone in the
northwest corner. In accordance with Municipal Code 18-420.D and 18-425.I, please ensure
that there is no fill or structures placed within twice the width of the stream from either bank,
and verify with hydrologic and hydraulic analyses that there is no more than 1' of rise at any
point along the stream within the property boundary or in the adjacent Flood Zone AE.
9
HPC Minutes
07/02/2024
- Please provide a culvert analysis to verify that the existing culvert encapsulating the stream
onsite and the culvert downstream of the site outfall under Molly Walton Blvd. have capacity to
convey the 25-year storm.
- There are several instances where the slopes of accessible facilities exceed what is allowed per
ADA design standards. Please revise accordingly.
3. Drainage Report
- This project will involve alterations to potential Waters of the United States, therefore
coordination with USACE is needed and a concurrence letter from them is required.
- Please provide an explanation on what design parameters were considered to ensure that the
overall pond design achieves 80% TSS removal, with supporting references to literature.
4. SWPPP
- The EPSC plans included in this document are not consistent with those provided in the Site
Plan. Please revise.
- It appears that the sediment basins were designed based on the post-development conditions.
The sediment basins should be designed based on the worst-case scenario which is likely EPSC
Stage 1 with bare soil within the limits of disturbance.
5. TIS
- Staff has no comments on the TIS. Based on the analysis provided, there will be a negligible
impact to the delays experienced at the intersections of Free Hill Road and Molly Walton Drive,
and Free Hill Road and W Main St. such that the level of service will remain the same.
Submitted by Stephen Winzenread, PE, Assistant Public Works Director/City Engineer (June 27,
2024)
STAFF COMMENTS – FIRE DEPARTMENT:
1. Hendersonville Subdivision Regulations 3.7.2.1 – For commercial districts or commercial
subdivisions, there shall be one (1) or more hydrants at each street intersection depending on the
required fire flow, with intermediate hydrants so that they are not over three hundred (300) feet
apart. ACTION: For commercial districts or commercial subdivisions, one (1) or more hydrants at
each street intersection depending on the required fire flow, with intermediate hydrants so that they
are not over three hundred (300) feet apart per Hendersonville Subdivision Regulations 3.7.2.1
2. Hendersonville Subdivision Regulations 3.7.2.2– The type and location of each fire hydrant shall be
designated by the Hendersonville Fire Department and approved by the governing utility district.
Hydrant specifications in 3.7.2. ACTION: The type and location of each fire hydrant shall be
designated by the Hendersonville Fire Department and approved by the governing utility district.
Hydrant specifications in 3.7.2
10
HPC Minutes
07/02/2024
3. NFPA 2016 6.4.5.4* Fire department connections shall be located not more than 100 ft (30.5 m)
from the nearest Fire hydrant connected to an approved water supply. ACTION: Fire department
connections shall be located not more than 100 ft (30.5 m) from the nearest Fire hydrant connected
to an approved water supply per code NFPA 2016 6.4.5.4*
4. Area of building 1 should be used for this measurement. ACTION: IFC 2018 D104.3 Where two fire
apparatus access roads are required, they shall be placed a distance apart equal to not less than
one half of the length of the maximum overall diagonal dimension of the lot or area to be served,
measured in a straight line between accesses.
5. IFC 2018 503.2.4 -Turning Radius: Provide a truck turning template using the Hendersonville Fire
Department template. ACTION: Provide a truck turning template using the Hendersonville Fire
Department template
6. IFC 2018 912.2.1 - Provide Sprinkler system FDC on street (address) side of building. ACTION:
Provide Sprinkler system FDC on street (address) side of building per code IFC 2018 912.2.1
7. IFC 2018 D105.2 – Aerial fire apparatus access roads shall have a minimum unobstructed width of
26’, exclusive of shoulders, in the immediate vicinity of the building or portion thereof. ACTION:
Aerial fire apparatus access roads have a minimum unobstructed width of 26’, exclusive of
shoulders, in the immediate vicinity of the building or portion thereof per code IFC 2018 D105.2
8. Hendersonville Subdivision Regulations 3.7.2.1 – Provide a hydrant layout that meets the fire flow
requirements and identify each source and the calculated flow rate. ACTION: Provide a hydrant
layout that meets the fire flow requirements and identify each source and the calculated flow rate
per Hendersonville Subdivision Regulations 3.7.2.1–
Submitted by Chris Willyard, Deputy Fire Marshal (June 27, 2024)
STAFF COMMENTS – UTILITY DISTRICT:
1. Water contact will be the same as sewer on sheet 1. Show water connections at Forest Retreat
emergency entrance.
Submitted by David Brigance, HUD Construction Supervisor (June 27, 2024)
8. DEVELOPMENT PLANS: (Youtube Link)
24-055-001: Music City Studios – Molly Walton Industrial – CDP Add-Use (Light Manufacturing)
Owner: Lincoln Property Company
Location: 157 Molly Walton Drive, Parcel 160 043.01, 160 043.02
Lead Planning Staff: Timothy Whitten
11
HPC Minutes
07/02/2024
MOTION by Coker, seconded by Silkwood, to approve the Music City Studios – Molly Walton
Industrial – CDP Add Use (Light Manufacturing), with all staff comments.
Altizer, Coker, Evans, Hardwick, Hasty, Longmire, Silkwood, and Slatery voted aye.
Nay: None. None abstained. Absent: Martin.
MOTION PASSED. (8-0-0)
STAFF REPORT
This is the site of the Music City Studio media production facility proposed a couple of years ago on
Molly Walton Drive. The site is zoned Industrial – Planned Development (I-PD). Music City Studio is
no longer has plans to build at this location.
Lincoln Property Company (LPC) is now proposing to construct five buildings that would
accommodate warehousing and light manufacturing uses. Light manufacturing is not currently
listed among the allowed uses on the Music City Studios master plan, so LPC is requesting that it be
added as an allowed use. Light Manufacturing is a permitted use in the Industrial base zoning, and
12
HPC Minutes
07/02/2024
so is a by-right use for all the other existing Industrial-zoned properties on Molly Walton Dr. and
Freehill Rd.. Other uses shown as allowed on the master plan are: Warehouse Distribution, Data
Center, Medical/Dental Laboratory, Printing Shop, Research & Development Facility, Public Safety
Facility, and Major Media Production Facility.
In their application, LCP states:
Existing Zoning
13
HPC Minutes
07/02/2024
Old Music City Studios layout Proposed Molly Walton Industrial layout
14
HPC Minutes
07/02/2024
STAFF COMMENTS – PLANNING DEPARTMENT:
1. No comments.
Submitted by Timothy Whitten, RLA, AICP, Assistant Planning Director (June 27, 2024)
STAFF COMMENTS –PUBLIC WORKS:
1. No comments.
Submitted by Stephen Winzenread, PE, Assistant Public Works Director/City Engineer (June 27, 2024)
15
HPC Minutes
07/02/2024
STAFF COMMENTS – FIRE DEPARTMENT:
1. 1. No comments.
Submitted by Chris Willyard, Deputy Fire Marshal (June 27,, 2024)
STAFF COMMENTS – UTILITY DISTRICT:
1. No comments.
Submitted by David Brigance, HUD Construction Supervisor (June 27, 2024)
9. STAFF-LEVEL PROJECTS, APPROVED: (Youtube Link)
The Hendersonville Planning Commission acknowledged staff’s approval of the following projects.
No action was taken.
24-027-001: Alfieri 1009 West Main St (1009 West Main St) – Site Plan
24-043-001: Birdie Bros Outdoor Patio (300 Indian Lake Blvd Ste E160) – Site Plan
24-009-001: BP Pulse EV Charging Stations (768 East Main St) – Site Plan
24-057-001: Edmonton State Bank Exterior Color Change (255 Indian Lake Blvd) – Site Plan
24-056-001: Millstone Phase 2 Lot 68 Parking Lot (471 Carriage House Ln) – Site Plan
24-037-001: Premier Park Phase 1 (98 Volunteer Dr) – FDP Amendment
24-051-001: Retreat at Indian Lake Parking Lot Expansion (908 Cardinal Ln) – Site Plan
16
HPC Minutes
07/02/2024
24-033-001: Verizon Small Cell (1101 Forest Retreat Rd) – Site Plan
10. STAFF-LEVEL PROJECTS, PENDING: (Youtube Link)
24-049-001: 1041 Avondale Parking Lot (1041 Avondale Rd) – Site Plan / A 6/28
24-054-001: Alexander Commercial (281 East Main St) – Site Plan / A 6/28
23-103-001: Broken Paddle Outfitters Outbuilding (167 E Main St) – Site Plan / A 4/12
24-045-001: Hendersonville High School Dugout Improvements (131 Conway Twitty –
Field 3) – Site Plan / A 6/28
24-053-001: Music City Studios Molly Walton (157 Molly Walton Dr) – CDP Amendment
/ S 6/21
24-046-001: Saundersville Industrial Park Lot 41 Resub (104 Jessica Lauren Ct) – Final
Plat / S 6/27
24-034-001: Verizon Small Cell (203B N. Anderson Ln) – Site Plan / A 5/2
24-035-001: Verizon Small Cell (215A Indian Lake Blvd) – Site Plan / A 5/2
13. PLANNING DIRECTOR COMMENTS: (Youtube Link)
Director Free discussed there have been an increase in pre-application meetings and expecting
to see more over the next few months. Director Free advised Jim’N Nick’s Restaurant had
submitted for the August meeting agenda. Falcon Ridge also submitted to be on the August
agenda to decrease the lot sizes and increase the open space.
17
HPC Minutes
07/02/2024
14. ADJOURNMENT (Youtube Link)
MOTION by Altizer, seconded by Slatery, to adjourn the Hendersonville Planning Commission
Meeting at 7:10 PM.
Altizer, Coker, Evans, Hardwick, Hasty, Longmire, Silkwood, and Slatery voted aye.
None voted nay. None abstained. Absent: Martin.
MOTION PASSED. (8-0-0)
VANESSA SILKWOOD, Secretary JEFF COKER, Chairman
KEITH L. FREE, MPA, AICP, Planning Director
18
Agenda
HPC Agenda
07/02/2024
HENDERSONVILLE PLANNING COMMISSION
AGENDA
Main Meeting Room
Tuesday, July 2, 2024
6:30 PM
1. OPENING PRAYER
2. ROLL CALL
3. PUBLIC HEARING
Request by Lincoln Property Company to amend the Music City Studios Comprehensive
Development Plan to add Light Manufacturing to the List of Permitted Uses. The property is
located at 157 Molly Walton Drive, on the south side of Molly Walton Drive, and on the north
side of Forest Retreat Road, as identified by Sumner County Tax Map 160 043.01 and 160
043.02.
4. PUBLIC COMMENT (AGENDA ITEMS ONLY)
5. ACCEPTANCE OF AGENDA
6. MINUTES:
Minutes of June 4, 2024
7. CONSENT AGENDA
1
HPC Agenda
07/02/2024
8. DEVELOPMENT PLANS:
24-055-001: Music City Studios – Molly Walton Industrial – CDP Add-Use (Light
Manufacturing)
Owner: Lincoln Property Company
Location: 157 Molly Walton Drive, Parcel 160 043.01, 160 043.02
Lead Planning Staff: Timothy Whitten
9. SITE PLANS:
24-052-001: Molly Walton Industrial – Site Plan
Owner: Lincoln Property Company
Location: 157 Molly Walton Drive, Parcel 160 043.01, 160 043.02
Lead Planning Staff: Timothy Whitten
10. STAFF-LEVEL PROJECTS, APPROVED:
24-027-001: Alfieri 1009 West Main St (1009 West Main St) – Site Plan
24-043-001: Birdie Bros Outdoor Patio (300 Indian Lake Blvd Ste E160) – Site Plan
24-009-001: BP Pulse EV Charging Stations (768 East Main St) – Site Plan
24-057-001: Edmonton State Bank Exterior Color Change (255 Indian Lake Blvd) – Site Plan
24-056-001: Millstone Phase 2 Lot 68 Parking Lot (471 Carriage House Lane) – Site Plan
24-037-001: Premier Park Lot 1 (98 Volunteer Dr) – FDP Amendment
24-051-001: Retreat at Indian Lake Parking Lot Expansion (908 Cardinal Ln) – Site Plan
24-033-001: Verizon Small Cell (1101 Forest Retreat Rd) – Site Plan
2
HPC Agenda
07/02/2024
11. STAFF-LEVEL PROJECTS, PENDING:
24-049-001: 1041 Avondale Parking Lot (1041 Avondale Rd)
Site Plan / A 06/28/24
24-054-001: Alexander Commercial (281 East Main St)
Final Plat / A 06/28/24
23-103-001: Broken Paddle Outfitters Outbuilding (167 East Main St)
Site Plan / A 04/12/24
24-045-001: Hendersonville High School Dugout Improvements (131 Conway Twitty –
Field 3) Site Plan / S 06/21/24
24-050-001: Indian Lake Peninsula Church Donation Building (235 Indian Lake Rd)
Site Plan / A 06/13/24
24-053-001: Music City Studios Molly Walton (157 Molly Walton)
CDP Amendment / S 06/21/24
24-046-001: Saundersville Industrial Park Lot 41 Resub (104 Jessica Lauren Ct)
Final Plat / S 06/27/24
24-048-001: State Farm 361 West Main Exterior Color Change (361 W Main St)
Site Plan / S 06/21/24
24-034-001: Verizon Small Cell (203B N Anderson Lane)
Site Plan / A 05/02/24
24-035-001: Verizon Small Cell (215A Indian Lake Blvd)
Site Plan / A 05/02/24
3
HPC Agenda
07/02/2024
10. PLANNING DIRECTOR COMMENTS:
11. ADJOURNMENT
4
AGENDA DATE: July 2, 2024
RESOLUTION/ORDINANCE # Not Applicable
HPC PROJECT #: 24-055-001
FINAL STAFF
PROJECT NAME: Music City Studios – Molly Walton Industrial
REPORT &
PROJECT TYPE: CDP Add Use (Light Manufacturing)
PROJECT LOCATION: 157 Molly Walton Dr, Parcel 160 043.01, 043.02 COMMENTS
WARD: Ward 3
STAFF REPORT: 1
This is the site of the Music City Studio media production facility proposed a couple of years ago on Molly
Walton Drive. The site is zoned Industrial – Planned Development (I-PD). Music City Studio is no longer has
plans to build at this location.
Lincoln Property Company (LPC) is now proposing to construct five buildings that would accommodate
warehousing and light manufacturing uses. Light manufacturing is not currently listed among the allowed
uses on the Music City Studios master plan, so LPC is requesting that it be added as an allowed use. Light
Manufacturing is a permitted use in the Industrial base zoning, and so is a by-right use for all the other
2
existing Industrial-zoned properties on Molly Walton Dr. and Freehill Rd.. Other uses shown as allowed on
the master plan are: Warehouse Distribution, Data Center, Medical/Dental Laboratory, Printing Shop,
Research & Development Facility, Public Safety Facility, and Major Media Production Facility.
In their application, LCP states:
Existing Zoning
3
Old Music City Studios layout Proposed Molly Walton Industrial layout
4
STAFF COMMENTS – PLANNING DEPARTMENT: 2
1. No comments.
Submitted by Timothy Whitten, RLA, AICP, Assistant Planning Director (June 27, 2024)
STAFF COMMENTS – PUBLIC WORKS: 3
1. No comments.
Submitted by Stephen Winzenread, PE, Assistant Public Works Director/City Engineer (June 27,
2024)
5
STAFF COMMENTS – FIRE DEPARTMENT: 4
1. No comments.
Submitted by Chris Willyard, Deputy Fire Marshal (June 27, 2024)
STAFF COMMENTS – UTILITY DISTRICT: 5
1. No comments.
Submitted by David Brigance, HUD Construction Supervisor (June 27, 2024)
AGENDA DATE: July 2, 2024
RESOLUTION/ORDINANCE # Not Applicable
HPC PROJECT #: 24-052-001
FINAL STAFF
PROJECT NAME: Molly Walton Industrial
REPORT &
PROJECT TYPE: Site Plan
PROJECT LOCATION: 157 Molly Walton Drive, Parcel 160 043.01, 043.02 COMMENTS
WARD: Ward 3
STAFF REPORT: 1
This is the site of the Music City Studio (Stonecutter Capital Management, LLC) media production facility
proposed a couple of years ago on Molly Walton Drive. The site is zoned Industrial – Planned Development
(I-PD). Stonecutter no longer has plans to build at this location. In its place, Lincoln Property Company
(LPC) is proposing to build a facility that will accommodate mainly warehousing and light manufacturing
2
businesses. Five buildings are proposed, totaling 496,080 square feet. In comparison, Music City Studios
had 4 buildings totaling 678,620 square feet, including a 90-foot-tall building on the north side of Molly
Walton. LCP is proposing a tractor-trailer parking lot on the north side of Molly Walton instead of a
building. The proposed maximum height of the buildings is about 45 feet.
A total of 4 curb cuts are proposed on Molly Walton, vs 5 that were proposed with the Music City Studios
plan. The emergency-only access on Forest Retreat will be retained.
The landscape buffer along the east side of the development will be retained.
Old Music City Studios layout Proposed Molly Walton Industrial layout
3
4
STAFF COMMENTS – PLANNING DEPARTMENT: 2
1. Stamp all plans.
2. Provide a site survey stamped by a registered surveyor.
3. Dumpster facilities do not appear to be adequate for this size development – please address.
4. Provide sample of retaining wall block for review and approval. The retaining wall along Molly
Walton especially will require a decorative type block.
5. Provide a detail of the pedestrian safety fence. Specify finish/color.
6. Provide a detail of the guardrail. Specify finish/color.
7. Revise grading plan along east property line to show no grading or land disturbance within the
required 30ft. buffer.
8. Sheet C4-11 – north arrow shown incorrectly.
9. Sheet C4-12 – slope along Molly Walton shall not exceed 3:1.
10. Provide NES-approved electric service plan.
11. On tree plan, show all trees >10dbh to be removed and saved. Provide calculations showing
required replacement. Provide plan for replacement and/or payment into tree bank. Show
replacement trees in a separate plant schedule from the main schedule, and designate with “R”
on planting plan. Required parking lot trees and street trees to not count towards tree
replacement.
12. Provide irrigation plan.
13. Height-to-caliper ratio must meet Am. Standard for Nursery Stock, latest edition.
14. Provide some taller columnar shrubs/trees within building foundation planting beds to help break
up wall expanses.
15. Plants intended to screen the trailer parking area must be of sufficient quantity and height to
substantially screen the parking lot at planting.
16. Detention pond screening should take into account the road elevation about the pond; adjust
heights and locations to provide more effective screening from road. Also, it is not required to
provide screening between the pond and the stream buffer.
17. Indicate proposed light pole heights.
18. Lights closest to residence on Forest Retreat may need glare shields.
19. Show outlines of RTUs on each elevation. Building parapet walls must be at least as tall as tallest
units, or provide sight-line study showing proposed parapet height is sufficient to screen units from
street.
20. Please correct the scale on the building elevations.
Submitted by Timothy Whitten, RLA, AICP, Assistant Planning Director (June 27, 2024)
STAFF COMMENTS – PUBLIC WORKS: 3
1. See Markups.
2. Site Plan
- Label all easements as indicated on the plat.
5
- Provide a smooth horizontal alignment at the tie in for the extension of Molly Walton Drive.
Ensure that the horizontal and vertical alignment are designed in accordance with the
AASHTO Policy on Geometric Design of Highways and Street.
- There are several unresolved comments on each ESPC sheet which the engineer has stated
will be addressed in future revisions.
- There are several instances where the invert elevations for proposed headwalls does not tie
into the adjacent proposed grading in the EPSC Plans and in the Grading and Drainage plans.
Please revise.
- Flood Zone AE on the northwest corner of the site currently has no regulatory floodway
designated. Because the stream is upstream and discharges directly into the flood zone, it is
considered an unmapped stream and potentially the floodway for the flood zone in the
northwest corner. In accordance with Municipal Code 18-420.D and 18-425.I, please ensure
that there is no fill or structures placed within twice the width of the stream from either bank,
and verify with hydrologic and hydraulic analyses that there is no more than 1' of rise at any
point along the stream within the property boundary or in the adjacent Flood Zone AE.
- Please provide a culvert analysis to verify that the existing culvert encapsulating the stream
onsite and the culvert downstream of the site outfall under Molly Walton Blvd. have capacity
to convey the 25-year storm.
- There are several instances where the slopes of accessible facilities exceed what is allowed
per ADA design standards. Please revise accordingly.
3. Drainage Report
- This project will involve alterations to potential Waters of the United States, therefore
coordination with USACE is needed and a concurrence letter from them is required.
- Please provide an explanation on what design parameters were considered to ensure that the
overall pond design achieves 80% TSS removal, with supporting references to literature.
4. SWPPP
- The EPSC plans included in this document are not consistent with those provided in the Site
Plan. Please revise.
- It appears that the sediment basins were designed based on the post-development
conditions. The sediment basins should be designed based on the worst-case scenario which
is likely EPSC Stage 1 with bare soil within the limits of disturbance.
5. TIS
- Staff has no comments on the TIS. Based on the analysis provided, there will be a negligible
impact to the delays experienced at the intersections of Free Hill Road and Molly Walton
Drive, and Free Hill Road and W Main St. such that the level of service will remain the same.
Submitted by Stephen Winzenread, PE, Assistant Public Works Director/City Engineer (June 27,
2024)
6
STAFF COMMENTS – FIRE DEPARTMENT: 4
1. Hendersonville Subdivision Regulations 3.7.2.1 – For commercial districts or commercial
subdivisions, there shall be one (1) or more hydrants at each street intersection depending on
the required fire flow, with intermediate hydrants so that they are not over three hundred (300)
feet apart. ACTION: For commercial districts or commercial subdivisions, one (1) or more
hydrants at each street intersection depending on the required fire flow, with intermediate
hydrants so that they are not over three hundred (300) feet apart per Hendersonville Subdivision
Regulations 3.7.2.1
2. Hendersonville Subdivision Regulations 3.7.2.2– The type and location of each fire hydrant shall
be designated by the Hendersonville Fire Department and approved by the governing utility
district. Hydrant specifications in 3.7.2. ACTION: The type and location of each fire hydrant shall
be designated by the Hendersonville Fire Department and approved by the governing utility
district. Hydrant specifications in 3.7.2
3. NFPA 2016 6.4.5.4* Fire department connections shall be located not more than 100 ft (30.5 m)
from the nearest Fire hydrant connected to an approved water supply. ACTION: Fire department
connections shall be located not more than 100 ft (30.5 m) from the nearest Fire hydrant
connected to an approved water supply per code NFPA 2016 6.4.5.4*
4. Area of building 1 should be used for this measurement. ACTION: IFC 2018 D104.3 Where two
fire apparatus access roads are required, they shall be placed a distance apart equal to not less
than one half of the length of the maximum overall diagonal dimension of the lot or area to be
served, measured in a straight line between accesses.
5. IFC 2018 503.2.4 -Turning Radius: Provide a truck turning template using the Hendersonville Fire
Department template. ACTION: Provide a truck turning template using the Hendersonville Fire
Department template
6. IFC 2018 912.2.1 - Provide Sprinkler system FDC on street (address) side of building. ACTION:
Provide Sprinkler system FDC on street (address) side of building per code IFC 2018 912.2.1
7. IFC 2018 D105.2 – Aerial fire apparatus access roads shall have a minimum unobstructed width
of 26’, exclusive of shoulders, in the immediate vicinity of the building or portion thereof. ACTION:
Aerial fire apparatus access roads have a minimum unobstructed width of 26’, exclusive of
shoulders, in the immediate vicinity of the building or portion thereof per code IFC 2018 D105.2
8. Hendersonville Subdivision Regulations 3.7.2.1 – Provide a hydrant layout that meets the fire
flow requirements and identify each source and the calculated flow rate. ACTION: Provide a
hydrant layout that meets the fire flow requirements and identify each source and the calculated
flow rate per Hendersonville Subdivision Regulations 3.7.2.1–
Submitted by Chris Willyard, Deputy Fire Marshal (June 27, 2024)
7
STAFF COMMENTS – UTILITY DISTRICT: 5
1. Water contact will be the same as sewer on sheet 1. Show water connections at Forest Retreat
emergency entrance.
Submitted by David Brigance, HUD Construction Supervisor (June 27, 2024)
Get email alerts for Hendersonville
A daily email when new agendas and minutes are posted.